BABeatriz Alonso

Beatriz Alonso

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Beatriz Alonso has a total of 121 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    “Wire‐Print” as a New Sample Preparation Procedure for Accurate Morphological and Chemical Analysis of Particles and Flakes With Microscopy and Spectroscopy Methods

    by Paul Mrkwitschka, Mario Sahre, Elena Corrao, Francesco Pellegrino, Amaia Zurutuza, Beatriz Alonso, Franziska Emmerling, Vasile‐Dan Hodoroaba

    The newly developed “wire‐print” method is a fast, repeatable and flexible sample preparation procedure aimed at depositing isolated particles or flakes on a substrate for morphological/dimensional analysis, but also for the analysis of the chemical composition. The method was successfully tested on graphene‐related 2D materials (GR2M) and a set of representative reference particles with sizes in nano‐ and micrometer range. Due to their complex morphology and chemistry, the accurate characterization of GR2M is challenging and no standard sample preparation procedure is available. In terms of deposited volume (down to well below 1 nL) and area (down to tens of µm), wire‐print is similar to the piezoelectrical‐driven inkjet printing, but without applying shearing forces to the suspension. It allows for high‐throughput and repeatable deposition of most particulate materials from liquid dispersion as isolated objects onto a substrate. For chemical analysis with Energy‐Dispersive X‐Ray Spectroscopy (EDS) or X‐Ray Photoelectron Spectroscopy (XPS), wire‐printing of µm‐thick and compact spots is also demonstrated. The very short drying times of tiny volumes of suspension imposed by wire‐printing lead to the significant reduction or even disappearance of the typical coffee‐ring effect and thus, to a more homogeneous deposition.

  • Open Access

    Reusable graphene oxide-based composite membranes for highly efficient and fast removal of pesticides from real water matrixes

    by Elena Pagalday, Hugo Salazar, Carmen R. Tubio, Beatriz Alonso, Tobias Kuhnt, Ahmed Elmaraki, Leire Ruiz-Rubio, Senentxu Lanceros-Mendez


  • Open Access

    Role of Chemical Reduction and Formulation of Graphene Oxide on Its Cytotoxicity towards Human Epithelial Bronchial Cells

    by Marco Pelin, Clara Passerino, Adriana Rodríguez-Garraus, Michela Carlin, Silvio Sosa, Satu Suhonen, Gerard Vales, Beatriz Alonso, Amaia Zurutuza, Julia Catalán, et al.

    Graphene-based materials may pose a potential risk for human health due to occupational exposure, mainly by inhalation. This study was carried out on bronchial epithelial 16HBE14o− cells to evaluate the role of chemical reduction and formulation of graphene oxide (GO) on its cytotoxic potential. To this end, the effects of GO were compared to its chemically reduced form (rGO) and its stable water dispersion (wdGO), by means of cell viability reduction, reactive oxygen species (ROS) generation, pro-inflammatory mediators release and genotoxicity. These materials induced a concentration-dependent cell viability reduction with the following potency rank: rGO > GO >> wdGO. After 24 h exposure, rGO reduced cell viability with an EC50 of 4.8 μg/mL (eight-fold lower than that of GO) and was the most potent material in inducing ROS generation, in contrast to wdGO. Cytokines release and genotoxicity (DNA damage and micronucleus induction) appeared low for all the materials, with wdGO showing the lowest effect, especially for the former. These results suggest a key role for GO reduction in increasing GO cytotoxic potential, probably due to material structure alterations resulting from the reduction process. In contrast, GO formulated in a stable dispersion seems to be the lowest cytotoxic material, presumably due to its lower cellular internalization and damaging capacity.


  • Cement Based Materials with PCM and Reduced Graphene Oxide for Thermal Insulation for Buildings

    by Edurne Erkizia, Christina Strunz, Jean-Luc Dauvergne, Guido Goracci, Ignacio Peralta, Ángel Serrano, Amaya Ortega, Beatriz Alonso, Francesca Zanoni, Michael Düngfelder, et al.


  • Open Access

    Effect of Varying Amine Functionalities on CO2 Capture of Carboxylated Graphene Oxide-Based Cryogels

    by Alina I. Pruna, Arturo Barjola, Alfonso C. Cárcel, Beatriz Alonso, Enrique Giménez

    Graphene cryogels synthesis is reported by amine modification of carboxylated graphene oxide via aqueous carbodiimide chemistry. The effect of the amine type on the formation of the cryogels and their properties is presented. In this respect, ethylenediamine (EDA), diethylenetriamine (DETA), triethylenetetramine (TETA), were selected. The obtained cryogels were characterized by Fourier Transformed Infrared spectroscopy, thermogravimetric analysis, X-ray spectroscopy, and Scanning electron microscopy. The CO2 adsorption performance was evaluated as a function of amine modification. The results showed the best CO2 adsorption performance was exhibited by ethylenediamine modified aerogel, reaching 2 mmol g−1 at 1 bar and 298 K. While the total N content of the cryogels increased with increasing amine groups, the nitrogen configuration and contributions were determined to have more important influence on the adsorption properties. It is also revealed that the residual oxygen functionalities in the obtained cryogels represent another paramount factor to take into account for improving the CO2 capture properties of amine-modified graphene oxide (GO)-based cryogels.


  • Open Access

    Study of Microwave Heating Effect in the Behaviour of Graphene as Second Phase in Ceramic Composites

    by Rut Benavente, María Dolores Salvador, Alba Centeno, Beatriz Alonso, Amaia Zurutuza, Amparo Borrell

    The choice of the right material is essential in microwave processing. The carbon materials are good microwave absorbers, which allows them to be transformed by microwave heating into new carbon materials with adapted properties, capable of heating other materials indirectly. In this paper, the microwave heating of graphene as reinforcement of the lithium aluminosilicate (LAS) ceramics has been explored. LAS ceramics have a near-zero coefficient of thermal expansion and exhibit an effective and efficient heating by microwave. Nevertheless, we have found that the graphene did not show any significant response to the microwave radiation and, hence, the interaction as mechanical reinforcement with the LAS material is harmful. The possible benefits of graphene materials to microwave technology are widely known; however, the mechanism involved in the interaction of microwave radiation with ceramic-graphene composites with high dielectric loss factors has not been addressed earlier.


  • Open Access

    Skin irritation potential of graphene-based materials using a non-animal test

    by Laura Fusco, Marina Garrido, Cristina Martín, Silvio Sosa, Cristina Ponti, Alba Centeno, Beatriz Alonso, Amaia Zurutuza, Ester Vázquez, Aurelia Tubaro, et al.

    Graphene related materials, if prepared with non-irritant exfoliation agents, do not induce skin irritation on a 3D model of human epidermis, following the OECD guideline 439.


  • Coating Graphene Oxide with Lipid Bilayers Greatly Decreases Its Hemolytic Properties

    by Bingen G. Monasterio, Beatriz Alonso, Jesús Sot, Aritz B. García-Arribas, David Gil-Cartón, Mikel Valle, Amaia Zurutuza, Félix M. Goñi

    Toxicity evaluation for the proper use of graphene oxide (GO) in biomedical applications involving intravenous injections is crucial, but the GO circulation time and blood interactions are largely unknown. It is thought that GO may cause physical disruption (hemolysis) of red blood cells. The aim of this work is to characterize the interaction of GO with model and cell membranes and use this knowledge to improve GO hemocompatibility. We have found that GO interacts with both neutral and negatively charged lipid membranes; binding is decreased beyond a certain concentration of negatively charged lipids and favored in high-salt buffers. After this binding occurs, some of the vesicles remain intact, while others are disrupted and spread over the GO surface. Neutral membrane vesicles tend to break down and extend over the GO, while vesicles with negatively charged membranes are mainly bound to the GO without disruption. GO also interacts with red blood cells and causes hemolysis; hemolysis is decreased when GO is previously coated with lipid membranes, particularly with pure phosphatidylcholine vesicles.


  • Open Access

    Differences in inflammation and acute phase response but similar genotoxicity in mice following pulmonary exposure to graphene oxide and reduced graphene oxide

    by Stefan Bengtson, Kristina B Knudsen, Zdenka O Kyjovska, Trine Berthing, Vidar Skaug, Marcus Levin, Ismo K Koponen, Abhay Shivayogimath, Timothy J Booth, Beatriz Alonso, et al.

    We investigated toxicity of 2–3 layered >1 μm sized graphene oxide (GO) and reduced graphene oxide (rGO) in mice following single intratracheal exposure with respect to pulmonary inflammation, acute phase response (biomarker for risk of cardiovascular disease) and genotoxicity. In addition, we assessed exposure levels of particulate matter emitted during production of graphene in a clean room and in a normal industrial environment using chemical vapour deposition. Toxicity was evaluated at day 1, 3, 28 and 90 days (18, 54 and 162 μg/mouse), except for GO exposed mice at day 28 and 90 where only the lowest dose was evaluated. GO induced a strong acute inflammatory response together with a pulmonary (Serum-Amyloid A, Saa3) and hepatic (Saa1) acute phase response. rGO induced less acute, but a constant and prolonged inflammation up to day 90. Lung histopathology showed particle agglomerates at day 90 without signs of fibrosis. In addition, DNA damage in BAL cells was observed across time points and doses for both GO and rGO. In conclusion, pulmonary exposure to GO and rGO induced inflammation, acute phase response and genotoxicity but no fibrosis.


  • Capillary pressure in graphene oxide nanoporous membranes for enhanced heat transport in Loop Heat Pipes for aeronautics

    by Cosimo Buffone, Jerome Coulloux, Beatriz Alonso, Mark Schlechtendahl, Vincenzo Palermo, Amaia Zurutuza, Thomas Albertin, Simon Martin, Marco Molina, Sergey Chikov, et al.