Tomoyuki Ohta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tomoyuki Ohta has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Tatsuya Takayama
Center for Human Reproduction, International University of Health and Welfare Hospital, 537-3 Iguchi, Nasushiobara 329-2763, Tochigi, Japan
3 shared publications - Daisuke Numahata
Department of Urology, International University of Health and Welfare Hospital, Nasushiobara, Japan
2 shared publications Fumio Tsujimoto
2 shared publications- Keita Okamoto
Department of Urology, International University of Health and Welfare Hospital, Nasushiobara, Japan
2 shared publications - Kosuke Kojo
Department of Urology, Institute of Medicine, University of Tsukuba, Tsukuba, Japan
2 shared publications - Kunihiko Fukuda
Department of Radiology, Jikei University, School of Medicine, Tokyo, Japan
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by XMLink in Investigative and Clinical Urology
- Vol. 67 (2) , 178-185
Near infrared ray-guided partial cystectomy using da Vinci Firefly ® technology and intraoperative cystoscopy for urachal cyst, suspected of urachal tumor
Kurobe M, et al. Investig Clin Urol. 2026 Feb;67:e16. https://doi.org/10.4111/icu.20250141
- 1 January 2026
- Published by XMLink in Investigative and Clinical Urology
- Vol. 67 (2) , 178-185
Open AccessNear infrared ray-guided partial cystectomy using da Vinci Firefly ® technology and intraoperative cystoscopy for urachal cyst, suspected of urachal tumor
Kurobe M, et al. Investig Clin Urol. 2026 Feb;67:e16. https://doi.org/10.4111/icu.20250141
- Open Access
- 2 June 2025
- Published by Wiley in BJUI Compass
- Vol. 6 (6)
Incidental crossed fused renal ectopia detected during prostate cancer staging: A photorealistic three‐dimensional rendering
- 2 June 2025
- Published by Wiley in BJUI Compass
- Vol. 6 (6)
Open AccessIncidental crossed fused renal ectopia detected during prostate cancer staging: A photorealistic three‐dimensional rendering
- 24 May 2025
- Published by Elsevier in Clinical Radiology
- Vol. 87, 106973
Morphological changes in the muscle layer associated with invasion of bladder cancer
- 24 May 2025
- Published by Elsevier in Clinical Radiology
- Vol. 87, 106973
Morphological changes in the muscle layer associated with invasion of bladder cancer
- 7 May 2024
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (3) , 465-475
Feasibility of high-frequency ultrasound for seminiferous tubule assessment and correlation of B-mode imaging with pathological findings in the testis in azoospermia
Purpose To determine the feasibility of high-frequency ultrasound (HFUS) for assessing seminiferous tubules and to understand high-resolution B-mode images of the testes in cases of azoospermia. Methods We verified how the histopathological images of testicular biopsy specimens can be observed using HFUS images and measurement analysis of seminiferous tubules was performed to 28 testes of 14 cases with azoospermia who underwent preoperative ultrasound and microdissection testicular sperm extraction (micro-TESE). The population consisted of obstructive azoospermia (OA) and non-obstructive azoospermia (NOA), including Sertoli cell-only syndrome (SCOS), and the other pathologies. Statistical verification of differences in seminiferous tubule diameters among preoperative ultrasound examination, ultrasound examination of pathological specimens, and histopathological specimens. We also examined the imagingpathology correlation via a case series presentation, aiming to identify imaging markers of testicular pathology and determine the possibility of predicting each condition. Results A comparison between HFUS images and histopathology from the same biopsy specimens suggested that ultrasonography could be seen as stereoscopic images due to its significantly greater slice thickness. The diameters of tubules were generally larger in pathological tissues as compared to ultrasonographic findings in OA and SCOS, but not in the other conditions. Comparisons provided insights into the predictability of SCOS and revealed imaging findings such as gaps between tubules and decreased diameter reflective of testicular damage. Conclusion Seminiferous tubules can be observed however the diameter of seminiferous tubules varies in imaging and histopathology depending on the pathology. Imaging findings that reflect testicular damage and the predictability of SCOS were revealed in this study, but further verification is required.
- 7 May 2024
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (3) , 465-475
Feasibility of high-frequency ultrasound for seminiferous tubule assessment and correlation of B-mode imaging with pathological findings in the testis in azoospermia
Purpose To determine the feasibility of high-frequency ultrasound (HFUS) for assessing seminiferous tubules and to understand high-resolution B-mode images of the testes in cases of azoospermia. Methods We verified how the histopathological images of testicular biopsy specimens can be observed using HFUS images and measurement analysis of seminiferous tubules was performed to 28 testes of 14 cases with azoospermia who underwent preoperative ultrasound and microdissection testicular sperm extraction (micro-TESE). The population consisted of obstructive azoospermia (OA) and non-obstructive azoospermia (NOA), including Sertoli cell-only syndrome (SCOS), and the other pathologies. Statistical verification of differences in seminiferous tubule diameters among preoperative ultrasound examination, ultrasound examination of pathological specimens, and histopathological specimens. We also examined the imagingpathology correlation via a case series presentation, aiming to identify imaging markers of testicular pathology and determine the possibility of predicting each condition. Results A comparison between HFUS images and histopathology from the same biopsy specimens suggested that ultrasonography could be seen as stereoscopic images due to its significantly greater slice thickness. The diameters of tubules were generally larger in pathological tissues as compared to ultrasonographic findings in OA and SCOS, but not in the other conditions. Comparisons provided insights into the predictability of SCOS and revealed imaging findings such as gaps between tubules and decreased diameter reflective of testicular damage. Conclusion Seminiferous tubules can be observed however the diameter of seminiferous tubules varies in imaging and histopathology depending on the pathology. Imaging findings that reflect testicular damage and the predictability of SCOS were revealed in this study, but further verification is required.
- Open Access
- 3 April 2024
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (3) , 553
Correction: Characterization of breast changes in the early gestational period on automated breast ultrasound
- 3 April 2024
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (3) , 553
Open AccessCorrection: Characterization of breast changes in the early gestational period on automated breast ultrasound
- Open Access
- 24 October 2023
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (1) , 103-108
Characterization of breast changes in the early gestational period on automated breast ultrasound
Purpose: This study was conducted to determine the characteristics of milk duct development in early pregnancy on ultrasound images. Methods: Automated breast ultrasound (ABUS) images used for breast cancer screening in 332 pregnant women were evaluated retrospectively to determine when and how ductal development becomes evident on ultrasonography. The diagnostic criteria used for mammary gland changes during the gestational period were extension of the ducts to the margins of the breast where little or no echogenic fibroglandular tissue is seen on sonograms and/or the appearance of ductal structures running along the ascending Cooper’s ligament tapering off or ending in a blind end at the superficial layer of the superficial fascia. The correlations between gestational stage and the prevalence of these criteria were verified by Spearman’s rank correlation coefficient (ρ). Assessments were performed by a single radiologist with experience reading ABUS images. Results: With a few exceptions, the prevalence of the above findings increased sharply beginning at 10 weeks, and then increased with progression of gestation, reaching a plateau after 20 weeks (ρ = 0.766, P < 0.00001). Conclusion: The findings in this study suggested that development of the milk ducts in early pregnancy can be observed using ABUS. These findings will be useful to gain a better understanding of breast ultrasound imaging characteristics during pregnancy.
- 24 October 2023
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (1) , 103-108
Open AccessCharacterization of breast changes in the early gestational period on automated breast ultrasound
Purpose: This study was conducted to determine the characteristics of milk duct development in early pregnancy on ultrasound images. Methods: Automated breast ultrasound (ABUS) images used for breast cancer screening in 332 pregnant women were evaluated retrospectively to determine when and how ductal development becomes evident on ultrasonography. The diagnostic criteria used for mammary gland changes during the gestational period were extension of the ducts to the margins of the breast where little or no echogenic fibroglandular tissue is seen on sonograms and/or the appearance of ductal structures running along the ascending Cooper’s ligament tapering off or ending in a blind end at the superficial layer of the superficial fascia. The correlations between gestational stage and the prevalence of these criteria were verified by Spearman’s rank correlation coefficient (ρ). Assessments were performed by a single radiologist with experience reading ABUS images. Results: With a few exceptions, the prevalence of the above findings increased sharply beginning at 10 weeks, and then increased with progression of gestation, reaching a plateau after 20 weeks (ρ = 0.766, P < 0.00001). Conclusion: The findings in this study suggested that development of the milk ducts in early pregnancy can be observed using ABUS. These findings will be useful to gain a better understanding of breast ultrasound imaging characteristics during pregnancy.
- Open Access
- 1 January 2021
- Published by Medknow in Journal of Medical Ultrasound
- Vol. 29 (1) , 50-52
In vitro Demonstration of Melanoma Metastasis in Lymph Nodes of Prepared Specimens Using a Light-emitting Diode-based Multispectral Photoacoustic Ultrasound Imaging System
Although an excellent photoacoustic (PA) ultrasound method has been reported for the evaluation of lymph node melanoma metastasis in animal experiments, it remains to be evaluated in clinical trials. Recently, we performed PA ultrasound assessment using light-emitting diodes to detect metastatic melanoma in the lymph nodes of specimens prepared for microscopic examination. The PA effect was not obvious in amelanotic melanoma, but was seen in melanotic melanoma by PA imaging (PAI) and histopathological correlation in cases of primary melanotic melanoma accompanied by metastatic lymph nodes, including the coexistence of amelanotic melanoma and melanotic melanoma. Clinical workup should be performed with not only PAI but also conventional ultrasonography in cases with metastasis related to amelanotic transformation, which would likely be missed by PAI alone.
- 1 January 2021
- Published by Medknow in Journal of Medical Ultrasound
- Vol. 29 (1) , 50-52
Open AccessIn vitro Demonstration of Melanoma Metastasis in Lymph Nodes of Prepared Specimens Using a Light-emitting Diode-based Multispectral Photoacoustic Ultrasound Imaging System
Although an excellent photoacoustic (PA) ultrasound method has been reported for the evaluation of lymph node melanoma metastasis in animal experiments, it remains to be evaluated in clinical trials. Recently, we performed PA ultrasound assessment using light-emitting diodes to detect metastatic melanoma in the lymph nodes of specimens prepared for microscopic examination. The PA effect was not obvious in amelanotic melanoma, but was seen in melanotic melanoma by PA imaging (PAI) and histopathological correlation in cases of primary melanotic melanoma accompanied by metastatic lymph nodes, including the coexistence of amelanotic melanoma and melanotic melanoma. Clinical workup should be performed with not only PAI but also conventional ultrasonography in cases with metastasis related to amelanotic transformation, which would likely be missed by PAI alone.
- 27 June 2017
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 45 (1) , 81-87
Significance of perithyroidal lymph nodes in benign thyroid diseases
The incidences of perithyroidal lymph nodes (PTLNs) in benign thyroid diseases were investigated.
- 27 June 2017
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 45 (1) , 81-87
Significance of perithyroidal lymph nodes in benign thyroid diseases
The incidences of perithyroidal lymph nodes (PTLNs) in benign thyroid diseases were investigated.
- 25 July 2015
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 33 (9) , 559-565
Quantitative differentiation of benign and malignant mammographic circumscribed masses using intensity histograms
To investigate the usefulness of density gradient of mammographic masses for differentiating benign from malignant lesions, particularly circumscribed masses, which are difficult to diagnose by shape. Phantom experiments were performed and diagnostic mammography examinations were reviewed. Mammograms of three acrylic resin globes differing in hardness were acquired with/without applied pressure, and density gradients were examined on intensity histograms with standard deviation (SD) as a hardness index. Similar analyses were performed using clinical mammographic examinations of circumscribed mass lesions. The usefulness of SD for differentiating between benign and malignant lesions was investigated by ROC curve analysis and minimum/maximum values of malignant and benign lesions, respectively. For circumscribed masses (n = 196, benign, n = 176; malignant, n = 20), ROC analysis showed AUC = 0.786, with sensitivity = 70.0 %, specificity = 70.5 %, accuracy = 70.4 %, positive predictive value = 21.1 %, and negative predictive value = 95.4 % at SD = 64.46. Minimum and maximum SD of malignant and benign masses were 39.1 and 241.7, respectively. On mammography, circumscribed masses can be diagnosed with moderate accuracy using the intensity histogram SD. Masses with SD below the minimum of breast cancer can be roughly diagnosed as clinically benign.
- 25 July 2015
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 33 (9) , 559-565
Quantitative differentiation of benign and malignant mammographic circumscribed masses using intensity histograms
To investigate the usefulness of density gradient of mammographic masses for differentiating benign from malignant lesions, particularly circumscribed masses, which are difficult to diagnose by shape. Phantom experiments were performed and diagnostic mammography examinations were reviewed. Mammograms of three acrylic resin globes differing in hardness were acquired with/without applied pressure, and density gradients were examined on intensity histograms with standard deviation (SD) as a hardness index. Similar analyses were performed using clinical mammographic examinations of circumscribed mass lesions. The usefulness of SD for differentiating between benign and malignant lesions was investigated by ROC curve analysis and minimum/maximum values of malignant and benign lesions, respectively. For circumscribed masses (n = 196, benign, n = 176; malignant, n = 20), ROC analysis showed AUC = 0.786, with sensitivity = 70.0 %, specificity = 70.5 %, accuracy = 70.4 %, positive predictive value = 21.1 %, and negative predictive value = 95.4 % at SD = 64.46. Minimum and maximum SD of malignant and benign masses were 39.1 and 241.7, respectively. On mammography, circumscribed masses can be diagnosed with moderate accuracy using the intensity histogram SD. Masses with SD below the minimum of breast cancer can be roughly diagnosed as clinically benign.
- Open Access
- 1 June 2015
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 34 (6) , 1131-1137
Five Cases of Axillary Lymph Node Metastatic Breast Cancer on Contrast-Enhanced Sonography
- 1 June 2015
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 34 (6) , 1131-1137
Open AccessFive Cases of Axillary Lymph Node Metastatic Breast Cancer on Contrast-Enhanced Sonography