Fillitsa V. Karantoni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Fillitsa V. Karantoni has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Michael N. Fardis
Department of Civil Engineering University of Patras Patras Greece
3 shared publications Dionysia Dimakopoulou
University of Patras
2 shared publicationsS.J. Pantazopoulou
2 shared publicationsAthanasios Ganas
National Observatory of Athens
1 shared publicationDimitris N. Sarantitis
1 shared publicationF. N. Lirantzaki
Department of Civil Engineering, University of Patras, Greece
1 shared publication
Latest Publications
- 4 December 2021
- Published by Springer Nature
- p. 892-902
Strengthening Measures for Upgrading the Seismic Response of Gazi Hasan Pasha Mosque, Kos Island
- 4 December 2021
- Published by Springer Nature
- p. 892-902
Strengthening Measures for Upgrading the Seismic Response of Gazi Hasan Pasha Mosque, Kos Island
- 18 November 2020
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 19 (2) , 1213-1230
Displacement-based assessment of the Gazi Hasan Pasha mosque in Kos island (GR) under the 2017 M6.6 earthquake and Eurocode 8, with proposals for upgrading
- 18 November 2020
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 19 (2) , 1213-1230
Displacement-based assessment of the Gazi Hasan Pasha mosque in Kos island (GR) under the 2017 M6.6 earthquake and Eurocode 8, with proposals for upgrading
- 1 December 2019
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 127
Practical assessment of the seismic behavior of a confined masonry system
- 1 December 2019
- Published by Elsevier in Soil Dynamics and Earthquake Engineering
- Vol. 127
Practical assessment of the seismic behavior of a confined masonry system
- 21 August 2019
- Published by Taylor & Francis
- p. 1685-1690
Performance of confined masonry of 1953 during the 2014 Cephalonia earthquake
Cephalonia Island is the region of highest seismicity in Greece. The entire building stock of the island consisting primarily of traditional unreinforced masonry was devastated in 1953 after three strong earthquakes. To house the displaced population of the island the authorities commissioned the development of a system close to what is now known as confined masonry for building new residential dwellings. Several variances to a basic theme were offered with detailed construction plans as alternative options for the reconstruction. In 2014 these buildings sustained with negligible damage two strong ground motions with excessively high ground accelerations that were twice the design value. To better understand and illustrate these practices, the response of these buildings is examined by FEM linear analysis with an emphasis of the effectiveness of these good practices in mitigating the tendencies for localization of deformation demands, which is considered the primary indicator of seismic vulnerability.
- 21 August 2019
- Published by Taylor & Francis
- p. 1685-1690
Performance of confined masonry of 1953 during the 2014 Cephalonia earthquake
Cephalonia Island is the region of highest seismicity in Greece. The entire building stock of the island consisting primarily of traditional unreinforced masonry was devastated in 1953 after three strong earthquakes. To house the displaced population of the island the authorities commissioned the development of a system close to what is now known as confined masonry for building new residential dwellings. Several variances to a basic theme were offered with detailed construction plans as alternative options for the reconstruction. In 2014 these buildings sustained with negligible damage two strong ground motions with excessively high ground accelerations that were twice the design value. To better understand and illustrate these practices, the response of these buildings is examined by FEM linear analysis with an emphasis of the effectiveness of these good practices in mitigating the tendencies for localization of deformation demands, which is considered the primary indicator of seismic vulnerability.
- Open Access
- 30 January 2019
- Published by Bentham Science Publishers Ltd. in The Open Construction & Building Technology Journal
- Vol. 13 (1) , 99-113
Interventions to Structural System of Masonry Buildings and their Effects to their Seismic Response
Background: Preservation of listed buildings, depending on the importance of each one, requires the conservation of the whole structure or of only the external walls, often called shell of the building, or even only of the façade. In the latter cases, although the new structure is studied to undergo the applied loads according to the codes in force, less research is made to study the response of the remaining structure under seismic loads. Objective: The response of unreinforced masonry (URM) structures with alterations of the original load bearing system to strong ground motions is studied in the present paper. Commonly used radical interventions comprise the addition of a steel or reinforced concrete frame in the interior of the structure after removal of interior load bearing or/and dividing walls. The embedded substructure is designed to support the functional loads of the building and commensurate seismic design forces associated with its mass. In this setting, perimeter walls are relieved of any bearing action apart from resisting the state of stress associated with their self-weight. An important design decision is the extent of contact and interaction that is allowed to occur between the perimeter URM walls and the interior structural system; both options present advantages and disadvantages. Methods: The effect that this design option has on the seismic response of the composite system is studied in this paper using linear elastic finite element analysis. The effect of each intervention is estimated by comparing the principal tensile stresses (pts) developed on the walls before and after each intervention as well as the percentage of the wall areas in elevation where the pts are higher than tensile strength of masonry. Results: It is found that connection of the frame to the masonry walls at several points around the floor and roof perimeters creates a diaphragm action that effectively reduces the out-of-plane bending of the self-standing perimeter URM walls without excessive local stress intensities and increases the shear strength of the building. Lack of contact between the old and new load bearing elements leads to higher intensity stresses due to bending and only the addition of a reinforced concrete tie belt at the top of the walls may mitigate serious damage. Conclusions: The cooperation of the Moment Resisting Frames, irrespective of the material of the frame (reinforced concrete or structural steel) and the walls by connecting the perimeter structural walls with it at floor and roof levels, is more efficient to the stress state of the walls transforming the critical out-of-plane bending of later to shear one, preventing them from out-of-plane collapse.
- 30 January 2019
- Published by Bentham Science Publishers Ltd. in The Open Construction & Building Technology Journal
- Vol. 13 (1) , 99-113
Open AccessInterventions to Structural System of Masonry Buildings and their Effects to their Seismic Response
Background: Preservation of listed buildings, depending on the importance of each one, requires the conservation of the whole structure or of only the external walls, often called shell of the building, or even only of the façade. In the latter cases, although the new structure is studied to undergo the applied loads according to the codes in force, less research is made to study the response of the remaining structure under seismic loads. Objective: The response of unreinforced masonry (URM) structures with alterations of the original load bearing system to strong ground motions is studied in the present paper. Commonly used radical interventions comprise the addition of a steel or reinforced concrete frame in the interior of the structure after removal of interior load bearing or/and dividing walls. The embedded substructure is designed to support the functional loads of the building and commensurate seismic design forces associated with its mass. In this setting, perimeter walls are relieved of any bearing action apart from resisting the state of stress associated with their self-weight. An important design decision is the extent of contact and interaction that is allowed to occur between the perimeter URM walls and the interior structural system; both options present advantages and disadvantages. Methods: The effect that this design option has on the seismic response of the composite system is studied in this paper using linear elastic finite element analysis. The effect of each intervention is estimated by comparing the principal tensile stresses (pts) developed on the walls before and after each intervention as well as the percentage of the wall areas in elevation where the pts are higher than tensile strength of masonry. Results: It is found that connection of the frame to the masonry walls at several points around the floor and roof perimeters creates a diaphragm action that effectively reduces the out-of-plane bending of the self-standing perimeter URM walls without excessive local stress intensities and increases the shear strength of the building. Lack of contact between the old and new load bearing elements leads to higher intensity stresses due to bending and only the addition of a reinforced concrete tie belt at the top of the walls may mitigate serious damage. Conclusions: The cooperation of the Moment Resisting Frames, irrespective of the material of the frame (reinforced concrete or structural steel) and the walls by connecting the perimeter structural walls with it at floor and roof levels, is more efficient to the stress state of the walls transforming the critical out-of-plane bending of later to shear one, preventing them from out-of-plane collapse.
- 18 April 2017
- Published by Springer Nature in Frontiers of Structural and Civil Engineering
- Vol. 12 (3) , 270-290
Confined masonry as practical seismic construction alternative–the experience from the 2014 Cephalonia Earthquake
- 18 April 2017
- Published by Springer Nature in Frontiers of Structural and Civil Engineering
- Vol. 12 (3) , 270-290
Confined masonry as practical seismic construction alternative–the experience from the 2014 Cephalonia Earthquake
- 3 November 2016
- Published by Taylor & Francis
- p. 1520-1527
Review of seismic assessment procedures proposed for URM traditional and heritage structures
- 3 November 2016
- Published by Taylor & Francis
- p. 1520-1527
Review of seismic assessment procedures proposed for URM traditional and heritage structures
- 23 June 2016
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 10 (8) , 1055-1077
Simple Seismic Assessment of Traditional Unreinforced Masonry Buildings
A framework for quick seismic assessment and retrofit of traditional unreinforced masonry (URM) structures is presented. The proposed methods build on simple principles of structural dynamics and are used as an alternative to detailed time-history analysis, in recognition of the prevailing need for simple and practical methods, compatible with the low-budget and the limited level of knowledge regarding materials, internal force paths, connectivity and condition of older URM structures. An objective is to identify areas in the building that are particularly susceptible to damage and for guiding the types of the required global interventions to improve seismic response. Demand and supply are expressed in terms of relative drift ratios that quantify the intensity of out-of-plane differential translation and in-plane shear distortion of masonry walls. A characteristic traditional building type of timber-laced masonry is used as a model structure for illustration of concepts. The morphology and geometry of the building correspond to a statistical sample of the actual traditional unreinforced masonry buildings (TURM) found in historical centers of many towns in the greater region of Northern Greece. The methodology is particularly useful for setting retrofit priorities and management of the collective seismic risk of historical entities.
- 23 June 2016
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 10 (8) , 1055-1077
Simple Seismic Assessment of Traditional Unreinforced Masonry Buildings
A framework for quick seismic assessment and retrofit of traditional unreinforced masonry (URM) structures is presented. The proposed methods build on simple principles of structural dynamics and are used as an alternative to detailed time-history analysis, in recognition of the prevailing need for simple and practical methods, compatible with the low-budget and the limited level of knowledge regarding materials, internal force paths, connectivity and condition of older URM structures. An objective is to identify areas in the building that are particularly susceptible to damage and for guiding the types of the required global interventions to improve seismic response. Demand and supply are expressed in terms of relative drift ratios that quantify the intensity of out-of-plane differential translation and in-plane shear distortion of masonry walls. A characteristic traditional building type of timber-laced masonry is used as a model structure for illustration of concepts. The morphology and geometry of the building correspond to a statistical sample of the actual traditional unreinforced masonry buildings (TURM) found in historical centers of many towns in the greater region of Northern Greece. The methodology is particularly useful for setting retrofit priorities and management of the collective seismic risk of historical entities.
- 19 April 2015
- Published by Springer Nature
- p. 429-448
Parametric Seismic Assessment of a Non-symmetric Stone Masonry Building with Flexible Floors
- 19 April 2015
- Published by Springer Nature
- p. 429-448
Parametric Seismic Assessment of a Non-symmetric Stone Masonry Building with Flexible Floors
- 25 June 2014
- Published by Techno-Press in Earthquakes and Structures
- Vol. 6 (6) , 689-713
Seismic fragility of regular masonry buildings for in-plane and out-of-plane failure
- 25 June 2014
- Published by Techno-Press in Earthquakes and Structures
- Vol. 6 (6) , 689-713
Seismic fragility of regular masonry buildings for in-plane and out-of-plane failure