Byung Il Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Byung Il Park has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Cheolung Cheong
School of Mechanical Engineering, Pusan National University, Busan 46241, Republic of Korea
2 shared publications - Jong Wook Kim
LG Electronics, Changwon 2nd Factory, Seonsan-gu, Changwon-si 51554, Republic of Korea
2 shared publications - Seo-Yoon Ryu
School of Mechanical Engineering, Pusan National University 1 , 46241 Busan, Republic of Korea
2 shared publications - Sai Kee Oh
LG Electronics, Changwon 2nd Factory, Seonsan-dong, Changwon-city, Keongsang Namdo 51554, Korea
1 shared publication - Se Min Park
LG Electronics, Changwon 2nd Factory, Seonsan-dong, Changwon-city, Keongsang Namdo 51554, Korea
1 shared publication - Young-Chull Ahn
Department of Architectural Engineering, Pusan National University, Busan, Korea
1 shared publication
Latest Publications
- Open Access
- 17 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (2) , 804
Development of a Performance-Based Design Technique for an Axial-Flow Fan Unit Using Airfoil Cascades Based on the Blade Strip Theory
Axial-flow fans are widely used as cooling fans in the outdoor units of split-type air conditioners. The design of an axial-flow fan blade involves stacking several airfoils that can be differently designed for each spanwise section. However, the complex flow field around the fan blade, including circumferential and axial flows, presents challenges when applying the single airfoil theory. This study proposed a systematic performance-based design method for axial-flow fans using a cascade of airfoils based on the blade strip theory. The theory characterized the complex three-dimensional flow field driven by an axial-flow fan in terms of a two-dimensional cascade of airfoil flows. Computational fluid dynamics based on finite volume methods were used to predict the flow field and aerodynamic sound sources of an existing low-pressure axial-flow fan partially covered by a fan shroud, and the results were validated against experimental measurements. Three radial locations in the spanwise region from the hub to the blade tip that have a significant impact on aerodynamic performance were selected, and the two-dimensional flow field on a cylindrical surface with a constant radius was extracted from the three-dimensional flow field to characterize the performance of an axial fan. Then, the airfoils at the targeted span locations were optimized for a higher flow rate and greater efficiency via two-dimensional simulations using the cascades of the airfoil, and the selected optimized airfoils were applied to existing fan blades. The effectiveness of the proposed performance-based design method for low-pressure axial-flow fans was validated by the results, which showed that the redesigned fan blades with cascades of airfoils performed as predicted, increasing the intended higher flow rate by about 1%, improving power consumption by 8%, and lowering the overall sound pressure level by 1.5 dBA.
- 17 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (2) , 804
Open AccessDevelopment of a Performance-Based Design Technique for an Axial-Flow Fan Unit Using Airfoil Cascades Based on the Blade Strip Theory
Axial-flow fans are widely used as cooling fans in the outdoor units of split-type air conditioners. The design of an axial-flow fan blade involves stacking several airfoils that can be differently designed for each spanwise section. However, the complex flow field around the fan blade, including circumferential and axial flows, presents challenges when applying the single airfoil theory. This study proposed a systematic performance-based design method for axial-flow fans using a cascade of airfoils based on the blade strip theory. The theory characterized the complex three-dimensional flow field driven by an axial-flow fan in terms of a two-dimensional cascade of airfoil flows. Computational fluid dynamics based on finite volume methods were used to predict the flow field and aerodynamic sound sources of an existing low-pressure axial-flow fan partially covered by a fan shroud, and the results were validated against experimental measurements. Three radial locations in the spanwise region from the hub to the blade tip that have a significant impact on aerodynamic performance were selected, and the two-dimensional flow field on a cylindrical surface with a constant radius was extracted from the three-dimensional flow field to characterize the performance of an axial fan. Then, the airfoils at the targeted span locations were optimized for a higher flow rate and greater efficiency via two-dimensional simulations using the cascades of the airfoil, and the selected optimized airfoils were applied to existing fan blades. The effectiveness of the proposed performance-based design method for low-pressure axial-flow fans was validated by the results, which showed that the redesigned fan blades with cascades of airfoils performed as predicted, increasing the intended higher flow rate by about 1%, improving power consumption by 8%, and lowering the overall sound pressure level by 1.5 dBA.
- Open Access
- 29 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (23) , 5207
Optimization of the Orifice Shape of Cooling Fan Units for High Flow Rate and Low-Level Noise in Outdoor Air Conditioning Units
Demand for air conditioners is steadily increasing due to global warming and improved living standards. The noise, as well as the performance of air conditioners, are recognized as one of the crucial factors that determine the air conditioners’ values. The performance and noise of the air conditioner are mostly determined by those of its outdoor unit, which in turn depend on those of the cooling fan unit. Therefore, a cooling fan unit of high-performance and low noise is essential for air-conditioner manufacturers and developers. In this paper, the flow performance and flow noise of the entire outdoor unit with an axial cooling fan in a split-type air-conditioner were investigated. First, a virtual fan tester constructed by using about 18 million grids is developed for highly resolved flow simulation. The unsteady Reynolds-Averaged Navier–Stokes equations are numerically solved by using finite-volume computational fluid dynamics techniques. To verify the validity of the numerical analysis, the predicted P–Q curve of the cooling fan in a full outdoor unit is compared with the measured one. There was an excellent agreement between the two curves. The further detailed analysis identifies the coherent vortex structures between the fan blade tip and fan orifice, which adversely affect the flow performance and causes flow noise. Based on this analysis, the optimization of fan orifice was carried out using the response surface method with three geometric parameters: inlet radius, neck length, and outlet angel of the orifice. The optimum layout for the high flow rate is proposed under the understanding that the increased flow rate can be converted to noise reduction. The additional computation using the proposed optimum orifice shows that the flow rate is increased by 4.6% at the operating point. Finally, the engineering sample was manufactured by using the optimum design, and the measured data confirmed that the flow rate were increased by 2.1%, the noise reduction was made by 2.8 dBA, and the power consumption is reduced by 4.0% at the operating rotational speed.
- 29 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (23) , 5207
Open AccessOptimization of the Orifice Shape of Cooling Fan Units for High Flow Rate and Low-Level Noise in Outdoor Air Conditioning Units
Demand for air conditioners is steadily increasing due to global warming and improved living standards. The noise, as well as the performance of air conditioners, are recognized as one of the crucial factors that determine the air conditioners’ values. The performance and noise of the air conditioner are mostly determined by those of its outdoor unit, which in turn depend on those of the cooling fan unit. Therefore, a cooling fan unit of high-performance and low noise is essential for air-conditioner manufacturers and developers. In this paper, the flow performance and flow noise of the entire outdoor unit with an axial cooling fan in a split-type air-conditioner were investigated. First, a virtual fan tester constructed by using about 18 million grids is developed for highly resolved flow simulation. The unsteady Reynolds-Averaged Navier–Stokes equations are numerically solved by using finite-volume computational fluid dynamics techniques. To verify the validity of the numerical analysis, the predicted P–Q curve of the cooling fan in a full outdoor unit is compared with the measured one. There was an excellent agreement between the two curves. The further detailed analysis identifies the coherent vortex structures between the fan blade tip and fan orifice, which adversely affect the flow performance and causes flow noise. Based on this analysis, the optimization of fan orifice was carried out using the response surface method with three geometric parameters: inlet radius, neck length, and outlet angel of the orifice. The optimum layout for the high flow rate is proposed under the understanding that the increased flow rate can be converted to noise reduction. The additional computation using the proposed optimum orifice shows that the flow rate is increased by 4.6% at the operating point. Finally, the engineering sample was manufactured by using the optimum design, and the measured data confirmed that the flow rate were increased by 2.1%, the noise reduction was made by 2.8 dBA, and the power consumption is reduced by 4.0% at the operating rotational speed.