Abdel Nasser Mabrouk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdel Nasser Mabrouk has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Adel O. Sharif
Qatar Energy and Environment Research Institute, The Qatar Foundation, Doha, Qatar, Tel. +974 55241752
2 shared publications - Ashraf S. Hassan
Qatar Environment and Energy Research Institute, HBKU, Qatar Foundation, P.O. Box 5825, Doha, Qatar, Tel. +974 4454 2892
2 shared publications - Hassan Abdulrahim
Qatar Environment and Energy Research Institute, Qatar Foundation, P.O. Box 5825, Doha, Qatar
2 shared publications - Mohamed Ali Darwish
Qatar Environment and Energy Research Institute, Qatar Foundation, P.O. Box 5825, Doha, Qatar
2 shared publications
Latest Publications
- Open Access
- 1 July 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (31) , 14336-14346
Viability of integrating forward osmosis (FO) as pretreatment for existing MSF desalting unit
The feed to all Recirculation-multi-stage flash (R-MSF) desalting units in Qatar is pretreated with high temperature additive, which limits its top brine temperature (TBT) to 110°C. The daily capacity of these R-MSF units is about one Million cubic meters (Mm3/d). These units should continue their operation through their life time, (20–30 years). The capacity and performance of these units can be enhanced if Forward osmosis (FO) membrane system is used as pretreatment. The FO membranes can remove the scale constituents in the feed water and allows rising the TBT up to 135°C, and thus increases the capacity of these units. The viability of using FO as feed water pretreatment to an existing operating R-MSF unit is discussed in this paper. A suggested arrangement to use FO as MSF feed pretreatment is presented. Part of the cooling seawater leaving the heat rejection is directed to the FO pretreatment unit as feed solution (FS). The flashing brine leaving the last stage with the maximum brine salt concentration (about 1.5 times of the seawater feed) is directed to the FO unit as draw solution (DS) that absorbs an amount permeate water (D) from the FS while the Ca2+, , Mg2+, and are rejected. The diluted DS enters the last stage condenser of the heat recovery section. This arrangement allows to increase the TBT and thus the unit distillate capacity. The potential of calcium sulfate deposite index inside MSF condenser tubes is calculated at different TBTs and different FO recovery ratio. The calculations show that Skillman index in reference MSF (operates at TBT = 110°C) plant is greater than one which indicates the potential of scale deposit formation; however, antiscalant is used to disperse the crystalized scale. The simulation results showed that the potential of scale deposit is decreased as the FO recovery ratio increases due to the increase in divalent ions removal. The MSF can operate at TBT = 135°C safely without calcium sulfate scale at FO recovery ratio of 40%. On the other hand, the increase in the FO recovery ratio, will reduce the osmotic pressure difference across the membrane which requires higher membrane surface area. The impact of feed salinity is investigated, and the results showed that lowering the feed salinity gives better performance of FO unit. The cost of the FO membranes is a major factor in applying the suggested use of the FO as pretreatment for the R-MSF unit. The decision to apply this method depends on the availability and reasonable cost of the FO membranes.
- 1 July 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (31) , 14336-14346
Open AccessViability of integrating forward osmosis (FO) as pretreatment for existing MSF desalting unit
The feed to all Recirculation-multi-stage flash (R-MSF) desalting units in Qatar is pretreated with high temperature additive, which limits its top brine temperature (TBT) to 110°C. The daily capacity of these R-MSF units is about one Million cubic meters (Mm3/d). These units should continue their operation through their life time, (20–30 years). The capacity and performance of these units can be enhanced if Forward osmosis (FO) membrane system is used as pretreatment. The FO membranes can remove the scale constituents in the feed water and allows rising the TBT up to 135°C, and thus increases the capacity of these units. The viability of using FO as feed water pretreatment to an existing operating R-MSF unit is discussed in this paper. A suggested arrangement to use FO as MSF feed pretreatment is presented. Part of the cooling seawater leaving the heat rejection is directed to the FO pretreatment unit as feed solution (FS). The flashing brine leaving the last stage with the maximum brine salt concentration (about 1.5 times of the seawater feed) is directed to the FO unit as draw solution (DS) that absorbs an amount permeate water (D) from the FS while the Ca2+, , Mg2+, and are rejected. The diluted DS enters the last stage condenser of the heat recovery section. This arrangement allows to increase the TBT and thus the unit distillate capacity. The potential of calcium sulfate deposite index inside MSF condenser tubes is calculated at different TBTs and different FO recovery ratio. The calculations show that Skillman index in reference MSF (operates at TBT = 110°C) plant is greater than one which indicates the potential of scale deposit formation; however, antiscalant is used to disperse the crystalized scale. The simulation results showed that the potential of scale deposit is decreased as the FO recovery ratio increases due to the increase in divalent ions removal. The MSF can operate at TBT = 135°C safely without calcium sulfate scale at FO recovery ratio of 40%. On the other hand, the increase in the FO recovery ratio, will reduce the osmotic pressure difference across the membrane which requires higher membrane surface area. The impact of feed salinity is investigated, and the results showed that lowering the feed salinity gives better performance of FO unit. The cost of the FO membranes is a major factor in applying the suggested use of the FO as pretreatment for the R-MSF unit. The decision to apply this method depends on the availability and reasonable cost of the FO membranes.
- Open Access
- 1 February 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (10) , 4269-4295
The forward osmosis and desalination
Forward osmosis (FO) has emerged as a method for desalting saline water and power production. It utilizes a chemical potential difference, or a salinity gradient to permeate fresh water through membranes. This paper investigates the feasibility of using the FO process for seawater (SW) desalination in terms of consumed energy, capital costs, water recovery, operation & maintenance, water quality, and the final product water cost. The study covers FO by itself, and when combines with other desalting systems such as reverse osmosis, multi stage flash (MSF), and multi effect distillation as pretreatment method. This paper reviews first the principles of fluid and solutes flow in the FO membranes, concentration polarization, the difference between the FO, pressure retarded osmosis processes, draw solutions, and the solutes involved in these draw solutions. Then, the main characteristics of the FO membranes and their commercial availability are presented. Previous experimental work and a commercial plant using FO for desalination are also given. The use of FO as pretreatment for other desalting methods is presented in light of two proposed research projects. The first research project proposes utilizing FO as pretreatment for processing treated wastewater and SW in one system. The second project utilizes FO as pretreatment for a once-through MSF desalting method. The analysis proved energy reduction in the energy consumption of both desalting systems by more than 50 and 18%, respectively.
- 1 February 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (10) , 4269-4295
Open AccessThe forward osmosis and desalination
Forward osmosis (FO) has emerged as a method for desalting saline water and power production. It utilizes a chemical potential difference, or a salinity gradient to permeate fresh water through membranes. This paper investigates the feasibility of using the FO process for seawater (SW) desalination in terms of consumed energy, capital costs, water recovery, operation & maintenance, water quality, and the final product water cost. The study covers FO by itself, and when combines with other desalting systems such as reverse osmosis, multi stage flash (MSF), and multi effect distillation as pretreatment method. This paper reviews first the principles of fluid and solutes flow in the FO membranes, concentration polarization, the difference between the FO, pressure retarded osmosis processes, draw solutions, and the solutes involved in these draw solutions. Then, the main characteristics of the FO membranes and their commercial availability are presented. Previous experimental work and a commercial plant using FO for desalination are also given. The use of FO as pretreatment for other desalting methods is presented in light of two proposed research projects. The first research project proposes utilizing FO as pretreatment for processing treated wastewater and SW in one system. The second project utilizes FO as pretreatment for a once-through MSF desalting method. The analysis proved energy reduction in the energy consumption of both desalting systems by more than 50 and 18%, respectively.