NMN. Stewart McIntyre

N. Stewart McIntyre

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


N. Stewart McIntyre has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Enhancing Oxygen Spectra Interpretation by Calculating Oxygen Linked to Adventitious Carbon

    by J. D. Henderson, B. P. Payne, N. S. McIntyre, M. C. Biesinger

    The presence of adventitious carbon on samples analysed by X‐ray photoelectron spectroscopy can complicate data interpretation. Because adventitious carbon can contain a significant amount of oxygen‐containing functional groups, accounting for its contribution is essential when analysing oxygen. For example, accurately determining the oxygen concentration—free from adventitious carbon contributions—is often crucial for some data interpretation. Additionally, when modelling high‐resolution oxygen 1s spectra, the organic oxygen must be considered to ensure accurate interpretation. Although these aspects of data interpretation should ideally be guided by stoichiometry, the process can be tedious and challenging, particularly for novice users. This Insight Note introduces a method for accounting for organic oxygen associated with adventitious carbon. It provides background information, outlines key assumptions and includes an easy‐to‐use Excel calculator to support this analysis, making the approach more accessible, especially for novice users.


  • Foreword

    by Heng‐Yong Nie, N. Stewart McIntyre

  • Mapping of changes in microscopic strain in Alloy 600 during multi‐step applications of mechanical stress

    by J. Ulaganathan, A. G. Carcea, R. C. Newman, R. I. Barabash, N. S. McIntyre

    An Alloy 600 C‐ring has been sequentially stressed as in a classical deformation test, and the apex of the C‐ring has been spatially mapped by Laue microdiffraction during the stress deflection sequence. The diffraction spots were analyzed to provide maps showing the distributions of deviatoric elastic deformations as they changed with increased stress. The Laue‐derived elastic strains in the stress direction, averaged over small areas at the C‐ring apex responded to stress in a classic manner expected of a system undergoing elastic and then plastic deformation. For small amounts of applied stress, maps of the strain tensor in the stress direction (ε xx ) showed distributions that were reasonably homogeneous. As applied stress was increased to the elastic limit, distinct local pockets of the tensile strain tensor (ε xx ) became apparent. As stress approached a maximum deformation of 10 times the elastic limit, the strain tensor distribution underwent further changes. Von Mises elastic strains were also mapped and, in general, appeared to reduce as stress is increased. The formation and distribution of geometrically necessary dislocations were also monitored. After annealing at 315 C, the ε xx strain tensor values were diminished from most areas excepting those bordering some grain boundaries. Strain changes in stressed Alloy 600 C‐rings were also studied following two brief stages of accelerated aqueous corrosion at 315 C. Localized ε xx strain tensor and von Mises strain values gradually diminished except for areas near grain boundaries. Copyright © 2017 John Wiley & Sons, Ltd.


  • X‐ray photoelectron study of oxides formed on Ni metal and Ni‐Cr alloy surfaces under electrochemical control at 25 °C and 150 °C

    by B. P. Payne, P. G. Keech, N. S. McIntyre

    The oxide chemical composition on metallic Ni and NiCr alloy electrodes has been studied for changes in simulated reactor coolant solution chemistry, through a range of oxidizing potentials and pH settings at 25 °C and 150 °C. Even under strongly reducing conditions, the Ni surface has a 2‐nm layer of oxide and hydroxide from which further oxides form, depending on the subsequent oxidative step. For basic (normal operating) pH conditions and under oxidation potentials near 0 volts (vs. SCE), a predominantly Ni(OH) 2 layer is formed that appears to remain relatively stable up to at least 48 hours of oxidation at 150 °C. For the NiCr alloy, similar stability is imparted by a thin film of Cr(OH) 3 / Cr 2 O 3 and Ni(OH) 2 ./NiO. Under milder oxidizing (but still basic) conditions, the surface is stabilized by a thin film that is mostly Ni(OH) 2 /NiO. Under neutral solution conditions, the same oxide/ hydroxide films do not seem to be as effective in stabilizing the surface. Copyright © 2017 John Wiley & Sons, Ltd.


  • A spectroscopic study of leak failures in cross‐linked polyethylene tubing used in domestic water supply systems

    by Mary Jane Walzak, N. Stewart McIntyre, O. Manuel Uy

    Recent leak failures in cross‐linked polyethylene tubing from several US locations have been studied using microscopy and microscopic spectroscopy. Such failures compromise the use of a material that has been regarded as more environmentally sustainable. The failures appear to be the result of local chemical attack by aqueous chlorine that reacts with the polymer, leading to its oxidation, decrystallization and expansion of its volume. This creates stress fields that lead to chemically induced cracking of the polymer and, eventually, failure of the tubing. Each failure studied in this work was found to be associated with a micro‐protrusion in the inside diameter of the tubes; it is proposed that turbulence in the water flow behind the protrusion may accelerate local mechanical and chemical attack of the polyethylene tubing. A simple inspection method is suggested to detect the presence of such protrusions before installation of the tubing. Copyright © 2017 John Wiley & Sons, Ltd.


  • Microscopic Cracking on Flat Alloy 600 Surfaces Following Accelerated Caustic Corrosion: Mapping of Strains and Microstructure During the Corrosion Process

    by N.S. McIntyre, J. Ulaganathan, T. Simpson, J. Qin, N. Sherry, A.G. Carcea, R.C. Newman, M. Kunz, N. Tamura

    Microscopic distributions of elastic and plastic strains have been studied at three intervals during an electrochemically accelerated corrosion test of a flat, polished surface of a mill-annealed and unstrained sample of Alloy 600 (UNS N06600) in 10% sodium hydroxide (NaOH) at 315°C. Laue microdiffraction was used with a micron-sized polychromatic (white) x-ray beam to map strain changes in the sample as a function of corrosion time. After two 12 h corrosion periods, tensile elastic strains were detected along a grain boundary. After a third 24 h corrosion period, this particular boundary was found to have cracked to a depth of several microns; other adjacent boundaries exhibited tensile elastic strain, but no cracking. No significant changes to plastic strain distributions in the same area could be detected as a function of corrosion exposure.


  • Mapping of Microscopic Strain Distributions in an Alloy 600 C-Ring After Application of Hoop Stresses and Stress Corrosion Cracking

    by N.S. McIntyre, J. Ulaganathan, T. Simpson, J. Qin, N. Sherry, M. Bauer, A.G. Carcea, R.C. Newman, M. Kunz, N. Tamura

    Laue diffraction measurements made using polychromatic synchrotron x-radiation have revealed significant changes to the microscopic strain distributions in an Alloy 600 (UNS N06600) tube following the application of a circumferential (hoop) stress and then as a result of stress corrosion cracking (SCC). The changes in the elastic and plastic strain distributions were studied for the same area near the outer diameter of the tube prepared as a C-ring. Following the application of the circumferential stress, there was a notable loss of crystal order within the outermost 3 μm to 5 μm of the tube surface as a result of plastic processes; further into the sample the elastic strains in grain boundaries become oriented toward the direction of the impressed stress. The average intensity of oriented tensile strain is 5×10−3 within the outermost 50 μm of the C-ring. After corrosion, the elastic strain distribution in the same region becomes slightly compressive. The strains associated with a network of fine incipient cracks on the outside diameter of the C-ring were explored; elastic compressive strains were found within few micrometers from the crack center presumably as a result of crack opening, while plastic deformation was limited to the immediate crack region.


  • Gas Phase Initial Oxidation of Incoloy 800 Surfaces

    by Michael W. Edwards, N. Stewart McIntyre


  • Remote Internet Access to Advanced Analytical Facilities: A New Approach with Web-Based Services

    by N. Sherry, J. Qin, M. Suominen Fuller, Y. Xie, O. Mola, M. Bauer, N. S. McIntyre, D. Maxwell, D. Liu, E. Matias, et al.

    Over the past decade, the increasing availability of the World Wide Web has held out the possibility that the efficiency of scientific measurements could be enhanced in cases where experiments were being conducted at distant facilities. Examples of early successes have included X-ray diffraction (XRD) experimental measurements of protein crystal structures at synchrotrons and access to scanning electron microscopy (SEM) and NMR facilities by users from institutions that do not possess such advanced capabilities. Experimental control, visual contact, and receipt of results has used some form of X forwarding and/or VNC (virtual network computing) software that transfers the screen image of a server at the experimental site to that of the users’ home site. A more recent development is a web services platform called Science Studio that provides teams of scientists with secure links to experiments at one or more advanced research facilities. The software provides a widely distributed team with a set of controls and screens to operate, observe, and record essential parts of the experiment. As well, Science Studio provides high speed network access to computing resources to process the large data sets that are often involved in complex experiments. The simple web browser and the rapid transfer of experimental data to a processing site allow efficient use of the facility and assist decision making during the acquisition of the experimental results. The software provides users with a comprehensive overview and record of all parts of the experimental process. A prototype network is described involving X-ray beamlines at two different synchrotrons and an SEM facility. An online parallel processing facility has been developed that analyzes the data in near-real time using stream processing. Science Studio and can be expanded to include many other analytical applications, providing teams of users with rapid access to processed results along with the means for detailed discussion of their significance.