Yao Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yao Fan has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Chao Zuo
Nanjing Univ. of Science and Technology
10 shared publications - Jiasong Sun
Nanjing University of Science and Technology
5 shared publications - Qian Chen
School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
4 shared publications - Yefeng Shu
Smart Computational Imaging Laboratory (SCILab), School of Electronic and Optical Engineering, Nanjing University of Science and Technology 1 , Nanjing, Jiangsu Province 210094
4 shared publications - Maciej Trusiak
Warsaw University of Technology
3 shared publications Jiasong Sun
Nanjing University of Science and Technology, School of Electronic and Optical Engineering, Smart Computational Imaging Laboratory (SCILab), Nanjing, China
2 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by AIP Publishing in APL Photonics
- Vol. 11 (4)
Single-shot quantitative differential phase contrast microscopy based on support-domain constraint
Differential phase contrast (DPC) microscopy is a powerful non-interferometric quantitative phase imaging (QPI) technique widely used for label-free visualization of transparent specimens under partially coherent illumination. However, its reliance on multi-frame acquisitions to ensure isotropic phase reconstruction inherently limits imaging speed, hindering the observation of fast biological dynamics. Here, we present support-domain-constraint DPC (SDC-DPC), a single-shot, isotropic-resolution QPI method that reconstructs quantitative phase maps from only one raw intensity image. By employing an optimized uniform semi-ring illumination to enhance the uniformity of the phase transfer function and incorporating a spatial support constraint into an iterative reconstruction framework, SDC-DPC compensates for the missing frequency components and suppresses the directional artifacts inherent to single-directional DPC. Simulations and experiments demonstrate that SDC-DPC achieves phase reconstruction accuracy and resolution comparable to conventional four-frame DPC for both static and dynamic samples, while completely eliminating motion artifacts in live-cell imaging. This work establishes a simple yet powerful paradigm that transforms DPC into a single-shot quantitative phase microscopy modality, opening new avenues for label-free imaging of dynamic biological processes.
- 1 April 2026
- Published by AIP Publishing in APL Photonics
- Vol. 11 (4)
Open AccessSingle-shot quantitative differential phase contrast microscopy based on support-domain constraint
Differential phase contrast (DPC) microscopy is a powerful non-interferometric quantitative phase imaging (QPI) technique widely used for label-free visualization of transparent specimens under partially coherent illumination. However, its reliance on multi-frame acquisitions to ensure isotropic phase reconstruction inherently limits imaging speed, hindering the observation of fast biological dynamics. Here, we present support-domain-constraint DPC (SDC-DPC), a single-shot, isotropic-resolution QPI method that reconstructs quantitative phase maps from only one raw intensity image. By employing an optimized uniform semi-ring illumination to enhance the uniformity of the phase transfer function and incorporating a spatial support constraint into an iterative reconstruction framework, SDC-DPC compensates for the missing frequency components and suppresses the directional artifacts inherent to single-directional DPC. Simulations and experiments demonstrate that SDC-DPC achieves phase reconstruction accuracy and resolution comparable to conventional four-frame DPC for both static and dynamic samples, while completely eliminating motion artifacts in live-cell imaging. This work establishes a simple yet powerful paradigm that transforms DPC into a single-shot quantitative phase microscopy modality, opening new avenues for label-free imaging of dynamic biological processes.
- Open Access
- 15 February 2026
- Published by SPIE-Intl Soc Optical Eng in Advanced Photonics
- Vol. 8 (02) , 1-15
Spatiotemporal-multiplexed Fourier ptychographic diffraction tomography for high-speed, label-free 3D imaging of live cells
Label-free, three-dimensional (3D) imaging of organelle dynamics at high spatiotemporal resolution is essential for deciphering cellular physiology. While optical diffraction tomography (ODT) can retrieve intrinsic-contrast 3D refractive-index distribution of transparent cells, its sequential, variable-angle acquisition compromises temporal resolution, obscuring rapid events such as membrane blebbing, vesicle trafficking, and cytoskeletal remodeling. Here, we introduce spatiotemporal-multiplexed Fourier ptychographic diffraction tomography (STM-FPDT), a noninterferometric ODT modality that employs hybrid coherent/partially coherent annular illumination to achieve high resolution in both space (x−y−z) and time (t). By integrating a spatiotemporal reconstruction framework with a sliding window protocol and nonlinear global optimization, STM-FPDT achieves volumetric imaging at 5 Hz with 347 nm lateral and 1.54 μm axial resolution over a 40×/0.75 NA objective. We validate STM-FPDT across diverse cell lines, successfully capturing membrane blebbing, mitochondrial fission, and intercellular interactions that evade conventional ODT. Readily retrofittable to standard bright-field microscopes, STM-FPDT offers a broadly accessible platform for quantitative, high-spatiotemporal-resolution studies of live-cell physiology.
- 15 February 2026
- Published by SPIE-Intl Soc Optical Eng in Advanced Photonics
- Vol. 8 (02) , 1-15
Open AccessSpatiotemporal-multiplexed Fourier ptychographic diffraction tomography for high-speed, label-free 3D imaging of live cells
Label-free, three-dimensional (3D) imaging of organelle dynamics at high spatiotemporal resolution is essential for deciphering cellular physiology. While optical diffraction tomography (ODT) can retrieve intrinsic-contrast 3D refractive-index distribution of transparent cells, its sequential, variable-angle acquisition compromises temporal resolution, obscuring rapid events such as membrane blebbing, vesicle trafficking, and cytoskeletal remodeling. Here, we introduce spatiotemporal-multiplexed Fourier ptychographic diffraction tomography (STM-FPDT), a noninterferometric ODT modality that employs hybrid coherent/partially coherent annular illumination to achieve high resolution in both space (x−y−z) and time (t). By integrating a spatiotemporal reconstruction framework with a sliding window protocol and nonlinear global optimization, STM-FPDT achieves volumetric imaging at 5 Hz with 347 nm lateral and 1.54 μm axial resolution over a 40×/0.75 NA objective. We validate STM-FPDT across diverse cell lines, successfully capturing membrane blebbing, mitochondrial fission, and intercellular interactions that evade conventional ODT. Readily retrofittable to standard bright-field microscopes, STM-FPDT offers a broadly accessible platform for quantitative, high-spatiotemporal-resolution studies of live-cell physiology.
- Open Access
- 1 October 2025
- Published by AIP Publishing in APL Photonics
- Vol. 10 (10)
Efficient misalignment correction method for dark-field aperture in reflective Fourier ptychographic microscopy
Reflective Fourier ptychographic microscopy (FPM) enables high-resolution, wide-field imaging of opaque surfaces, but its calibration remains challenging due to the unique illumination geometry. Unlike transmissive FPM, which typically employs a regular planar LED array, reflective systems use spatially separated bright-field and dark-field illuminations, with dark-field LEDs arranged around the outer periphery of the objective lens. This non-coplanar, discontinuous configuration invalidates conventional LED calibration methods that generally rely on array continuity or bright-field sub-aperture priors. Here, we propose a non-iterative dark-field misalignment correction method tailored for reflective FPM, referred to as dmc-rFPM. This method formulates a residual cost function based on the structural similarity index between the predicted and measured dark-field intensity images. Each dark-field sub-aperture is independently aligned via heuristic search, and global geometric consistency is enforced using a RANSAC-based circular fitting strategy. This approach eliminates the need for object reconstruction or bright-field-based initialization, supports efficient parallel implementation, and significantly reduces correction time. Simulations and experiments on resolution targets and semiconductor chips demonstrate that dmc-rFPM effectively and precisely corrects 72 dark-field images (each with 400 000 pixels) within 0.5 s using GPU acceleration, achieving a lateral resolution of 583 nm with a 4× objective. dmc-rFPM enables diffraction-limited imaging performance and provides a practical solution for high-throughput calibration in reflective FPM systems for industrial inspection and precision metrology applications.
- 1 October 2025
- Published by AIP Publishing in APL Photonics
- Vol. 10 (10)
Open AccessEfficient misalignment correction method for dark-field aperture in reflective Fourier ptychographic microscopy
Reflective Fourier ptychographic microscopy (FPM) enables high-resolution, wide-field imaging of opaque surfaces, but its calibration remains challenging due to the unique illumination geometry. Unlike transmissive FPM, which typically employs a regular planar LED array, reflective systems use spatially separated bright-field and dark-field illuminations, with dark-field LEDs arranged around the outer periphery of the objective lens. This non-coplanar, discontinuous configuration invalidates conventional LED calibration methods that generally rely on array continuity or bright-field sub-aperture priors. Here, we propose a non-iterative dark-field misalignment correction method tailored for reflective FPM, referred to as dmc-rFPM. This method formulates a residual cost function based on the structural similarity index between the predicted and measured dark-field intensity images. Each dark-field sub-aperture is independently aligned via heuristic search, and global geometric consistency is enforced using a RANSAC-based circular fitting strategy. This approach eliminates the need for object reconstruction or bright-field-based initialization, supports efficient parallel implementation, and significantly reduces correction time. Simulations and experiments on resolution targets and semiconductor chips demonstrate that dmc-rFPM effectively and precisely corrects 72 dark-field images (each with 400 000 pixels) within 0.5 s using GPU acceleration, achieving a lateral resolution of 583 nm with a 4× objective. dmc-rFPM enables diffraction-limited imaging performance and provides a practical solution for high-throughput calibration in reflective FPM systems for industrial inspection and precision metrology applications.
- 18 December 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12967, 15-19
A flexible and controllable condenser device based on programmable LCD for multi-modal imaging
The rise of “computational optics” provides a new way for label-free microscopic imaging. Programmable illumination modulation devices [light emitting diode (LED), liquid-crystal-display (LCD), or spatial light modulator (SLM)] have been introduced into light microscopes to give them multimodal imaging capabilities. Nevertheless, due to the discontinuity of the LED array and the high light loss of the LCD, the existing illumination modulation scheme still needs to be optimized. In this paper, we report a programmable illumination modulation condenser for multi-modal microscopic imaging. By placing a high transmittance LCD inside a condenser, this device enables flexible modulation of the illumination light wavelength and angle without altering the existing optical layout. The high transmittance LCD greatly increases the transmittance of illumination light, which is further converged on the sample by the condenser, resulting in higher illumination intensity to produce high contrast images. In addition, the programmable condenser can be used as a flexible add-on module compatible with any commercial microscope to extend the imaging modality of conventional bright-field microscopes. Ultimately, we validated the accuracy and dependability of the programmable illumination modulation condenser by imaging spongy germ cells.
- 18 December 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12967, 15-19
A flexible and controllable condenser device based on programmable LCD for multi-modal imaging
The rise of “computational optics” provides a new way for label-free microscopic imaging. Programmable illumination modulation devices [light emitting diode (LED), liquid-crystal-display (LCD), or spatial light modulator (SLM)] have been introduced into light microscopes to give them multimodal imaging capabilities. Nevertheless, due to the discontinuity of the LED array and the high light loss of the LCD, the existing illumination modulation scheme still needs to be optimized. In this paper, we report a programmable illumination modulation condenser for multi-modal microscopic imaging. By placing a high transmittance LCD inside a condenser, this device enables flexible modulation of the illumination light wavelength and angle without altering the existing optical layout. The high transmittance LCD greatly increases the transmittance of illumination light, which is further converged on the sample by the condenser, resulting in higher illumination intensity to produce high contrast images. In addition, the programmable condenser can be used as a flexible add-on module compatible with any commercial microscope to extend the imaging modality of conventional bright-field microscopes. Ultimately, we validated the accuracy and dependability of the programmable illumination modulation condenser by imaging spongy germ cells.
- 18 December 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12967, 19-88
Phase recovery method for PTF and PGTF spectrum fusion based on optimized illumination
Differential phase contrast (DPC) imaging is a non-interferometric, label-free and efficient quantitative phase imaging method based on partially coherent illumination modulation, of which the two widely used forms are the method based on the slow-variable-object approximation solved by the phase gradient transfer function (PGTF) and the method based on the weak-object approximation solved by the phase transfer function (PTF). Both methods can recover the phase well under their respective approximations, but for phase recovery of certain complex phase objects in reality, they are lackluster due to the limitations imposed by their use of approximations. To break this limitation, a spectral fusion method is proposed in this paper, which can take into account the low-frequency generalization and high-frequency details of phase objects and achieve efficient and accurate quantitative phase imaging by effectively merging the phases reconstructed by PTF and PGTF in the frequency domain on the basis of optimized illumination. Relevant simulations and experiments demonstrate the effectiveness of the method.
- 18 December 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12967, 19-88
Phase recovery method for PTF and PGTF spectrum fusion based on optimized illumination
Differential phase contrast (DPC) imaging is a non-interferometric, label-free and efficient quantitative phase imaging method based on partially coherent illumination modulation, of which the two widely used forms are the method based on the slow-variable-object approximation solved by the phase gradient transfer function (PGTF) and the method based on the weak-object approximation solved by the phase transfer function (PTF). Both methods can recover the phase well under their respective approximations, but for phase recovery of certain complex phase objects in reality, they are lackluster due to the limitations imposed by their use of approximations. To break this limitation, a spectral fusion method is proposed in this paper, which can take into account the low-frequency generalization and high-frequency details of phase objects and achieve efficient and accurate quantitative phase imaging by effectively merging the phases reconstructed by PTF and PGTF in the frequency domain on the basis of optimized illumination. Relevant simulations and experiments demonstrate the effectiveness of the method.
- 18 December 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12963, 42-266
Automatic correction method of optical microscope displacement stage based on Hough transform
Computational optical microscopy can obtain multidimensional and microscopic sample images and information that cannot be observed by the naked eye. However, due to limitations in hardware manufacturing level, optical deployment methods, and detection tools, there are often errors between the actual imaging system and its physical model, which makes it difficult for computational optical microscopy to achieve stable imaging functions and obtain high-quality observation images. This paper introduces an automatic correction method for microscope stage based on Hough Transform image processing. It does not require manual operation and only requires image processing of the imaging results to complete the correction fully automatically. The correction process is simple and fast, with better visualization and accuracy for the imaging results. It can greatly improve the efficiency of stage correction and ensure that the computational optical microscopy system can obtain high-quality observation images, and it can be universally applicable to optical microscopy systems with electrically controlled displacement stage.
- 18 December 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12963, 42-266
Automatic correction method of optical microscope displacement stage based on Hough transform
Computational optical microscopy can obtain multidimensional and microscopic sample images and information that cannot be observed by the naked eye. However, due to limitations in hardware manufacturing level, optical deployment methods, and detection tools, there are often errors between the actual imaging system and its physical model, which makes it difficult for computational optical microscopy to achieve stable imaging functions and obtain high-quality observation images. This paper introduces an automatic correction method for microscope stage based on Hough Transform image processing. It does not require manual operation and only requires image processing of the imaging results to complete the correction fully automatically. The correction process is simple and fast, with better visualization and accuracy for the imaging results. It can greatly improve the efficiency of stage correction and ensure that the computational optical microscopy system can obtain high-quality observation images, and it can be universally applicable to optical microscopy systems with electrically controlled displacement stage.
- 1 March 2023
- Published by Optica Publishing Group in Photonics Research
- Vol. 11 (3) , 442-455
Accurate quantitative phase imaging by differential phase contrast with partially coherent illumination: beyond weak object approximation
Quantitative phase imaging (QPI) by differential phase contrast (DPC) with partially coherent illumination provides speckle-free imaging and lateral resolution beyond the coherent diffraction limit, demonstrating great potential in biomedical imaging applications. Generally, DPC employs weak object approximation to linearize the phase-to-intensity image formation, simplifying the solution to the phase retrieval as a two-dimensional deconvolution with the corresponding phase transfer function. Despite its widespread adoption, weak object approximation still lacks a precise and clear definition, suggesting that the accuracy of the QPI results, especially for samples with large phase values, is yet to be verified. In this paper, we analyze the weak object approximation condition quantitatively and explicitly give its strict definition that is applicable to arbitrary samples and illumination apertures. Furthermore, an iterative deconvolution QPI technique based on pseudo-weak object approximation is proposed to overcome the difficulty of applying DPC to large-phase samples without additional data acquisition. Experiments with standard microlens arrays and MCF-7 cells demonstrated that the proposed method can effectively extend DPC beyond weak object approximation to high-precision three-dimensional morphological characterization of large-phase technical and biological samples.
- 1 March 2023
- Published by Optica Publishing Group in Photonics Research
- Vol. 11 (3) , 442-455
Accurate quantitative phase imaging by differential phase contrast with partially coherent illumination: beyond weak object approximation
Quantitative phase imaging (QPI) by differential phase contrast (DPC) with partially coherent illumination provides speckle-free imaging and lateral resolution beyond the coherent diffraction limit, demonstrating great potential in biomedical imaging applications. Generally, DPC employs weak object approximation to linearize the phase-to-intensity image formation, simplifying the solution to the phase retrieval as a two-dimensional deconvolution with the corresponding phase transfer function. Despite its widespread adoption, weak object approximation still lacks a precise and clear definition, suggesting that the accuracy of the QPI results, especially for samples with large phase values, is yet to be verified. In this paper, we analyze the weak object approximation condition quantitatively and explicitly give its strict definition that is applicable to arbitrary samples and illumination apertures. Furthermore, an iterative deconvolution QPI technique based on pseudo-weak object approximation is proposed to overcome the difficulty of applying DPC to large-phase samples without additional data acquisition. Experiments with standard microlens arrays and MCF-7 cells demonstrated that the proposed method can effectively extend DPC beyond weak object approximation to high-precision three-dimensional morphological characterization of large-phase technical and biological samples.
- 27 December 2022
- Published by Wiley in Laser & Photonics Reviews
- Vol. 17 (3)
Efficient Synthetic Aperture for Phaseless Fourier Ptychographic Microscopy with Hybrid Coherent and Incoherent Illumination
Fourier ptychographic microscopy (FPM) is a computational high‐throughput technique for high‐resolution and wide field‐of‐view (FOV) imaging applications such as cell biology, medicine screening, and digital pathology. By integrating angle‐varied illumination, iteration phase retrieval, and synthetic aperture, it achieves a significantly enhanced imaging resolution beyond the diffraction limit of the objective lens while retaining its original large FOV without any mechanical movement. However, sufficient data redundancy is a prerequisite for the convergence of the iteration algorithm, which in turn requires dozens or even hundreds of raw images to get a decent resolution, leaving ample room for further improvement. In this paper, an efficient synthetic aperture scheme for FPM is proposed, termed ESA‐FPM. It employs both coherent and incoherent illuminations to maximize the efficiency of data utilization and achieve high spatial‐bandwidth product (SBP) reconstruction with few acquisitions. The data redundancy requirements are further analyzed, suggesting that ESA‐FPM reaches imaging resolution of using only seven images. The experiment with USAF target demonstrates that ESA‐FPM achieves theoretical resolution with only 1.6% of the data of conventional FPM. A customized miniaturized ESA‐FPM system with a high‐numerical‐aperture, low‐magnification objective lens, and a high‐brightness LED array is built, demonstrating its potential for biomedical and pathological applications.
- 27 December 2022
- Published by Wiley in Laser & Photonics Reviews
- Vol. 17 (3)
Efficient Synthetic Aperture for Phaseless Fourier Ptychographic Microscopy with Hybrid Coherent and Incoherent Illumination
Fourier ptychographic microscopy (FPM) is a computational high‐throughput technique for high‐resolution and wide field‐of‐view (FOV) imaging applications such as cell biology, medicine screening, and digital pathology. By integrating angle‐varied illumination, iteration phase retrieval, and synthetic aperture, it achieves a significantly enhanced imaging resolution beyond the diffraction limit of the objective lens while retaining its original large FOV without any mechanical movement. However, sufficient data redundancy is a prerequisite for the convergence of the iteration algorithm, which in turn requires dozens or even hundreds of raw images to get a decent resolution, leaving ample room for further improvement. In this paper, an efficient synthetic aperture scheme for FPM is proposed, termed ESA‐FPM. It employs both coherent and incoherent illuminations to maximize the efficiency of data utilization and achieve high spatial‐bandwidth product (SBP) reconstruction with few acquisitions. The data redundancy requirements are further analyzed, suggesting that ESA‐FPM reaches imaging resolution of using only seven images. The experiment with USAF target demonstrates that ESA‐FPM achieves theoretical resolution with only 1.6% of the data of conventional FPM. A customized miniaturized ESA‐FPM system with a high‐numerical‐aperture, low‐magnification objective lens, and a high‐brightness LED array is built, demonstrating its potential for biomedical and pathological applications.
- Open Access
- 12 June 2021
- Published by Springer Nature in Research Square
Smart Computational Light Microscopes (SCLMs) of Smart Computational Imaging Laboratory (SCILab)
Computational microscopy, as a subfield of computational imaging, combines optical manipulation and image algorithmic reconstruction to recover multi-dimensional microscopic images or information of micro-objects. In recent years, the revolution in light-emitting diodes (LEDs), low-cost consumer image sensors, modern digital computers, and smartphones provide fertile opportunities for the rapid development of computational microscopy. Consequently, diverse forms of computational microscopy have been invented, including digital holographic microscopy (DHM), transport of intensity equation (TIE), differential phase contrast (DPC) microscopy, lens-free on-chip holography, and Fourier ptychographic microscopy (FPM). These computational microscopy techniques not only provide high-resolution, label-free, quantitative phase imaging capability but also decipher new and advanced biomedical research and industrial applications. Nevertheless, most computational microscopy techniques are still at an early stage of "proof of concept" or "proof of prototype" (based on commercially available microscope platforms). Translating those concepts to stand-alone optical instruments for practical use is an essential step for the promotion and adoption of computational microscopy by the wider bio-medicine, industry, and education community. In this paper, we present four smart computational light microscopes (SCLMs) developed by our laboratory, i.e., smart computational imaging laboratory (SCILab) of Nanjing University of Science and Technology (NJUST), China. These microscopes are empowered by advanced computational microscopy techniques, including digital holography, TIE, DPC, lensless holography, and FPM, which not only enables multi-modal contrast-enhanced observations for unstained specimens, but also can recover their three-dimensional profiles quantitatively. We introduce their basic principles, hardware configurations, reconstruction algorithms, and software design, quantify their imaging performance, and illustrate their typical applications for cell analysis, medical diagnosis, and microlens characterization.
- 12 June 2021
- Published by Springer Nature in Research Square
Open AccessSmart Computational Light Microscopes (SCLMs) of Smart Computational Imaging Laboratory (SCILab)
Computational microscopy, as a subfield of computational imaging, combines optical manipulation and image algorithmic reconstruction to recover multi-dimensional microscopic images or information of micro-objects. In recent years, the revolution in light-emitting diodes (LEDs), low-cost consumer image sensors, modern digital computers, and smartphones provide fertile opportunities for the rapid development of computational microscopy. Consequently, diverse forms of computational microscopy have been invented, including digital holographic microscopy (DHM), transport of intensity equation (TIE), differential phase contrast (DPC) microscopy, lens-free on-chip holography, and Fourier ptychographic microscopy (FPM). These computational microscopy techniques not only provide high-resolution, label-free, quantitative phase imaging capability but also decipher new and advanced biomedical research and industrial applications. Nevertheless, most computational microscopy techniques are still at an early stage of "proof of concept" or "proof of prototype" (based on commercially available microscope platforms). Translating those concepts to stand-alone optical instruments for practical use is an essential step for the promotion and adoption of computational microscopy by the wider bio-medicine, industry, and education community. In this paper, we present four smart computational light microscopes (SCLMs) developed by our laboratory, i.e., smart computational imaging laboratory (SCILab) of Nanjing University of Science and Technology (NJUST), China. These microscopes are empowered by advanced computational microscopy techniques, including digital holography, TIE, DPC, lensless holography, and FPM, which not only enables multi-modal contrast-enhanced observations for unstained specimens, but also can recover their three-dimensional profiles quantitatively. We introduce their basic principles, hardware configurations, reconstruction algorithms, and software design, quantify their imaging performance, and illustrate their typical applications for cell analysis, medical diagnosis, and microlens characterization.
- Open Access
- 1 December 2019
- Published by AIP Publishing in APL Photonics
- Vol. 4 (12) , 121301
Single-shot isotropic quantitative phase microscopy based on color-multiplexed differential phase contrast
We present a single-shot isotropic quantitative phase imaging method based on color-multiplexed differential phase contrast. In our method, the illumination source is modulated by an LCD into an annular color-multiplexed pattern matching the numerical aperture of the objective precisely to maximize the frequency response for both low and high frequencies (from 0 to ). In addition, we propose an alternating illumination scheme to provide a perfectly circularly symmetrical phase transfer function, achieving isotropic imaging resolution and signal-to-noise ratio. A color camera records the light transmitted through the specimen, and three monochromatic intensity images at each color channel are then separated and utilized to recover the phase of the specimen. We display the derivation, implementation, simulation and experimental results, which demonstrate that our method accomplishes high resolution, noise-robustness and reconstruction accuracy phase reconstruction at camera-limited frame rates.- 1 December 2019
- Published by AIP Publishing in APL Photonics
- Vol. 4 (12) , 121301
Open AccessSingle-shot isotropic quantitative phase microscopy based on color-multiplexed differential phase contrast
We present a single-shot isotropic quantitative phase imaging method based on color-multiplexed differential phase contrast. In our method, the illumination source is modulated by an LCD into an annular color-multiplexed pattern matching the numerical aperture of the objective precisely to maximize the frequency response for both low and high frequencies (from 0 to ). In addition, we propose an alternating illumination scheme to provide a perfectly circularly symmetrical phase transfer function, achieving isotropic imaging resolution and signal-to-noise ratio. A color camera records the light transmitted through the specimen, and three monochromatic intensity images at each color channel are then separated and utilized to recover the phase of the specimen. We display the derivation, implementation, simulation and experimental results, which demonstrate that our method accomplishes high resolution, noise-robustness and reconstruction accuracy phase reconstruction at camera-limited frame rates.