JHJoe Heffron

Joe Heffron

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joe Heffron has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Association of runoff risk with private well contamination in a fractured dolostone aquifer

    by Joe Heffron, Joel P. Stokdyk, Tucker R. Burch, Rachel M. Cook, Aaron D. Firnstahl, Eric O. Young, Jessica F. Sherman, Dustin Goering, Burney A. Kieke, Mark A. Borchardt

    In the United States, private well owners are responsible for monitoring and maintaining their drinking water but have little control over neighboring contamination sources and limited information about daily water quality. Potential for rapid contamination in karst settings exacerbates the challenge. The Runoff Risk Advisory Forecast (RRAF) is a real‐time online tool available in five US states that helps nutrient applicators avoid times and locations of high runoff risk. We wanted to determine if RRAF could be repurposed in areas susceptible to groundwater contamination to inform well owners of conditions when contamination is likely. Private wells were repeatedly sampled on seven dates (32–36 wells per date) and analyzed for nitrate‐nitrogen, total coliforms, and bovine manure markers. Three‐day windows of RRAF risk prior to sampling were selected post hoc, ranging from 1 to 3 days prior for manure markers to 10–12 days prior for nitrate. Contaminants were associated with RRAF values of ≥75% within these windows based on observed weather. A hydrologic association between RRAF risk and groundwater depth was also apparent. Overall, results suggest the RRAF model anticipates conditions of elevated contamination risk for susceptible wells. For nitrate, between‐well variation and delayed peak concentration suggested that well location and construction factors may be more informative than runoff events. Microbial contamination was rapid and distributed among wells, with one or more detections of coliforms in 31% of wells and bovine markers in 61% of wells. Thus, a warning system based on the RRAF model could help identify conditions of acute pathogen exposure.

  • Open Access

    Detection of Viral, Bacterial, and Protozoan Pathogens and Microbial Source Tracking Markers in Paired Large- and Small-Volume Water Samples

    by Joe Heffron, Joel P. Stokdyk, Aaron D. Firnstahl, Rachel M. Cook, Claire Hruby, Mark A. Borchardt


  • Open Access

    Mitigation of viruses of concern and bacteriophage surrogates via common unit processes for water reuse: A meta-analysis

    by Joe Heffron, Maryam Samsami, Samantha Juedemann, Jennifer Lavin, Shadi Tavakoli Nick, Burney A. Kieke, Brooke K. Mayer


  • Open Access

    A Comparison of Porphyrin Photosensitizers in Photodynamic Inactivation of RNA and DNA Bacteriophages

    by Joe Heffron, Matthew Bork, Brooke K. Mayer, Troy Skwor

    Effective broad-spectrum antiviral treatments are in dire need as disinfectants and therapeutic alternatives. One such method of disinfection is photodynamic inactivation, which involves the production of reactive oxygen species from dissolved oxygen in response to light-stimulated photosensitizers. This study evaluated the efficacy of functionalized porphyrin compounds for photodynamic inactivation of bacteriophages as human virus surrogates. A blue-light light emitting diode (LED) lamp was used to activate porphyrin compounds in aqueous solution (phosphate buffer). The DNA bacteriophages ΦX174 and P22 were more resistant to porphyrin TMPyP photodynamic inactivation than RNA bacteriophage fr, with increasing rates of inactivation in the order: ΦX174 << P22 << fr. Bacteriophage ΦX174 was therefore considered a resistant virus suitable for the evaluation of three additional porphyrins. These porphyrins were synthesized from TMPyP by inclusion of a central palladium ion (PdT4) and/or the addition of a hydrophobic C14 chain (PdC14 or C14). While the inactivation rate of bacteriophage ΦX174 via TMPyP was similar to previous reports of resistant viruses, ΦX174 inactivation increased by a factor of approximately 2.5 using the metalloporphyrins PdT4 and PdC14. The order of porphyrin effectiveness was TMPyP < C14 < PdT4 < PdC14, indicating that both Pd2+ ligation and C14 functionalization aided virus inactivation.


  • Virus Isoelectric Point Estimation: Theories and Methods

    by Joe Heffron, Brooke K. Mayer

    Much of virus fate, both in the environment and in physical/chemical treatment, is dependent on electrostatic interactions. Developing an accurate means of predicting virion isoelectric point (pI) would help to understand and anticipate virus fate and transport, especially for viruses that are not readily propagated in the lab.


  • Improved Virus Isoelectric Point Estimation by Exclusion of Known and Predicted Genome-Binding Regions

    by Joe Heffron, Brooke K. Mayer

    This model fits predicted pIs to empirical values for a diverse set of viruses. The results suggest that many previously reported discrepancies between theoretical and empirical virus pIs can be explained by coulombic neutralization of PBRs of the inner capsid. Given the diversity of virus capsid structures, this nonarbitrary, heuristic approach to predicting virus pI offers an effective alternative to a simplistic, one-size-fits-all charge model of the virion. The accurate, structure-based prediction of PBRs of the virus capsid employed here may also be of general interest to structural virologists.


  • Open Access

    Improved virus isoelectric point estimation by exclusion of known and predicted genome-binding regions

    by Joe Heffron, Brooke K. Mayer

    Accurate prediction of the isoelectric point (pI) of viruses is beneficial for modeling virus behavior in environmental transport and physical/chemical treatment applications. However, the empirically measured pIs of many viruses have thus far defied simple explanation, let alone prediction, based on the ionizable amino acid composition of the virus capsid. Here, we suggest an approach for predicting virus pI by excluding capsid regions that stabilize the virus polynucleotide via electrostatic interactions. This method was applied first to viruses with known polynucleotide-binding regions (PBRs) and/or 3D structures. Then, PBRs were predicted in a group of 32 unique viral capsid proteome sequences via conserved structures and sequence motifs. Removing predicted PBRs resulted in a significantly better fit to empirical pI values. After modification, mean differences between theoretical and empirical pI values were reduced from 2.1 ± 2.4 to 0.1 ± 1.7 pH units. Importance This model is the first to fit predicted pIs to empirical values for a diverse set of viruses. The results suggest that many previously-reported discrepancies between theoretical and empirical virus pIs can be explained by coulombic neutralization of PBRs of the inner capsid. Given the diversity of virus capsid structures, this nonarbitrary, heuristic approach to predicting virus pI offers an effective alternative to a simplistic, one-size-fits-all charge model of the virion. The accurate, structure-based prediction of PBRs of the virus capsid employed here may also be of general interest to structural virologists.

  • Open Access

    Electrocoagulation as a Pretreatment for Electroxidation of E. coli

    by William Lynn, Joe Heffron, Brooke K. Mayer

    Insufficient funding and operator training, logistics of chemical transport, and variable source water quality can pose challenges for small drinking water treatment systems. Portable, robust electrochemical processes may offer a strategy to address these challenges. In this study, electrocoagulation (EC) and electrooxidation (EO) were investigated using two model surface waters and two model groundwaters to determine the efficacy of sequential EC-EO for mitigating Escherichia coli. EO alone (1.67 mA/cm2, 1 min) provided 0.03 to 3.9 logs mitigation in the four model waters. EC alone (10 mA/cm2, 5 min) achieved ≥1 log E. coli mitigation in all model waters. Sequential EC-EO did not achieve greater mitigation than EC alone. To enhance removal of natural organic matter, the initial pH was decreased. Lower initial pH (pH 5–6) improved E. coli mitigation during both stages of EC-EO. EC-EO also had slightly greater E. coli mitigation than EC alone at lower pH. However, EO alone provided more energy efficient E. coli mitigation than either EC or EC-EO.