Ali Mert Koçer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ali Mert Koçer has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Mehmet Ali Sekeroglu
Ophthalmology Department, Ulucanlar Eye Training and Research Hospital, Ankara, Turkey
4 shared publications Arzu Yılmaz
Department, Ankara Training and Research Hospital, Ankara, Turkey
3 shared publicationsMine Turkay
Department, Etlik Integrated Health Campus, Ankara, Turkey
3 shared publications- Çağatay Emir Önder
Ankara Eğitim ve Araştırma Hastanesi
3 shared publications - Şerife Mehlika Kuşkonmaz
Ankara Eğitim ve Araştırma Hastanesi
3 shared publications Ali Mert Koçer
Department of Ophthalmology, Ulucanlar Eye Training and Research Hospital, Ankara, Turkey.
2 shared publications
Latest Publications
- 8 July 2026
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 35 (11) , 853-858
Photopic Negative Response in Pseudoexfoliation Syndrome and Pseudoexfoliative Glaucoma
Précis: PhNR amplitudes and implicit times demonstrated graded functional impairment from controls to PXS and PXG, highlighting PhNR as a sensitive tool for detecting early inner retinal dysfunction and differentiating pseudoexfoliation stages. Purpose: To evaluate photopic negative response (PhNR) parameters across the pseudoexfoliation spectrum and determine whether PhNR can identify early retinal ganglion cell dysfunction in pseudoexfoliation syndrome (PXS) before the onset of pseudoexfoliative glaucoma (PXG). Methods: This cross-sectional study included 93 eyes: 35 with PXG, 28 with PXS, and 30 healthy controls. PhNR was recorded using an extended ISCEV protocol with red-on-blue full-field electroretinography. PhNR peak-to-trough (PT) and baseline-to-trough (BT) amplitudes and implicit times were measured. Group comparisons, correlation analyses with visual field indices, and receiver operating characteristic (ROC) analyses were performed. Results: PXG eyes exhibited significantly prolonged implicit times and reduced amplitudes in a-wave, b-wave, i-wave, and PhNR measures compared with both PXS and control eyes (all P P r =–0.537, P =0.015) and VFI ( r =−0.501, P =0.024), while PhNR PT amplitude correlated positively with VFI ( r =0.591, P =0.006). ROC analysis indicated that PhNR PT amplitude as the strongest discriminator between PXG and controls (AUC=0.908, P P =0.011; AUC=0.664, P =0.028, respectively). Conclusion: PhNR effectively detected inner retinal dysfunction across the pseudoexfoliation spectrum and showed a progressive decrease from controls to PXS and PXG. PhNR may serve as a valuable adjunctive biomarker for risk stratification and early detection of glaucomatous transformation in PXS.
- 8 July 2026
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 35 (11) , 853-858
Photopic Negative Response in Pseudoexfoliation Syndrome and Pseudoexfoliative Glaucoma
Précis: PhNR amplitudes and implicit times demonstrated graded functional impairment from controls to PXS and PXG, highlighting PhNR as a sensitive tool for detecting early inner retinal dysfunction and differentiating pseudoexfoliation stages. Purpose: To evaluate photopic negative response (PhNR) parameters across the pseudoexfoliation spectrum and determine whether PhNR can identify early retinal ganglion cell dysfunction in pseudoexfoliation syndrome (PXS) before the onset of pseudoexfoliative glaucoma (PXG). Methods: This cross-sectional study included 93 eyes: 35 with PXG, 28 with PXS, and 30 healthy controls. PhNR was recorded using an extended ISCEV protocol with red-on-blue full-field electroretinography. PhNR peak-to-trough (PT) and baseline-to-trough (BT) amplitudes and implicit times were measured. Group comparisons, correlation analyses with visual field indices, and receiver operating characteristic (ROC) analyses were performed. Results: PXG eyes exhibited significantly prolonged implicit times and reduced amplitudes in a-wave, b-wave, i-wave, and PhNR measures compared with both PXS and control eyes (all P P r =–0.537, P =0.015) and VFI ( r =−0.501, P =0.024), while PhNR PT amplitude correlated positively with VFI ( r =0.591, P =0.006). ROC analysis indicated that PhNR PT amplitude as the strongest discriminator between PXG and controls (AUC=0.908, P P =0.011; AUC=0.664, P =0.028, respectively). Conclusion: PhNR effectively detected inner retinal dysfunction across the pseudoexfoliation spectrum and showed a progressive decrease from controls to PXS and PXG. PhNR may serve as a valuable adjunctive biomarker for risk stratification and early detection of glaucomatous transformation in PXS.
- Open Access
- 27 April 2026
- Published by Galenos Yayinevi in Turkish Journal of Ophthalmology
- Vol. 56 (2) , 131-134
Suture Revision for the Management of Postoperative Intraocular Pressure Spike Following Cyclodialysis Repair in Chronic Five-Year Hypotony
Suture Revision for the Management of Postoperative Intraocular Pressure Spike Following Cyclodialysis Repair in Chronic Five-Year Hypotony - Turkish Journal of Ophthalmology
- 27 April 2026
- Published by Galenos Yayinevi in Turkish Journal of Ophthalmology
- Vol. 56 (2) , 131-134
Open AccessSuture Revision for the Management of Postoperative Intraocular Pressure Spike Following Cyclodialysis Repair in Chronic Five-Year Hypotony
Suture Revision for the Management of Postoperative Intraocular Pressure Spike Following Cyclodialysis Repair in Chronic Five-Year Hypotony - Turkish Journal of Ophthalmology
- Open Access
- 27 October 2025
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 263 (12) , 3593
Letter to the editor regarding “Investigation of laser peripheral iridotomy characteristics using the ImageJ program on anterior segment parameters”
- 27 October 2025
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 263 (12) , 3593
Open AccessLetter to the editor regarding “Investigation of laser peripheral iridotomy characteristics using the ImageJ program on anterior segment parameters”
- 22 September 2025
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 264 (1) , 185-194
Investigation of laser peripheral iridotomy characteristics using the ImageJ program on anterior segment parameters
Purpose This study aimed to evaluate the characteristics of laser peripheral iridotomy (LPI), including area size, location, and distance from the pupil center, using ImageJ software, and to explore their correlation with changes in anterior segment parameters observed through Pentacam imaging. Methods This retrospective study analyzed 29 eyes of 29 patients with angle-closure who underwent LPI between April 2023 and December 2024. Patients diagnosed with primary angle-closure glaucoma, primary angle closure, and high-risk primary angle-closure suspects were included. Anterior segment parameters were assessed pre- and post-LPI using Pentacam imaging. ImageJ software was used to analyze anterior segment photographs to assess LPI characteristics, including the area size, location, and distance from the center of the pupil. Results Following LPI, significant increases were observed in superior (0.93 to 1.00 mm), inferior (1.12 ± 0.20 to 1.26 ± 0.19 mm), temporal (1.23 ± 0.20 to 1.36 ± 0.17 mm), and nasal (1.0 to 1.06 mm) peripheral anterior chamber depths (ACD), anterior chamber volume (ACV) (74.1 ± 13.5 to 84.6 ± 10.8 mm3), and anterior chamber angle (20.4 ± 4.1º to 23.4 ± 4.4º) (p < 0.05, for all), while central ACD (1.92 ± 0.21 to 1.91 ± 0.20 mm) remained unchanged (p = 0.432). The mean intraocular pressure decreased significantly from 18.6 ± 4.2 mmHg to 16.6 ± 3.3 mmHg (p < 0.001). Negative correlations were found between increases in superior and temporal peripheral ACDs and the pupil-to-LPI area ratio (p < 0.05 for all). Additionally, ACV improvement was negatively correlated with the LPI distance (β=-0.531, p = 0.013). Conclusion The characteristics of the LPI, specifically the pupil-to-LPI area ratio and the LPI distance from the pupil, may significantly influence changes in anterior segment parameters. A small LPI area relative to the pupil area and excessively peripheral LPI locations may be associated with reduced treatment efficacy. These findings may highlight the importance of considering both pupil size and the precise positioning of the LPI to optimize therapeutic outcomes.
- 22 September 2025
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 264 (1) , 185-194
Investigation of laser peripheral iridotomy characteristics using the ImageJ program on anterior segment parameters
Purpose This study aimed to evaluate the characteristics of laser peripheral iridotomy (LPI), including area size, location, and distance from the pupil center, using ImageJ software, and to explore their correlation with changes in anterior segment parameters observed through Pentacam imaging. Methods This retrospective study analyzed 29 eyes of 29 patients with angle-closure who underwent LPI between April 2023 and December 2024. Patients diagnosed with primary angle-closure glaucoma, primary angle closure, and high-risk primary angle-closure suspects were included. Anterior segment parameters were assessed pre- and post-LPI using Pentacam imaging. ImageJ software was used to analyze anterior segment photographs to assess LPI characteristics, including the area size, location, and distance from the center of the pupil. Results Following LPI, significant increases were observed in superior (0.93 to 1.00 mm), inferior (1.12 ± 0.20 to 1.26 ± 0.19 mm), temporal (1.23 ± 0.20 to 1.36 ± 0.17 mm), and nasal (1.0 to 1.06 mm) peripheral anterior chamber depths (ACD), anterior chamber volume (ACV) (74.1 ± 13.5 to 84.6 ± 10.8 mm3), and anterior chamber angle (20.4 ± 4.1º to 23.4 ± 4.4º) (p < 0.05, for all), while central ACD (1.92 ± 0.21 to 1.91 ± 0.20 mm) remained unchanged (p = 0.432). The mean intraocular pressure decreased significantly from 18.6 ± 4.2 mmHg to 16.6 ± 3.3 mmHg (p < 0.001). Negative correlations were found between increases in superior and temporal peripheral ACDs and the pupil-to-LPI area ratio (p < 0.05 for all). Additionally, ACV improvement was negatively correlated with the LPI distance (β=-0.531, p = 0.013). Conclusion The characteristics of the LPI, specifically the pupil-to-LPI area ratio and the LPI distance from the pupil, may significantly influence changes in anterior segment parameters. A small LPI area relative to the pupil area and excessively peripheral LPI locations may be associated with reduced treatment efficacy. These findings may highlight the importance of considering both pupil size and the precise positioning of the LPI to optimize therapeutic outcomes.
- 20 June 2025
- Published by Springer Nature in International Ophthalmology
- Vol. 45 (1) , 1-8
Evaluation of corneal and anterior segment alterations following short-term use of topical latanoprostene bunod
Purpose This study aimed to evaluate the short-term effects of topical latanoprostene bunod on corneal and anterior segment parameters in patients with primary open-angle glaucoma (POAG). Methods A prospective, cross-sectional study was conducted on 30 eyes of 30 patients with POAG. All participants received topical latanoprostene bunod monotherapy. Corneal and anterior segment parameters, including keratometry, corneal thickness, endothelial cell characteristics, and corneal densitometry, were measured before and approximately after one month of treatment using the Pentacam HR and non-contact specular microscopy. Statistical analysis was performed to compare pre- and post-treatment measurements. Results No significant changes were observed in corneal keratometry, endothelial cell density, hexagonality, or anterior chamber parameters including anterior chamber angle, depth, and volume following treatment (p > 0.05 for all). Although reductions in central corneal thickness and thinnest corneal thickness were noted, these changes were not statistically significant (p > 0.05 for both). A significant decrease in densitometric parameters was observed in most corneal zones after treatment, including anterior, central, posterior, and total thickness measurements (p < 0.05 for all). In contrast, no significant change was found in the peripheral 10–12 mm zones (p > 0.05 for all). Conclusion Short-term use of latanoprostene bunod reduced corneal densitometry values, suggesting improved corneal transparency without significantly affecting corneal thickness, endothelial cell characteristics, or anterior segment parameters. Further long-term studies with larger sample sizes are needed to evaluate its prolonged effects on corneal health.
- 20 June 2025
- Published by Springer Nature in International Ophthalmology
- Vol. 45 (1) , 1-8
Evaluation of corneal and anterior segment alterations following short-term use of topical latanoprostene bunod
Purpose This study aimed to evaluate the short-term effects of topical latanoprostene bunod on corneal and anterior segment parameters in patients with primary open-angle glaucoma (POAG). Methods A prospective, cross-sectional study was conducted on 30 eyes of 30 patients with POAG. All participants received topical latanoprostene bunod monotherapy. Corneal and anterior segment parameters, including keratometry, corneal thickness, endothelial cell characteristics, and corneal densitometry, were measured before and approximately after one month of treatment using the Pentacam HR and non-contact specular microscopy. Statistical analysis was performed to compare pre- and post-treatment measurements. Results No significant changes were observed in corneal keratometry, endothelial cell density, hexagonality, or anterior chamber parameters including anterior chamber angle, depth, and volume following treatment (p > 0.05 for all). Although reductions in central corneal thickness and thinnest corneal thickness were noted, these changes were not statistically significant (p > 0.05 for both). A significant decrease in densitometric parameters was observed in most corneal zones after treatment, including anterior, central, posterior, and total thickness measurements (p < 0.05 for all). In contrast, no significant change was found in the peripheral 10–12 mm zones (p > 0.05 for all). Conclusion Short-term use of latanoprostene bunod reduced corneal densitometry values, suggesting improved corneal transparency without significantly affecting corneal thickness, endothelial cell characteristics, or anterior segment parameters. Further long-term studies with larger sample sizes are needed to evaluate its prolonged effects on corneal health.
- Open Access
- 2 January 2025
- Published by Galenos Yayinevi in Turkish Journal of Ophthalmology
- Vol. 54 (6) , 364-368
Nd:YAG Laser Application for the Treatment of Retained Lens Fragment in the Anterior Chamber Following Cataract Surgery
Nd:YAG Laser Application for the Treatment of Retained Lens Fragment in the Anterior Chamber Following Cataract Surgery - Turkish Journal of Ophthalmology
- 2 January 2025
- Published by Galenos Yayinevi in Turkish Journal of Ophthalmology
- Vol. 54 (6) , 364-368
Open AccessNd:YAG Laser Application for the Treatment of Retained Lens Fragment in the Anterior Chamber Following Cataract Surgery
Nd:YAG Laser Application for the Treatment of Retained Lens Fragment in the Anterior Chamber Following Cataract Surgery - Turkish Journal of Ophthalmology
- 12 November 2024
- Published by Springer Nature in International Ophthalmology
- Vol. 44 (1) , 1-7
Static and dynamic pupillary features in graves disease without orbitopathy
Purpose Pupillary contraction and dilatation are organized by the autonomic nervous system, which can also be affected by Graves' disease (GD). In this study, it was aimed to investigate the static and dynamic pupillary responses of Graves' patients in the hyperthyroid and euthyroid periods and to compare these results with the values obtained from healthy controls. Methods 48 eyes of 24 newly diagnosed Graves' patients with clinical activity score ≤ 2 and 46 eyes of 23 age- and sex-matched healthy controls were included in the study. Patients with GD were evaluated separately in the hyperthyroid phase and after euthyroidism was achieved. After a detailed ophthalmological examination, patients undergone automatic quantitative testing to obtain static (scotopic, mesopic, low photopic, and high photopeak pupil diameters) and dynamic (pupillary contraction amplitude, latency, velocity and duration, and pupil dilation latency, velocity and duration) pupil measurements. Results A statistically significant difference was found between the control [4.7 mm (3.7–6.9)] and hyperthyroid [5.1 mm (3.6–7.8)] groups for mesopic pupil diameter (p = 0.003). Dynamic pupillometry measurements showed that hyperthyroid and euthyroid groups had greater pupil dilation delay and lower pupil dilation rate compared to the control group (p < 0.05 for all). Conclusion Even in the absence of orbitopathy, patients with GD have autonomic dysregulation of pupillary functions. These changes, which prevail in the hyperthyroid phase, do not reverse when the TSH receptor antibody titer drops and the patient becomes euthyroid. Future studies are needed to elucidate the mechanism of these pupillary changes in GD.
- 12 November 2024
- Published by Springer Nature in International Ophthalmology
- Vol. 44 (1) , 1-7
Static and dynamic pupillary features in graves disease without orbitopathy
Purpose Pupillary contraction and dilatation are organized by the autonomic nervous system, which can also be affected by Graves' disease (GD). In this study, it was aimed to investigate the static and dynamic pupillary responses of Graves' patients in the hyperthyroid and euthyroid periods and to compare these results with the values obtained from healthy controls. Methods 48 eyes of 24 newly diagnosed Graves' patients with clinical activity score ≤ 2 and 46 eyes of 23 age- and sex-matched healthy controls were included in the study. Patients with GD were evaluated separately in the hyperthyroid phase and after euthyroidism was achieved. After a detailed ophthalmological examination, patients undergone automatic quantitative testing to obtain static (scotopic, mesopic, low photopic, and high photopeak pupil diameters) and dynamic (pupillary contraction amplitude, latency, velocity and duration, and pupil dilation latency, velocity and duration) pupil measurements. Results A statistically significant difference was found between the control [4.7 mm (3.7–6.9)] and hyperthyroid [5.1 mm (3.6–7.8)] groups for mesopic pupil diameter (p = 0.003). Dynamic pupillometry measurements showed that hyperthyroid and euthyroid groups had greater pupil dilation delay and lower pupil dilation rate compared to the control group (p < 0.05 for all). Conclusion Even in the absence of orbitopathy, patients with GD have autonomic dysregulation of pupillary functions. These changes, which prevail in the hyperthyroid phase, do not reverse when the TSH receptor antibody titer drops and the patient becomes euthyroid. Future studies are needed to elucidate the mechanism of these pupillary changes in GD.
- Open Access
- 25 October 2024
- Published by Galenos Yayinevi in Turkish Journal of Ophthalmology
- Vol. 54 (5) , 309-312
Conjunctival Collagen Cross-Linking for the Treatment of Leaking Avascular Cystic Bleb
Conjunctival Collagen Cross-Linking for the Treatment of Leaking Avascular Cystic Bleb - Turkish Journal of Ophthalmology
- 25 October 2024
- Published by Galenos Yayinevi in Turkish Journal of Ophthalmology
- Vol. 54 (5) , 309-312
Open AccessConjunctival Collagen Cross-Linking for the Treatment of Leaking Avascular Cystic Bleb
Conjunctival Collagen Cross-Linking for the Treatment of Leaking Avascular Cystic Bleb - Turkish Journal of Ophthalmology
- Open Access
- 29 August 2024
- Published by Galenos Yayinevi in Turkish Journal of Ophthalmology
- Vol. 54 (4) , 183-189
An Investigation of the Psychosocial Outcomes of Dry Eye Disease Treatment in Children with Computer Vision Syndrome
An Investigation of the Psychosocial Outcomes of Dry Eye Disease Treatment in Children with Computer Vision Syndrome - Turkish Journal of Ophthalmology
- 29 August 2024
- Published by Galenos Yayinevi in Turkish Journal of Ophthalmology
- Vol. 54 (4) , 183-189
Open AccessAn Investigation of the Psychosocial Outcomes of Dry Eye Disease Treatment in Children with Computer Vision Syndrome
An Investigation of the Psychosocial Outcomes of Dry Eye Disease Treatment in Children with Computer Vision Syndrome - Turkish Journal of Ophthalmology
- 6 September 2023
- Published by Dokuz Eylul Universitesi Tip Fakultesi Dergisi in Dokuz Eylül Üniversitesi Tıp Fakültesi Dergisi
- Vol. 37 (2) , 111-121
Hipotiroidizm Tanılı Hastalarda Levotiroksin Tedavisinin Oküler Vasküler Sistem Üzerine Etkilerinin İncelenmesi.
Amaç: Sistemik vasküler değişikliklerin görülebildiği hipotiroidizm, tiroid hormonlarının yetersiz salgılanması ile karakterize endokrin sistem hastalığıdır. Bu çalışmada primer hipotiroidisi olan hastaların hipotiroid ve ötiroid dönemlerinde retina ve koroid vasküler değişikliklerinin kantitatif olarak optik koherens tomografi anjiografi (OKTA) ile incelenmesi amaçlandı. Gereç ve Yöntemler: Aşikar veya tedavi gerektiren subklinik hipotiroidisi olan 20 hastanın 40 gözü çalışmaya dahil edildi. Hastalar hipotiroid ve levotiroksin tedavisi sonrası ötiroid dönemde OKTA ile değerlendirildi. OKTA cihazı ile foveal avasküler zon (FAZ) ve koryokapillaris akım (KA) değerleri ile yüzeyel kapiller pleksus (YKP), derin kapiller pleksus (DKP)ve radyal peripapiller kapiller pleksus (RPKP) vasküler dansite verileri elde edildi. Bulgular: YKP, DKP ve RPKP vasküler dansite değerlerinde hipotiroid ve ötiroid dönemler arasında istatistiksel olarak anlamlı fark saptanmadı (tümü için p>0,05). 1,2 ve 3 mm tarama paternleri kullanılarak yapılan KA ölçümlerinde ise ötiroid dönemde hipotiroid döneme göre istatistiksel anlamlı artış görüldü (sırasıyla p=0,037; p=0,035; p=0,021). 1 ve 2 mm KA değerleri ötiroid dönemdeki sT4 düzeyleri ile pozitif korelasyon gösterirken (r=0,596; p< 0,001 ve r=0,402; p=0,012); 1 mm KA ölçümleri ile hasta yaşı ve ötiroid dönemdeki TSH düzeyleri arasında negatif korelasyon saptandı (r=-0,380; p= 0,016 ve r=-0,351; p=0,031). Sonuç: Bu çalışmada ötiroid dönemde hipotiroid dönemle karşılaştırıldığında artmış KA hızı saptanmıştır. Bu değişikliklerin hipotroidide görülebilen sistemik vasküler değişiklikler ile ilişkili olabileceği ve hipotroidi tanılı hastalarda olası vasküler etkilerin saptanmasında OKTA ile oküler akımın değerlendirilmesinin önemli olduğu düşünülmektedir.
- 6 September 2023
- Published by Dokuz Eylul Universitesi Tip Fakultesi Dergisi in Dokuz Eylül Üniversitesi Tıp Fakültesi Dergisi
- Vol. 37 (2) , 111-121
Hipotiroidizm Tanılı Hastalarda Levotiroksin Tedavisinin Oküler Vasküler Sistem Üzerine Etkilerinin İncelenmesi.
Amaç: Sistemik vasküler değişikliklerin görülebildiği hipotiroidizm, tiroid hormonlarının yetersiz salgılanması ile karakterize endokrin sistem hastalığıdır. Bu çalışmada primer hipotiroidisi olan hastaların hipotiroid ve ötiroid dönemlerinde retina ve koroid vasküler değişikliklerinin kantitatif olarak optik koherens tomografi anjiografi (OKTA) ile incelenmesi amaçlandı. Gereç ve Yöntemler: Aşikar veya tedavi gerektiren subklinik hipotiroidisi olan 20 hastanın 40 gözü çalışmaya dahil edildi. Hastalar hipotiroid ve levotiroksin tedavisi sonrası ötiroid dönemde OKTA ile değerlendirildi. OKTA cihazı ile foveal avasküler zon (FAZ) ve koryokapillaris akım (KA) değerleri ile yüzeyel kapiller pleksus (YKP), derin kapiller pleksus (DKP)ve radyal peripapiller kapiller pleksus (RPKP) vasküler dansite verileri elde edildi. Bulgular: YKP, DKP ve RPKP vasküler dansite değerlerinde hipotiroid ve ötiroid dönemler arasında istatistiksel olarak anlamlı fark saptanmadı (tümü için p>0,05). 1,2 ve 3 mm tarama paternleri kullanılarak yapılan KA ölçümlerinde ise ötiroid dönemde hipotiroid döneme göre istatistiksel anlamlı artış görüldü (sırasıyla p=0,037; p=0,035; p=0,021). 1 ve 2 mm KA değerleri ötiroid dönemdeki sT4 düzeyleri ile pozitif korelasyon gösterirken (r=0,596; p< 0,001 ve r=0,402; p=0,012); 1 mm KA ölçümleri ile hasta yaşı ve ötiroid dönemdeki TSH düzeyleri arasında negatif korelasyon saptandı (r=-0,380; p= 0,016 ve r=-0,351; p=0,031). Sonuç: Bu çalışmada ötiroid dönemde hipotiroid dönemle karşılaştırıldığında artmış KA hızı saptanmıştır. Bu değişikliklerin hipotroidide görülebilen sistemik vasküler değişiklikler ile ilişkili olabileceği ve hipotroidi tanılı hastalarda olası vasküler etkilerin saptanmasında OKTA ile oküler akımın değerlendirilmesinin önemli olduğu düşünülmektedir.