Zhanming Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhanming Fan has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Zhonghua Sun
Discipline of Medical Radiation Science, Curtin Medical School, Curtin University, Perth, Australia
8 shared publications - Lei Xu
Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China
6 shared publications Nan Zhang
Department of Radiology, Beijing Anzhen Hospital Capital Medical University, 2 Anzhen Road Beijing China 100029
5 shared publicationsDebiao Li
4 shared publicationsDongting Liu
Department of Radiology, Beijing Anzhen Hospital Capital Medical University, 2 Anzhen Road Beijing China 100029
4 shared publicationsJing An
4 shared publications
Latest Publications
- Open Access
- 22 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (15) , 4262
The Dynamic Characteristics of Myocardial Contractility and Extracellular Volume in Type 2 Diabetes Mellitus Mice Investigated by 7.0T Cardiac Magnetic Resonance
Type 2 diabetes mellitus (T2DM) is associated with a high prevalence of diastolic dysfunction and congestive heart failure. A potential contributing factor is the accelerated accumulation of diffuse myocardial fibrosis and stiffness. Novel cardiac magnetic resonance (CMR) imaging techniques can identify both myocardial fibrosis and contractility quantitatively. This study aimed to investigate the dynamic characteristics of the myocardial strain and altered extracellular volume (ECV) fraction as determined by 7.0 T CMR in T2DM mice. C57Bl/6J mice were randomly divided into T2DM (fed a high-fat diet) and control (fed a normal diet) groups. They were scanned on 7.0 T MRI every 4 weeks until the end of week 24. The CMR protocol included multi-slice cine imaging to assess left ventricle strain and strain rate, and pre- and post-contrast T1 mapping images to quantify ECV. The ECV in the T2DM mice was significantly higher (p < 0.05) than that in the control group since week 12 with significantly impaired myocardial strain (p < 0.05). A significant linear correlation was established between myocardial strain and ECV (p < 0.001) and left ventricular-ejection fraction and ECV (p = 0.003). The results suggested that CMR feature tracking-derived myocardial strain analysis can assess functional abnormalities that may be associated with ECM alterations in diabetic cardiomyopathy, contributing to the study of diabetic therapy effects.
- 22 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (15) , 4262
Open AccessThe Dynamic Characteristics of Myocardial Contractility and Extracellular Volume in Type 2 Diabetes Mellitus Mice Investigated by 7.0T Cardiac Magnetic Resonance
Type 2 diabetes mellitus (T2DM) is associated with a high prevalence of diastolic dysfunction and congestive heart failure. A potential contributing factor is the accelerated accumulation of diffuse myocardial fibrosis and stiffness. Novel cardiac magnetic resonance (CMR) imaging techniques can identify both myocardial fibrosis and contractility quantitatively. This study aimed to investigate the dynamic characteristics of the myocardial strain and altered extracellular volume (ECV) fraction as determined by 7.0 T CMR in T2DM mice. C57Bl/6J mice were randomly divided into T2DM (fed a high-fat diet) and control (fed a normal diet) groups. They were scanned on 7.0 T MRI every 4 weeks until the end of week 24. The CMR protocol included multi-slice cine imaging to assess left ventricle strain and strain rate, and pre- and post-contrast T1 mapping images to quantify ECV. The ECV in the T2DM mice was significantly higher (p < 0.05) than that in the control group since week 12 with significantly impaired myocardial strain (p < 0.05). A significant linear correlation was established between myocardial strain and ECV (p < 0.001) and left ventricular-ejection fraction and ECV (p = 0.003). The results suggested that CMR feature tracking-derived myocardial strain analysis can assess functional abnormalities that may be associated with ECM alterations in diabetic cardiomyopathy, contributing to the study of diabetic therapy effects.
- 18 April 2022
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 57 (1) , 167-177
Quantification of Early Diffuse Myocardial Fibrosis Through 7.0 T Cardiac Magnetic Resonance T1 Mapping in a Type 1 Diabetic Mellitus Mouse Model
Background Diffuse myocardial interstitial fibrosis (DMIF) is a key factor for heart failure (HF) in diabetic cardiomyopathy. MRI T1-mapping technique can quantitatively evaluate DMIF. Purpose To evaluate of early DMIF in a type 1 diabetes mellitus (T1DM) mouse model through 7.0 T MRI T1 mapping. Study Type Prospective. Animal Model A total of 50 8-week-old C57Bl/6J male mice were divided into control (n = 20) and T1DM (n = 30) groups. Field Strength/Sequence A 7.0 T small animal MRI; gradient echo Look-Locker inversion recovery T1-mapping sequence; cine MRI. Scans were acquired in control and T1DM mice every 4 weeks until 24 weeks. Assessment End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), left ventricle (LV) mass, fractional shortening (FS), and E/A ratio. They were evaluated through echocardiography and cine MRI. The extracellular volume fraction (ECV) was calculated. Sirius Red staining was performed and calculated collagen volume fraction (CVF). Statistical Tests Differences in ECV and CVF between two groups were analyzed using one-way analysis of variance. The correlation between ECV and CVF was assessed using Pearson's correlations. Results Compared with the control group, a progressive decrease in FS, EF, and E/A ratio was observed in the T1DM group. Both ECV and CVF values gradually increased during diabetes progression. A significant increase in ECV and CVF values was observed at 12 weeks (ECV: 32.5% +/- 1.6% vs. 28.1% +/- 1.8%; CVF: 6.9% +/- 1.8% vs. 3.3% +/- 1.1%). ECV showed a strong correlation with CVF (r = 0.856). Data Conclusion ECV is an accurate and feasible imaging marker that can be used to quantitatively assess DMIF changes over time in T1DM mice. ECV has potential to accurately detect DMIF in the early stage and may be a useful imaging tool to assess the need for early intervention in T1DM mice. Evidence Level 1 Technical Efficacy Stage 3.
- 18 April 2022
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 57 (1) , 167-177
Quantification of Early Diffuse Myocardial Fibrosis Through 7.0 T Cardiac Magnetic Resonance T1 Mapping in a Type 1 Diabetic Mellitus Mouse Model
Background Diffuse myocardial interstitial fibrosis (DMIF) is a key factor for heart failure (HF) in diabetic cardiomyopathy. MRI T1-mapping technique can quantitatively evaluate DMIF. Purpose To evaluate of early DMIF in a type 1 diabetes mellitus (T1DM) mouse model through 7.0 T MRI T1 mapping. Study Type Prospective. Animal Model A total of 50 8-week-old C57Bl/6J male mice were divided into control (n = 20) and T1DM (n = 30) groups. Field Strength/Sequence A 7.0 T small animal MRI; gradient echo Look-Locker inversion recovery T1-mapping sequence; cine MRI. Scans were acquired in control and T1DM mice every 4 weeks until 24 weeks. Assessment End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), left ventricle (LV) mass, fractional shortening (FS), and E/A ratio. They were evaluated through echocardiography and cine MRI. The extracellular volume fraction (ECV) was calculated. Sirius Red staining was performed and calculated collagen volume fraction (CVF). Statistical Tests Differences in ECV and CVF between two groups were analyzed using one-way analysis of variance. The correlation between ECV and CVF was assessed using Pearson's correlations. Results Compared with the control group, a progressive decrease in FS, EF, and E/A ratio was observed in the T1DM group. Both ECV and CVF values gradually increased during diabetes progression. A significant increase in ECV and CVF values was observed at 12 weeks (ECV: 32.5% +/- 1.6% vs. 28.1% +/- 1.8%; CVF: 6.9% +/- 1.8% vs. 3.3% +/- 1.1%). ECV showed a strong correlation with CVF (r = 0.856). Data Conclusion ECV is an accurate and feasible imaging marker that can be used to quantitatively assess DMIF changes over time in T1DM mice. ECV has potential to accurately detect DMIF in the early stage and may be a useful imaging tool to assess the need for early intervention in T1DM mice. Evidence Level 1 Technical Efficacy Stage 3.
- Open Access
- 3 December 2019
- Published by Wiley in Cardiology Research and Practice
- Vol. 2019, 1-8
Prediction Efficiency of Postoperative Acute Kidney Injury in Acute Stanford Type A Aortic Dissection Patients with Renal Resistive Index and Semiquantitative Color Doppler
Objectives. This study is aimed to evaluate the efficiency in early prediction of postoperative persistent acute kidney injury (PAKI) after surgery in acute Stanford type A aortic dissection (AAAD) patients by using Doppler renal resistive index (RRI) and semiquantitative color (SQC) Doppler grade, respectively. Methods. 84 AAAD patients received Sun’s surgical management, and 67 patients were enrolled. RRI and SQC Doppler grade were evaluated by ultrasonography, respectively, at 6 hours after surgery. Serum creatinine (sCr) was recorded before operation and at 24 hours, 48 hours, and 72 hours after operation. AKI grade was evaluated according to the classifications of the Acute Kidney Injury Network (AKIN). PAKI is defined as persistent oliguria and/or sCr elevation after 3 days. RRI and SQC Doppler grade were compared, respectively, between the PAKI and non-PAKI groups. Potential predictors were first tested by univariate logistic regression analysis, and a multivariate model was identified to determine the independent predictive ability of RRI and SQC Doppler grade for the PAKI. Receiver operating characteristic (ROC) analysis was performed to compare the diagnostic accuracy between RRI and SQC Doppler grade in early prediction of PAKI by using AKIN classifications as the reference standard. Results. Of a total of 67 patients enrolled during the study period, 21 (31.3%) patients suffered from PAKI and 8 (11.9%) patients required dialysis. There are significant differences in RRI (0.80 ± 0.09 vs. 0.70 ± 0.05, ) and SQC Doppler grade (, ) between the 2 groups with and without PAKI. Univariate analysis showed that RRI, SQC Doppler grade, length of stay in ICU, time of CPB, and length of stay in hospital were significant predictors of PAKI. RRI and the SQC Doppler grade remained independent predictors of PAKI. Area under the curve (AUC) of RRI was 0.855 (95% CI, 0.74–0.96) with cutoff value 0.725 (sensitivity 90.9% and specificity 71.1%), AUC of SQC Doppler grade was 0.642 (95% CI, 0.49–0.79) with cutoff value grade 2 (sensitivity 50% and specificity 73.3%). Conclusion. Both postoperative RRI and SQC Doppler grade are independent predictors for PAKI after surgery in AAAD patients. Both postoperative RRI and SQC Doppler grade can be obtained rapidly by bedside ultrasound, which is a good tool for early prediction for postoperative PAKI.- 3 December 2019
- Published by Wiley in Cardiology Research and Practice
- Vol. 2019, 1-8
Open AccessPrediction Efficiency of Postoperative Acute Kidney Injury in Acute Stanford Type A Aortic Dissection Patients with Renal Resistive Index and Semiquantitative Color Doppler
Objectives. This study is aimed to evaluate the efficiency in early prediction of postoperative persistent acute kidney injury (PAKI) after surgery in acute Stanford type A aortic dissection (AAAD) patients by using Doppler renal resistive index (RRI) and semiquantitative color (SQC) Doppler grade, respectively. Methods. 84 AAAD patients received Sun’s surgical management, and 67 patients were enrolled. RRI and SQC Doppler grade were evaluated by ultrasonography, respectively, at 6 hours after surgery. Serum creatinine (sCr) was recorded before operation and at 24 hours, 48 hours, and 72 hours after operation. AKI grade was evaluated according to the classifications of the Acute Kidney Injury Network (AKIN). PAKI is defined as persistent oliguria and/or sCr elevation after 3 days. RRI and SQC Doppler grade were compared, respectively, between the PAKI and non-PAKI groups. Potential predictors were first tested by univariate logistic regression analysis, and a multivariate model was identified to determine the independent predictive ability of RRI and SQC Doppler grade for the PAKI. Receiver operating characteristic (ROC) analysis was performed to compare the diagnostic accuracy between RRI and SQC Doppler grade in early prediction of PAKI by using AKIN classifications as the reference standard. Results. Of a total of 67 patients enrolled during the study period, 21 (31.3%) patients suffered from PAKI and 8 (11.9%) patients required dialysis. There are significant differences in RRI (0.80 ± 0.09 vs. 0.70 ± 0.05, ) and SQC Doppler grade (, ) between the 2 groups with and without PAKI. Univariate analysis showed that RRI, SQC Doppler grade, length of stay in ICU, time of CPB, and length of stay in hospital were significant predictors of PAKI. RRI and the SQC Doppler grade remained independent predictors of PAKI. Area under the curve (AUC) of RRI was 0.855 (95% CI, 0.74–0.96) with cutoff value 0.725 (sensitivity 90.9% and specificity 71.1%), AUC of SQC Doppler grade was 0.642 (95% CI, 0.49–0.79) with cutoff value grade 2 (sensitivity 50% and specificity 73.3%). Conclusion. Both postoperative RRI and SQC Doppler grade are independent predictors for PAKI after surgery in AAAD patients. Both postoperative RRI and SQC Doppler grade can be obtained rapidly by bedside ultrasound, which is a good tool for early prediction for postoperative PAKI. - 11 September 2019
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 34 (12) , 1642-1644
Giant primary cardiac synovial sarcoma of the right ventricle
- 11 September 2019
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 34 (12) , 1642-1644
Giant primary cardiac synovial sarcoma of the right ventricle
- Open Access
- 3 September 2018
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 9, 1181
Normal Values of Myocardial Deformation Assessed by Cardiovascular Magnetic Resonance Feature Tracking in a Healthy Chinese Population: A Multicenter Study
Reference values on atrial and ventricular strain from cardiovascular magnetic resonance (CMR) are essential in identifying patients with impaired atrial and ventricular function. However, reference values have not been established for Chinese subjects. One hundred and fifty healthy volunteers (75 Males/75 Females; 18–82 years) were recruited. All underwent CMR scans with images acceptable for further strain analysis. Subjects were stratified by age: Group 1, 18–44 years; Group 2, 45–59 years; Group 3, ≥60 years. Feature tracking of CMR cine imaging was used to obtain left atrial global longitudinal (LA Ell) and circumferential strains (LA Ecc) and respective systolic strain rates, left ventricular longitudinal (LV Ell), circumferential (LV Ecc) and radial strains (LV Err) and their respective strain rates, and right ventricular longitudinal strain (RV Ell) and strain rate. LA Ell and LA Ecc were 32.8 ± 9.2% and 40.3 ± 13.4%, respectively, and RV Ell was −29.3 ± 6.0%. LV Ell, LV Ecc and LV Err were −22.4 ± 2.9%, −24.3 ± 3.1%, and 79.0 ± 19.4%, respectively. LV Ell and LV Ecc were higher in females than males (P < 0.05). LA Ell, LA Ecc, and LV Ecc decreased, while LV Err increased with age (P < 0.05). LV Ell and RV Ell were not shown to be associated with age. Normal ranges for atrial and ventricular strain and strain rates are provided using CMR feature tracking in Chinese subjects.
- 3 September 2018
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 9, 1181
Open AccessNormal Values of Myocardial Deformation Assessed by Cardiovascular Magnetic Resonance Feature Tracking in a Healthy Chinese Population: A Multicenter Study
Reference values on atrial and ventricular strain from cardiovascular magnetic resonance (CMR) are essential in identifying patients with impaired atrial and ventricular function. However, reference values have not been established for Chinese subjects. One hundred and fifty healthy volunteers (75 Males/75 Females; 18–82 years) were recruited. All underwent CMR scans with images acceptable for further strain analysis. Subjects were stratified by age: Group 1, 18–44 years; Group 2, 45–59 years; Group 3, ≥60 years. Feature tracking of CMR cine imaging was used to obtain left atrial global longitudinal (LA Ell) and circumferential strains (LA Ecc) and respective systolic strain rates, left ventricular longitudinal (LV Ell), circumferential (LV Ecc) and radial strains (LV Err) and their respective strain rates, and right ventricular longitudinal strain (RV Ell) and strain rate. LA Ell and LA Ecc were 32.8 ± 9.2% and 40.3 ± 13.4%, respectively, and RV Ell was −29.3 ± 6.0%. LV Ell, LV Ecc and LV Err were −22.4 ± 2.9%, −24.3 ± 3.1%, and 79.0 ± 19.4%, respectively. LV Ell and LV Ecc were higher in females than males (P < 0.05). LA Ell, LA Ecc, and LV Ecc decreased, while LV Err increased with age (P < 0.05). LV Ell and RV Ell were not shown to be associated with age. Normal ranges for atrial and ventricular strain and strain rates are provided using CMR feature tracking in Chinese subjects.
- 1 March 2018
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 42 (2) , 277-281
A Preliminary Study of Computed Tomography Coronary Angiography Within a Single Cardiac Cycle in Patients With Atrial Fibrillation Using 256-Row Detector Computed Tomography
Objective: The purpose of this study was to evaluate the image quality and radiation dose of computed tomography (CT) coronary angiography using a 256-row detector CT scanner in a single cardiac cycle in patients with atrial fibrillation (AF). Methods: Seventy consecutive patients (41 men and 29 women; age range was from 37 to 84 years, mean age was 61.7 ± 10.2 years; body mass index range was from 15.08 to 36.45 kg/m2, mean body mass index was 25.9 ± 3.5 kg/m2) with persistent or paroxysmal AF during acquisition, who were not receiving any medications for heart rate (HR) regulation, were imaged with a 256-row detector CT scanner (Revolution CT, GE healthcare). According to the HR or HR variability (HRV) the patients were divided into 4 groups: group A (HR, ≥75 bpm; n = 36), group B (HR, P <0.05). Conclusions: This study shows that CT coronary angiography with use of a new 256-row detector CT in single cardiac cycle achieves diagnostic image quality but with lower radiation dose in patients with AF. Heart rate or HRV has no significant effect on image quality.
- 1 March 2018
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 42 (2) , 277-281
A Preliminary Study of Computed Tomography Coronary Angiography Within a Single Cardiac Cycle in Patients With Atrial Fibrillation Using 256-Row Detector Computed Tomography
Objective: The purpose of this study was to evaluate the image quality and radiation dose of computed tomography (CT) coronary angiography using a 256-row detector CT scanner in a single cardiac cycle in patients with atrial fibrillation (AF). Methods: Seventy consecutive patients (41 men and 29 women; age range was from 37 to 84 years, mean age was 61.7 ± 10.2 years; body mass index range was from 15.08 to 36.45 kg/m2, mean body mass index was 25.9 ± 3.5 kg/m2) with persistent or paroxysmal AF during acquisition, who were not receiving any medications for heart rate (HR) regulation, were imaged with a 256-row detector CT scanner (Revolution CT, GE healthcare). According to the HR or HR variability (HRV) the patients were divided into 4 groups: group A (HR, ≥75 bpm; n = 36), group B (HR, P <0.05). Conclusions: This study shows that CT coronary angiography with use of a new 256-row detector CT in single cardiac cycle achieves diagnostic image quality but with lower radiation dose in patients with AF. Heart rate or HRV has no significant effect on image quality.
- Open Access
- 1 February 2018
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 20 (1) , 1-8
Additive value of 3T cardiovascular magnetic resonance coronary angiography for detecting coronary artery disease
- 1 February 2018
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 20 (1) , 1-8
Open AccessAdditive value of 3T cardiovascular magnetic resonance coronary angiography for detecting coronary artery disease
- 1 February 2018
- Published by American Scientific Publishers in Journal of Medical Imaging and Health Informatics
- Vol. 8 (2) , 303-308
Patient-Specific 3D Printed Models of Renal Tumours Using Home-Made 3D Printer in Comparison with Commercial 3D Printer
The purpose of this study is to create three-dimensional (3D) printed models of renal tumours with use of homemade and commercially available 3D printers and compare the accuracy of 3D printed models in delineating renal tumours and costs associated with 3D printing between these 3D printers. Life-size 3D printed kidney models of two patients with suspected renal cell carcinoma were generated with use of high-resolution contrast-enhanced computed tomography (CT) images which were post-processed and segmented to show normal renal anatomy and renal tumours. Measurements of tumour diameters were performed at left to right and craniocaudal dimensions and were compared on 2D axial, multiplanar reformation (MPR) and 3D volume rendering CT images with those on 3D physical models to determine the accuracy differences between these techniques. 3D printed models were successfully generated by both commercial and home-made 3D printers with accurately replicating renal anatomy and renal tumours. Although there was no significant difference in measuring tumour diameters, measurements on 3D printed models between commercial and home-made 3D printers were within 0.9 mm in these two cases. Similarly, a good correlation was found in measurements made between 3D volume rendering images and 3D printed models with differences between 0.85 and 0.98 mm, 0.69 and 0.73 mm, for cases 1 and 2, respectively. Measurements in 3D printed models exceeded 2D axial and MPR measurements by an average of more than 1.5 mm. The printing cost per kidney model was US$1 and US$200 for home-made and commercial 3D printers, respectively. This study shows the feasibility of creating 3D printed models of demonstrating renal anatomy and renal tumours with use of home-made 3D printer with accuracy similar to that from commercial 3D printer, but at a much lower cost.
- 1 February 2018
- Published by American Scientific Publishers in Journal of Medical Imaging and Health Informatics
- Vol. 8 (2) , 303-308
Patient-Specific 3D Printed Models of Renal Tumours Using Home-Made 3D Printer in Comparison with Commercial 3D Printer
The purpose of this study is to create three-dimensional (3D) printed models of renal tumours with use of homemade and commercially available 3D printers and compare the accuracy of 3D printed models in delineating renal tumours and costs associated with 3D printing between these 3D printers. Life-size 3D printed kidney models of two patients with suspected renal cell carcinoma were generated with use of high-resolution contrast-enhanced computed tomography (CT) images which were post-processed and segmented to show normal renal anatomy and renal tumours. Measurements of tumour diameters were performed at left to right and craniocaudal dimensions and were compared on 2D axial, multiplanar reformation (MPR) and 3D volume rendering CT images with those on 3D physical models to determine the accuracy differences between these techniques. 3D printed models were successfully generated by both commercial and home-made 3D printers with accurately replicating renal anatomy and renal tumours. Although there was no significant difference in measuring tumour diameters, measurements on 3D printed models between commercial and home-made 3D printers were within 0.9 mm in these two cases. Similarly, a good correlation was found in measurements made between 3D volume rendering images and 3D printed models with differences between 0.85 and 0.98 mm, 0.69 and 0.73 mm, for cases 1 and 2, respectively. Measurements in 3D printed models exceeded 2D axial and MPR measurements by an average of more than 1.5 mm. The printing cost per kidney model was US$1 and US$200 for home-made and commercial 3D printers, respectively. This study shows the feasibility of creating 3D printed models of demonstrating renal anatomy and renal tumours with use of home-made 3D printer with accuracy similar to that from commercial 3D printer, but at a much lower cost.
- Retracted
- 6 June 2017
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 36 (10) , 2105-2111
Retracted: Early Detection of Postoperative Acute Kidney Injury in Acute Stanford Type A Aortic Dissection With Doppler Renal Resistive Index
Objectives: This study aimed to evaluate the early efficiency of Doppler renal resistive index (DRRI) in prediction of acute kidney injury (AKI) after surgery in acute Stanford Type A aortic dissection (AAAD) patients.Methods: Sixty‐one AAAD patients who planned to receive Sun's surgical management were prospectively enrolled. The DRRI was measured by ultrasonography Doppler on the day before surgery (DRRIpre), on admission to the intensive care unit (DRRIT0), 6 hours after surgery (DRRIT6), 24 hours after surgery (DRRIT24), and 48 hours after surgery (DRRIT48). The maximum DRRI value (DRRImax) was recorded. The AKI was evaluated according to the classifications of the Acute Kidney Injury Network. The DRRI and serum creatinine (sCr) were compared between the pre‐ and postoperative time stations, as well as between the AKI and no‐AKI groups.Results: Thirty‐nine (63.9%) patients suffered from AKI, and 12 (19.6%) patients received dialysis. No significant difference was found in DRRIpre (0.63 ± 0.04 versus 0.65 ± 0.06, P = .059) and sCrpre (84.13 ± 23.77 versus 94.29 ± 51.11, P = .383) between the two groups with and without AKI. Both the DRRI and sCr increased significantly after surgery in the AKI groups (P < .001). However, the DRRI reached its maximum 6 hours after surgery, whereas the sCr reached its maximum after 24 hours. Both the DRRI and sCr improved 48 hours after surgery. The area under the receiver operating characteristic curve for DRRImax (0.864, 95% confidence interval: 0.770–0.957) and DRRIT6 (0.861, 95% confidence interval: 0.766‐0.957) was larger than the other three DRRIs measured at different time points. The cutoff value of DRRImax was 0.71, a sensitivity of 76.9% and specificity of 95.5%.Conclusions: Postoperative DRRI predicts the AKI earlier than sCr after AAAD surgery. The best time to detect DRRI was 6 hours after surgery.
- 6 June 2017
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 36 (10) , 2105-2111
RetractedRetracted: Early Detection of Postoperative Acute Kidney Injury in Acute Stanford Type A Aortic Dissection With Doppler Renal Resistive Index
Objectives: This study aimed to evaluate the early efficiency of Doppler renal resistive index (DRRI) in prediction of acute kidney injury (AKI) after surgery in acute Stanford Type A aortic dissection (AAAD) patients.Methods: Sixty‐one AAAD patients who planned to receive Sun's surgical management were prospectively enrolled. The DRRI was measured by ultrasonography Doppler on the day before surgery (DRRIpre), on admission to the intensive care unit (DRRIT0), 6 hours after surgery (DRRIT6), 24 hours after surgery (DRRIT24), and 48 hours after surgery (DRRIT48). The maximum DRRI value (DRRImax) was recorded. The AKI was evaluated according to the classifications of the Acute Kidney Injury Network. The DRRI and serum creatinine (sCr) were compared between the pre‐ and postoperative time stations, as well as between the AKI and no‐AKI groups.Results: Thirty‐nine (63.9%) patients suffered from AKI, and 12 (19.6%) patients received dialysis. No significant difference was found in DRRIpre (0.63 ± 0.04 versus 0.65 ± 0.06, P = .059) and sCrpre (84.13 ± 23.77 versus 94.29 ± 51.11, P = .383) between the two groups with and without AKI. Both the DRRI and sCr increased significantly after surgery in the AKI groups (P < .001). However, the DRRI reached its maximum 6 hours after surgery, whereas the sCr reached its maximum after 24 hours. Both the DRRI and sCr improved 48 hours after surgery. The area under the receiver operating characteristic curve for DRRImax (0.864, 95% confidence interval: 0.770–0.957) and DRRIT6 (0.861, 95% confidence interval: 0.766‐0.957) was larger than the other three DRRIs measured at different time points. The cutoff value of DRRImax was 0.71, a sensitivity of 76.9% and specificity of 95.5%.Conclusions: Postoperative DRRI predicts the AKI earlier than sCr after AAAD surgery. The best time to detect DRRI was 6 hours after surgery.
- 1 June 2017
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 283 (3) , 923
Diagnostic Performance of Self-navigated Whole-Heart Contrast-enhanced Coronary 3-T MR Angiography
- 1 June 2017
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 283 (3) , 923
Diagnostic Performance of Self-navigated Whole-Heart Contrast-enhanced Coronary 3-T MR Angiography