SASantiago Harald Andany

Santiago Harald Andany

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Santiago Harald Andany has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Compensating nonlinearities in high-speed atomic force microscopy using data-driven feedforward controller design

    by Navid Asmari, Veronika Cencen, Mustafa Kangül, Santiago Harald Andany, Cem Tekin, Maartje Martina Cornelia Bastings, Alireza Karimi, Georg Ernest Fantner

    Piezoelectric actuators are widely used in nano-positioning stage of atomic force microscopes (AFM). The nonlinear dynamics of these actuators adversely affect the AFM image quality unless they are compensated with a controller. We propose a feedforward controller design method which adjusts the scan waveforms with the aim of minimizing the hysteresis distortions in the lateral direction of motion. The data-driven design approach requires a pair of forward and backward stripes of images of the sample to detect the hysteresis mappings through solving a nonlinear optimization problem with a genetic algorithm. The parameters of the optimization are then used to shape the scan waveforms to compensate for the effects of hysteresis. The quick and straightforward design makes the proposed feedforward controller a good solution for lateral scanners in high-speed AFM where implementation of feedback control is often hindered by the physical constraints and latency of the system. We show that the design procedure can be successfully applied on AFM instruments regardless of the imaging mode, scan speed, or the sample under study.


  • Open Access

    A hermetically closed sample chamber enables time-lapse nano-characterization of pathogenic microorganisms in vitro

    by Esther Braun, Santiago H. Andany, Mustafa Kangül, Navid S. Asmari, John D. McKinney, Georg Ernest Fantner

    A safe way to study pathogenic microorganisms at the nanoscale with atomic force microscopy can lead to crucial insights into the diseases they cause.


  • Open Access

    A hermetically closed sample chamber enables time-lapse nano-characterization of pathogenic microorganisms in-vitro

    by Esther Braun, Santiago H. Andany, Mustafa Kangül, Navid S. Asmari, John D. McKinney, Georg E. Fantner

    Pathogenic microorganisms, such as pathogenic mycobacteria, pose a global health burden. Studying these organisms is crucial for gaining detailed knowledge about the pathogens and the diseases they cause. To handle pathogenic organisms, specific biosafety measures appropriate to the virulence of the organism must be fulfilled, most importantly ensuring that all manipulations of pathogenic material are performed within a confined environment. Atomic force microscopy (AFM) is a powerful technique to study biological samples at nanometer-scale resolution, yielding also mechanical properties, all while maintaining physiological conditions. However, standard AFM sample holders do not meet stringent biosafety requirements since they do not constitute a confined system. AFM imaging relies on direct contact between the cantilever and the sample and is sensitive to mechanical interference, rendering conventional containment systems for handling infectious substances inapplicable. Here, we introduce a hermetically sealed AFM sample chamber that meets biosafety demands while satisfying the mechanical and optical constraints of correlated optical microscopy and AFM. We imaged various pathogenic mycobacteria to demonstrate the chamber’s versatility and effectiveness in containing biohazardous materials. This sample chamber enables high-resolution, time-lapse correlated imaging and biomechanical characterization of pathogenic microorganisms in-vitro . It broadens the scope of research with pathogenic microorganisms under safe and controlled conditions.

  • JoVE Video Dataset

    by Veronika Cencen, Bahareh Ghadiani, Santiago H. Andany, Mustafa Kangül, Cem Tekin, Marcos Penedo, Maartje Bastings, Georg E. Fantner

    High-speed atomic force microscopy (HS-AFM) is a popular molecular imaging technique for visualizing single-molecule biological processes in real-time due to its ability to image under physiological conditions in liquid environments. The photothermal off-resonance tapping (PORT) mode uses a drive laser to oscillate the cantilever in a controlled manner. This direct cantilever actuation is effective in the MHz range. Combined with operating the feedback loop on the time domain force curve rather than the resonant amplitude, PORT enables high-speed imaging at up to ten frames per second with direct control over tip-sample forces. PORT has been shown to enable imaging of delicate assembly dynamics and precise monitoring of patterns formed by biomolecules. Thus far, the technique has been used for a variety of dynamic in vitro studies, including the DNA 3-point-star motif assembly patterns shown in this work. Through a series of experiments, this protocol systematically identifies the optimal imaging parameter settings and ultimate limits of the HS-PORT AFM imaging system and how they affect biomolecular assembly processes. Additionally, it investigates potential undesired thermal effects induced by the drive laser on the sample and surrounding liquid, particularly when the scanning is limited to small areas. These findings provide valuable insights that will drive the advancement of PORT mode's application in studying complex biological systems.

  • Open Access

    Enhanced feedback performance in off-resonance AFM modes through pulse train sampling

    by Mustafa Kangül, Navid Asmari, Santiago H. Andany, Marcos Penedo, Georg E Fantner

    Dynamic atomic force microscopy (AFM) modes that operate at frequencies far away from the resonance frequency of the cantilever (off-resonance tapping (ORT) modes) can provide high-resolution imaging of a wide range of sample types, including biological samples, soft polymers, and hard materials. These modes offer precise and stable control of vertical force, as well as reduced lateral force. Simultaneously, they enable mechanical property mapping of the sample. However, ORT modes have an intrinsic drawback: a low scan speed due to the limited ORT rate, generally in the low-kilohertz range. Here, we analyze how the conventional ORT control method limits the topography tracking quality and hence the imaging speed. The closed-loop controller in conventional ORT restricts the sampling rate to the ORT rate and introduces a large closed-loop delay. We present an alternative ORT control method in which the closed-loop controller samples and tracks the vertical force changes during a defined time window of the tip–sample interaction. Through this, we use multiple samples in the proximity of the maximum force for the feedback loop, rather than only one sample at the maximum force instant. This method leads to improved topography tracking at a given ORT rate and therefore enables higher scan rates while refining the mechanical property mapping.


  • Open Access

    A high-bandwidth voltage amplifier for driving piezoelectric actuators in high-speed atomic force microscopy

    by Santiago H. Andany, Adrian P. Nievergelt, Mustafa Kangül, Dominik Ziegler, Georg E. Fantner

    High-speed atomic force microscopy (HS-AFM) is a technique capable of revealing the dynamics of biomolecules and living organisms at the nanoscale with a remarkable temporal resolution. The phase delay in the feedback loop dictates the achievable speed of HS-AFM instruments that rely on fast nanopositioners operated predominantly in conjunction with piezoelectric actuators (PEAs). The high capacitance and high operating voltage of PEAs make them difficult to drive. The limited bandwidth of associated high-voltage piezo-amplifiers is one of the bottlenecks to higher scan speeds. In this study, we report a high-voltage, wideband voltage amplifier comprised of a separate amplification and novel voltage-follower power stage, requiring no global feedback. The reported amplifier can deliver a current over ±2 amps, offers a small-signal bandwidth of 1 MHz, and exhibits an exceptionally low phase lag, making it particularly well suited for the needs of next-generation HS-AFMs. We demonstrate its capabilities by reporting its achievable bandwidth under various PEA loads and showcasing its merit for HS-AFM by imaging tubulin protofilament dynamics at sub-second frame rates.


  • Open Access

    Surface-catalyzed SAS-6 self-assembly directs centriole formation through kinetic and structural mechanisms

    by Niccolò Banterle, Adrian Pascal Nievergelt, Svenja de Buhr, Georgios N. Hatzopoulos, Charlène Brillard, Santiago Andany, Tania Hübscher, Frieda Sorgenfrei, Ulrich Sebastian Schwarz, Frauke Gräter, et al.

    Discovering the physical principles directing organelle assembly is a fundamental pursuit in biology. Centrioles are evolutionarily conserved organelles with a 9-fold rotational symmetry of chiral microtubules imparted onto the cilia they template 1 . Centriole assemble from likewise symmetrical ring polymers of SAS-6 proteins, orthogonal to a toroidal surface surrounding the resident centriole 2–4 . How surface properties ensure ring assembly with proper symmetry and orthogonal arrangement is not known. Here, we deployed photothermally-actuated off-resonance tapping high-speed atomic force microscopy (PORT-HS-AFM) to decipher physical principles of surface-guided SAS-6 self-assembly. Using machine learning to quantify the polymerization reaction and developing a coagulation-fragmentation model, we discovered that the surface shifts the reaction equilibrium by ∼10 4 compared to the solution situation, explaining orthogonal organelle emergence. Moreover, molecular dynamics and PORT-HS-AFM revealed that the surface converts helical SAS-6 polymers into 9-fold ring polymers with residual asymmetry, which may impart chiral features to centrioles and cilia. Overall, we discovered two fundamental physical principles directing robust centriole organelle assembly.


  • Open Access

    Integration of sharp silicon nitride tips into high-speed SU8 cantilevers in a batch fabrication process

    by Nahid Hosseini, Matthias Neuenschwander, Oliver Peric, Santiago H. Andany, Jonathan D. Adams, Georg E Fantner

    Integration of sharp silicon nitride tips into high-speed SU8 cantilevers in a batch fabrication process