Yuanfei Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuanfei Zhu has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Ming Yang
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
9 shared publications Ming Yang
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
3 shared publicationsJunwen Yu
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications- Shangting Wang
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
2 shared publications - Tianyue Yang
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
2 shared publications - Tianyue Yang
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications
Latest Publications
- 21 July 2026
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 49 (10) , 715-724
Design and in vitro evaluation of a parallel gas-exchange chambers oxygenator with reduced hemolysis and pressure drop
Background: Hemolytic complications remain a major limitation of membrane oxygenators in clinical support. Compared with human lungs, most commercial oxygenators generate substantial pressure drops and high shear stress, increasing the risks of hemolysis. Therefore, we aimed to develop a membrane oxygenator that reduces pressure drop and shear-induced blood damage while maintaining the oxygen transfer rate. Methods: We propose a parallel gas exchange chamber (PGEC) oxygenator in which the blood flow is divided into two identical gas exchange chambers connected in parallel. The computational fluid dynamics (CFD) model was used to design and analyze the oxygenators. The oxygen transfer rate and blood damage parameters of the PGEC and conventional oxygenator were evaluated by in vitro tests at a blood flow rate of 900 mL/min. Oxygen transfer rate, pressure drop, plasma free hemoglobin concentration, and thrombin–antithrombin complex (TAT) concentration were measured ( n = 3). Results: Under the present identical in vitro test conditions, the oxygen transfer rate of the PGEC oxygenator (18.15 ± 0.69 mL/min) was not significantly different from that of the conventional oxygenator (17.73 ± 0.73 mL/min). The PGEC design reduced pressure drop by 42% and decreased the normalized index of hemolysis (NIH) by 63% ( p = 0.028), while TAT concentrations did not differ significantly between the two circuits. Conclusions: The parallel design of the gas exchange chambers decreases blood velocity in the hollow fiber membrane region, thereby lowering pressure drop and hemolysis while maintaining oxygen transfer rate under the tested conditions.
- 21 July 2026
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 49 (10) , 715-724
Design and in vitro evaluation of a parallel gas-exchange chambers oxygenator with reduced hemolysis and pressure drop
Background: Hemolytic complications remain a major limitation of membrane oxygenators in clinical support. Compared with human lungs, most commercial oxygenators generate substantial pressure drops and high shear stress, increasing the risks of hemolysis. Therefore, we aimed to develop a membrane oxygenator that reduces pressure drop and shear-induced blood damage while maintaining the oxygen transfer rate. Methods: We propose a parallel gas exchange chamber (PGEC) oxygenator in which the blood flow is divided into two identical gas exchange chambers connected in parallel. The computational fluid dynamics (CFD) model was used to design and analyze the oxygenators. The oxygen transfer rate and blood damage parameters of the PGEC and conventional oxygenator were evaluated by in vitro tests at a blood flow rate of 900 mL/min. Oxygen transfer rate, pressure drop, plasma free hemoglobin concentration, and thrombin–antithrombin complex (TAT) concentration were measured ( n = 3). Results: Under the present identical in vitro test conditions, the oxygen transfer rate of the PGEC oxygenator (18.15 ± 0.69 mL/min) was not significantly different from that of the conventional oxygenator (17.73 ± 0.73 mL/min). The PGEC design reduced pressure drop by 42% and decreased the normalized index of hemolysis (NIH) by 63% ( p = 0.028), while TAT concentrations did not differ significantly between the two circuits. Conclusions: The parallel design of the gas exchange chambers decreases blood velocity in the hollow fiber membrane region, thereby lowering pressure drop and hemolysis while maintaining oxygen transfer rate under the tested conditions.
- Open Access
- 31 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 438
Design of a Motor-Torsion Driven 3D-Printed Left Ventricular Mock Circulation System and Hemocompatibility Assessment
In vitro testing of ventricular assist devices, constructing a mock circulation system that reproduces physiological cardiac function, is critical. However, current ventricular simulators often lack biomimetic fidelity and may introduce hemolysis and coagulation risks during prolonged operation, affecting hemocompatibility assessment. This study proposes a motor-driven torsional 3D-printed left ventricular simulator to reconstruct the hemodynamics of severe heart failure and related pathological conditions. The system integrates a 3D-printed elastic ventricular model with programmable torsional actuation, allowing the simulation of various cardiac conditions by adjusting the motor torsion angle and rotational speed, peripheral resistance and compliance. Fresh porcine blood was circulated for 4 h in a closed-loop system, with periodic measurements of plasma-free hemoglobin (PfHb), thrombin–antithrombin complex (TAT), and P-selectin. The results show that the system successfully reproduces typical hemodynamic features of severe heart failure, while hemolysis and coagulation markers remain low. After 4 h, PfHb was below 20 mg/dL, with no significant platelet activation or thrombosis. This study demonstrates that the proposed system enhances biomimicry while maintaining excellent hemocompatibility, offering a reliable platform for in vitro performance and safety evaluation of ventricular assist devices.
- 31 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 438
Open AccessDesign of a Motor-Torsion Driven 3D-Printed Left Ventricular Mock Circulation System and Hemocompatibility Assessment
In vitro testing of ventricular assist devices, constructing a mock circulation system that reproduces physiological cardiac function, is critical. However, current ventricular simulators often lack biomimetic fidelity and may introduce hemolysis and coagulation risks during prolonged operation, affecting hemocompatibility assessment. This study proposes a motor-driven torsional 3D-printed left ventricular simulator to reconstruct the hemodynamics of severe heart failure and related pathological conditions. The system integrates a 3D-printed elastic ventricular model with programmable torsional actuation, allowing the simulation of various cardiac conditions by adjusting the motor torsion angle and rotational speed, peripheral resistance and compliance. Fresh porcine blood was circulated for 4 h in a closed-loop system, with periodic measurements of plasma-free hemoglobin (PfHb), thrombin–antithrombin complex (TAT), and P-selectin. The results show that the system successfully reproduces typical hemodynamic features of severe heart failure, while hemolysis and coagulation markers remain low. After 4 h, PfHb was below 20 mg/dL, with no significant platelet activation or thrombosis. This study demonstrates that the proposed system enhances biomimicry while maintaining excellent hemocompatibility, offering a reliable platform for in vitro performance and safety evaluation of ventricular assist devices.
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 1879-1890
An Ultra-Fast Transient Performance Tracking Scheme for High Power Piezoelectric Transducers
The vibration transient performance is critical for dynamic capability and operational stability of high power piezoelectric transducers (HPPTs). However, most of previous researches focus on the shut-down transient, there is little research on optimizing the start-up transient. This article presents an ultrafast transient tracking scheme for the start-up vibration response of HPPTs. The transient characteristics of the HPPT with an electrical matching are firstly derived. Then, to optimize the start-up transient without resistive loss, an equivalent virtual resistor is introduced by an inverter combined with a transformer and LC matching driving scheme. Furthermore, to improve the phase-frequency transient during the initial start-up transient phase, the susceptance-based frequency tracking control scheme is proposed. Experimental results demonstrate that the proposed scheme not only can break through the limitation of the transient time constant τ of the HPPT to reduce both the response time and tracking time, but also has a higher robustness under different start-up frequencies and load conditions compared to traditional phase feedback method. In an ultrasonic cutting system with τ of 100.8 ms, the proposed scheme achieves the dynamic control performance with a frequency tracking time of 5.5 ms (0.055τ) and a vibration response time of 15.0 ms (0.15τ).
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 1879-1890
An Ultra-Fast Transient Performance Tracking Scheme for High Power Piezoelectric Transducers
The vibration transient performance is critical for dynamic capability and operational stability of high power piezoelectric transducers (HPPTs). However, most of previous researches focus on the shut-down transient, there is little research on optimizing the start-up transient. This article presents an ultrafast transient tracking scheme for the start-up vibration response of HPPTs. The transient characteristics of the HPPT with an electrical matching are firstly derived. Then, to optimize the start-up transient without resistive loss, an equivalent virtual resistor is introduced by an inverter combined with a transformer and LC matching driving scheme. Furthermore, to improve the phase-frequency transient during the initial start-up transient phase, the susceptance-based frequency tracking control scheme is proposed. Experimental results demonstrate that the proposed scheme not only can break through the limitation of the transient time constant τ of the HPPT to reduce both the response time and tracking time, but also has a higher robustness under different start-up frequencies and load conditions compared to traditional phase feedback method. In an ultrasonic cutting system with τ of 100.8 ms, the proposed scheme achieves the dynamic control performance with a frequency tracking time of 5.5 ms (0.055τ) and a vibration response time of 15.0 ms (0.15τ).
- 12 July 2025
- Published by Wiley in Artificial Organs
- Vol. 49 (11) , 1642-1651
The Impact of Transient Control Performance of Pulsatile Flow on Hemolysis and Coagulation in Ex Vivo Heart Perfusion
Background: Ex vivo heart perfusion (EVHP) is a promising approach for preserving donor hearts in a near‐physiological state. However, the perfusion pressure and flow require adjustment to meet the requirements of aerobic metabolism, which may cause hemolysis and coagulation, consequently impairing myocardial function. The aim of this study is to investigate the impact of transient control performance of pulsatile flow on hemolysis and coagulation in EVHP. Methods: Fresh porcine blood was circulated for 4 h in a mock loop equipped with a pulsatile pump and a self‐designed compliant chamber, operating under conditions of a mean flow rate of 1 L/min and a mean pressure of 75 mmHg. Two typical proportional‐integral‐derivative (PID) control responses (underdamped response and overdamped response) were implemented to compare the impact of transient performance on hemolysis and coagulation. Blood samples were collected from the in vitro loop and analyzed for plasma free hemoglobin (PfHb), thrombin‐antithrombin complex (TAT) and P‐selectin levels. Results: The experimental results demonstrated that the transient control performance of pulsatile flow had a significant impact on hemolysis and coagulation as circulation time increased. Compared to the overdamped response, the underdamped response resulted in more hemolysis and a higher risk of thrombosis. However, both the overdamped response and the underdamped response exhibited comparable levels of platelet activation. Conclusion: During the control process of EVHP, frequent adjustments of perfusion pressure and flow should be minimized. Additionally, oscillations and overshoots in transient responses should be avoided to reduce hemolysis and thrombosis.
- 12 July 2025
- Published by Wiley in Artificial Organs
- Vol. 49 (11) , 1642-1651
The Impact of Transient Control Performance of Pulsatile Flow on Hemolysis and Coagulation in Ex Vivo Heart Perfusion
Background: Ex vivo heart perfusion (EVHP) is a promising approach for preserving donor hearts in a near‐physiological state. However, the perfusion pressure and flow require adjustment to meet the requirements of aerobic metabolism, which may cause hemolysis and coagulation, consequently impairing myocardial function. The aim of this study is to investigate the impact of transient control performance of pulsatile flow on hemolysis and coagulation in EVHP. Methods: Fresh porcine blood was circulated for 4 h in a mock loop equipped with a pulsatile pump and a self‐designed compliant chamber, operating under conditions of a mean flow rate of 1 L/min and a mean pressure of 75 mmHg. Two typical proportional‐integral‐derivative (PID) control responses (underdamped response and overdamped response) were implemented to compare the impact of transient performance on hemolysis and coagulation. Blood samples were collected from the in vitro loop and analyzed for plasma free hemoglobin (PfHb), thrombin‐antithrombin complex (TAT) and P‐selectin levels. Results: The experimental results demonstrated that the transient control performance of pulsatile flow had a significant impact on hemolysis and coagulation as circulation time increased. Compared to the overdamped response, the underdamped response resulted in more hemolysis and a higher risk of thrombosis. However, both the overdamped response and the underdamped response exhibited comparable levels of platelet activation. Conclusion: During the control process of EVHP, frequent adjustments of perfusion pressure and flow should be minimized. Additionally, oscillations and overshoots in transient responses should be avoided to reduce hemolysis and thrombosis.
- 25 July 2024
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 62 (12) , 3875-3885
Hemodynamic effects of pulsatile frequency of right ventricular assist device (RVAD) on pulmonary perfusion: a simulation study
- 25 July 2024
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 62 (12) , 3875-3885
Hemodynamic effects of pulsatile frequency of right ventricular assist device (RVAD) on pulmonary perfusion: a simulation study
- Open Access
- 22 July 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (7) , 934
Impact of Impeller Speed Adjustment Interval on Hemolysis Performance of an Intravascular Micro-Axial Blood Pump
Background: In recent years, intravascular micro-axial blood pumps have been increasingly used in the treatment of patients with cardiogenic shock. The flow rate of such blood pumps requires adjustment based on the patient’s physiological condition. Compared to a stable flow state with fixed rotation speed, adjusting the speed of blood pump impeller to alter flow rate may lead to additional hemolysis. This study aimed at elucidating the relationship between adjusting interval of a blood pump’s impeller speed and the hemolysis index. Methods: By comparing simulation results with P-Q characteristic curves of the blood pump measured by experiments, the accuracy of the blood pump flow field simulation model was confirmed. In this study, a drainage tube was employed as the device analogous to an intravascular micro-axial blood pump for achieving similar shear stress levels and residence times. The hemolysis finite element prediction method based on a power-law model was validated through hemolysis testing of porcine blood flow through the drainage tube. The validated models were subsequently utilized to investigate the impact of impeller speed adjusting intervals on hemolysis in the blood pump. Results: Compared to steady flow, the results demonstrate that the hemolysis index increased to 6.3% when changing the blood pump flow rate from 2 L/min to 2.5 L/min by adjusting the impeller speed within 0.072 s. Conclusions: An adjustment time of impeller speed longer than 0.072 s can avoid extra hemolysis when adjusting the intravascular micro-axial blood pump flow rate from 2 L/min to 2.5 L/min.
- 22 July 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (7) , 934
Open AccessImpact of Impeller Speed Adjustment Interval on Hemolysis Performance of an Intravascular Micro-Axial Blood Pump
Background: In recent years, intravascular micro-axial blood pumps have been increasingly used in the treatment of patients with cardiogenic shock. The flow rate of such blood pumps requires adjustment based on the patient’s physiological condition. Compared to a stable flow state with fixed rotation speed, adjusting the speed of blood pump impeller to alter flow rate may lead to additional hemolysis. This study aimed at elucidating the relationship between adjusting interval of a blood pump’s impeller speed and the hemolysis index. Methods: By comparing simulation results with P-Q characteristic curves of the blood pump measured by experiments, the accuracy of the blood pump flow field simulation model was confirmed. In this study, a drainage tube was employed as the device analogous to an intravascular micro-axial blood pump for achieving similar shear stress levels and residence times. The hemolysis finite element prediction method based on a power-law model was validated through hemolysis testing of porcine blood flow through the drainage tube. The validated models were subsequently utilized to investigate the impact of impeller speed adjusting intervals on hemolysis in the blood pump. Results: Compared to steady flow, the results demonstrate that the hemolysis index increased to 6.3% when changing the blood pump flow rate from 2 L/min to 2.5 L/min by adjusting the impeller speed within 0.072 s. Conclusions: An adjustment time of impeller speed longer than 0.072 s can avoid extra hemolysis when adjusting the intravascular micro-axial blood pump flow rate from 2 L/min to 2.5 L/min.
- 1 April 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (4)
A wide drive frequency matching method for harmonic suppression and voltage stabilization of ultrasonic motors
To reduce harmonic components, balance system impedance, and stabilize driving voltage, an additional matching circuit is required for ultrasonic motors (USMs) driver. However, the performance of inductor or capacitor matching can be seriously weakened with changes in driving frequency. Therefore, this paper presents a simple and effective LC matching method against driving frequency adjustment for USMs. First, the driving scheme of the USM is proposed and the electromechanical coupling model is analyzed. Subsequently, the output characteristics of the full-bridge inverter are derived theoretically when the driving frequency deviates from the mechanical resonant frequency. Then, the impedance circular transform method is proposed, which can intuitively analyze the effect of matching parameters on the voltage amplitude. A matching objective function is established that can consider both the voltage stabilization and harmonic suppression. The matching parameters are solved using random weight particle swarm optimization. Simulations and experiments demonstrate that within the operating frequency of the USM, the proposed matching method can effectively prevent overvoltage and suppress harmonic components. Furthermore, compared with the existing resonant matching method, the proposed matching method can realize more stable driving capability at different frequencies. The proposed method could be useful for USMs’ variable-frequency driver design.
- 1 April 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (4)
A wide drive frequency matching method for harmonic suppression and voltage stabilization of ultrasonic motors
To reduce harmonic components, balance system impedance, and stabilize driving voltage, an additional matching circuit is required for ultrasonic motors (USMs) driver. However, the performance of inductor or capacitor matching can be seriously weakened with changes in driving frequency. Therefore, this paper presents a simple and effective LC matching method against driving frequency adjustment for USMs. First, the driving scheme of the USM is proposed and the electromechanical coupling model is analyzed. Subsequently, the output characteristics of the full-bridge inverter are derived theoretically when the driving frequency deviates from the mechanical resonant frequency. Then, the impedance circular transform method is proposed, which can intuitively analyze the effect of matching parameters on the voltage amplitude. A matching objective function is established that can consider both the voltage stabilization and harmonic suppression. The matching parameters are solved using random weight particle swarm optimization. Simulations and experiments demonstrate that within the operating frequency of the USM, the proposed matching method can effectively prevent overvoltage and suppress harmonic components. Furthermore, compared with the existing resonant matching method, the proposed matching method can realize more stable driving capability at different frequencies. The proposed method could be useful for USMs’ variable-frequency driver design.
- Open Access
- 24 November 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (12) , 2147
Push–Pull Inverter Using Amplitude Control and Frequency Tracking for Piezoelectric Transducers
Frequency tracking and amplitude control are essential for piezoelectric transducers. Frequency tracking ensures the piezoelectric transducer operates at the resonant frequency for maximum power output, and amplitude control regulates the mechanical motion of the output. This paper presents a novel driver based on a push–pull inverter for piezoelectric transducers. The proposed driver realizes the frequency tracking and amplitude control scheme by a voltage sensing bridge in the case of transformer secondary matching, guaranteeing automatic frequency tracking and precise mechanical functions regardless of environmental and load variations. The proposed scheme is verified by the ultrasonic scalpel and the ultrasonic motor (USM). The experimental results show that this scheme reduces the build-up time from 10 ms to 3 ms and loaded frequency variations from 250 Hz to 200 Hz. In addition, the amplitude control performance was further observed on USM for various loads. The overshoot is less than 5.4% under different load torques. Therefore, the proposed scheme improves the load adaptability and stability of piezoelectric transducers and promotes the application of piezoelectric transducers under various conditions.
- 24 November 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (12) , 2147
Open AccessPush–Pull Inverter Using Amplitude Control and Frequency Tracking for Piezoelectric Transducers
Frequency tracking and amplitude control are essential for piezoelectric transducers. Frequency tracking ensures the piezoelectric transducer operates at the resonant frequency for maximum power output, and amplitude control regulates the mechanical motion of the output. This paper presents a novel driver based on a push–pull inverter for piezoelectric transducers. The proposed driver realizes the frequency tracking and amplitude control scheme by a voltage sensing bridge in the case of transformer secondary matching, guaranteeing automatic frequency tracking and precise mechanical functions regardless of environmental and load variations. The proposed scheme is verified by the ultrasonic scalpel and the ultrasonic motor (USM). The experimental results show that this scheme reduces the build-up time from 10 ms to 3 ms and loaded frequency variations from 250 Hz to 200 Hz. In addition, the amplitude control performance was further observed on USM for various loads. The overshoot is less than 5.4% under different load torques. Therefore, the proposed scheme improves the load adaptability and stability of piezoelectric transducers and promotes the application of piezoelectric transducers under various conditions.
- Open Access
Two-Phase Stator Vibration Amplitude Compensation of Traveling-Wave Ultrasonic Motor
The consistency of the two-phase mode responses is essential to ensure the mechanical performance and stability of traveling-wave ultrasonic motors. Due to the asymmetry of the stator, inevitable manufacturing errors, or imbalance of the excitation voltages, the amplitudes of the two-phase standing waves cannot be exactly the same, resulting in unstable operating of USM. To improve the stability of the motor and decrease the velocity fluctuation, a closed-loop velocity control scheme considering two-phase consistency compensation based on the vibration amplitude of the stator is proposed. This scheme is implemented under the framework of the stator vibration amplitude-based velocity control and parallel resonance frequency tracking (VCBVF). Based on the relationship between the velocity and stator vibration amplitude (SVA), two-phase excitation signals are adjusted individually and simultaneously. Compared with the single-phase feedback VCBVF control scheme, experimental results show that the proposed scheme can reduce the overshoot from 17.50% to 6.90% and velocity fluctuations from 7.69 rpm to 2.40 rpm, under different load torques. The proposed scheme can compensate for the two-phase electrical inconsistency and improve the velocity stability and output power of motor operation under various conditions.
Open AccessTwo-Phase Stator Vibration Amplitude Compensation of Traveling-Wave Ultrasonic Motor
The consistency of the two-phase mode responses is essential to ensure the mechanical performance and stability of traveling-wave ultrasonic motors. Due to the asymmetry of the stator, inevitable manufacturing errors, or imbalance of the excitation voltages, the amplitudes of the two-phase standing waves cannot be exactly the same, resulting in unstable operating of USM. To improve the stability of the motor and decrease the velocity fluctuation, a closed-loop velocity control scheme considering two-phase consistency compensation based on the vibration amplitude of the stator is proposed. This scheme is implemented under the framework of the stator vibration amplitude-based velocity control and parallel resonance frequency tracking (VCBVF). Based on the relationship between the velocity and stator vibration amplitude (SVA), two-phase excitation signals are adjusted individually and simultaneously. Compared with the single-phase feedback VCBVF control scheme, experimental results show that the proposed scheme can reduce the overshoot from 17.50% to 6.90% and velocity fluctuations from 7.69 rpm to 2.40 rpm, under different load torques. The proposed scheme can compensate for the two-phase electrical inconsistency and improve the velocity stability and output power of motor operation under various conditions.
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (11) , 3415-3422
Super-Resolution Velocity Reconstruction and Control of Ultrasonic Motors
Accurate and fast velocity feedback signal is essential for the velocity control of ultrasonic motors (USMs). However, the low operating velocity of USMs results in a long velocity detection dead time (VDDT) of incremental encoders, which seriously restricts the dynamic control performance of USMs. Therefore, this article presents a super-resolution velocity control (SRVC) scheme based on the velocity reconstruction for the USM. First, the mathematical model of the USM is derived from the mechanical characteristics and the electromechanical coupling characteristics. Then, the velocity reconstruction method is proposed by combining the model estimated velocity and the encoder measured velocity. The closed-loop control scheme using the reconstructed velocity is implemented by a self-designed driving circuit. Experimental results show the velocity reconstruction method not only can break through the limitation of the encoder resolution to reduce the VDDT but also has a high-velocity accuracy. Furthermore, compared with the existing encoder-based control scheme, the proposed SRVC scheme has a faster velocity response under different loads.
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (11) , 3415-3422
Super-Resolution Velocity Reconstruction and Control of Ultrasonic Motors
Accurate and fast velocity feedback signal is essential for the velocity control of ultrasonic motors (USMs). However, the low operating velocity of USMs results in a long velocity detection dead time (VDDT) of incremental encoders, which seriously restricts the dynamic control performance of USMs. Therefore, this article presents a super-resolution velocity control (SRVC) scheme based on the velocity reconstruction for the USM. First, the mathematical model of the USM is derived from the mechanical characteristics and the electromechanical coupling characteristics. Then, the velocity reconstruction method is proposed by combining the model estimated velocity and the encoder measured velocity. The closed-loop control scheme using the reconstructed velocity is implemented by a self-designed driving circuit. Experimental results show the velocity reconstruction method not only can break through the limitation of the encoder resolution to reduce the VDDT but also has a high-velocity accuracy. Furthermore, compared with the existing encoder-based control scheme, the proposed SRVC scheme has a faster velocity response under different loads.