FFFarzad Fereidouni

Farzad Fereidouni

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Farzad Fereidouni has a total of 102 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Slide-free, point-of-care imaging of core needle biopsies for rapid histologic assessment

    by Dena Sayrafi, Sarah Rezapourdamanab, Eugenie Dulout, Richard Levenson, Eric Seibel, Romil Saxena, Alexander Borowsky, Michael C. Larson, Farzad Fereidouni

    Histological evaluation of core needle biopsies (CNB) using formalin-fixed, paraffin-embedded (FFPE) slides remains slow and resource-intensive, with up to 15% of samples identified as inadequate only after post-processing review. We introduce CoreLab, a compact optical imaging system designed for real-time, slide-free imaging of fresh CNB specimens using fluorescence-imitating brightfield imaging (FIBI). CoreLab integrates tissue collection, rapid H&E staining, and optical imaging into a single workflow, allowing intact biopsy cores to be imaged within five minutes of acquisition without sectioning, compression, or glass mounting, while preserving specimen integrity and supporting downstream histology compatibility. Preliminary FIBI imaging across multiple tissue types, including breast, liver, kidney, and adipose tissue, showed high structural correspondence with standard histology. CoreLab demonstrates the feasibility of intra-procedural, slide-free visualization of intact biopsy specimens. It has the potential to support immediate biopsy adequacy assessment, and provide preliminary histological insight, thereby reducing the need for repeat procedures and accelerating clinical decision-making.

  • Open Access

    Validation of virtual trichrome stains for kidney fibrosis evaluation using dual-mode emission and transmission microscopy

    by Willy Ju, Samuel Border, Fatemeh Afsari, Srishti Seth, Sarah Rezapourdamanab, Ruben Renteria, Shalini S. Ramachandra, Rajib Gupta, Fadi Salem, Alton B. Farris, et al.

    Assessment of interstitial fibrosis is essential in the diagnosis and prognosis of kidney diseases. However, current histologic scoring methods using trichrome-stained slides are limited by inter-observer variability and inconsistent stain reproducibility. To address these challenges, we developed DUET (DUal-mode Emission and Transmission) microscopy, a novel imaging platform that rapidly captures both brightfield and fluorescence images from H&E-stained slides to generate pixel-registered collagen images and virtual trichrome stains. In a cohort of 32 kidney transplant biopsies, four renal pathologists estimated the extent of interstitial fibrosis in real trichrome and DUET-derived virtual trichrome whole slide images, with the latter showing improved inter-pathologist agreement. A deep learning pipeline was trained to segment interstitial kidney regions from DUET-acquired images, enabling semi-automated computational fibrosis quantitation, which demonstrated a positive correlation with pathologists’ estimates of interstitial fibrosis. These findings highlight DUET as a rapid, cost-effective, and scalable alternative to traditional trichrome staining, offering both visual and computational advantages.


  • Open Access

    Improving Frozen Kidney Biopsy Interpretation Using DUET-Generated Virtual PAS Stains

    by Kuang-Yu Jen, Willy Ju, Srishti Seth, Ruby Mascareno, Ruben Carlos Renteria, Sarah Rezapourdamanab, Shalini Ramachandra, Jayla Hernandez, Sam Border, Ashna Aggarwal, et al.

    Frozen section biopsies stained with Hematoxylin & Eosin (H&E) are standard for assessing donor kidneys but are often interpreted by general pathologists with limited renal expertise, and hindered by freezing artifacts and poor tissue morphology. There is currently no rapid, cost-effective, and easily deployable method for generating virtual special stains and quantifying clinically significant histopathological features on frozen section H&E slides. This study evaluates the utility of DUET-generated virtual Periodic acid-Schiff (vPAS) stains produced from H&E-stained frozen kidney biopsies. DUET produces virtual PAS by combining pixel-registered brightfield and fluorescence images from the frozen section H&E-stained slide, overlaying extracted collagen masks to generate the virtual stain. Renal and general pathologists evaluated interstitial fibrosis/tubular atrophy (IF/TA), inflammation, and arteriosclerosis on 29 kidney biopsies, comparing their assessments using H&E images alone versus using both H&E and virtual PAS images. Among general pathologists’ evaluations, ICC scores from the H&E to virtual PAS stain increased for IF/TA percentage, inflammation percentage, and arteriosclerosis number. For renal pathologists’ evaluations, ICC scores from the H&E to virtual PAS stain increased for the percentage of sclerotic glomeruli, IF/TA percentage, inflammation percentage, and number of arteriosclerotic lesions. No improvement in ICC score was observed for arteriolar hyalinosis in either pathologist’s group. We have demonstrated that the use of frozen virtual PAS stains enables higher consistency among pathologist evaluations when compared to the use of frozen section H&E alone for various metrics used to assess donor kidney viability. This approach has the potential to reduce diagnostic variability, improve transplant decision-making, and optimize donor kidney utilization.

  • Open Access

    CollagenFitJ, a FIJI plugin for the quantification of collagen in polarization-resolved second harmonic generation image sets

    by Radu Hristu, Farzad Fereidouni, Stefan G. Stanciu, Lucian G. Eftimie, Oana C. Voinea, Danielis Rutkauskas, Laura Sironi, Giuseppe Chirico, Denis E. Tranca, Remus R. Glogojeanu, et al.

    Collagen is the most abundant protein in the human body and the main component of the extracellular matrix,1 playing essential structural2 and regulatory roles3,4 in tissue organization, development, and disease. Given its importance, various imaging techniques have been employed to assess collagen structure and behavior. Although the usefulness of non-optical methods for collagen assessment (e.g., ultrasound imaging,5 magnetic resonance imaging,6 and positron emission tomography7) cannot be disputed, optical methods are typically non-ionizing and safer than other medical imaging approaches and offer the best spatiotemporal resolution for non-invasive imaging of collagen.


  • Open Access

    NerveTracker: a Python-based software toolkit for visualizing and tracking groups of nerve fibers in serial block-face microscopy with ultraviolet surface excitation images

    by Chaitanya Kolluru, Naomi Joseph, James Seckler, Farzad Fereidouni, Richard Levenson, Andrew Shoffstall, Michael Jenkins, David Wilson

    Peripheral neuromodulation is a growing area of research that involves the application of external stimuli to modulate nerve activity.1 Although these methods have been applied to treat various disease conditions, the effectiveness of these therapies has been limited. For instance, vagus nerve stimulation (VNS) is a clinically approved therapy to treat conditions such as drug-resistant epilepsy,2 depression,3 and obesity.4 However, therapeutic efficacy with this method is just moderate, with 50% of patients seeing a significant (>50%) reduction in seizure frequency after 1 year of implantation.5 In addition, several trials involving VNS therapy have failed to reach clinical endpoints.6,7 We find that computational modeling approaches can aid researchers to test various interface designs and identify ideal stimulation parameters (pulse amplitude, width, duty cycle, etc.); these could serve to improve fiber selectivity and thereby increase therapeutic efficacy. However, these models require accurate anatomical information about human nerve morphology since the latter significantly affects optimal stimulation parameters.8 Therefore, there is a need for methods that enable visualization and mapping of human peripheral nerves to improve computational models, providing a deeper understanding of nerve responses to neuromodulation therapies and enhancing treatment outcomes.


  • Open Access

    Neuropathological Applications of Microscopy with Ultraviolet Surface Excitation (MUSE): A Concordance Study of Human Primary and Metastatic Brain Tumors

    by Mirna Lechpammer, Austin Todd, Vivian Tang, Taryn Morningstar, Alexander Borowsky, Kiarash Shahlaie, John A. Kintner, John D. McPherson, John W. Bishop, Farzad Fereidouni, et al.

    Whereas traditional histology and light microscopy require multiple steps of formalin fixation, paraffin embedding, and sectioning to generate images for pathologic diagnosis, Microscopy using Ultraviolet Surface Excitation (MUSE) operates through UV excitation on the cut surface of tissue, generating images of high resolution without the need to fix or section tissue and allowing for potential use for downstream molecular tests. Here, we present the first study of the use and suitability of MUSE microscopy for neuropathological samples. MUSE images were generated from surgical biopsy samples of primary and metastatic brain tumor biopsy samples (n = 27), and blinded assessments of diagnoses, tumor grades, and cellular features were compared to corresponding hematoxylin and eosin (H&E) images. A set of MUSE-treated samples subsequently underwent exome and targeted sequencing, and quality metrics were compared to those from fresh frozen specimens. Diagnostic accuracy was relatively high, and DNA and RNA integrity appeared to be preserved for this cohort. This suggests that MUSE may be a reliable method of generating high-quality diagnostic-grade histologic images for neuropathology on a rapid and sample-sparing basis and for subsequent molecular analysis of DNA and RNA.


  • GigaFIBI; Rapid, Large-format Histology-resolution Imaging for Intraoperative Assessment of Breast Lumpectomy Margins

    by Dena Sayrafi, Nate Anderson, Candice Sauder, Diana Miglioretti, Richard Levenson, Alexander Borowsky, Farzad Fereidouni

    GigaFIBI, an advancement of Fluorescence Imitating Brightfield Imaging (FIBI), displays significant promise in reducing positive margins and associated costs by capturing histology-grade images of 100x100 within minutes, offering intraoperative guidance.

  • Anatomy-Specific Classification Model Using Label-Free FLIm to Aid Intraoperative Surgical Guidance of Head and Neck Cancer

    by Mohamed Abul Hassan, Brent W Weyers, Julien Bec, Farzad Fereidouni, Jinyi Qi, Dorina Gui, Arnaud F. Bewley, Marianne Abouyared, D. Gregory Farwell, Andrew C. Birkeland, et al.

    Intraoperative identification of head and neck cancer tissue is essential to achieve complete tumor resection and mitigate tumor recurrence. Mesoscopic fluorescence lifetime imaging (FLIm) of intrinsic tissue fluorophores emission has demonstrated the potential to demarcate the extent of the tumor in patients undergoing surgical procedures of the oral cavity and the oropharynx. Here, we report FLIm-based classification methods using standard machine learning models that account for the diverse anatomical and biochemical composition across the head and neck anatomy to improve tumor region identification. Three anatomy-specific binary classification models were developed (i.e., “base of tongue,” “palatine tonsil,” and “oral tongue”). FLIm data from patients (N = 85) undergoing upper aerodigestive oncologic surgery were used to train and validate the classification models using a leave-one-patient-out cross-validation method. These models were evaluated for two classification tasks: (1) to discriminate between healthy and cancer tissue, and (2) to apply the binary classification model trained on healthy and cancer to discriminate dysplasia through transfer learning. This approach achieved superior classification performance compared to models that are anatomy-agnostic; specifically, a ROC-AUC of 0.94 was for the first task and 0.92 for the second. Furthermore, the model demonstrated detection of dysplasia, highlighting the generalization of the FLIm-based classifier. Current findings demonstrate that a classifier that accounts for tumor location can improve the ability to accurately identify surgical margins and underscore FLIm's potential as a tool for surgical guidance in head and neck cancer patients, including those subjects of robotic surgery


  • Open Access

    First in patient assessment of brain tumor infiltrative margins using simultaneous time-resolved measurements of 5-ALA-induced PpIX fluorescence and tissue autofluorescence

    by Alba Alfonso-García, Xiangnan Zhou, Julien Bec, Silvia N. Anbunesan, Farzad Fereidouni, Lee-Way Jin, Han Sung Lee, Orin Bloch, Laura Marcu

    Fluorescence-guided surgery (FGS) for primary brain tumor (glioma) resection using 5-aminolevulinic acid (5-ALA) improves the extent of tumor resection in high-grade glioma patients, directly impacting patient survival. Its use is a widespread practice in Europe and is rapidly gaining popularity in the United States.1 Oral administration of 5-ALA results in selective accumulation of protoporphyrin IX (PpIX) in tumor cells.2 In glioblastoma (GBM) patients, PpIX fluorescence (emission peak at 635 nm upon 405 nm excitation3) is strong enough for visual assessment using a surgical microscope, and it enables guided tumor resection. However, for the low-cellularity infiltrating edge of high-grade gliomas and most low-grade gliomas, the PpIX fluorescence intensity decreases below the visible threshold.4 Current implementations of PpIX fluorescence visualization systems require working in a dark surgical field, hindering simultaneous tumor identification and resection. Additionally, visible PpIX fluorescence suffers from non-specific intensity variations (e.g., non-uniform illumination) that complicate the quantitative assessment of tumor with high accuracy.5 Recent studies conducted on excised brain tissue have suggested that fluorescence spectroscopy and lifetime imaging enable further quantification of PpIX fluorescence below the visible detection threshold.6,7 Time-resolved fluorescence is expected to increase the detection sensitivity of areas with weak fluorescence intensity because fluorescence lifetime is largely independent of tissue absorption and scattering properties, and unlike intensity alone, it is robust to variations in tissue-detector distance.


  • Open Access

    Pocket MUSE: an affordable, versatile and high-performance fluorescence microscope using a smartphone

    by Yehe Liu, Andrew M. Rollins, Richard M. Levenson, Farzad Fereidouni, Michael W. Jenkins

    Smartphone microscopes can be useful tools for a broad range of imaging applications. This manuscript demonstrates the first practical implementation of Microscopy with Ultraviolet Surface Excitation (MUSE) in a compact smartphone microscope called Pocket MUSE, resulting in a remarkably effective design. Fabricated with parts from consumer electronics that are readily available at low cost, the small optical module attaches directly over the rear lens in a smartphone. It enables high-quality multichannel fluorescence microscopy with submicron resolution over a 10× equivalent field of view. In addition to the novel optical configuration, Pocket MUSE is compatible with a series of simple, portable, and user-friendly sample preparation strategies that can be directly implemented for various microscopy applications for point-of-care diagnostics, at-home health monitoring, plant biology, STEM education, environmental studies, etc.