Shingo Kunioka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shingo Kunioka has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
- Hiroyuki Kamiya
Department of Cardiac Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
25 shared publications Hiroyuki Kamiya
22 shared publications- Ryohei Ushioda
Department of Cardiac Surgery, Asahikawa Medical University, Asahikawa, Japan
16 shared publications - Masahiro Tsutsui
Department of Cardiac Surgery, Asahikawa Medical University, Asahikawa, Japan
13 shared publications - Ryo Okubo
Department of Cardiac Surgery, Asahikawa Medical University , Midorigaoka Higashi 2-1-1-1, Asahikawa 078-8510
12 shared publications - Aina Hirofuji
Department of Cardiac Surgery, Asahikawa Medical University, 2-1-1-1 Midorigaoka, Higashi, Asahikawa, Hokkaido, Japan
9 shared publications
Latest Publications
- Open Access
- 6 November 2026
- Published by Springer Nature in JA Clinical Reports
Management-changing diagnosis of presumed clamp-related brachiocephalic artery injury by transesophageal echocardiography during total aortic arch replacement: a case report
Background: Aortic arch branch malperfusion during total aortic arch replacement requires prompt diagnosis. We report a case in which transesophageal echocardiography (TEE) clarified discordant intraoperative monitoring findings and directly guided surgical revision. Case presentation: A 77-year-old woman underwent total aortic arch replacement. After separation from cardiopulmonary bypass, right radial arterial pressure and right regional cerebral oxygen saturation markedly decreased, whereas direct brachiocephalic arterial pressure remained preserved. Targeted TEE demonstrated brachiocephalic artery dissection extending into the right common carotid artery with true-lumen compression, loss of antegrade flow into the right subclavian artery, and retrograde vertebral collateral flow. These findings prompted immediate surgical revision. After reconstruction, arterial pressure and cerebral oxygen saturation recovered, and TEE confirmed restoration of antegrade flow. Conclusions: Targeted TEE can clarify discordant monitoring findings in aortic arch branch malperfusion and provide critical information for intraoperative surgical decision-making.
- 6 November 2026
- Published by Springer Nature in JA Clinical Reports
Open AccessManagement-changing diagnosis of presumed clamp-related brachiocephalic artery injury by transesophageal echocardiography during total aortic arch replacement: a case report
Background: Aortic arch branch malperfusion during total aortic arch replacement requires prompt diagnosis. We report a case in which transesophageal echocardiography (TEE) clarified discordant intraoperative monitoring findings and directly guided surgical revision. Case presentation: A 77-year-old woman underwent total aortic arch replacement. After separation from cardiopulmonary bypass, right radial arterial pressure and right regional cerebral oxygen saturation markedly decreased, whereas direct brachiocephalic arterial pressure remained preserved. Targeted TEE demonstrated brachiocephalic artery dissection extending into the right common carotid artery with true-lumen compression, loss of antegrade flow into the right subclavian artery, and retrograde vertebral collateral flow. These findings prompted immediate surgical revision. After reconstruction, arterial pressure and cerebral oxygen saturation recovered, and TEE confirmed restoration of antegrade flow. Conclusions: Targeted TEE can clarify discordant monitoring findings in aortic arch branch malperfusion and provide critical information for intraoperative surgical decision-making.
- Open Access
- 6 October 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (44)
Acute Limb Ischemia in the Young
- 6 October 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (44)
Open AccessAcute Limb Ischemia in the Young
- Open Access
- 2 October 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (19) , 7656
Kidney Function Trajectories in Patients with and Without Chronic Kidney Disease Undergoing Transcatheter Aortic Valve Replacement: A Single-Retrospective Cohort Study
Background/Objectives: Transcatheter aortic valve replacement (TAVR) may improve systemic hemodynamics and kidney perfusion; however, its effect on long-term kidney function remains unclear. We evaluated kidney function trajectories before and after TAVR in patients with and without chronic kidney disease (CKD). Methods: This single-center retrospective cohort study included patients with severe aortic stenosis (AS) who underwent TAVR between June 2016 and December 2024. Overall, 314 eligible patients were classified by baseline estimated glomerular filtration rate (eGFR) as without CKD (≥60 mL/min/1.73 m2) or with CKD (2). Linear mixed-effects models estimated pre- and post-TAVR eGFR slopes, which were compared between groups after covariate adjustment. Results: Median follow-up was 2.0 years. Adjusted pre-TAVR eGFR slopes were −2.11 (95% confidence interval [CI], −3.34 to −0.89) mL/min/1.73 m2/year in patients without CKD and −2.83 (95% CI, −3.65 to −2.01) mL/min/1.73 m2/year in patients with CKD. The post-TAVR slopes were −4.02 (95% CI, −5.68 to −2.35) mL/min/1.73 m2/year in patients without CKD and −0.83 (95% CI, −2.04 to 0.39) mL/min/1.73 m2/year in patients with CKD, with a significant group difference of 3.19 (95% CI, 1.44 to 4.94) mL/min/1.73 m2/year (p < 0.001). In patients with CKD, the post-TAVR slope improved relative to the pre-TAVR slope by 2.01 (95% CI, 0.51 to 3.50) mL/min/1.73 m2/year (p < 0.01), whereas no significant change was observed in those without CKD. Conclusions: eGFR decline after TAVR was attenuated in patients with CKD compared with those without CKD, suggesting that kidney function may be preserved through hemodynamic improvement following TAVR.
- 2 October 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (19) , 7656
Open AccessKidney Function Trajectories in Patients with and Without Chronic Kidney Disease Undergoing Transcatheter Aortic Valve Replacement: A Single-Retrospective Cohort Study
Background/Objectives: Transcatheter aortic valve replacement (TAVR) may improve systemic hemodynamics and kidney perfusion; however, its effect on long-term kidney function remains unclear. We evaluated kidney function trajectories before and after TAVR in patients with and without chronic kidney disease (CKD). Methods: This single-center retrospective cohort study included patients with severe aortic stenosis (AS) who underwent TAVR between June 2016 and December 2024. Overall, 314 eligible patients were classified by baseline estimated glomerular filtration rate (eGFR) as without CKD (≥60 mL/min/1.73 m2) or with CKD (2). Linear mixed-effects models estimated pre- and post-TAVR eGFR slopes, which were compared between groups after covariate adjustment. Results: Median follow-up was 2.0 years. Adjusted pre-TAVR eGFR slopes were −2.11 (95% confidence interval [CI], −3.34 to −0.89) mL/min/1.73 m2/year in patients without CKD and −2.83 (95% CI, −3.65 to −2.01) mL/min/1.73 m2/year in patients with CKD. The post-TAVR slopes were −4.02 (95% CI, −5.68 to −2.35) mL/min/1.73 m2/year in patients without CKD and −0.83 (95% CI, −2.04 to 0.39) mL/min/1.73 m2/year in patients with CKD, with a significant group difference of 3.19 (95% CI, 1.44 to 4.94) mL/min/1.73 m2/year (p < 0.001). In patients with CKD, the post-TAVR slope improved relative to the pre-TAVR slope by 2.01 (95% CI, 0.51 to 3.50) mL/min/1.73 m2/year (p < 0.01), whereas no significant change was observed in those without CKD. Conclusions: eGFR decline after TAVR was attenuated in patients with CKD compared with those without CKD, suggesting that kidney function may be preserved through hemodynamic improvement following TAVR.
- Open Access
- 1 September 2026
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 18 (9) , 1080
Less complexity, not less protection: reconsidering cerebral protection during short circulatory arrest in aortic arch surgery
Less complexity, not less protection: reconsidering cerebral protection during short circulatory arrest in aortic arch surgery
- 1 September 2026
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 18 (9) , 1080
Open AccessLess complexity, not less protection: reconsidering cerebral protection during short circulatory arrest in aortic arch surgery
Less complexity, not less protection: reconsidering cerebral protection during short circulatory arrest in aortic arch surgery
- Open Access
- 8 July 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (27) , 109119
From Repair to Valve-in-Valve
- 8 July 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (27) , 109119
Open AccessFrom Repair to Valve-in-Valve
- Open Access
- 25 June 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (7) , 737
Pre-Wetting Reduces Blood Component Deposition on Polyvinyl Alcohol-Coated Poly-ε-Caprolactone Nanofiber Grafts
Hydrophilic surface modification is widely investigated as a strategy to improve the hemocompatibility of small-diameter vascular grafts. We previously developed a polyvinyl alcohol-coated poly-ε-caprolactone nanofiber graft (PVA–PCL graft) and showed that the PVA coating improved graft hydrophilicity and mechanical properties. However, whether this coating provides an in vivo advantage over uncoated PCL grafts remains unclear. In addition, the influence of pre-implantation surface hydration on the function of hydrophilic grafts has not been fully examined. In this study, we first compared PVA–PCL and uncoated PCL grafts in a rat abdominal aorta implantation model and found no statistically significant difference in patency rate between the graft types. We then examined whether pre-wetting enhanced the anti-fouling function of the PVA coating. In vitro whole-blood flushing assays demonstrated that pre-wetting markedly reduced blood component deposition on PVA–PCL grafts, but this effect did not translate into detectable improvements in patency or tissue regeneration in the rat model. These findings indicate that pre-wetting effectively enhances the in vitro anti-fouling behavior of PVA–PCL grafts and may serve as a simple strategy to optimize the functional surface state of hydrophilic coatings. Further studies are needed to determine whether this in vitro improvement can be translated into meaningful enhancement in graft performance in vivo.
- 25 June 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (7) , 737
Open AccessPre-Wetting Reduces Blood Component Deposition on Polyvinyl Alcohol-Coated Poly-ε-Caprolactone Nanofiber Grafts
Hydrophilic surface modification is widely investigated as a strategy to improve the hemocompatibility of small-diameter vascular grafts. We previously developed a polyvinyl alcohol-coated poly-ε-caprolactone nanofiber graft (PVA–PCL graft) and showed that the PVA coating improved graft hydrophilicity and mechanical properties. However, whether this coating provides an in vivo advantage over uncoated PCL grafts remains unclear. In addition, the influence of pre-implantation surface hydration on the function of hydrophilic grafts has not been fully examined. In this study, we first compared PVA–PCL and uncoated PCL grafts in a rat abdominal aorta implantation model and found no statistically significant difference in patency rate between the graft types. We then examined whether pre-wetting enhanced the anti-fouling function of the PVA coating. In vitro whole-blood flushing assays demonstrated that pre-wetting markedly reduced blood component deposition on PVA–PCL grafts, but this effect did not translate into detectable improvements in patency or tissue regeneration in the rat model. These findings indicate that pre-wetting effectively enhances the in vitro anti-fouling behavior of PVA–PCL grafts and may serve as a simple strategy to optimize the functional surface state of hydrophilic coatings. Further studies are needed to determine whether this in vitro improvement can be translated into meaningful enhancement in graft performance in vivo.
- Open Access
- 31 May 2026
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2026 (6) , rjag469
Minimally invasive pulmonary valve replacement via left anterior mini-thoracotomy using an automated fastener-assisted suturing technique: a case report
Chronic pulmonary regurgitation is a late complication after repair of congenital heart disease involving the right ventricular outflow tract. In adult congenital heart disease patients, redo sternotomy carries a risk of cardiac injury due to dense retrosternal adhesions, and minimally invasive approaches have emerged as alternatives. In addition to the surgical approach, prosthetic valve implantation at the posterior pulmonary annulus is technically challenging because knot tying above the valve is difficult in a restricted operative field. We report a 40-year-old man with congenital pulmonary artery dilatation after childhood ventricular septal defect repair who underwent pulmonary valve replacement via left anterior mini-thoracotomy. A 27-mm bioprosthetic valve was implanted in a supra-annular position using interrupted mattress sutures, with an automated knot fastener (Cor-Knot) applied to the posterior annulus. This case demonstrates that minimally invasive pulmonary valve replacement is feasible and reproducible, and that automated fasteners facilitate standard suturing at the posterior pulmonary annulus.
- 31 May 2026
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2026 (6) , rjag469
Open AccessMinimally invasive pulmonary valve replacement via left anterior mini-thoracotomy using an automated fastener-assisted suturing technique: a case report
Chronic pulmonary regurgitation is a late complication after repair of congenital heart disease involving the right ventricular outflow tract. In adult congenital heart disease patients, redo sternotomy carries a risk of cardiac injury due to dense retrosternal adhesions, and minimally invasive approaches have emerged as alternatives. In addition to the surgical approach, prosthetic valve implantation at the posterior pulmonary annulus is technically challenging because knot tying above the valve is difficult in a restricted operative field. We report a 40-year-old man with congenital pulmonary artery dilatation after childhood ventricular septal defect repair who underwent pulmonary valve replacement via left anterior mini-thoracotomy. A 27-mm bioprosthetic valve was implanted in a supra-annular position using interrupted mattress sutures, with an automated knot fastener (Cor-Knot) applied to the posterior annulus. This case demonstrates that minimally invasive pulmonary valve replacement is feasible and reproducible, and that automated fasteners facilitate standard suturing at the posterior pulmonary annulus.
- Open Access
- 19 May 2026
- Published by MDPI AG in Preprints.org
Pre-Wetting Reduces Blood Component Deposition on Polyvinyl Alcohol-Coated Poly-ε-Caprolactone Nanofiber Grafts
Hydrophilic surface modification is widely investigated as a strategy to improve the hemocompatibility of small-diameter vascular grafts. We previously developed a polyvinyl alcohol-coated poly-ε-caprolactone nanofiber graft (PVA–PCL graft) and showed that PVA coating improved graft hydrophilicity and mechanical properties. However, whether PVA coating provides an in vivo advantage over uncoated PCL grafts remains unclear. In addition, the influence of pre-implantation surface hydration on the function of hydrophilic grafts has not been fully examined. In this study, we first compared PVA–PCL and uncoated PCL grafts in a rat abdominal aorta implantation model and found no statistically significant difference in patency rate between the graft types. We then examined whether pre-wetting enhanced the anti-fouling function of the PVA coating. In vitro whole-blood flushing assays demonstrated that pre-wetting markedly reduced blood component deposition on PVA–PCL grafts. However, this effect did not translate into detectable improvements in patency or tissue regeneration in the rat model used in this study. These findings indicate that pre-wetting effectively enhances the in vitro anti-fouling behavior of PVA–PCL grafts and may serve as a simple strategy to optimize the functional surface state of hydrophilic coatings. Further studies are needed to determine whether this in vitro improvement can be translated into meaningful enhancement of graft performance in vivo.
- 19 May 2026
- Published by MDPI AG in Preprints.org
Open AccessPre-Wetting Reduces Blood Component Deposition on Polyvinyl Alcohol-Coated Poly-ε-Caprolactone Nanofiber Grafts
Hydrophilic surface modification is widely investigated as a strategy to improve the hemocompatibility of small-diameter vascular grafts. We previously developed a polyvinyl alcohol-coated poly-ε-caprolactone nanofiber graft (PVA–PCL graft) and showed that PVA coating improved graft hydrophilicity and mechanical properties. However, whether PVA coating provides an in vivo advantage over uncoated PCL grafts remains unclear. In addition, the influence of pre-implantation surface hydration on the function of hydrophilic grafts has not been fully examined. In this study, we first compared PVA–PCL and uncoated PCL grafts in a rat abdominal aorta implantation model and found no statistically significant difference in patency rate between the graft types. We then examined whether pre-wetting enhanced the anti-fouling function of the PVA coating. In vitro whole-blood flushing assays demonstrated that pre-wetting markedly reduced blood component deposition on PVA–PCL grafts. However, this effect did not translate into detectable improvements in patency or tissue regeneration in the rat model used in this study. These findings indicate that pre-wetting effectively enhances the in vitro anti-fouling behavior of PVA–PCL grafts and may serve as a simple strategy to optimize the functional surface state of hydrophilic coatings. Further studies are needed to determine whether this in vitro improvement can be translated into meaningful enhancement of graft performance in vivo.
- Open Access
- 11 April 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (45) , 107849
Strategic Multidisciplinary Management of Aortic Dissection in Fontan Survivors
- 11 April 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (45) , 107849
Open AccessStrategic Multidisciplinary Management of Aortic Dissection in Fontan Survivors
- Open Access
- 4 March 2026
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 13, 1762060
Association of Stanford, DeBakey classification and false-lumen blood flow with age of onset in acute aortic dissection
Background: Younger patients with acute aortic dissection (AAD) are thought to present with distinct anatomical and hemodynamic features compared with older patients. This study evaluated the association between age, dissection extent, and false-lumen flow characteristics in AAD. Methods and results: We retrospectively analyzed 400 consecutive patients with radiologically confirmed AAD from April 2014 to April 2024, categorizing them into a younger group (n = 229) and an older group (≥76 years, n = 171). The distribution of Stanford type A vs. B dissections was similar between groups. However, younger patients more frequently demonstrated DeBakey type I dissection, whereas older patients more commonly had type II. Regarding false-lumen morphology, younger patients showed a higher prevalence of communicating false lumen, while non-communicating patterns predominated in the elderly. Although overall sex distribution of false-lumen types was not significantly different, younger males were more prevalent within each subtype. Preoperative malperfusion occurred more often in younger patients, whereas 30-day mortality did not differ significantly between age groups. Conclusions: Younger AAD patients typically exhibit more extensive dissection and patent false-lumen flow, while older patients more often present with localized dissection and thrombosed false lumen. These age-related distinctions may reflect progressive aortic wall stiffening and should be considered in clinical assessment and management strategies.
- 4 March 2026
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 13, 1762060
Open AccessAssociation of Stanford, DeBakey classification and false-lumen blood flow with age of onset in acute aortic dissection
Background: Younger patients with acute aortic dissection (AAD) are thought to present with distinct anatomical and hemodynamic features compared with older patients. This study evaluated the association between age, dissection extent, and false-lumen flow characteristics in AAD. Methods and results: We retrospectively analyzed 400 consecutive patients with radiologically confirmed AAD from April 2014 to April 2024, categorizing them into a younger group (n = 229) and an older group (≥76 years, n = 171). The distribution of Stanford type A vs. B dissections was similar between groups. However, younger patients more frequently demonstrated DeBakey type I dissection, whereas older patients more commonly had type II. Regarding false-lumen morphology, younger patients showed a higher prevalence of communicating false lumen, while non-communicating patterns predominated in the elderly. Although overall sex distribution of false-lumen types was not significantly different, younger males were more prevalent within each subtype. Preoperative malperfusion occurred more often in younger patients, whereas 30-day mortality did not differ significantly between age groups. Conclusions: Younger AAD patients typically exhibit more extensive dissection and patent false-lumen flow, while older patients more often present with localized dissection and thrombosed false lumen. These age-related distinctions may reflect progressive aortic wall stiffening and should be considered in clinical assessment and management strategies.