GDGuillaume Duhamel

Guillaume Duhamel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Guillaume Duhamel has a total of 197 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Open Test–Retest Dataset of Rapid Myelin Mapping Acquisitions

    by Steven L. Meisler, Taylor Salo, Matthew Cieslak, Brooke L. Sevchik, Juliette Brook, Guillaume Duhamel, Olivier M. Girard, Bart Larsen, Shraddha Pandey, Lucinda M. Sisk, et al.

    Myelin supports rapid and efficient neural communication and is implicated in brain development, learning, aging, and neurological disease. Although numerous magnetic resonance imaging (MRI) approaches have been proposed to characterize myelin in vivo, they have rarely been evaluated together within the same participants and across repeated acquisitions. To address these gaps, we introduce the Myelin Imaging Reliability and ReprOducibility Resource (MIRROR), an openly available multimodal test– retest MRI dataset of diffusion MRI (dMRI), inhomogeneous magnetization transfer imaging (ihMT), quantitative susceptibility mapping (QSM), MP2RAGE, T 1 w/T 2 w ratio mapping, and transverse relaxometry in 22 healthy adults. We evaluated gray–white matter differentiation, intermetric correspondence, test–retest reliability, and participant specificity across 27 myelin-sensitive metrics. Gray–white matter differentiation was strong for dMRI derivatives, MP2RAGE-derived R 1 , T 1 w/T 2 w, and ihMT, while being substantially weaker for QSM measures. Intermetric spatial correlations were generally strongest within acquisition or modeling families. Test–retest reliability was generally high, particularly for dMRI-derived metrics, but was more variable among QSM-, ihMT-, and R 2 *-derived measures. Regional spatial profiles were also highly participant-specific, with discriminability approaching its upper bound for most metrics. All imaging data, derived maps, and processing code are openly released. MIRROR provides a benchmark for characterizing the measurement properties and practical tradeoffs of scalable myelin-sensitive MRI methods, supporting principled acquisition selection and accelerating methodological development and validation.

  • Open Access

    Reducing Inhomogeneous MT ( ihMT ) Acquisition Time Using Frequency Alternation at Low Duty Cycle for Single Offset ( FALSO ) MT Preparations

    by Gopal Varma, Aaron K. Grant, Lucas Soustelle, Olivier M. Girard, Guillaume Duhamel, David C. Alsop

    Purpose: To evaluate Frequency Alternation at Low duty cycle for Single Offset (FALSO) as a novel Magnetization Transfer (MT) preparation scheme to increase speed and/or spatial resolution of inhomogeneous MT (ihMT) MRI by reducing the number of volumes required. Methods: We compared FALSO MT to standard single frequency MT preparations using signal simulations and ihMT data acquired in a rat brain at 9.4 T and human brains at 3 T. Using FALSO MT preparations, combined with optimized Variable Flip Angle (VFA) MPRAGE readouts, we also acquired ihMT data at high resolution (down to 1.4 mm isotropic) to demonstrate the reduction in acquisitions required for ihMT images of sufficient SNR. Results: We found no statistically significant difference between ihMT ratios from data acquired using FALSO MT preparations versus averaging data following separate positive and negative frequency offset MT acquisitions (as in regular ihMT to account for MT asymmetry). Use of VFA (relative to constant flip angle) readouts allowed high‐resolution ihMT images with a minimal number of volumes to be acquired and reduced variance in ihMT ratios within ROIs. Conclusion: FALSO MT preparations allow for a reduction in the number of acquisitions required for ihMT while still controlling for MT asymmetry. IhMT data acquired with VFA readouts allow for higher resolution acquisitions in the same scan time. The combination of FALSO MT and VFA readouts can be used to increase the spatial and/or temporal resolution of ihMT experiments, allowing for easier clinical translation and improving the utility of ihMT in neurological studies of myelin.

  • Open Access

    Structural Characterization of Cardiac Purkinje Fibers Using Inhomogeneous Magnetization Transfer (ihMT): A proof of Concept MRI-Histology Approach

    by Arash Forodighasemabadi, Evgenios N. Kornaropoulos, Marion Constantin, Lucas Soustelle, Fanny Vaillant, Jude Leury, Richard Walton, Olivier Bernus, Bruno Quesson, Olivier M. Girard, et al.

    BACKGROUND: The cardiac Purkinje network plays a critical role in maintaining synchronized activation of ventricles but remains challenging to image due to its fine and unique structure. Conventional MRI techniques lack sufficient contrast to distinguish the underlying structural composition of Purkinje Fibers (PF). PURPOSE: This study investigates the potential of inhomogeneous Magnetization Transfer (ihMT) as a novel contrast mechanism for visualizing and differentiating subregions of the PF. METHODS: Five fixed ex-vivo sheep hearts (n = 5) containing free running PF were scanned with a 9.4T MRI using a 2D ihMT RARE sequence. ASSESSMENT: ihMTR maps were analyzed using manually defined regions-of-interest (ROIs) corresponding to free-running PF, insertion points, and myocardium. Histological analysis (light and polarized microscopy) was performed on matched sections to quantify collagen types I and III, adipocytes, Purkinje cells, and cardiomyocytes. RESULTS: Three ihMT protocols, which produced high ihMTR values in free-running PF (9.25–10.83%) and strong absolute contrast relative to the myocardium (2.00–2.17%) and insertion points (2.99–3.40%) in one sample were selected and applied to all samples. Across all samples, mean ihMTR in free-running was consistently higher than in insertion points (11.5 ± 1.5% vs. 9.0 ± 2.9%). Histological analysis revealed a significantly greater collagen content in free-running regions compared with insertion points (72.4 ± 15.9% vs. 31.1 ± 13.1%; p = 0.001), along with higher adipocyte content at insertion points vs. free-running regions (12.3 ± 6.1% vs. 3.8 ± 2.7%, non-significant). Collagen type III was more prominent at insertion points but remained a minor component overall. CONCLUSION: ihMT imaging can distinguish PF subregions based on microstructural differences, particularly collagen and adipocyte distribution. This study lays the groundwork for developing biophysical models to interpret ihMT signals in terms of tissue composition and microstructure, providing a foundation for future studies. Sponsor: This study received financial support from the French Government by the National Research Agency (ANR; SYNATRA ANR-21-CE19-0014-01) and Région Nouvelle Aquitaine (convention N°AAPR2022-2021-16609210).

  • Open Access

    Inhomogeneous magnetization transfer (ihMT) imaging reveals variable recovery profiles of active MS lesions according to size and localization

    by Lucas Soustelle, Samira Mchinda, Andreea Hertanu, Soraya Gherib, Lauriane Pini, Maxime Guye, Jean-Philippe Ranjeva, Gopal Varma, David C. Alsop, Jean Pelletier, et al.

    This work aims at exploiting the unique myelin specificity of the inhomogeneous magnetization transfer (ihMT) technique to characterize the recovery dynamics of active multiple sclerosis (MS) lesions. IhMT and three other myelin-sensitive techniques, conventional MT, T1-weighted, and diffusion tensor imaging, were applied in a 12-month longitudinal study performed on relapsing-remitting MS patients. An exponential recovery model was used to fit the variations over time of the metrics derived from each MR technique within new active lesions. A principal component analysis was performed on the model parameters obtained for all MR myelin-sensitive techniques across all active lesions of all patients to identify specific recovery profiles. The results show that the recovery profiles of myelin-sensitive MR metrics in active MS lesions vary according to the localization and size of lesions. The distance of lesions from the ventricles is positively associated with the recovery rates of ihMTR and T1w-MPRAGE: the further the lesion is from the ventricles, the higher the recovery rate of these metrics. Lesion size is positively associated with initial loss and negatively associated with final recovery of ihMTR and other MR metrics: small lesions have lower initial loss and greater final recovery of MR metrics than large lesions. Thanks to the specificity of the ihMT technique for myelin, these features can be interpreted in terms of remyelination. This study thus provides longitudinal in vivo support for the pathological observations of higher remyelination in small lesions compared with large ones and faster remyelination in lesions away from the ventricles. These results support the use of ihMT and other measures for quantifying remyelination rates in clinical studies of remyelination therapies.


  • Open Access

    Quantitative magnetization transfer MRI unbiased by on‐resonance saturation and dipolar order contributions

    by Lucas Soustelle, Thomas Troalen, Andreea Hertanu, Jean‐Philippe Ranjeva, Maxime Guye, Gopal Varma, David C. Alsop, Guillaume Duhamel, Olivier M. Girard

    Purpose: To demonstrate the bias in quantitative MT (qMT) measures introduced by the presence of dipolar order and on‐resonance saturation (ONRS) effects using magnetization transfer (MT) spoiled gradient‐recalled (SPGR) acquisitions, and propose changes to the acquisition and analysis strategies to remove these biases.Methods: The proposed framework consists of SPGR sequences prepared with simultaneous dual‐offset frequency‐saturation pulses to cancel out dipolar order and associated relaxation (T1D) effects in Z‐spectrum acquisitions, and a matched quantitative MT (qMT) mathematical model that includes ONRS effects of readout pulses. Variable flip angle and MT data were fitted jointly to simultaneously estimate qMT parameters (macromolecular proton fraction [MPF], T2,f, T2,b, R, and free pool T1). This framework is compared with standard qMT and investigated in terms of reproducibility, and then further developed to follow a joint single‐point qMT methodology for combined estimation of MPF and T1.Results: Bland–Altman analyses demonstrated a systematic underestimation of MPF (−2.5% and −1.3%, on average, in white and gray matter, respectively) and overestimation of T1 (47.1 ms and 38.6 ms, on average, in white and gray matter, respectively) if both ONRS and dipolar order effects are ignored. Reproducibility of the proposed framework is excellent (ΔMPF = −0.03% and ΔT1 = −19.0 ms). The single‐point methodology yielded consistent MPF and T1 values with respective maximum relative average bias of −0.15% and −3.5 ms found in white matter.Conclusion: The influence of acquisition strategy and matched mathematical model with regard to ONRS and dipolar order effects in qMT‐SPGR frameworks has been investigated. The proposed framework holds promise for improved accuracy with reproducibility.


  • Open Access

    Inhomogeneous Magnetization Transfer (ihMT) imaging in the acute cuprizone mouse model of demyelination/remyelination

    by Andreea Hertanu, Lucas Soustelle, Julie Buron, Julie Le Priellec, Myriam Cayre, Arnaud Le Troter, Valentin H. Prevost, Jean-Philippe Ranjeva, Gopal Varma, David C. Alsop, et al.


  • Inhomogeneous magnetization transfer imaging: Concepts and directions for further development

    by David C. Alsop, Ece Ercan, Olivier M. Girard, Alex L. Mackay, Carl A. Michal, Gopal Varma, Elena Vinogradov, Guillaume Duhamel

    Off‐resonance radio frequency irradiation can induce the ordering of proton spins in the dipolar fields of their neighbors, in molecules with restricted mobility. This dipolar order decays with a characteristic relaxation time, T1D, that is very different from the T1 and T2 relaxation of the nuclear alignment with the main magnetic field. Inhomogeneous magnetization transfer (ihMT) imaging is a refinement of magnetization transfer (MT) imaging that isolates the MT signal dependence on dipolar order relaxation times within motion‐constrained molecules. Because T1D relaxation is a unique contrast mechanism, ihMT may enable improved characterization of tissue. Initial work has stressed the high correlation between ihMT signal and myelin density. Dipolar order relaxation appears to be much longer in membrane lipids than other molecules. Recent work has shown, however, that ihMT acquisitions may also be adjusted to emphasize different ranges of T1D. These newer approaches may be sensitive to other microstructural components of tissue. Here, we review the concepts and history of ihMT and outline the requirements for further development to realize its full potential.


  • Open Access

    Brain grey matter perfusion in primary progressive multiple sclerosis: Mild decrease over years and regional associations with cognition and hand function

    by Benoit Testud, Clara Delacour, Ahmed Ali El Ahmadi, Gilles Brun, Nadine Girard, Guillaume Duhamel, Christoph Heesen, Vivien Häußler, Christian Thaler, Arzu Ceylan Has Silemek, et al.

    Background Extend and dynamic of neurodegeneration in progressive Multiple Sclerosis (MS) might be reflected by global and regional brain perfusion, an outcome at the intercept between structure and function. Here, we provide a first insight in the evolution of brain perfusion and its association with disability in primary progressive MS (PPMS) over several years. Methods 77 persons with PPMS were followed over up to 5 years. Visits included a 3T MRI with pulsed Arterial spin labelling (ASL) perfusion, the Timed-25-Foot-Walk, 9-Hole-Peg-Test (NHPT), Symbol-Digit-Modalities-Test (SDMT) and Expanded Disability Status Scale (EDSS). We extracted regional cerebral blood flow surrogates and compared them to 11 controls. Analyses focused in cortical and deep gray matter, the change over time and associations with disability on regional and global level. Results Baseline brain perfusion of patients and controls was comparable for the cortex (p=0.716) and deep grey matter (p=0.095). EDSS disability increased mildly (p=0.023) while brain perfusion decreased during follow up (p<0.001) and with disease duration (p=0.009). Lower global perfusion correlated with higher disability as indicated by EDSS, NHPT and Timed-25-Foot-Walk (p<0.001). The motor task NHPT showed associations with twenty gray matter regions. In contrast, better SDMT performance correlated with lower perfusion (p<0.001) in seven predominantly frontal regions indicating a functional maladaptation. Conclusion Decreasing perfusion indicates a putative association with MS disease mechanisms such as neurodegeneration, reduced metabolism, and loss of resilience. A low alteration rate limits its use in clinical practice, but regional association patterns might provide a snapshot of adaptive and maladaptive functional reorganization.


  • T1D‐weighted ihMT imaging – Part I. Isolation of long‐ and short‐T1D components by T1D‐filtering

    by Andreea Hertanu, Lucas Soustelle, Arnaud Le Troter, Julie Buron, Julie Le Priellec, Victor N. D. Carvalho, Myriam Cayre, Pascale Durbec, Gopal Varma, David C. Alsop, et al.

    Purpose: To identify T1D‐filtering methods, which can specifically isolate various ranges of T1D components as they may be sensitive to different microstructural properties.Methods: Modified Bloch‐Provotorov equations describing a bi‐T1D component biophysical model were used to simulate the inhomogeneous magnetization transfer (ihMT) signal from ihMTRAGE sequences at high RF power and low duty‐cycle with different switching time values for the dual saturation experiment: Δt = 0.0, 0.8, 1.6, and 3.2 ms. Simulations were compared with experimental signals on the brain gray and white matter tissues of healthy mice at 7T.Results: The lengthening of Δt created ihMT high‐pass T1D‐filters, which efficiently eliminated the signal from T1D components shorter than 1 ms, while partially attenuating that of longer components (≥ 1 ms). Subtraction of ihMTR images obtained with Δt = 0.0 ms and Δt = 0.8 ms generated a new ihMT band‐pass T1D‐filter isolating short‐T1D components in the 100‐µs to 1‐ms range. Simulated ihMTR values in central nervous system tissues were confirmed experimentally.Conclusion: Long‐ and short‐T1D components were successfully isolated with high RF power and low duty‐cycle ihMT filters in the healthy mouse brain. Future studies should investigate the various T1D‐range microstructural correlations in in vivo tissues.


  • T1D‐weighted ihMT imaging – Part II. Investigating the long‐ and short‐T1D components correlation with myelin content. Comparison with R1 and the macromolecular proton fraction

    by Andreea Hertanu, Lucas Soustelle, Julie Buron, Julie Le Priellec, Myriam Cayre, Arnaud Le Troter, Gopal Varma, David C. Alsop, Pascale Durbec, Olivier M. Girard, et al.

    Purpose: To investigate the long‐ and short‐T1D components correlation with myelin content using inhomogeneous magnetization transfer (ihMT) high‐pass and band‐pass T1D‐filters and to compare ihMT, R1, and the macromolecular proton fraction (MPF) for myelin specific imaging.Methods: The 3D ihMT rapid gradient echo (ihMTRAGE) sequences with increasing switching times (Δt) were used to derive ihMT high‐pass T1D‐filters with increasing T1D cutoff values and an ihMT band‐pass T1D‐filter for components in the 100 µs to 1 ms range. 3D spoiled gradient echo quantitative MT (SPGR‐qMT) protocols were used to derive R1 and MPF maps. The specificity of R1, MPF, and ihMT T1D‐filters was evaluated by comparison with two histological reference techniques for myelin imaging.Results: The higher contribution of long‐T1Ds as compared to the short components as Δt got longer led to an increase in the specificity to myelination. In contrast, focusing on the signal originating from a narrow range of short‐T1Ds (< 1 ms) as isolated by the band‐pass T1D‐filter led to lower specificity. In addition, the significantly lower r2 correlation coefficient of the band‐pass T1D‐filter suggests that the origin of short‐T1D components is mostly associated with non‐myelin protons. Also, the important contribution of short‐T1Ds to the estimated MPF, explains its low specificity to myelination as compared to the ihMT high‐pass T1D‐filters.Conclusion: Long‐T1D components imaging by means of ihMT high‐pass T1D‐filters is proposed as an MRI biomarker for myelin content. Future studies should enable the investigation of the sensitivity of ihMT T1D‐filters for demyelinating processes.