Mustafa Salih Al Musawi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mustafa Salih Al Musawi has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
B. Al-Gailani
Department of Physiology, College of Medicine, Al-Mustansiriya University, Baghdad, Iraq
3 shared publicationsFatanah M. Suhaimi
Advanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam, 13200, Kepala Batas, P. Pinang, Malaysia
3 shared publicationsM. S. Jaafar
School of Physics, Universiti Sains Malaysia, 11800, Gelugor, Pulau Pinang, Malaysia
3 shared publicationsNaser M. Ahmed
School of Physics, Universiti Sains Malaysia, 11800, Gelugor, Pulau Pinang, Malaysia
3 shared publications- Nursakinah Suardi
School of Physics, Universiti Sains Malaysia, Gelugor, Malaysia
2 shared publications Wisam Majeed Kattoof
Department of Physiology and Medical Physics, Mustansiriyah University, Baghdad, Iraq
2 shared publications
Latest Publications
- Open Access
- 28 September 2024
- Published by Pakistan Medical Association in Journal of the Pakistan Medical Association
- Vol. 74 (10 (Supple) , S186-S190
The efficacy of combined Intense pulsed light plus high-intensity focussed ultrasound with two different powers in the treatment of atrophic and Icepick acne scars
Objective: To determine the clinical efficacy and suitable power of high-intensity focussed ultrasound combined with intense pulsed light to treat acne scarring. Methods: The prospective study was conducted at the College of Medicine, Mustansiriyah University, Baghdad, Iraq, from September 2020 to March 2021, and comprised patients of either gender with atrophic or icepick scars. They were divided into atrophic scar group A and icepick scar group B. Both groups were first treated with intense pulsed light and then with high-intensity focussed ultrasound using 30J/cm2 and 40J/cm2 power. There were overall 4 sessions with an interval of 4 weeks. The outcome was assessed using the Patient and Observer Scar Assessment Scale. Data was analysed using SPSS 25. Results: Of the 22 patients with a mean age of 20.86±3.22 years, there were 11patients in group A; 7(70%) females and 4(30%) males with a mean age of 20.5±2.06 years. There were 11patients in group B; 7(70%) males and 4(30%) females with a mean age of 21.27±4.19 years. There was a significant difference between baseline and post-intervention scores for both groups (p<0.05), and power 30J/cm2 was significantly better compared to 40J/cm2 (p<0.05). Conclusion: The developing technique using high-intensity focussed ultrasound and intense pulsed light was found to be effective in treating scars with 30J/cm2 power. Key Words: Cicatrix, Tissue diseases, Atrophy, Acne vulgaris, Icepick.
- 28 September 2024
- Published by Pakistan Medical Association in Journal of the Pakistan Medical Association
- Vol. 74 (10 (Supple) , S186-S190
Open AccessThe efficacy of combined Intense pulsed light plus high-intensity focussed ultrasound with two different powers in the treatment of atrophic and Icepick acne scars
Objective: To determine the clinical efficacy and suitable power of high-intensity focussed ultrasound combined with intense pulsed light to treat acne scarring. Methods: The prospective study was conducted at the College of Medicine, Mustansiriyah University, Baghdad, Iraq, from September 2020 to March 2021, and comprised patients of either gender with atrophic or icepick scars. They were divided into atrophic scar group A and icepick scar group B. Both groups were first treated with intense pulsed light and then with high-intensity focussed ultrasound using 30J/cm2 and 40J/cm2 power. There were overall 4 sessions with an interval of 4 weeks. The outcome was assessed using the Patient and Observer Scar Assessment Scale. Data was analysed using SPSS 25. Results: Of the 22 patients with a mean age of 20.86±3.22 years, there were 11patients in group A; 7(70%) females and 4(30%) males with a mean age of 20.5±2.06 years. There were 11patients in group B; 7(70%) males and 4(30%) females with a mean age of 21.27±4.19 years. There was a significant difference between baseline and post-intervention scores for both groups (p<0.05), and power 30J/cm2 was significantly better compared to 40J/cm2 (p<0.05). Conclusion: The developing technique using high-intensity focussed ultrasound and intense pulsed light was found to be effective in treating scars with 30J/cm2 power. Key Words: Cicatrix, Tissue diseases, Atrophy, Acne vulgaris, Icepick.
- Open Access
- 2 June 2023
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 14, 188
Design and manufacturing of a head mask for fixation in stereotactic radiosurgery by the Gamma Knife® Icon™
Background: This study evaluates an alternative to the classical method of head fixation during Gamma Knife radiosurgery using a Leksell head frame. In the Gamma Knife® Icon™ model, a new method of head fixation is used by utilizing a thermal molded polymer mask that takes the shape of the patient’s head before fixing the head to the table. However, this mask is for single use and quite expensive. Methods: We describe a new, very economical method to fix the head of the patient during radiosurgery. We used commercial, quite cheap material [polylactic acid (PLA)] plastic and made a 3D printing model for the patient’s face, taking special measurements to put this mask and fix it on the Gamma Knife. The actual material cost is only $4 (100 times less than the original mask cost). Results: The new mask efficiency was tested using the movement checker software, the same one used to measure the efficiency of the original mask. Conclusion: The newly designed and manufactured mask is quite effective for use with the Gamma Knife® Icon™, with a much lower cost, and it can be manufactured locally.
- 2 June 2023
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 14, 188
Open AccessDesign and manufacturing of a head mask for fixation in stereotactic radiosurgery by the Gamma Knife® Icon™
Background: This study evaluates an alternative to the classical method of head fixation during Gamma Knife radiosurgery using a Leksell head frame. In the Gamma Knife® Icon™ model, a new method of head fixation is used by utilizing a thermal molded polymer mask that takes the shape of the patient’s head before fixing the head to the table. However, this mask is for single use and quite expensive. Methods: We describe a new, very economical method to fix the head of the patient during radiosurgery. We used commercial, quite cheap material [polylactic acid (PLA)] plastic and made a 3D printing model for the patient’s face, taking special measurements to put this mask and fix it on the Gamma Knife. The actual material cost is only $4 (100 times less than the original mask cost). Results: The new mask efficiency was tested using the movement checker software, the same one used to measure the efficiency of the original mask. Conclusion: The newly designed and manufactured mask is quite effective for use with the Gamma Knife® Icon™, with a much lower cost, and it can be manufactured locally.
- 1 December 2021
- Vol. 71 (12) , S161-S165
Fast tattoo removal using Q-Switching ND-YAG laser technique with multi pass sessions
Laser therapy is the gold standard method to remove unwanted tattoos. It is available and widely accessible. This study was done to assess the efficacy of the R20 method (multi-time separated passes in one session for 20 min) using Q-switched ND: YAG laser for the removal of tattoos and was compared with the traditional method. Forty patients with 40 Tattoos were included. These tattoos were separated into two halves left and right. One half was treated with a single pass and the other half with R20. Both halves were treated using Q-switched ND-YAG laser with 10 J/cm(2), 1.064 mu m, 8 ns pulse width, and 3 mm spot size. The treatment regimen included three sessions at three-week intervals. Tattoo bleaching was evaluated in each session by means of using the imaging process by two dermatologists. It could be concluded that the treatment with traditional single-pass is less effective than the R20 method in the three-month period. Epidermal healing period needs more than three weeks with the R20 method. The amateur tattoos have a significantly better response than professional tattoos. The R20 method is better than the traditional method to remove a tattoo, where most tattoos can be removed in one session. Amateur tattoo is removed faster compared to professional tattoo using R20 method because amateur tattoo affects the skin surface.
- 1 December 2021
- Vol. 71 (12) , S161-S165
Fast tattoo removal using Q-Switching ND-YAG laser technique with multi pass sessions
Laser therapy is the gold standard method to remove unwanted tattoos. It is available and widely accessible. This study was done to assess the efficacy of the R20 method (multi-time separated passes in one session for 20 min) using Q-switched ND: YAG laser for the removal of tattoos and was compared with the traditional method. Forty patients with 40 Tattoos were included. These tattoos were separated into two halves left and right. One half was treated with a single pass and the other half with R20. Both halves were treated using Q-switched ND-YAG laser with 10 J/cm(2), 1.064 mu m, 8 ns pulse width, and 3 mm spot size. The treatment regimen included three sessions at three-week intervals. Tattoo bleaching was evaluated in each session by means of using the imaging process by two dermatologists. It could be concluded that the treatment with traditional single-pass is less effective than the R20 method in the three-month period. Epidermal healing period needs more than three weeks with the R20 method. The amateur tattoos have a significantly better response than professional tattoos. The R20 method is better than the traditional method to remove a tattoo, where most tattoos can be removed in one session. Amateur tattoo is removed faster compared to professional tattoo using R20 method because amateur tattoo affects the skin surface.
- Retracted
- 29 April 2021
- Published by Springer Nature in Applied Nanoscience
- Vol. 13 (1) , 549
RETRACTED ARTICLE: Dosimetric assessment of IMRT treatment planning for unilateral breast cancer patient using Octavius phantom detector
- 29 April 2021
- Published by Springer Nature in Applied Nanoscience
- Vol. 13 (1) , 549
RetractedRETRACTED ARTICLE: Dosimetric assessment of IMRT treatment planning for unilateral breast cancer patient using Octavius phantom detector
- Retracted
- 28 April 2021
- Published by Springer Nature in Applied Nanoscience
- Vol. 13 (3) , 1751
RETRACTED ARTICLE: ATP level in red blood cells improves by altering the low-level DPSS laser irradiation condition
- 28 April 2021
- Published by Springer Nature in Applied Nanoscience
- Vol. 13 (3) , 1751
RetractedRETRACTED ARTICLE: ATP level in red blood cells improves by altering the low-level DPSS laser irradiation condition
- 1 November 2020
- Published by SAGE Publications in Photobiomodulation, Photomedicine, and Laser Surgery
- Vol. 38 (11) , 667-672
In Vitro Biostimulation of Low-Power Diode Pumping Solid State Laser Irradiation on Human Serum Proteins
Objective: This research is conducted to clarify whether the action of low-power diode pumping solid state (DPSS) laser doses modify proteins of normal human blood serum in vitro. Background data: Low-power laser light is considered to act through biostimulation rather than through thermal effects. It was found that low-power laser light biostimulates various biological processes, such as increasing the blood flow within the microcirculation. Methods: Human blood serum samples were carefully collected and divided into five equal aliquots. One of them served as a control (nonirradiated serum) and the other four aliquots were irradiated by DPSS laser at a wavelength of 589 nm with different doses (50, 70, 90, and 110 J/cm2). The electrophoretic migration speeds of each specific protein were measured immediately after irradiation using protein electrophoresis. A paired Student's t-test was used between variables. Results: The protein concentrations were not significantly (p > 0.05) changed by the various doses of DPSS laser comparing with the nonirradiated counterpart. The electrophoretic migration speed of serum proteins was significantly decreased in almost all tested doses relative to the nonirradiated counterpart. Moreover, the irradiation of serum proteins (albumin, alpha1, alpha 2, beta, and globulin) with a laser dose of 70 J/cm2 was associated with a significant decrease (p < 0.003, 0.02, 0.002, 0.02 and 0.001, respectively) in protein migration speed compared with the protein migration speed of the control nonirradiated counterpart. Conclusions: Laser light at a wavelength of 589 nm induces processes that lead to decreases in serum protein migration speeds. Globulin protein was found to have the lowest migration speed among the other plasma proteins.
- 1 November 2020
- Published by SAGE Publications in Photobiomodulation, Photomedicine, and Laser Surgery
- Vol. 38 (11) , 667-672
In Vitro Biostimulation of Low-Power Diode Pumping Solid State Laser Irradiation on Human Serum Proteins
Objective: This research is conducted to clarify whether the action of low-power diode pumping solid state (DPSS) laser doses modify proteins of normal human blood serum in vitro. Background data: Low-power laser light is considered to act through biostimulation rather than through thermal effects. It was found that low-power laser light biostimulates various biological processes, such as increasing the blood flow within the microcirculation. Methods: Human blood serum samples were carefully collected and divided into five equal aliquots. One of them served as a control (nonirradiated serum) and the other four aliquots were irradiated by DPSS laser at a wavelength of 589 nm with different doses (50, 70, 90, and 110 J/cm2). The electrophoretic migration speeds of each specific protein were measured immediately after irradiation using protein electrophoresis. A paired Student's t-test was used between variables. Results: The protein concentrations were not significantly (p > 0.05) changed by the various doses of DPSS laser comparing with the nonirradiated counterpart. The electrophoretic migration speed of serum proteins was significantly decreased in almost all tested doses relative to the nonirradiated counterpart. Moreover, the irradiation of serum proteins (albumin, alpha1, alpha 2, beta, and globulin) with a laser dose of 70 J/cm2 was associated with a significant decrease (p < 0.003, 0.02, 0.002, 0.02 and 0.001, respectively) in protein migration speed compared with the protein migration speed of the control nonirradiated counterpart. Conclusions: Laser light at a wavelength of 589 nm induces processes that lead to decreases in serum protein migration speeds. Globulin protein was found to have the lowest migration speed among the other plasma proteins.
- 2 October 2017
- Published by Springer Nature in Lasers in Medical Science
- Vol. 32 (9) , 2089-2095
Laser-induced changes of in vitro erythrocyte sedimentation rate
- 2 October 2017
- Published by Springer Nature in Lasers in Medical Science
- Vol. 32 (9) , 2089-2095
Laser-induced changes of in vitro erythrocyte sedimentation rate
- 3 January 2017
- Published by Springer Nature in Lasers in Medical Science
- Vol. 32 (2) , 405-411
Effects of low-level laser irradiation on human blood lymphocytes in vitro
Low-level laser irradiation (LLLI) has various effects on cultured human lymphocytes in vitro, but little is known about such effects in whole blood. This study investigated whether LLLI affected lymphocyte count in human whole blood in vitro. A total number of 130 blood samples were collected from apparently healthy adult patients through venipuncture into tubes containing EDTA. Each sample was divided into two equal aliquots to be used as a non-irradiated control sample and an irradiated sample. The irradiated aliquot was subjected to laser wavelengths of 405, 589, and 780 nm with different fluences of 36, 54, 72, and 90 J/cm2, at a fixed irradiance of 30 mW/cm2. A paired student t test was used to compare between non-irradiated and irradiated samples. The lymphocyte counts were measured using a computerized hematology analyzer and showed a significant (P < 0.02) maximum increase (1.6%) at a fluence of 72 J/cm2 when compared with non-irradiated samples. This increase in lymphocyte count upon irradiation was confirmed by flow cytometry. At a wavelength of 589 nm and fluence of 72 J/cm2, irradiation of whole blood samples showed a significant increase in CD45 lymphocytes and natural killer (NK) (CD16, CD56) cells, but no significant changes in CD3 T lymphocytes, T-suppressor (CD3, CD8) cells, T-helper (CD3, CD4) cells, and CD19 B lymphocytes when compared with their non-irradiated counterparts. Our results clearly demonstrate that NK cell count is altered by irradiation, which ultimately affects the whole lymphocyte count significantly.
- 3 January 2017
- Published by Springer Nature in Lasers in Medical Science
- Vol. 32 (2) , 405-411
Effects of low-level laser irradiation on human blood lymphocytes in vitro
Low-level laser irradiation (LLLI) has various effects on cultured human lymphocytes in vitro, but little is known about such effects in whole blood. This study investigated whether LLLI affected lymphocyte count in human whole blood in vitro. A total number of 130 blood samples were collected from apparently healthy adult patients through venipuncture into tubes containing EDTA. Each sample was divided into two equal aliquots to be used as a non-irradiated control sample and an irradiated sample. The irradiated aliquot was subjected to laser wavelengths of 405, 589, and 780 nm with different fluences of 36, 54, 72, and 90 J/cm2, at a fixed irradiance of 30 mW/cm2. A paired student t test was used to compare between non-irradiated and irradiated samples. The lymphocyte counts were measured using a computerized hematology analyzer and showed a significant (P < 0.02) maximum increase (1.6%) at a fluence of 72 J/cm2 when compared with non-irradiated samples. This increase in lymphocyte count upon irradiation was confirmed by flow cytometry. At a wavelength of 589 nm and fluence of 72 J/cm2, irradiation of whole blood samples showed a significant increase in CD45 lymphocytes and natural killer (NK) (CD16, CD56) cells, but no significant changes in CD3 T lymphocytes, T-suppressor (CD3, CD8) cells, T-helper (CD3, CD4) cells, and CD19 B lymphocytes when compared with their non-irradiated counterparts. Our results clearly demonstrate that NK cell count is altered by irradiation, which ultimately affects the whole lymphocyte count significantly.
- 1 June 2016
- Published by Springer Nature in Lasers in Medical Science
- Vol. 31 (6) , 1195-1201
Erythrocyte sedimentation rate of human blood exposed to low-level laser
This study is designed to investigate in vitro low-level laser (LLL) effects on rheological parameter, erythrocyte sedimentation rate (ESR), of human blood. The interaction mechanism between LLL radiation and blood is unclear. Therefore, research addresses the effects of LLL irradiation on human blood and this is essential to understanding how laser radiation interacts with biological cells and tissues. The blood samples were collected through venipuncture into EDTA-containing tubes as an anticoagulant. Each sample was divided into two equal aliquots to be used as a non-irradiated sample (control) and an irradiated sample. The aliquot was subjected to doses of 36, 54, 72 and 90 J/cm2 with wavelengths of 405, 589 and 780 nm, with a radiation source at a fixed power density of 30 mW/cm2. The ESR and red blood cell count and volume are measured after laser irradiation and compared with the non-irradiated samples. The maximum reduction in ESR is observed with radiation dose 72 J/cm2 delivered with a 405-nm wavelength laser beam. Moreover, no hemolysis is observed under these irradiation conditions. In a separate protocol, ESR of separated RBCs re-suspended in irradiated plasma (7.6 ± 2.3 mm/h) is found to be significantly lower (by 51 %) than their counterpart re-suspended in non-irradiated plasma (15.0 ± 3.7 mm/h). These results indicate that ESR reduction is mainly due to the effects of LLL on the plasma composition that ultimately affect whole blood ESR.
- 1 June 2016
- Published by Springer Nature in Lasers in Medical Science
- Vol. 31 (6) , 1195-1201
Erythrocyte sedimentation rate of human blood exposed to low-level laser
This study is designed to investigate in vitro low-level laser (LLL) effects on rheological parameter, erythrocyte sedimentation rate (ESR), of human blood. The interaction mechanism between LLL radiation and blood is unclear. Therefore, research addresses the effects of LLL irradiation on human blood and this is essential to understanding how laser radiation interacts with biological cells and tissues. The blood samples were collected through venipuncture into EDTA-containing tubes as an anticoagulant. Each sample was divided into two equal aliquots to be used as a non-irradiated sample (control) and an irradiated sample. The aliquot was subjected to doses of 36, 54, 72 and 90 J/cm2 with wavelengths of 405, 589 and 780 nm, with a radiation source at a fixed power density of 30 mW/cm2. The ESR and red blood cell count and volume are measured after laser irradiation and compared with the non-irradiated samples. The maximum reduction in ESR is observed with radiation dose 72 J/cm2 delivered with a 405-nm wavelength laser beam. Moreover, no hemolysis is observed under these irradiation conditions. In a separate protocol, ESR of separated RBCs re-suspended in irradiated plasma (7.6 ± 2.3 mm/h) is found to be significantly lower (by 51 %) than their counterpart re-suspended in non-irradiated plasma (15.0 ± 3.7 mm/h). These results indicate that ESR reduction is mainly due to the effects of LLL on the plasma composition that ultimately affect whole blood ESR.
- Open Access
- 1 May 2016
- Published by SAGE Publications in Photomedicine and Laser Surgery
- Vol. 34 (5) , 211-214
In Vitro Mean Red Blood Cell Volume Change Induced by Diode Pump Solid State Low-Level Laser of 405 nm
Objective: This study was conducted to investigate the effects of low-level laser (LLL) doses on human red blood cell volume. The effects of exposure to a diode pump solid state (DPSS) ( λ = 405 nm) laser were observed. Background data: The response of human blood to LLL irradiation gives important information about the mechanism of interaction of laser light with living organisms. Materials and methods Blood samples were collected into ethylenediaminetetraacetic acid (EDTA)-containing tubes, and each sample was divided into two equal aliquots, one to serve as control and the other for irradiation. The aliquot was subjected to laser irradiation for 20, 30, 40, or 50 min at a fixed power density of 0.03 W/cm 2 . Mean cell volume (MCV) and red blood cell (RBC) counts were measured immediately after irradiation using a computerized hemtoanalyzer. Results: Significant decrease in RBC volume ( p < 0.05, p < 0.0001, p < 0.0001, and p < 0.05, respectively) was induced with variation in laser doses.The highest response was observed with an exposure time of 40 min. This result was reproduced in RBCs suspended in a buffered NaCl solution. In contrast to this finding, laser-induced RBC volume change was completely abolished by suspending RBCs in a solution containing a higher concentration of EDTA. Conclusions: It was suggested that LLL can reduce RBC volume possibly because of the increased free intracellular Ca +2 concentrations, which activate Ca +2 -dependent K + channels with consequent K + ion efflux and cell shrinkage.
- 1 May 2016
- Published by SAGE Publications in Photomedicine and Laser Surgery
- Vol. 34 (5) , 211-214
Open AccessIn Vitro Mean Red Blood Cell Volume Change Induced by Diode Pump Solid State Low-Level Laser of 405 nm
Objective: This study was conducted to investigate the effects of low-level laser (LLL) doses on human red blood cell volume. The effects of exposure to a diode pump solid state (DPSS) ( λ = 405 nm) laser were observed. Background data: The response of human blood to LLL irradiation gives important information about the mechanism of interaction of laser light with living organisms. Materials and methods Blood samples were collected into ethylenediaminetetraacetic acid (EDTA)-containing tubes, and each sample was divided into two equal aliquots, one to serve as control and the other for irradiation. The aliquot was subjected to laser irradiation for 20, 30, 40, or 50 min at a fixed power density of 0.03 W/cm 2 . Mean cell volume (MCV) and red blood cell (RBC) counts were measured immediately after irradiation using a computerized hemtoanalyzer. Results: Significant decrease in RBC volume ( p < 0.05, p < 0.0001, p < 0.0001, and p < 0.05, respectively) was induced with variation in laser doses.The highest response was observed with an exposure time of 40 min. This result was reproduced in RBCs suspended in a buffered NaCl solution. In contrast to this finding, laser-induced RBC volume change was completely abolished by suspending RBCs in a solution containing a higher concentration of EDTA. Conclusions: It was suggested that LLL can reduce RBC volume possibly because of the increased free intracellular Ca +2 concentrations, which activate Ca +2 -dependent K + channels with consequent K + ion efflux and cell shrinkage.