FMFariba Motevasselian

Fariba Motevasselian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fariba Motevasselian has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Poly(Alkenoic Acids) Molecular Weight on Microshear Bond Strength of Glass Ionomer Cement to Dentin

    by Faraz Khodakarami, Mohammad Atai, Zahra Shahidi, Fariba Motevasselian

    Objective: To assess the influence of poly(alkenoic acids) (PAA) molecular weight (MW) on the microshear bond strength (µSBS) of conventional glass ionomer cements (GICs) to dentin. Materials and Methods: Twenty‐four third molars were sectioned mesiodistally to expose flat buccal halves and randomly divided into four main groups. Three PAA solutions were synthesized with different MWs: (i) high molecular weight (HMW: Mw = 46,300 Da), (ii) low molecular weight (LMW: Mw = 15,700 Da), and (iii) mixed molecular weight (MixMW: 1:1 mixture of HMW and LMW polymers). The PAA solutions were hand‐mixed with a commercial GIC restorative powder (Fuji II, GC Corp., Tokyo, Japan) at a powder‐to‐liquid ratio of 1.5:1 (wt/wt). Each tooth specimen received microcylinders at the mesiobuccal and distobuccal line angles from the four tested materials, including the control group and the experimental groups. µSBS was tested after subjecting the specimens to thermocycling (5000 cycles; 5–55°C) using a universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed using a one‐way ANOVA test ( p < 0.05). Failure modes were assessed using a stereomicroscope at 40× magnification. Result: There was a significant difference between the groups. There was a significant difference between the groups. The mixture of PAA containing both HMW and LMW exhibited higher µSBS values compared with both the HMW group and the control group. Mixed failures were the most common, while adhesive failures occurred least frequently among the experimental groups. Conclusion: The selected mixed ionomers of different MWs had a statistically significant effect on the µSBS of GIC to dentin.


  • Open Access

    Conservative Management of Uneven Anterior Teeth Spacing using Lingual Porcelain Laminate Veneers: Report of Two Cases with 2- and 6-year follow-up

    by Hamid Kermanshah, Fariba Motevasselian, Zahra Amiri, Fateme Baghbani

    Porcelain laminate veneers (PLV) offer a conservative aesthetic solution for interdental space closure. However, space is typically not distributed symmetrically, and the mesiodistal width of the restored teeth may increase unless multiple teeth are prepared for conventional PLV to maintain appropriate individual tooth proportion. Ceramic fragments can be suggested to close the space without modifying tooth size and dental proportion. This article presents two cases where interdental gaps were closed using lingually placed porcelain laminate (LPPL). All stages of the restorative procedures, including treatment planning, temporization, tooth preparation, and cementation of these delicate restorations, are detailed. Based on the results of these clinical reports, we regard the use of LPPL as a successful treatment option in selected cases, as evidenced by 2- and 6-year follow-ups. The Modified United State Public Health Criteria is reported.


  • Open Access

    Effect of pH of In-Office Bleaching Gels and Timing of Fluoride Gel Application on Microhardness and Surface Morphology of Enamel

    by Fariba Motevasselian, Hamid Kermanshah, Dorara Dortaj, Frank Lippert

    Objective. To assess microhardness (VH) of enamel treated with two in-office bleaching agents with different pH and to study the effect of post- and prebleaching fluoride therapy. Materials and Methods. Eighty bovine incisors were divided into eight groups: G1-Unbleached group; G2-2 NaF; G3-Pola Office (pH3.8); G4-Pola Office (pH7); G5-Pola Office followed by 2 NaF; G6-2 NaF followed by Pola Office; G7-Pola Office followed by 2 NaF; G8-2 NaF followed by Pola Office. Bleaching was conducted 3x with 1-week intervals (T1/T7/T14). Specimens were kept in artificial saliva. VH was measured at T1, T7, and T14. Data were analyzed using repeated measure ANOVA. Surface morphology was assessed using scanning electron microscopy. Result. There was no significant difference among the groups at T1. No significant difference was found between G3 and G4 at all intervals. 2 NaF (G5/G6 vs. G3) significantly prevented softening at T7 and T14. Some nonsignificant hardening was observed for 2 NaF for G7/G8 vs. G4. At T14, G3 showed the lowest VH values. G5 showed higher VH values compared to other groups apart from G6G7. No relationship between bleaching protocols and surface morphology was observed. Conclusion. Pola Office caused the most softening. 2 NaF gel application after Pola Office bleaching was effective in recovering enamel hardness. Fluoride application after Pola Office bleaching provided little benefit.


  • The role of lead and cadmium in deciduous teeth and saliva on dental caries in children residing in Tehran, Iran

    by Fariba Motevasselian, Khosro Abdi, Hoda Ghodarati, Ahmad Reza Shamshiri, Frank Lippert, Hossein Hessari


  • Effect of Photobiomodulation Therapy with 915 nm Diode Laser on Pain Perception during Local Anesthesia of Maxillary Incisors: A Randomized Controlled Trial

    by Hamid Kermanshah, Nasim Chiniforush, Mahsa Kolahdouz Mohammadi, Fariba Motevasselian

    This study aimed to evaluate the effect of photobiomodulation therapy (PBMT) with 915 nm wavelength on pain reduction during maxillary incisors' local infiltration in a randomized clinical trial study. A prospective triple‐blinded split‐mouth clinical trial was designed to assess pain perception during needle insertion and local anesthetic injection in 32 healthy patients required operative caries management on contralateral maxillary incisors. After laser treatment (915 nm, power of 1.5 W, duty cycle of 60% and energy density of 72 J cm−2) in active group and no irradiation in sham group, the injection was performed. Patients’ perception of pain was immediately assessed using numerical rating scale (NRS) for pain. Washout period between two appointments was one week. Wilcoxon signed‐rank and Pearson correlation statistical analyses were used to assess the comparison of pain score between two appointments and the effect of anxiety level of previous dental injections. The mean scores of pain for the active laser and sham laser groups were 2.5 ± 2.19 and 4.34 ± 2.52, respectively, with a statistically significant higher NRS in the sham laser group (P ˂ 0.05). In this study's condition, diode PBMT reduced pain during infiltration on maxillary incisors. Anxiety experience of dental injection had no significant effect on pain perception scale (P ˃ 0.05).


  • Open Access

    Comparison of microleakage of an alkasite restorative material, a composite resin and a resin-modified glass ionomer

    by Fariba Motevasselian, Hamid Kermanshah, Ebrahim Rasoulkhani, Mutlu Özcan

    Aim: To compare the microleakage of Cention N, a subgroup of composite resins with a resin-modified glass ionomer (RMGI) and a composite resin. Methods: Class V cavities were prepared on the buccal and lingual surfaces of 46 extracted human molars. The teeth were randomly assigned to four groups. Group A: Tetric N-Bond etch-and-rinse adhesive and Tetric N-Ceram nanohybrid composite resin, group B: Cention N without adhesive, group C: Cention N with adhesive, and group D: Fuji II LC RMGI. The teeth were thermocycled between 5°-55°C (×10,000). The teeth were coated with two layers of nail vanish except for 1 mm around the restoration margins, and immersed in 2% methylene blue (37°C, 24 h) before buccolingual sectioning to evaluate dye penetration under a stereomicroscope (×20). The data were analyzed by the Kruskal-Wallis and Wilcoxon tests (α=0.05). Results: Type of material and restoration margin had significant effects on the microleakage (p<0.05). Dentin margins showed a higher leakage score in all groups. Cention N and RMGI groups showed significant differences at the enamel margin (p=0.025, p=0.011), and for the latter group the scores were higher. No significant difference was found at the dentin margins between the materials except between Cention N with adhesive and RMGI (p=0.031). Conclusion: Microleakage was evident in all three restorative materials. Cention N groups showed similar microleakage scores to the composite resin and displayed lower microleakage scores compared with RMGI.


  • Open Access

    Effect of ceramic material type on the fracture load of inlay-retained and full-coverage fixed dental prostheses

    by Hamid Kermanshah, Fariba Motevasselian, Saeedeh Alavi Kakhaki, Mutlu Özcan

    Objective: Ceramic inlay-retained fixed partial denture (IRFPD) is a conservative prosthetic option but the mechanical durability of new high strength zirconia reinforced glass ceramic FPDs is not investigated. The purpose of this study was to compare fracture load of 3-unit ceramic FPDs. Materials and methods: Extracted premolars and molars (N = 64) were used to create three test groups (IRFPDs) and one control group (full coverage FPD) (n = 8). The teeth were embedded in PMMA resin with a mesiodistal distance of 6 mm. Premolars had a distal and molars had a mesial inlay preparation (width: 3 mm; height: 4 mm) in the test groups. IRFPDs were made from a zirconia reinforced lithium silicate (VS) or a monolithic zirconia. Zirconia IRFPDs received 2 types of surface treatments: sandblasting (Zr-IRFPD) or internal coating with feldspathic porcelain (ZrC-IRFPD). Control group was made from monolithic zirconia with the same connector size and zirconia surfaces were sandblasted (Zr-FPD). All restorations were cemented using a resin luting cement. After 5000 thermo-cycles, fracture load values (N) were determined with a universal testing machine at a crosshead speed of 0.75 mm/min. Data were analyzed using 1-way ANOVA and Tukey`s post hoc test (p ˂ .05). Result: Fracture load (mean ± SD) of Zr-FPDs, Zr-IRFPDs and ZrC-IRFPDs were 672 ± 183, 672 ± 123 and 638 ± 59, respectively, being not statistically different (p > .05). VS-IRFPD exhibited statically lower values (391 ± 136). The predominant mode of failure was fracture at the connector area in all groups. Conclusion: The fracture load of 3-unit IRFPD was significantly affected by types of ceramics but the retainer design and surface treatment in Zr groups did not show a significant effect.


  • Open Access

    In Vitro Evaluation of the Effect of Different Surface Treatments of a Hybrid Ceramic on the Microtensile Bond Strength to a Luting Resin Cement

    by Fariba Motevasselian, Zahra Amiri, Nasim Chiniforush, Mansoreh Mirzaei, Van Thompson

    Introduction: The aim of the present study was to investigate the effect of different surface treatments of a hybrid ceramic, Vita Enamic, on the micro-tensile bond strength (µ-TBS) to resin cement. Methods: Ten blocks (3×10×8 mm) were retrieved from the original blocks and divided into 5 groups according to the different surface treatments performed: Groups 1: 35% acid phosphoric for 60 seconds (PA); group 2: Sandblasting with 50 µm Al2 O3 particles for 10 seconds (SB); groups 3: 9.5% hydrofluoric acid for 60 seconds (HF), group 4: The Er:YAG laser (2 W, 10 Hz) (ER1), group 5: The Er:YAG laser (3 W, 10 Hz) (ER2). All treated surfaces were salinized and the blocks with similar surface treatments were bonded together using a dual-cured resin cement and light-cured. After 24-hour storage in water, the blocks were cut into beams (1 mm2 ). Half of the specimens in each group (n=16) were tested immediately and the rest were subjected to thermocycling between 5°C and 55°C for 6000 cycles before the µ-TBS test at a crosshead speed of 0.5 mm/min. The data were analyzed using two-way analysis of variance (ANOVA) and Tukey HSD tests and the significance level was set at 0.05. The failure mode was evaluated by using a stereomicroscope. Results: The µ-TBS was clearly influenced by surface treatment methods (P<0.001) and thermocycling significantly decreased the bond strength values in all groups (P=0.007). The highest value (66.07 MPa ± 11.3) was obtained for the HF groups with no thermocycling and the lowest values were observed in the laser groups with no significant difference among different irradiation parameters. Adhesive failure was mainly observed in the PA and SB groups while mixed failure was predominantly shown in the laser and HF groups. Conclusion: This study demonstrated that surface treatment of VE with HF and salinization could improve the bond strength to a dual-cured resin cement, and Er:YAG laser irradiation with the evaluated parameters did not promote the adhesion of the resin cement to VE.


    • 1 November 2017
      • Vol. 14  (6) , 337-343
    Open Access

    Adherence of Streptococcus Mutans to Microhybrid and Nanohybrid Resin Composites and Dental Amalgam: An In Vitro Study

    by Fariba Motevasselian, Ensieh Zibafar, Esmail Yassini, Mansoreh Mirzaei, Naser Pourmirhoseni

    Streptococcus mutans (S. mutans) is a cariogenic microorganism. The restorative materials which harbor a biofilm with high levels of S. mutans can accelerate the occurrence of dental caries. The purpose of this study was to evaluate the influence of different restorative materials on S. mutans colonization in a simple in-vitro biofilm formation model. Thirteen discs of each material (nanohybrid resin composite, microhybrid resin composite, and amalgam) were prepared, polished, and sterilized in a gamma radiation chamber. The saliva-free specimens were exposed to the S. mutans bacterial suspension (0.5 McFarland) and were incubated for 4 hours. Afterwards, the specimens were rinsed and sonicated in normal saline. 10μl of the obtained suspension was cultured in a sterile blood agar medium. After 24 hours, the number of colony forming units (CFU) of S. mutans was counted. A sterility test control was considered for each group of materials. The data were analyzed by one-way ANOVA at 5% significance level. The means and standard deviations of the logarithmic values of the colonies on the surfaces of amalgam, microhybrid, and nanohybrid resin composites were equal to 3.76±0.64, 3.91±0.52 and 3.34±0.74, respectively. There were no significant differences between the restorative materials in terms of S. mutans adhesion rate. The evaluated resin composites showed comparable numbers of CFUs, which could imply the importance of the polishing procedures.


  • Open Access

    Effect of Type of Surface Treatment and Adhesive System on Shear Bond Strength of Composite Resin to a Non-Precious Metal Alloy

    by Esmaeil Yasini, Mansooreh Mirzaie, Hamid Kermanshah, Elahe Habibi, Fariba Motevasselian, Tehran Specialist In Restorative And Esthetic Dentistry

    Sedative Effect of Midazolam Elixir Compare to Vial Through Oral Route in Uncooperative Pediatric Dental Patients M. Fallahinejad Ghajari 1, G. Ansari 1, S. Zomorrodian 2, S. Shayeghi 3. 1 Professor, Dental Research Center, Research Institute of Dental Sciences AND Department of Pediatric Dentistry, School of Den-tistry, Shahid Beheshti University of ...