Latest Publications
- Open Access
- 1 September 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 16  (3) , 2130-2142
Inverter transient response improvement using grey wolf optimizer for type-2 fuzzy control in HVDC transmission link
High voltage direct current (HVDC) on transmission-link becomes a new prominent technology in recent years. The HVDC is applied to transmit amount of electrical energy from power plant to consumers. This method makes reactive power losses on transmission devices decrease significantly and stability level of generator increases. However, inverter HVDC transmission system can produce slow and high inverter transient current (ITC) response at high value of the up-ramp rate. This ITC phenomenon can be serious problem at starting time. So grey wolf algorithm is proposed to optimize input-output parameters of interval type-2 fuzzy control (IT2FC) in inverter-side HVDC. The proposed control performance’s is assessed by integral time squared error (ITSE) and peak overshoot (Mp) approaches. Simulation results show that small ITSE and low Mp of transient response are given by the IT2FC. The IT2FC is successful applied on inverter HVDC with better results compared to conventional PI control scheme.
- 1 September 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 16  (3) , 2130-2142
Open AccessInverter transient response improvement using grey wolf optimizer for type-2 fuzzy control in HVDC transmission link
High voltage direct current (HVDC) on transmission-link becomes a new prominent technology in recent years. The HVDC is applied to transmit amount of electrical energy from power plant to consumers. This method makes reactive power losses on transmission devices decrease significantly and stability level of generator increases. However, inverter HVDC transmission system can produce slow and high inverter transient current (ITC) response at high value of the up-ramp rate. This ITC phenomenon can be serious problem at starting time. So grey wolf algorithm is proposed to optimize input-output parameters of interval type-2 fuzzy control (IT2FC) in inverter-side HVDC. The proposed control performance’s is assessed by integral time squared error (ITSE) and peak overshoot (Mp) approaches. Simulation results show that small ITSE and low Mp of transient response are given by the IT2FC. The IT2FC is successful applied on inverter HVDC with better results compared to conventional PI control scheme.
- Open Access
- 27 August 2025
- Published by Universitas Muhammadiyah Jember in Jurnal Teknik Elektro dan Komputasi (ELKOM)
- Vol. 7  (2) , 163-173
Prototipe Alat Ukur Untuk Analisis Stabilitas Transien Arus DC pada PLTS On-Grid
Prototipe Alat Ukur Untuk Analisis Stabilitas Transien Arus DC pada PLTS On-Grid
- 27 August 2025
- Published by Universitas Muhammadiyah Jember in Jurnal Teknik Elektro dan Komputasi (ELKOM)
- Vol. 7  (2) , 163-173
Open AccessPrototipe Alat Ukur Untuk Analisis Stabilitas Transien Arus DC pada PLTS On-Grid
Prototipe Alat Ukur Untuk Analisis Stabilitas Transien Arus DC pada PLTS On-Grid
- Open Access
- 11 June 2025
- Published by Universitas 17 Agustus 1945 Surabaya in El Sains: Jurnal Elektro
- Vol. 7  (1) , 29-34
Pemodelan Maximum Power Point Tracking pada Inverter Hybrid Pada Sistem Pengisian Baterai VRLA 12 V 100 Ah Dari Sumber PV
The hybrid inverter is capable of managing various energy sources such as PV and the grid. One of the modes of the hybrid inverter is the battery charging mode using the Maximum Power Point Tracking (MPPT) technique. This technique aims to maximize the power efficiency generated by PV by dynamically adjusting to the maximum power point. This study aims to develop a battery charging system model for a 12 V 100 Ah Valve Regulated Lead Acid (VRLA) battery using Simulink MATLAB. The charging system consists of a DC/DC converter within the hybrid inverter, controlled by the MPPT technique for efficient charging. The VRLA battery charging process involves three stages: constant current, constant voltage, and float charging. The MPPT technique is applied during the constant current stage to utilize the maximum output power from the PV. The charging system model is compared with the battery charging mode of commercially available off-grid hybrid inverters for validation. The results show that the MPPT-based hybrid inverter charging model was successfully developed, and the application of the MPPT technique during the constant current stage improved the PV power tracking efficiency. Validation of the MPPT performance in the off-grid hybrid inverter’s battery charging mode showed consistency with the simulation results. This study can be used for simulating the latest MPPT methods and intelligent techniques for VRLA battery charging.
- 11 June 2025
- Published by Universitas 17 Agustus 1945 Surabaya in El Sains: Jurnal Elektro
- Vol. 7  (1) , 29-34
Open AccessPemodelan Maximum Power Point Tracking pada Inverter Hybrid Pada Sistem Pengisian Baterai VRLA 12 V 100 Ah Dari Sumber PV
The hybrid inverter is capable of managing various energy sources such as PV and the grid. One of the modes of the hybrid inverter is the battery charging mode using the Maximum Power Point Tracking (MPPT) technique. This technique aims to maximize the power efficiency generated by PV by dynamically adjusting to the maximum power point. This study aims to develop a battery charging system model for a 12 V 100 Ah Valve Regulated Lead Acid (VRLA) battery using Simulink MATLAB. The charging system consists of a DC/DC converter within the hybrid inverter, controlled by the MPPT technique for efficient charging. The VRLA battery charging process involves three stages: constant current, constant voltage, and float charging. The MPPT technique is applied during the constant current stage to utilize the maximum output power from the PV. The charging system model is compared with the battery charging mode of commercially available off-grid hybrid inverters for validation. The results show that the MPPT-based hybrid inverter charging model was successfully developed, and the application of the MPPT technique during the constant current stage improved the PV power tracking efficiency. Validation of the MPPT performance in the off-grid hybrid inverter’s battery charging mode showed consistency with the simulation results. This study can be used for simulating the latest MPPT methods and intelligent techniques for VRLA battery charging.
- Open Access
- 1 March 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Reconfigurable and Embedded Systems (IJRES)
- Vol. 14  (1) , 126-135
Design of flood warning prototype using ESP32 module-based ultrasonic sensors
Natural disasters such as floods can cause many losses to humans, such as material losses, trauma for the victims, and loss of life. Floods that occur can be caused by various factors such as human activity itself which results in changes in natural spatial planning, so the arrival of floods is also difficult to detect with certainty. Based on this, it is necessary to develop a technological innovation that helps provide a warning of the arrival of a natural disaster. The ESP32 microcontroller is one of the technologies that can be used to create an early warning system for the arrival of floods. The design and manufacture of this technology certainly involves modeling, algorithm planning, assembly of the components of the tools used, including wiring and mechanics as needed. This tool uses an internet of things (IoT) system with the help of an ESP32 microcontroller that supports integration via Wi-Fi and Bluetooth so that it can be connected to a smartphone device as a notification receiver in real time and accurately by notifying the water level which will be an indicator of potential flooding, so that people are more alert in the face of flooding to prevent and minimize the losses that will be experienced.
- 1 March 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Reconfigurable and Embedded Systems (IJRES)
- Vol. 14  (1) , 126-135
Open AccessDesign of flood warning prototype using ESP32 module-based ultrasonic sensors
Natural disasters such as floods can cause many losses to humans, such as material losses, trauma for the victims, and loss of life. Floods that occur can be caused by various factors such as human activity itself which results in changes in natural spatial planning, so the arrival of floods is also difficult to detect with certainty. Based on this, it is necessary to develop a technological innovation that helps provide a warning of the arrival of a natural disaster. The ESP32 microcontroller is one of the technologies that can be used to create an early warning system for the arrival of floods. The design and manufacture of this technology certainly involves modeling, algorithm planning, assembly of the components of the tools used, including wiring and mechanics as needed. This tool uses an internet of things (IoT) system with the help of an ESP32 microcontroller that supports integration via Wi-Fi and Bluetooth so that it can be connected to a smartphone device as a notification receiver in real time and accurately by notifying the water level which will be an indicator of potential flooding, so that people are more alert in the face of flooding to prevent and minimize the losses that will be experienced.
- Open Access
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 13  (4) , 1014-1020
Assessing transformer health through analysis of dissolved gases in cooling oil
Gases can form within the insulation system for various reasons while a transformer is in operation. If these gases are not promptly and properly managed, they can negatively impact the transformer's performance. Using the dissolved gas analysis (DGA) method to identify and assess the type and quantity of dissolved gases in transformer oil can uncover potential issues within the transformer. This information is crucial for guiding preventive maintenance and necessary repairs. Dissolved gas analysis testing was conducted by extracting transformer oil samples to identify signs of disturbances in the transformer based on the dissolved gas content. This research was conducted at the Paiton plant operations and maintenance services division. The condition of transformers was assessed by analyzing dissolved gases using the Rogers ratio method. Results indicate that the transformer at Paiton 9 is in good condition but overheating has occurred and requires treatment. Conversely, the transformers at Paiton 1 and 2 are in poor condition, showing signs of electrical faults and excessive heat. Despite several attempts to add inhibitors and conduct frequent testing, the transformers remained in poor condition, necessitating their replacement or repair.
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 13  (4) , 1014-1020
Open AccessAssessing transformer health through analysis of dissolved gases in cooling oil
Gases can form within the insulation system for various reasons while a transformer is in operation. If these gases are not promptly and properly managed, they can negatively impact the transformer's performance. Using the dissolved gas analysis (DGA) method to identify and assess the type and quantity of dissolved gases in transformer oil can uncover potential issues within the transformer. This information is crucial for guiding preventive maintenance and necessary repairs. Dissolved gas analysis testing was conducted by extracting transformer oil samples to identify signs of disturbances in the transformer based on the dissolved gas content. This research was conducted at the Paiton plant operations and maintenance services division. The condition of transformers was assessed by analyzing dissolved gases using the Rogers ratio method. Results indicate that the transformer at Paiton 9 is in good condition but overheating has occurred and requires treatment. Conversely, the transformers at Paiton 1 and 2 are in poor condition, showing signs of electrical faults and excessive heat. Despite several attempts to add inhibitors and conduct frequent testing, the transformers remained in poor condition, necessitating their replacement or repair.
- Open Access
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14  (6) , 7158-7168
Control and monitoring of 1 phase generator automatic voltage regulator internet of things
This research focuses on the importance of maintaining generator output voltage stabilization using automatic voltage regulator (AVR), especially in dealing with load impacts and environmental changes. Through the implementation of internet of things (IoT), this system can be controlled and monitored remotely, enabling real-time monitoring without physical presence at the generator location. The main objective of this research is to increase energy efficiency by optimizing generator operation. System development methods include design, prototyping and testing stages. Test results show that the automatic voltage regulator is effective in maintaining a stable output voltage of around 220 V, even though the current varies according to the existing load. The power produced ranges from 23 to 670 W, with a power factor between 0.7 and 1. Despite a slight voltage drop to 217 V, the power factor increases to 0.93. The system uses NodeMCU to send data to Blynk and Google Spreadsheets servers, as well as servo motors and PZEM-004T sensors for control and monitoring. Overall, this research shows that the internet of things-based automatic voltage regulator system is effective in maintaining stability and increasing generator operational efficiency, with the ability to manage voltage, current, power, and power factor efficiently.
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14  (6) , 7158-7168
Open AccessControl and monitoring of 1 phase generator automatic voltage regulator internet of things
This research focuses on the importance of maintaining generator output voltage stabilization using automatic voltage regulator (AVR), especially in dealing with load impacts and environmental changes. Through the implementation of internet of things (IoT), this system can be controlled and monitored remotely, enabling real-time monitoring without physical presence at the generator location. The main objective of this research is to increase energy efficiency by optimizing generator operation. System development methods include design, prototyping and testing stages. Test results show that the automatic voltage regulator is effective in maintaining a stable output voltage of around 220 V, even though the current varies according to the existing load. The power produced ranges from 23 to 670 W, with a power factor between 0.7 and 1. Despite a slight voltage drop to 217 V, the power factor increases to 0.93. The system uses NodeMCU to send data to Blynk and Google Spreadsheets servers, as well as servo motors and PZEM-004T sensors for control and monitoring. Overall, this research shows that the internet of things-based automatic voltage regulator system is effective in maintaining stability and increasing generator operational efficiency, with the ability to manage voltage, current, power, and power factor efficiently.
- Open Access
- 9 October 2024
- Published by LPPM Universitas Malikussaleh in Journal of Renewable Energy, Electrical, and Computer Engineering
- Vol. 4  (2) , 131-141
Performance Analysis of On-Grid Rooftop Solar Power Plant with 600 Wp Capacity Based on Data Logger
One of the renewable energy power plants whose construction is very massive is the solar power plant (PLTS) because it can be built anywhere in Indonesia. The type of PLTS with cheap investment is the on-grid system. This study aims to analyze the performance of the 600 Wp on-grid PLTS based on data loggers. Data logger is a data recording system designed using an Arduino Nano microcontroller equipped with sensors such as a solar radiation sensor (PYR20), temperature and humidity sensor (DHT22), PV module temperature sensor (DS18B20), DC voltage sensor, DC current sensor (ACS712), real time clock (DS3231), AC digital wattmeter module (PZEM-004T 10 A) and Micro SD Card Mini to store measurement data. The data logger is set to store measurement data every 5 minutes. The results of sensor measurements after calibration have an average measurement error of 5.20%, 0.56%, and 0.68% for the PYR20 irradiance sensor, 50 V range DC voltage sensor, and DC current sensor (ACS712). Based on the results of data logger recording, the 600 Wp on-grid PLTS system has a PV module efficiency in the range of 2.45 - 19.2% with an average of 8.60%, and the inverter (smart microgrid inverter) has an average efficiency of 89.40%.
- 9 October 2024
- Published by LPPM Universitas Malikussaleh in Journal of Renewable Energy, Electrical, and Computer Engineering
- Vol. 4  (2) , 131-141
Open AccessPerformance Analysis of On-Grid Rooftop Solar Power Plant with 600 Wp Capacity Based on Data Logger
One of the renewable energy power plants whose construction is very massive is the solar power plant (PLTS) because it can be built anywhere in Indonesia. The type of PLTS with cheap investment is the on-grid system. This study aims to analyze the performance of the 600 Wp on-grid PLTS based on data loggers. Data logger is a data recording system designed using an Arduino Nano microcontroller equipped with sensors such as a solar radiation sensor (PYR20), temperature and humidity sensor (DHT22), PV module temperature sensor (DS18B20), DC voltage sensor, DC current sensor (ACS712), real time clock (DS3231), AC digital wattmeter module (PZEM-004T 10 A) and Micro SD Card Mini to store measurement data. The data logger is set to store measurement data every 5 minutes. The results of sensor measurements after calibration have an average measurement error of 5.20%, 0.56%, and 0.68% for the PYR20 irradiance sensor, 50 V range DC voltage sensor, and DC current sensor (ACS712). Based on the results of data logger recording, the 600 Wp on-grid PLTS system has a PV module efficiency in the range of 2.45 - 19.2% with an average of 8.60%, and the inverter (smart microgrid inverter) has an average efficiency of 89.40%.
- Open Access
- 3 August 2024
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat Universitas Lampung in Jurnal Informatika dan Teknik Elektro Terapan
- Vol. 12  (3)
PENGUJIAN TEGANGAN TEMBUS MINYAK TRAFO PADA BAY TRAFO 1 DI GI 150 kV TANJUNG
The transformer is the main component in a substation (GI). Transformer failure causes continuity of electricity service to be disrupted. One preventive maintenance to avoid transformer failure is testing the breakdown voltage of the transformer oil. Breakdown voltage testing is carried out routinely once a year. This research tested the transformer oil breakdown voltage in transformer bay 1 at the GI of Tanjung 150 kV. Testing was carried out using procedures and methods that refer to the 1995 IEC 60156-02 standard with mushroom electrodes and an electrode distance of 2.5 mm. Oil samples from the main tank and from the Tap Changer. The average breakdown voltage test results were 59.4 and 36 kV/2.5 mm for oil in the main tank and in the Tap Changer. The test results according to the breakdown voltage criteria for transformer oil referring to the 2013 IEC 60422 standard are good or still suitable for use.
- 3 August 2024
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat Universitas Lampung in Jurnal Informatika dan Teknik Elektro Terapan
- Vol. 12  (3)
Open AccessPENGUJIAN TEGANGAN TEMBUS MINYAK TRAFO PADA BAY TRAFO 1 DI GI 150 kV TANJUNG
The transformer is the main component in a substation (GI). Transformer failure causes continuity of electricity service to be disrupted. One preventive maintenance to avoid transformer failure is testing the breakdown voltage of the transformer oil. Breakdown voltage testing is carried out routinely once a year. This research tested the transformer oil breakdown voltage in transformer bay 1 at the GI of Tanjung 150 kV. Testing was carried out using procedures and methods that refer to the 1995 IEC 60156-02 standard with mushroom electrodes and an electrode distance of 2.5 mm. Oil samples from the main tank and from the Tap Changer. The average breakdown voltage test results were 59.4 and 36 kV/2.5 mm for oil in the main tank and in the Tap Changer. The test results according to the breakdown voltage criteria for transformer oil referring to the 2013 IEC 60422 standard are good or still suitable for use.
- Open Access
- 2 May 2024
- Published by IntechOpen
Application of adaptive neuro-fuzzy inference system control in power systems
An adaptive neuro-fuzzy inference system (ANFIS) is developed by combining neural-networks and fuzzy system. The ANFIS model uses the advantages possessed by the properties of neural networks and its decision making is based on fuzzy inference. The ANFIS parameters are obtained and updated by training processes. The ANFIS consists of two inputs (by Gaussian or other membership function) and an output (with constant or linear membership function). The ANFIS control is implemented by building a power system stabilizer (PSS) in power systems. The PSS function is to produce an additional stabilizing signal on the reactive mode of the generator. Training data are obtained from the systems that controlled by a conventional PSS with various conditions. The training process is carried out repeatedly until the appropriate ANFIS parameters are found. Next, the PSS based on ANFIS is applied to replace the conventional PSS on a single machine and hybrid power plants. Peak overshoot and settling time of the power systems are smaller and shorter. The ANFIS PSS makes the power system stability improve significantly in small-signal studies.
- 2 May 2024
- Published by IntechOpen
Open AccessApplication of adaptive neuro-fuzzy inference system control in power systems
An adaptive neuro-fuzzy inference system (ANFIS) is developed by combining neural-networks and fuzzy system. The ANFIS model uses the advantages possessed by the properties of neural networks and its decision making is based on fuzzy inference. The ANFIS parameters are obtained and updated by training processes. The ANFIS consists of two inputs (by Gaussian or other membership function) and an output (with constant or linear membership function). The ANFIS control is implemented by building a power system stabilizer (PSS) in power systems. The PSS function is to produce an additional stabilizing signal on the reactive mode of the generator. Training data are obtained from the systems that controlled by a conventional PSS with various conditions. The training process is carried out repeatedly until the appropriate ANFIS parameters are found. Next, the PSS based on ANFIS is applied to replace the conventional PSS on a single machine and hybrid power plants. Peak overshoot and settling time of the power systems are smaller and shorter. The ANFIS PSS makes the power system stability improve significantly in small-signal studies.
- Open Access
- 20 April 2024
- Published by Akademi Komunitas Negeri Aceh Barat in VOCATECH: Vocational Education and Technology Journal
- Vol. 5  (2) , 136-146
Simulasi dan Analisis Unjuk Kerja Plts Atap Off-Grid Terinstal Supercapacitor
The reliability of off-grid solar power systems (PLTS) is highly dependent on battery performance. However, the battery shows limited response in supplying the load due to unstable voltage fluctuations, which causes the battery to heat up quickly. So there is a need for additional components in the system such as supercapacitors. Supercapacitors are energy storage devices with high power and energy density, short charging duration, long service life, and low risk of heat. This research aims to determine the effect of supercapacitors on the performance of off-grid PLTS systems. The research uses data from the specifications of the off-grid rooftop PLTS system at SMKN 1 Lingsar. Temperature and irradiation data are obtained from the data logger installed in the system. The research is a simulation in Simulink MATLAB. Several supercapacitor capacities were selected to determine changes in system performance. The simulation results show that the supercapacitor capacity has a significant effect on the current and voltage in the battery. Supercapacitors show the ability to absorb and release large currents in a relatively short time, thereby speeding up the battery charging process. Supercapacitors with a capacity equivalent to battery capacity have the best contribution to system performance. Keywords:Batteries; Off-grid Rooftop PV System; Supercapacitor. AbstrakKeandalan sistem tenaga surya (PLTS) off-grid sangat bergantung pada kinerja baterai. Namun, baterai menunjukkan respons yang terbatas dalam menyuplai beban karena fluktuasi tegangan yang tidak stabil, yang menyebabkan baterai menjadi cepat panas. Sehingga perlu adanya komponen tambahan pada sistem seperti superkapasitor. Superkapasitor adalah perangkat penyimpanan energi dengan daya dan kepadatan energi tinggi, durasi pengisian daya yang singkat, masa pakai yang lama, serta risiko panas yang rendah. Penelitian ini bertujuan mengetahui pengaruh supercapasitor pada kinerja sistem PLTS off-grid. Penelitian menggunakan data dari spesifikasi sistem PLTS atap off-grid di SMKN 1 Lingsar. Data suhu dan iradiasi diperoleh dari data logger yang terpasang pada sistem. Penelitian merupakan simulasi pada Simulink MATLAB. Beberapa kapasitas supercapasitor dipilih untuk mengetahui perubahan kinerja sistem. Hasil simulasi menunjukkan bahwa kapasitas superkapasitor berpengaruh signifikan terhadap arus dan tegangan pada baterai. Superkapasitor menunjukkan kemampuan menyerap dan melepaskan arus besar dalam waktu relatif singkat sehingga mempercepat proses pengisian baterai. Superkapasitor berkapasitas setara kapasitas baterai mempunyai konstribusi terbaik pada kinerja sistem. Kata Kunci: Baterai, Sistem PV Atap Off-grid, Superkapasitor.
- 20 April 2024
- Published by Akademi Komunitas Negeri Aceh Barat in VOCATECH: Vocational Education and Technology Journal
- Vol. 5  (2) , 136-146
Open AccessSimulasi dan Analisis Unjuk Kerja Plts Atap Off-Grid Terinstal Supercapacitor
The reliability of off-grid solar power systems (PLTS) is highly dependent on battery performance. However, the battery shows limited response in supplying the load due to unstable voltage fluctuations, which causes the battery to heat up quickly. So there is a need for additional components in the system such as supercapacitors. Supercapacitors are energy storage devices with high power and energy density, short charging duration, long service life, and low risk of heat. This research aims to determine the effect of supercapacitors on the performance of off-grid PLTS systems. The research uses data from the specifications of the off-grid rooftop PLTS system at SMKN 1 Lingsar. Temperature and irradiation data are obtained from the data logger installed in the system. The research is a simulation in Simulink MATLAB. Several supercapacitor capacities were selected to determine changes in system performance. The simulation results show that the supercapacitor capacity has a significant effect on the current and voltage in the battery. Supercapacitors show the ability to absorb and release large currents in a relatively short time, thereby speeding up the battery charging process. Supercapacitors with a capacity equivalent to battery capacity have the best contribution to system performance. Keywords:Batteries; Off-grid Rooftop PV System; Supercapacitor. AbstrakKeandalan sistem tenaga surya (PLTS) off-grid sangat bergantung pada kinerja baterai. Namun, baterai menunjukkan respons yang terbatas dalam menyuplai beban karena fluktuasi tegangan yang tidak stabil, yang menyebabkan baterai menjadi cepat panas. Sehingga perlu adanya komponen tambahan pada sistem seperti superkapasitor. Superkapasitor adalah perangkat penyimpanan energi dengan daya dan kepadatan energi tinggi, durasi pengisian daya yang singkat, masa pakai yang lama, serta risiko panas yang rendah. Penelitian ini bertujuan mengetahui pengaruh supercapasitor pada kinerja sistem PLTS off-grid. Penelitian menggunakan data dari spesifikasi sistem PLTS atap off-grid di SMKN 1 Lingsar. Data suhu dan iradiasi diperoleh dari data logger yang terpasang pada sistem. Penelitian merupakan simulasi pada Simulink MATLAB. Beberapa kapasitas supercapasitor dipilih untuk mengetahui perubahan kinerja sistem. Hasil simulasi menunjukkan bahwa kapasitas superkapasitor berpengaruh signifikan terhadap arus dan tegangan pada baterai. Superkapasitor menunjukkan kemampuan menyerap dan melepaskan arus besar dalam waktu relatif singkat sehingga mempercepat proses pengisian baterai. Superkapasitor berkapasitas setara kapasitas baterai mempunyai konstribusi terbaik pada kinerja sistem. Kata Kunci: Baterai, Sistem PV Atap Off-grid, Superkapasitor.