Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Miguel Aller Pellitero has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Revealing the impact of temperature on electrochemical, DNA-based sensors to correct signaling fluctuations

    by Miguel Aller Pellitero, Patrick Severin Sfragano, Noemí De-Los-Santos-Álvarez, María Jesús Lobo-Castañón


  • Open Access

    Microneedles for Continuous, Minimally Invasive Monitoring: A Technology Overview

    by Guillermo Conejo‐Cuevas, Miguel Aller Pellitero, Leire Ruiz‐Rubio, Francisco Javier del Campo

    Microneedles are small piercing structures, with sizes in the micron‐to‐millimeter range, designed to penetrate painlessly the outer skin layer, known as stratum corneum, providing minimally invasive access to interstitial fluid (ISF), which enables the monitoring of biochemical parameters in real‐time. This review covers recent progress to date in the area of electrochemical sensing using microneedles, and provides an overview of fabrication materials and processes, as well as applications. The main body of the review focuses on the fabrication of microneedle structures and their transformation into electrochemical biosensors for continuous monitoring. To this end, the main recognition elements and electrode functionalization ways are described, paying closer attention to aptamers and continuous aptamer‐based sensing, whose importance, merits, and limitations are highlighted. In addition to covering the main current applications, the review discusses the future threats and opportunities of microneedle‐based in vivo monitoring.


  • Open Access

    Revealing the impact of temperature on electrochemical, DNA-based sensors to correct signaling fluctuations

    by Miguel Aller Pellitero, Patrick Severin-Safragano, Noemí De-Los-Santos-Álvarez, María Jesús Lobo-Castañón

    Developing convenient and easy-to-use analysis tools for real-world applications requires sensing approaches that enable rapid, reagentless, and in situ quantitation of diverse molecular targets. Electrochemical, DNA-based (E-DNA) sensors meet these needs by utilizing conformational changes in electrode-bound, redox reporter-modified DNA probes upon target binding. The recognition event alters the electron transfer rate from the redox reporter, which can be monitored using square wave voltammetry by synchronizing the excitation frequency with the charge transfer rate. However, the kinetic nature of the surface-bound sensing process makes signaling strongly temperature-dependent, an aspect that has been widely overlooked and that restricts the application of E-DNA sensors to temperature-controlled environments. Here, we explore the relationship between electrochemical signal, square wave frequency, and temperature across different DNA constructs. Doing so, we identified the architectures most susceptible to temperature-induced signal fluctuations and developed two straightforward correction strategies. These approaches are particularly effective for electrochemical, aptamer-based (E-AB) sensors, enabling accurate and stable measurements over a wide temperature range, from 22 ºC to 37 ºC. By eliminating the significant influence of temperature on signaling, we broaden the applicability of E-DNA sensors, enhancing their performance for point-of-care testing, continuous molecular monitoring, and other real-world scenarios where temperature fluctuations are unavoidable.

  • Open Access

    Stability of N-Heterocyclic Carbene Monolayers under Continuous Voltammetric Interrogation

    by Miguel Aller Pellitero, Isabel M. Jensen, Nathaniel L. Dominique, Lilian Chinenye Ekowo, Jon P. Camden, David M. Jenkins, Netzahualcóyotl Arroyo-Currás

    N-Heterocyclic carbenes (NHCs) are promising monolayer-forming ligands that can overcome limitations of thiol-based monolayers in terms of stability, surface functionality, and reactivity across a variety of transition-metal surfaces. Recent publications have reported the ability of NHCs to support biomolecular receptors on gold substrates for sensing applications and improved tolerance to prolonged biofluid exposure relative to thiols. However, important questions remain regarding the stability of these monolayers when subjected to voltage perturbations, which is needed for applications with electrochemical platforms. Here, we investigate the ability of two NHCs, 1,3-diisopropylbenzimidazole and 5-(ethoxycarbonyl)-1,3-diisopropylbenzimidazole, to form monolayers via self-assembly from methanolic solutions of their trifluoromethanesulfonate salts. We compare the electrochemical behavior of the resulting monolayers relative to that of benchmark mercaptohexanol monolayers in phosphate-buffered saline. Within the -0.15 to 0.25 V vs Ag|AgCl voltage window, NHC monolayers are stable on gold surfaces, wherein they electrochemically perform like thiol-based monolayers and undergo similar reorganization kinetics, displaying long-term stability under incubation in buffered media and under continuous voltammetric interrogation. At negative voltages, NHC monolayers cathodically desorb from the electrode surface at lower bias (-0.1 V) than thiol-based monolayers (-0.5 V). At voltages more positive than 0.25 V, NHC monolayers anodically desorb from electrode surfaces at similar voltages to thiol-based monolayers. These results highlight new limitations to NHC monolayer stability imposed by electrochemical interrogation of the underlying gold electrodes. Our results serve as a framework for future optimization of NHC monolayers on gold for electrochemical applications, as well as structure-functionality studies of NHCs on gold.


  • Open Access

    Os(ii/iii) complex supports pH-insensitive electrochemical DNA-based sensing with superior operational stability than the benchmark methylene blue reporter

    by Miguel Aller Pellitero, Nandini Kundu, Jonathan Sczepanski, Netzahualcóyotl Arroyo-Currás

    This study reports an osmium-based redox reporter that enables pH-insensitive and fast DNA-based molecular sensing, offering new possibilities for the study of short-lived dynamic molecular events.


  • Open Access

    Optimization of Vancomycin Aptamer Sequence Length Increases the Sensitivity of Electrochemical, Aptamer-Based Sensors In Vivo

    by Alexander Shaver, J.D. Mahlum, Karen Scida, Melanie L. Johnston, Miguel Aller Pellitero, Yao Wu, Gregory V. Carr, Netzahualcóyotl Arroyo-Currás

    The measurement of serum vancomycin levels at the clinic is critical to optimizing dosing given the narrow therapeutic window of this antibiotic. Current approaches to quantitate serum vancomycin levels are based on immunoassays, which are multistep methods requiring extensive processing of patient samples. As an alternative, vancomycin-binding electrochemical, aptamer-based sensors (E-ABs) were developed to simplify the workflow of vancomycin monitoring. E-ABs enable the instantaneous measurement of serum vancomycin concentrations without the need for sample dilution or other processing steps. However, the originally reported vancomycin-binding E-ABs had a dissociation constant of 45 μM, which is approximately 1 order of magnitude higher than the recommended trough concentrations of vancomycin measured in patients. This limited sensitivity hinders the ability of E-ABs to accurately support vancomycin monitoring. To overcome this problem, here we sought to optimize the length of the vancomycin-binding aptamer sequence to enable a broader dynamic range in the E-AB platform. Our results demonstrate, via isothermal calorimetry and E-AB calibrations in undiluted serum, that superior affinity and near-equal sensor gain in vitro can be achieved using a one-base-pair-longer aptamer than the truncated sequence originally reported. We validate the impact of the improved binding affinity in vivo by monitoring vancomycin levels in the brain cortex of live mice following intravenous administration. While the original sequence fails to resolve vancomycin concentrations from baseline noise (SNR = 1.03), our newly reported sequence provides an SNR of 1.62 at the same dose.


  • Open Access

    Antibody–Invertase Fusion Protein Enables Quantitative Detection of SARS-CoV-2 Antibodies Using Widely Available Glucometers

    by Elissa K. Leonard, Miguel Aller Pellitero, Boris Juelg, Jamie B. Spangler, Netzahualcóyotl Arroyo-Currás

    Rapid diagnostics that can accurately inform patients of disease risk and protection are critical to mitigating the spread of the current COVID-19 pandemic and future infectious disease outbreaks. To be effective, such diagnostics must rely on simple, cost-effective, and widely available equipment and should be compatible with existing telehealth infrastructure to facilitate data access and remote care. Commercial glucometers are an established detection technology that can overcome the cost, time, and trained personnel requirements of current benchtop-based antibody serology assays when paired with reporter molecules that catalyze glucose conversion. To this end, we developed an enzymatic reporter that, when bound to disease-specific patient antibodies, produces glucose in proportion to the level of antibodies present in the patient sample. Although a straightforward concept, the coupling of enzymatic reporters to secondary antibodies or antigens often results in low yields, indeterminant stoichiometry, reduced target binding, and poor catalytic efficiency. Our enzymatic reporter is a novel fusion protein that comprises an antihuman immunoglobulin G (IgG) antibody genetically fused to two invertase molecules. The resulting fusion protein retains the binding affinity and catalytic activity of the constituent proteins and serves as an accurate reporter for immunoassays. Using this fusion, we demonstrate quantitative glucometer-based measurement of anti-SARS-CoV-2 spike protein antibodies in blinded clinical sample training sets. Our results demonstrate the ability to detect SARS-CoV-2-specific IgGs in patient serum with precise agreement to benchmark commercial immunoassays. Because our fusion protein binds all human IgG isotypes, it represents a versatile tool for detection of disease-specific antibodies in a broad range of biomedical applications.


  • Open Access

    Study of surface modification strategies to create glassy carbon-supported, aptamer-based sensors for continuous molecular monitoring

    by Miguel Aller Pellitero, Netzahualcóyotl Arroyo-Currás

    Electrochemical, aptamer-based (E-AB) sensors uniquely enable reagentless, reversible, and continuous molecular monitoring in biological fluids. Because of this ability, E-AB sensors have been proposed for therapeutic drug monitoring. However, to achieve translation from the bench to the clinic, E-AB sensors should ideally operate reliably and continuously for periods of days. Instead, because these sensors are typically fabricated on gold surfaces via self-assembly of alkanethiols that are prone to desorption from electrode surfaces, they undergo significant signal losses in just hours. To overcome this problem, our group is attempting to migrate E-AB sensor interfaces away from thiol-on-gold assembly towards stronger covalent bonds. Here, we explore the modification of carbon electrodes as an alternative substrate for E-AB sensors. We investigated three strategies to functionalize carbon surfaces: (I) anodization to generate surface carboxylic groups, (II) electrografting of arenediazonium ions, and (III) electrografting of primary aliphatic amines. Our results indicate that electrografting of primary aliphatic amines is the only strategy achieving monolayer organization and packing densities closely comparable to those obtained by alkanethiols on gold. In addition, the resulting monolayers enable covalent tethering of DNA aptamers and support electrochemical sensing of small molecule targets or complimentary DNA strands. These monolayers also achieve superior stability under continuous voltammetric interrogation in biological fluids relative to benchmark thiol-on-gold monolayers when a positive voltage scan window is used. Based on these results, we postulate the electrografting of primary aliphatic amines as a path forward to develop carbon-supported E-AB sensors with increased operational stability. Graphical abstract


  • Nanoscale Bioreceptor Layers Comprising Carboxylated Polythiophene for Organic Electrochemical Transistor-Based Biosensors

    by Yunjia Song, Zachary D. Lamberty, Junhao Liang, Miguel Aller Pellitero, Justine S. Wagner, Eugenie Jumai’aN, Michael A. Bevan, Joelle Frechette, Netzahualcóyotl Arroyo-Currás, Howard E. Katz