Jong-Ho Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jong-Ho Kim has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Dong-Ki Kim
Korea Research Institute of Standards and Science
3 shared publicationsHyun-Joon Kwon
University of Maryland
3 shared publicationsYoung-Ha Kwon
Kyung-Hee University
3 shared publications- Alchan Yun
Robot Center, Samsung Research, Seoul 06765, Korea
1 shared publication Dae-Im Kang
Division of Physical Metrology, Korea Research Institute of Standards and Science (KRISS), Daejeon, South Korea
1 shared publication- Eungseok Oh
Department of Neurology, Chungnam National University Hospital, Chungnam National University College of Medicine, Daejeon, Korea
1 shared publication
Latest Publications
- 6 March 2026
- Published by Springer Nature in Journal of Neurology
- Vol. 273 (3)
Balance biomarker for early differentiation of Parkinson’s disease and multiple system atrophy with parkinsonian type
Parkinson's disease (PD) and multiple system atrophy with parkinsonian type (MSA-P) share various motor and nonmotor symptoms, complicating early differential diagnosis, although prognosis and levodopa response differ. To develop a machine learning model using balance analysis to differentiate early-stage PD and MSA-P. We enrolled 22 healthy controls (HC), 20 PD, and 17 MSA-P patients within three years of onset. Participants stood for 60 s on dual force-plates under eyes open (EO) and eyes closed (EC). Seven center of pressure (COP) parameters per condition and EC-EO differences were analyzed. Group differences were assessed with ANOVA. Feature selection was performed using LightGBM (LGBM), followed by model training with fourfold cross-validation. Mean ages were 63.8 (HC), 64.2 (PD), and 68.8 years (MSA-P). Disease durations were 2.4 years in PD and 1.8 years in MSA-P. Except for mean distance in the anteroposterior direction with EO and 95% confidence ellipse area with EC, all parameters showed significant group differences. Post-hoc analysis revealed significant differences between HC and PD/MSA-P in EO, whereas in EC, differences were more pronounced between MSA-P and PD/HC. The LGBM model achieved 81.4% accuracy in distinguishing PD from MSA-P, 94.9% in distinguishing healthy controls from patient groups, and 84.9% for three-group classification. Balance biomarker, which analyzes the balance parameters with machine learning model could differentiate early-stage PD and MSA-P with high accuracy.
- 6 March 2026
- Published by Springer Nature in Journal of Neurology
- Vol. 273 (3)
Balance biomarker for early differentiation of Parkinson’s disease and multiple system atrophy with parkinsonian type
Parkinson's disease (PD) and multiple system atrophy with parkinsonian type (MSA-P) share various motor and nonmotor symptoms, complicating early differential diagnosis, although prognosis and levodopa response differ. To develop a machine learning model using balance analysis to differentiate early-stage PD and MSA-P. We enrolled 22 healthy controls (HC), 20 PD, and 17 MSA-P patients within three years of onset. Participants stood for 60 s on dual force-plates under eyes open (EO) and eyes closed (EC). Seven center of pressure (COP) parameters per condition and EC-EO differences were analyzed. Group differences were assessed with ANOVA. Feature selection was performed using LightGBM (LGBM), followed by model training with fourfold cross-validation. Mean ages were 63.8 (HC), 64.2 (PD), and 68.8 years (MSA-P). Disease durations were 2.4 years in PD and 1.8 years in MSA-P. Except for mean distance in the anteroposterior direction with EO and 95% confidence ellipse area with EC, all parameters showed significant group differences. Post-hoc analysis revealed significant differences between HC and PD/MSA-P in EO, whereas in EC, differences were more pronounced between MSA-P and PD/HC. The LGBM model achieved 81.4% accuracy in distinguishing PD from MSA-P, 94.9% in distinguishing healthy controls from patient groups, and 84.9% for three-group classification. Balance biomarker, which analyzes the balance parameters with machine learning model could differentiate early-stage PD and MSA-P with high accuracy.
- Open Access
Development of a Robot Arm Link System Embedded with a Three-Axis Sensor with a Simple Structure Capable of Excellent External Collision Detection
In order to effectively detect the contact state between the operator and the collaborative robot, a sensor with excellent external force detection performance is needed. The existing force/torque sensor and joint torque sensor, which are the two main external force sensors methods in cooperative robots, have limitations; only the force exerted at the end effector is detected, and it induces a low stiffness in the overall structure which affects the control performance. In the case of sensorless collision detection methods that utilize the current sensor that is used for motor control, the estimation of the performance of external force is sensitive to the sensor noise and dynamic model accuracy only to the extent that it can be used for collision detection. In this paper, we propose a strain gauge-based three-axis sensor of a cylindrical shape, which is often used as a link in a robot. By integrating sensors with robot links, the external force can be precisely measured without compromising the stiffness and is decoupled with joint disturbances, such as motor friction. Sensor calibration is conducted using static load evaluation equipment, and the reliability of collision detection is confirmed by comparing the theoretical/structural analysis results. Through the weight test and sensor characteristic evaluation, the performance and output stability are validated.
Open AccessDevelopment of a Robot Arm Link System Embedded with a Three-Axis Sensor with a Simple Structure Capable of Excellent External Collision Detection
In order to effectively detect the contact state between the operator and the collaborative robot, a sensor with excellent external force detection performance is needed. The existing force/torque sensor and joint torque sensor, which are the two main external force sensors methods in cooperative robots, have limitations; only the force exerted at the end effector is detected, and it induces a low stiffness in the overall structure which affects the control performance. In the case of sensorless collision detection methods that utilize the current sensor that is used for motor control, the estimation of the performance of external force is sensitive to the sensor noise and dynamic model accuracy only to the extent that it can be used for collision detection. In this paper, we propose a strain gauge-based three-axis sensor of a cylindrical shape, which is often used as a link in a robot. By integrating sensors with robot links, the external force can be precisely measured without compromising the stiffness and is decoupled with joint disturbances, such as motor friction. Sensor calibration is conducted using static load evaluation equipment, and the reliability of collision detection is confirmed by comparing the theoretical/structural analysis results. Through the weight test and sensor characteristic evaluation, the performance and output stability are validated.
- 4 January 2021
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 78 (2) , 124-129
Development of a refractive index measurement system for vacuum pressure measurement
- 4 January 2021
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 78 (2) , 124-129
Development of a refractive index measurement system for vacuum pressure measurement
- 10 February 2016
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 8 (10) , 5667-5675
Enhanced performance in capacitive force sensors using carbon nanotube/polydimethylsiloxane nanocomposites with high dielectric properties
Force sensors have attracted tremendous attention owing to their applications in various fields such as touch screens, robots, smart scales, and wearable devices. The force sensors reported so far have been mainly focused on high sensitivity based on delicate microstructured materials, resulting in low reproducibility and high fabrication cost that are limitations for wide applications. As an alternative, we demonstrate a novel capacitive-type force sensor with enhanced performance owing to the increased dielectric properties of elastomers and simple sensor structure. We rationally design dielectric elastomers based on alkylamine modified-multi-walled carbon nanotube (MWCNT)/polydimethylsiloxane (PDMS) composites, which have a higher dielectric constant than pure PDMS. The alkylamine-MWCNTs show excellent dispersion in a PDMS matrix, thus leading to enhanced and reliable dielectric properties of the composites. A force sensor array fabricated with alkylamine-MWCNT/PDMS composites presents an enhanced response due to the higher dielectric constant of the composites than that of pure PDMS. This study is the first to report enhanced performance of capacitive force sensors by modulating the dielectric properties of elastomers. We believe that the disclosed strategy to improve the sensor performance by increasing the dielectric properties of elastomers has great potential in the development of capacitive force sensor arrays that respond to various input forces.
- 10 February 2016
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 8 (10) , 5667-5675
Enhanced performance in capacitive force sensors using carbon nanotube/polydimethylsiloxane nanocomposites with high dielectric properties
Force sensors have attracted tremendous attention owing to their applications in various fields such as touch screens, robots, smart scales, and wearable devices. The force sensors reported so far have been mainly focused on high sensitivity based on delicate microstructured materials, resulting in low reproducibility and high fabrication cost that are limitations for wide applications. As an alternative, we demonstrate a novel capacitive-type force sensor with enhanced performance owing to the increased dielectric properties of elastomers and simple sensor structure. We rationally design dielectric elastomers based on alkylamine modified-multi-walled carbon nanotube (MWCNT)/polydimethylsiloxane (PDMS) composites, which have a higher dielectric constant than pure PDMS. The alkylamine-MWCNTs show excellent dispersion in a PDMS matrix, thus leading to enhanced and reliable dielectric properties of the composites. A force sensor array fabricated with alkylamine-MWCNT/PDMS composites presents an enhanced response due to the higher dielectric constant of the composites than that of pure PDMS. This study is the first to report enhanced performance of capacitive force sensors by modulating the dielectric properties of elastomers. We believe that the disclosed strategy to improve the sensor performance by increasing the dielectric properties of elastomers has great potential in the development of capacitive force sensor arrays that respond to various input forces.
- 15 May 2015
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 16 (5) , 981-988
Force sensing model of capacitive hybrid touch sensor using thin-film force sensor and its evaluation
- 15 May 2015
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 16 (5) , 981-988
Force sensing model of capacitive hybrid touch sensor using thin-film force sensor and its evaluation
- 1 October 2012
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 26 (10) , 3269-3276
Fabrication of robot head module using contact-resistance force sensor for human-robot interaction and its evaluation
- 1 October 2012
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 26 (10) , 3269-3276
Fabrication of robot head module using contact-resistance force sensor for human-robot interaction and its evaluation
- 1 February 2011
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 25 (2) , 543-548
Fabrication of four-point biped robot foot module based on contact-resistance force sensor and its evaluation
- 1 February 2011
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 25 (2) , 543-548
Fabrication of four-point biped robot foot module based on contact-resistance force sensor and its evaluation
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1468-1472
Development of tactile sensor with functions of contact force and thermal sensing for attachment to intelligent robot finger tip
This paper describes the design and fabrication of a flexible tactile sensor using polymer micromachining technologies, which can measure the three-component force and temperature caused by thermal conductivity. The tactile sensor is comprised of sixteen micro force sensors with 4 times 4 arrays and its size being 13 mm times 18 mm. Each micro force sensor has a square membrane, and its force capacity is 0.6 N in the three axis directions. The normal and shear forces are obtained from four thin-film metal strain gauges embedded in a polyimide thin-film membrane. The optimal positions of the strain gauges are determined by the strain distribution obtained form finite element analysis. In order to acquire force and temperature signals simultaneously from the fabricated tactile sensor, we fabricated a PCB based on multiplexer, operational amplifier and microprocessor with CAN network function. The fabricated flexible tactile sensor was evaluated from the evaluation apparatus. Also we confirmed that the sensor has the function of temperature sensing throughout feasibility test such as contacting with some objects.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1468-1472
Development of tactile sensor with functions of contact force and thermal sensing for attachment to intelligent robot finger tip
This paper describes the design and fabrication of a flexible tactile sensor using polymer micromachining technologies, which can measure the three-component force and temperature caused by thermal conductivity. The tactile sensor is comprised of sixteen micro force sensors with 4 times 4 arrays and its size being 13 mm times 18 mm. Each micro force sensor has a square membrane, and its force capacity is 0.6 N in the three axis directions. The normal and shear forces are obtained from four thin-film metal strain gauges embedded in a polyimide thin-film membrane. The optimal positions of the strain gauges are determined by the strain distribution obtained form finite element analysis. In order to acquire force and temperature signals simultaneously from the fabricated tactile sensor, we fabricated a PCB based on multiplexer, operational amplifier and microprocessor with CAN network function. The fabricated flexible tactile sensor was evaluated from the evaluation apparatus. Also we confirmed that the sensor has the function of temperature sensing throughout feasibility test such as contacting with some objects.