MMMarcelo Ferraz Mesquita

Marcelo Ferraz Mesquita

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marcelo Ferraz Mesquita has a total of 84 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Precision in mandibular implant overdentures

    by Ana Paula Guidi Schmidt Hidalgo, Thaís Barbin, Leonardo Mendes Ribeiro Machado, Marcelo Ferraz Mesquita, Guilherme Almeida Borges

    Aim: Selection of prosthetic attachment height and implant number can influence the supporting structures of implant mandibular overdentures (IMOs), including peri-implant tissue and prosthetic components. This study evaluated the biomechanical effects of single IMO (SIMO) or two IMO (TIMO) systems with different stud transmucosal heights (2, 3, or 4 mm) on cortical bone, mucosal tissue, implants, and prosthetic elements. Methods: Twelve three-dimensional finite element models were created using McNeel Rhinoceros 3D v7.0®, representing scenarios with 2 mm (SIMO-2mm, TIMO-2mm), 3 mm (SIMO-3mm, TIMO-3mm), and 4 mm (SIMO-4mm, TIMO-4mm) heights. Simulations included 100 N oblique loading (30º) on lower central incisors and 150 N axial loading on the first molars. Von Mises stress (implant, housing, stud), maximum and minimal principal stress (bone, tissue, prosthesis, nylon), and displacement were analyzed through numerical data and color-coded images. Results: Oblique loading resulted in higher stress, particularly in SIMO-4mm and TIMO-4mm. Nylon inserts in SIMO configurations experienced high compressive stress, especially in SIMO-4mm. TIMO configurations under oblique loading caused critical stress in peri-implant bone. Prosthetic tensile stress and displacement were greatest in SIMO-4mm under anterior loading. High transmucosal heights increased stress on housing, attachment, and prosthesis, particularly in systems with thin soft tissue. Conclusion: SIMO and TIMO rehabilitations under oblique loading showed high stress in ductile structures, with significant implications for SIMO-4mm due to stress concentration in nylon, prosthesis base, and displacement. Elevated transmucosal heights should be used cautiously in cases of limited soft tissue thickness.

  • Open Access

    A novel technique for in vitro assessment of marginal fit in full-arch implant-supported prostheses

    by Thaís Barbin, Letícia Del Rio Silva, Daniele Valente Velôso, Anna Gabriella Camacho Presotto, Valentim Adelino Ricardo Barão, Marcelo Ferraz Mesquita, Guilherme Almeida Borges

    This study proposes a novel no-screw (NS) technique for assessing marginal fit, comparing its performance with the established single-screw (SS) protocol, also known as the Sheffield test. Four implants and their corresponding abutments were placed in prototyped maxillae. Screw-retained implant-supported frameworks were fabricated from cobalt–chromium (Co-Cr) and titanium alloy containing 6% aluminum and 4% vanadium (Ti) using computer-aided design-computer-aided manufacturing (CAD-CAM) milling technology. Marginal fits were measured using the SS and NS techniques (n = 5 per group). For the NS technique, each framework was placed in the prototyped maxillae and fixed to the mesial side of the four abutments using a liquid-powder technique without screws. Both techniques (SS and NS) were performed 3 times for each framework, and the mean value was calculated. Data were analyzed using two-way analysis of variance (ANOVA) followed by Bonferroni’s test. There was no interaction between technique and material (p = 0.321). However, pooling techniques and materials significantly influenced fit values (p < 0.01). Fit values were lower for the NS technique (41.41 ± 12.46 µm) than for the SS test (97.63 ± 32.13 µm), regardless of material (p = 0.003). Lower fit values were observed for Ti (54.69 ± 34.36 µm) than for Co-Cr (84.35 ± 35.70 µm), regardless of the technique used (p = 0.01). The NS technique yielded lower vertical marginal fit values than the SS technique, regardless of the framework material, suggesting that it may reflect the marginal fit of the framework in the absence of screw-induced preload.

  • Unfolding the applicability of 3D-printed Ti-6Al-4V alloy and platinum-based film deposition for dental prostheses applications

    by Daniele Valente Velôso, Thaís Barbin, Richard Landers, André Luiz Jardini, Marcelo Ferraz Mesquita, Guilherme Almeida Borges


  • Additive manufacturing of CAD-CAM complete arch fixed implant restorations supported by six implants: Prosthetic screw stability and marginal precision under masticatory simulation

    by Daniele Valente Velôso, Thaís Barbin, Letícia Del Rio Silva, Valentim A.R. Barão, Marcelo Ferraz Mesquita, Guilherme Almeida Borges


  • Prognosis of removable complete dentures considering the level of mandibular residual ridge resorption: a systematic review and meta-analysis

    by Guilherme Almeida Borges, Maria Helena Rossy Borges, Caroline Dini, Raissa Micaella Marcello-Machado, Valentim A. R. Barão, Marcelo Ferraz Mesquita

    Objective To compare clinical outcomes in atrophic (AM) and non-atrophic (NAM) mandibles of edentulous patients rehabilitated with mandibular removable complete dentures (CD) or implant mandibular overdentures (IMO). Materials and methods Non-randomized clinical studies were searched in 8 databases. Articles were assessed by the risk of bias in non-randomized studies of interventions. Datasets for CDs comparing AM and NAM were plotted [masticatory function, maximum occlusal biting force (MOBF), oral health-related quality of life (OHRQoL)]. Residual ridge (AM and NAM) data (masticatory function, OHRQoL, implant survival, marginal bone loss, and maintenance events) in IMO were also combined. Results 23 studies were included. Only 1 was classified as low risk of bias. Superior masticatory performance was observed in the NAM group rehabilitated with CD (P <.001). NAM group rehabilitated with CD exhibited increased MOBF (P <.05). Once patients were treated with IMO, improvements were observed in swallowing threshold (number of cycles and time) in the NAM group (P <.05). Comparable results of OHRQoL were noted for both groups (AM and NAM) and rehabilitations (CD and IMO). Similar peri-implant outcomes were displayed for IMO rehabilitation in AM and NAM patients. Most common event for IMO wearers (AM and NAM) was replacement of retention insert. Conclusion AM patients presented suboptimum masticatory function whether using CD or IMO. CD wearers with AM also had a reduced MOBF compared with NAM patients. Clinical relevance Clinicians should carefully monitor residual ridge resorption to guide treatment planning and prognosis, particularly in cases of AMs. Our findings indicate that AMs may negatively impact the clinical performance of both CD and IMO rehabilitations.


  • Impact of Complete Denture Use on Swallowing Function of Older Adults: A Systematic Review and Meta‐Analysis

    by Juliana de Castro Godinho, Mariana Marinho Davino de Medeiros, Guilherme Almeida Borges, Marcelo Ferraz Mesquita, Lucianne Cople Maia, Renata Cunha Matheus Rodrigues Garcia

    Background: The use of complete dentures (CDs) in edentulous individuals causes changes in the oral cavity and pharynx, potentially beneficially affecting swallowing function. Objective: This systematic review and meta‐analysis aimed to evaluate the immediate effects of CDs use on the swallowing function of older adults. Methods: According to the PICO framework, the search strategy was applied in six databases, grey literature and trials registration databases to retrieve clinical trials comparing the swallowing function of older adults with and without CDs. Data were extracted, and the risk of bias was assessed using the Risk of Bias in Non‐randomised Studies of Interventions (ROBINS‐I) tool. Standard mean difference (SMD) and 95% confidence intervals (95% CI) were used in meta‐analyses for hyoid, laryngeal and mandible displacements, oral (OTT) and pharyngeal transit time (PTT), posterior pharyngeal wall (PPW), upper oesophageal sphincter (UES) and tongue pressure ( α = 0.05). Results: Ten articles were included in the systematic review. Videofluorography was the swallowing assessment method most used ( n = 5). Most studies ( n = 4) had a low risk of bias. Meta‐analyses showed higher laryngeal displacement in horizontal (SMD = 0.30; 95% CI = 0.05–0.56) and vertical (SMD = 0.38; 95% CI = 0.06–0.69) directions, mandible displacement in the horizontal direction (SMD = 0.55; 95% CI = 0.22–0.89), and PPW contraction (SMD = 0.33; 95% CI = 0.07–0.58) without CDs than with CDs ( p < 0.05). No significant differences were found for mandible displacement in the vertical direction, UES opening, OTT, PTT and tongue pressure ( p > 0.05). Conclusion: The use of CDs seems to restore the swallowing function among edentulous older adults in terms of laryngeal and mandible displacement, and PPW contraction.


  • Open Access

    CAD/CAM single prosthesis: A 25 years bibliometric assessment of prosthetic outcomes

    by Letícia Del Rio Silva, Daniele Valente Velôso, Valentim A. R. Barão, Marcelo Ferraz Mesquita, Guilherme Almeida Borges


  • Open Access

    Carbon fiber-reinforced PEEK as a framework material for single implant-retained mandibular overdentures

    by Guilherme Almeida Borges, Marcelo Ferraz Mesquita, Luana Figueiredo da Silva Matias, Thaís Barbin, Leonardo Mendes Ribeiro Machado, Valentim Adelino Ricardo Barão

    This study aimed to assess the biomechanical behavior of reinforcement materials [cobalt chromium alloy (CoCr) and carbon fiber-reinforced polyether ether ketone (CFR-PEEK)] and their extensions (short: 15 mm and long: 25 mm) of single implant-retained mandibular overdentures (MO-1) by 3D finite element analysis (FEA), comparing them with MO-1 without a framework. Five models (CoCr-Short, CFR-PEEK-Short, CoCr-Long, CFR-PEEK-Long, and no framework) were created using the McNeel Rhinoceros 3D software, version 7.0. Stress distribution analysis by FEA was performed using the Optstruct solver, and a 30° oblique load (100 N) was applied in the anterior region (50 N on each central incisor). Biomechanical behavior was analyzed by overdenture displacement, maximum (MaxP) and minimum principal (MinP) stress, and von Mises stress. The MO-1 model ‘without a framework’ produced the largest dislocation, MinP stress on the mucosa, and MaxP stress in the cortical bone. Regardless of the extension of the framework, CFR-PEEK had minor MinP stress in the mucosa and lower overdenture displacement. The ‘CoCr-Long’ and ‘CFR-PEEK-Long’ models had higher von Mises stress on the implant housing, and MaxP stress on the O’ring nylon conventional implant and overdenture. The ‘CoCr-Short’ and ‘ CFR-PEEK-Short’ models showed a greater tendency for tension concentration solely in the framework. The incorporation of a framework into MO-1 decreased stress concentration on the overdenture, resulting in lower stress on the attachment, mucosa, implant, and peri-implant bone, irrespective of the material used. The short framework, however, performed better biomechanically in MO-1, and it is therefore the most recommended option. CFR-PEEK showed favorable biomechanical outcomes, and is suggested for reinforcement of MO-1.

  • Hot isostatic pressing as an alternative thermo‐mechanical treatment for metallic full‐arch implant‐supported frameworks obtained by additive and subtractive manufacturing technology: Vertical and horizontal fit, screw removal torque, and stress analysis

    by Thaís Barbin, Guilherme Almeida Borges, André Luiz Jardini, Marcelo Ferraz Mesquita

    Purpose: To assess vertical and horizontal fit, screw removal torque, and stress analysis (considered biomechanical aspects) of full‐arch implant frameworks manufactured in Ti‐6Al‐4V through milling, and additive manufacturing Direct Metal Laser Sintering (DMLS) and Electron Beam Melting (EBM), and the effect of the thermo‐mechanical treatment Hot Isostatic Pressing (HIP) as a post‐treatment after manufacturing.Material and Methods: Maxillary full‐arch implant frameworks were made by milling, DMLS, and EBM. The biomechanical assessments were screw removal torque, strain‐gauge analyses, and vertical and horizontal marginal fits. The vertical fit was assessed by the single‐screw test and with all screws tightened. All frameworks were submitted to a standardized HIP cycle (920°C, 1000 bar pressure, 2 h), and the tests were repeated (α = 0.05).Results: At the initial time, milled frameworks presented higher screw removal torque values, and DMLS and EBM frameworks presented lower levels of strain. Using the single‐screw test, milled and DMLS frameworks presented higher vertical fit values, and with all screws tightened and horizontally, higher fit values were found for milled frameworks, followed by DMLS and EBM. After HIP, milling and EBM frameworks presented higher screw removal torque values; the lowest strain values were found for EBM. Using the single‐screw test, milled and DMLS frameworks presented higher vertical fit values, and with all screws tightened and horizontally no differences were found.Conclusions: DMLS and EBM full‐arch frameworks presented adequate values of screw removal torque, strain, and marginal fit, although the worst values of marginal fit were found for EBM frameworks. The HIP cycle enhanced the screw removal torque of milled and EBM frameworks and reduced the strain values of milled frameworks. The HIP represents a reliable post‐treatment for Ti‐6Al‐4V dental prostheses produced by milling and EBM technologies.