Melissa H. Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Melissa H. Lee has a total of 142 co-authors. Here are the top co-authors by number of shared publications:
- David Norman O'Neal
Department of Endocrinology and Diabetes, St Vincent’s Hospital Melbourne, Fitzroy, Victoria, Australia
12 shared publications - Richard J. MacIsaac
Department of Endocrinology and Diabetes St Vincent's Hospital Melbourne Melbourne Victoria Australia
9 shared publications - Sybil A. McAuley
Department of Psychology The Cairnmillar Institute Melbourne Victoria Australia
9 shared publications - Alicia Josephine Jenkins
Baker Heart and Diabetes Institute, Melbourne, Australia
8 shared publications Sara Vogrin
Department of Medicine University of Melbourne Melbourne Victoria Australia
8 shared publicationsGlenn M. Ward
Department of Medicine, The University of Melbourne, Melbourne, VIC, Australia
6 shared publications
Latest Publications
- Open Access
- 29 April 2026
- Published by MDPI AG in Endocrines
- Vol. 7 (2) , 18
Immune Checkpoint Inhibitor-Associated Diabetes Mellitus: Future Perspectives and Emerging Therapies
Objective: Current knowledge surrounding the diagnosis and mechanisms that result in immune checkpoint inhibitor-associated diabetes (ICI-DM) remain to be fully defined. We present clinical vignettes of patients that have presented to our hospital to illustrate the heterogenous clinical profiles that patients with ICI-DM can experience. We also provide an update on ICI-DM, focusing on current and future perspectives and emerging therapies. Methods: We performed a retrospective review of the electronic records of five ICI-DM patients who presented to St. Vincent’s Hospital Melbourne between 2020 and 2024, with patients identified from the hospital endocrinology and oncology databases. We also performed a literature review via a PubMed search using the keywords “checkpoint inhibitors” and “diabetes” between the years 2015 and 2025 to allow us to collate a descriptive review on ICI-DM. Results: Our cases show some heterogeneity in presentation, with biochemical evidence of diabetic ketoacidosis (DKA) in 4/5 patients, presentation 18–253 days (median 47 days) from ICI commencement, HbA1c 59–78 mmol/mol (median 66 mmol/mol), and c-peptide 0.06–0.77 pmol/mL (median 0.09 pmol/mL). Islet autoantibodies were present in 4/5 cases and high-risk HLA alleles identified in 1/2 tested patients. The findings from our descriptive review support a similar heterogeneity in ICI-DM presentations. Inconsistent diagnostic criteria for ICI-DM were noted with low c-peptide being the most common biochemical presentation. Pancreatic volume is emerging as a useful predictive marker of ICI-DM development. We found no reports of the reversal of ICI-DM with immunosuppression in humans, although recent preclinical studies suggest that this approach is feasible. Conclusions: Diagnostic criteria should include new-onset hyperglycaemia with low paired c-peptide, and may be supported with T1DM-associated autoantibodies and evidence of pancreatic atrophy on imaging. Further research is needed in the realm of predicting ICI-DM and considering the role of immunosuppression as a treatment modality.
- 29 April 2026
- Published by MDPI AG in Endocrines
- Vol. 7 (2) , 18
Open AccessImmune Checkpoint Inhibitor-Associated Diabetes Mellitus: Future Perspectives and Emerging Therapies
Objective: Current knowledge surrounding the diagnosis and mechanisms that result in immune checkpoint inhibitor-associated diabetes (ICI-DM) remain to be fully defined. We present clinical vignettes of patients that have presented to our hospital to illustrate the heterogenous clinical profiles that patients with ICI-DM can experience. We also provide an update on ICI-DM, focusing on current and future perspectives and emerging therapies. Methods: We performed a retrospective review of the electronic records of five ICI-DM patients who presented to St. Vincent’s Hospital Melbourne between 2020 and 2024, with patients identified from the hospital endocrinology and oncology databases. We also performed a literature review via a PubMed search using the keywords “checkpoint inhibitors” and “diabetes” between the years 2015 and 2025 to allow us to collate a descriptive review on ICI-DM. Results: Our cases show some heterogeneity in presentation, with biochemical evidence of diabetic ketoacidosis (DKA) in 4/5 patients, presentation 18–253 days (median 47 days) from ICI commencement, HbA1c 59–78 mmol/mol (median 66 mmol/mol), and c-peptide 0.06–0.77 pmol/mL (median 0.09 pmol/mL). Islet autoantibodies were present in 4/5 cases and high-risk HLA alleles identified in 1/2 tested patients. The findings from our descriptive review support a similar heterogeneity in ICI-DM presentations. Inconsistent diagnostic criteria for ICI-DM were noted with low c-peptide being the most common biochemical presentation. Pancreatic volume is emerging as a useful predictive marker of ICI-DM development. We found no reports of the reversal of ICI-DM with immunosuppression in humans, although recent preclinical studies suggest that this approach is feasible. Conclusions: Diagnostic criteria should include new-onset hyperglycaemia with low paired c-peptide, and may be supported with T1DM-associated autoantibodies and evidence of pancreatic atrophy on imaging. Further research is needed in the realm of predicting ICI-DM and considering the role of immunosuppression as a treatment modality.
- 2 February 2026
- Published by Elsevier in Diabetes Research and Clinical Practice
- Vol. 233, 113136
Survey of glucose levels in adults with T1DM attending clinic using automated insulin delivery (AID) devices compared with manual insulin delivery
- 2 February 2026
- Published by Elsevier in Diabetes Research and Clinical Practice
- Vol. 233, 113136
Survey of glucose levels in adults with T1DM attending clinic using automated insulin delivery (AID) devices compared with manual insulin delivery
- Open Access
- 22 December 2024
- Published by BMJ in BMJ Open Diabetes Research & Care
- Vol. 12 (6) , e004428
Six months of hybrid closed-loop therapy improves diabetes-specific positive well-being, and reduces diabetes distress and fear of hypoglycemia: secondary analysis of a randomized controlled trial
Introduction: This analysis aimed to investigate diabetes-specific psychological outcomes among adults with type 1 diabetes (T1D) using hybrid closed-loop (HCL) versus standard therapy. Research design and methods: In this multicenter, open-label, randomized, controlled, parallel-group clinical trial, adults with T1D were allocated to 26 weeks of HCL (MiniMed™ 670G) or standard therapy (insulin pump or multiple daily injections without real-time continuous glucose monitoring). Psychological outcomes (awareness and fear of hypoglycemia; and diabetes-specific positive well-being, diabetes distress, diabetes treatment satisfaction, and diabetes-specific quality of life (QoL)) were measured at enrollment, mid-trial and end-trial. Linear mixed models were conducted, using restricted maximum likelihood estimation, unadjusted and adjusted (for covariates: age, sex, diabetes duration, glycated hemoglobin, recent severe hypoglycemia, pre-trial insulin delivery modality, enrollment and mid-study scores). Results: 120 participants (mean age 44±12 years) were randomized to intervention (n=61) or standard therapy (n=59). At 13 weeks, the HCL group had better diabetes-specific positive well-being than the standard therapy group (unadjusted: Δ=1.0, p=0.025; adjusted: Δ=1.1, p=0.01), which was maintained at 26 weeks (unadjusted: Δ=0.9, p=0.042; adjusted: Δ=1.0, p=0.023). At 26 weeks, the HCL group also had less diabetes distress (adjusted: Δ=−6.4, p=0.039), fear of hypoglycemia (“maintain high”: adjusted: Δ=−0.8, p=0.034; and “worry”: adjusted: Δ=−1.8, p=0.048), and perceived “unacceptably high glucose levels” (unadjusted: Δ=−1.1, p<0.001; adjusted: Δ=−1.1, p<0.001). HCL did not improve diabetes treatment satisfaction, diabetes-specific QoL, hypoglycemia awareness, or perceived frequency of unacceptably low glucose levels. Conclusions: These findings imply that HCL offers important psychological benefits. In particular, improvement in diabetes-specific positive well-being was observed 13 weeks after HCL initiation and maintained at 26 weeks. Reduction in the perceived frequency of hyperglycemia was also apparent by 26 weeks. Adjusted analyses showed significant reductions in diabetes distress and fear of hypoglycemia at 26 weeks, suggesting these benefits were apparent for people with particular characteristics. Trial registration number: Australian New Zealand Clinical Trials Registry: ACTRN12617000520336.
- 22 December 2024
- Published by BMJ in BMJ Open Diabetes Research & Care
- Vol. 12 (6) , e004428
Open AccessSix months of hybrid closed-loop therapy improves diabetes-specific positive well-being, and reduces diabetes distress and fear of hypoglycemia: secondary analysis of a randomized controlled trial
Introduction: This analysis aimed to investigate diabetes-specific psychological outcomes among adults with type 1 diabetes (T1D) using hybrid closed-loop (HCL) versus standard therapy. Research design and methods: In this multicenter, open-label, randomized, controlled, parallel-group clinical trial, adults with T1D were allocated to 26 weeks of HCL (MiniMed™ 670G) or standard therapy (insulin pump or multiple daily injections without real-time continuous glucose monitoring). Psychological outcomes (awareness and fear of hypoglycemia; and diabetes-specific positive well-being, diabetes distress, diabetes treatment satisfaction, and diabetes-specific quality of life (QoL)) were measured at enrollment, mid-trial and end-trial. Linear mixed models were conducted, using restricted maximum likelihood estimation, unadjusted and adjusted (for covariates: age, sex, diabetes duration, glycated hemoglobin, recent severe hypoglycemia, pre-trial insulin delivery modality, enrollment and mid-study scores). Results: 120 participants (mean age 44±12 years) were randomized to intervention (n=61) or standard therapy (n=59). At 13 weeks, the HCL group had better diabetes-specific positive well-being than the standard therapy group (unadjusted: Δ=1.0, p=0.025; adjusted: Δ=1.1, p=0.01), which was maintained at 26 weeks (unadjusted: Δ=0.9, p=0.042; adjusted: Δ=1.0, p=0.023). At 26 weeks, the HCL group also had less diabetes distress (adjusted: Δ=−6.4, p=0.039), fear of hypoglycemia (“maintain high”: adjusted: Δ=−0.8, p=0.034; and “worry”: adjusted: Δ=−1.8, p=0.048), and perceived “unacceptably high glucose levels” (unadjusted: Δ=−1.1, p<0.001; adjusted: Δ=−1.1, p<0.001). HCL did not improve diabetes treatment satisfaction, diabetes-specific QoL, hypoglycemia awareness, or perceived frequency of unacceptably low glucose levels. Conclusions: These findings imply that HCL offers important psychological benefits. In particular, improvement in diabetes-specific positive well-being was observed 13 weeks after HCL initiation and maintained at 26 weeks. Reduction in the perceived frequency of hyperglycemia was also apparent by 26 weeks. Adjusted analyses showed significant reductions in diabetes distress and fear of hypoglycemia at 26 weeks, suggesting these benefits were apparent for people with particular characteristics. Trial registration number: Australian New Zealand Clinical Trials Registry: ACTRN12617000520336.
- 27 November 2024
- Published by Wiley in Internal Medicine Journal
- Vol. 55 (1) , 148-153
Results of an Australian trial of an automated insulin delivery (AID) system and other studies support likely benefit of AID use for many Australian adults with type 1 diabetes
Less than 20% of Australians with type 1 diabetes (T1D) meet recommended glucose targets. Technology use is associated with better glycaemia, with the most advanced being automated insulin delivery (AID) systems, which are now recommended as gold‐standard T1D care. Our Australian AID trial shows a wide spectrum of adults with T1D can achieve recommended targets. Other studies, including lived experience data, are supportive. Insulin pumps are not subsidised for most Australian adults with T1D. We advocate change.
- 27 November 2024
- Published by Wiley in Internal Medicine Journal
- Vol. 55 (1) , 148-153
Results of an Australian trial of an automated insulin delivery (AID) system and other studies support likely benefit of AID use for many Australian adults with type 1 diabetes
Less than 20% of Australians with type 1 diabetes (T1D) meet recommended glucose targets. Technology use is associated with better glycaemia, with the most advanced being automated insulin delivery (AID) systems, which are now recommended as gold‐standard T1D care. Our Australian AID trial shows a wide spectrum of adults with T1D can achieve recommended targets. Other studies, including lived experience data, are supportive. Insulin pumps are not subsidised for most Australian adults with T1D. We advocate change.
- 29 July 2024
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 20 (1) , 87-94
Accuracy and Feasibility of a Novel Glucose/Lactate Continuous Multi-Analyte Sensing Platform in Humans
Background and aim: Continuous glucose monitoring systems (CGMs) have been commercially available since 1999. However, automated insulin delivery systems may benefit from real-time inputs in addition to glucose. Continuous multi-analyte sensing platforms will meet this area of potential growth without increasing the burden of additional devices. We aimed to generate pilot data regarding the safety and function of a first-in-human, single-probe glucose/lactate multi-analyte continuous sensor. Methods: The investigational glucose/lactate continuous multi-analyte sensor (PercuSense Inc, Valencia, California) was inserted to the upper arms of 16 adults with diabetes, and data were available for analysis from 11 of these participants (seven female; mean [SD] = age 43 years [16]; body mass index [BMI] = 27 kg/m 2 [5]). A commercially available Guardian 3 CGM (Medtronic, Northridge, California) was also inserted into the abdomen for comparison. All participants underwent a meal-test followed by an exercise challenge on day 1 and day 4 of wear. Performance was benchmarked against venous blood YSI glucose and lactate values. Results: The investigational glucose sensor had an overall mean absolute relative difference (MARD) of 14.5% (median = 11.2%) which improved on day 4 compared with day 1 (13.9% vs 15.2%). The Guardian 3 CGM had an overall MARD of 13.9% (median = 9.4%). The lactate sensor readings within 20/20% and 40/40% of YSI values were 59.7% and 83.1%, respectively. Conclusions: Our initial data support safety and functionality of a novel glucose/lactate continuous multi-analyte sensor. Further sensor refinement will improve run-in performance and accuracy.
- 29 July 2024
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 20 (1) , 87-94
Accuracy and Feasibility of a Novel Glucose/Lactate Continuous Multi-Analyte Sensing Platform in Humans
Background and aim: Continuous glucose monitoring systems (CGMs) have been commercially available since 1999. However, automated insulin delivery systems may benefit from real-time inputs in addition to glucose. Continuous multi-analyte sensing platforms will meet this area of potential growth without increasing the burden of additional devices. We aimed to generate pilot data regarding the safety and function of a first-in-human, single-probe glucose/lactate multi-analyte continuous sensor. Methods: The investigational glucose/lactate continuous multi-analyte sensor (PercuSense Inc, Valencia, California) was inserted to the upper arms of 16 adults with diabetes, and data were available for analysis from 11 of these participants (seven female; mean [SD] = age 43 years [16]; body mass index [BMI] = 27 kg/m 2 [5]). A commercially available Guardian 3 CGM (Medtronic, Northridge, California) was also inserted into the abdomen for comparison. All participants underwent a meal-test followed by an exercise challenge on day 1 and day 4 of wear. Performance was benchmarked against venous blood YSI glucose and lactate values. Results: The investigational glucose sensor had an overall mean absolute relative difference (MARD) of 14.5% (median = 11.2%) which improved on day 4 compared with day 1 (13.9% vs 15.2%). The Guardian 3 CGM had an overall MARD of 13.9% (median = 9.4%). The lactate sensor readings within 20/20% and 40/40% of YSI values were 59.7% and 83.1%, respectively. Conclusions: Our initial data support safety and functionality of a novel glucose/lactate continuous multi-analyte sensor. Further sensor refinement will improve run-in performance and accuracy.
- 30 April 2024
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 26 (5) , 335-340
Driving-Related Glucose Patterns Among Older Adults with Type 1 Diabetes
Older adults with type 1 diabetes may face challenges driving safely. Glucose “above-5-to-drive” is often recommended for insulin-treated diabetes to minimize hypoglycemia while driving. However, the effectiveness of this recommendation among older adults has not been evaluated. Older drivers with type 1 diabetes were assessed while using sensor-augmented insulin pumps during a 2-week clinical trial run-in. Twenty-three drivers (median age 69 years [interquartile range; IQR 65–72]; diabetes duration 37 years [20–45]) undertook 618 trips (duration 10 min [5–21]). Most trips ( n = 535; 87%) were 5.0 mmol/L for 577 trips (93%) and none of these had CGM 90 min and 3 trips >120 min). During 41 trips with pre-trip CGM ≤5.0 mmol/L, 11 trips had CGM <3.9 mmol/L. Seventy-one CGM alerts occurred during 60 trips (10%), of which 54 of 71 alerts (76%) were unrelated to hypoglycemia. Our findings support a glucose “above-5-to-drive” recommendation to avoid CGM-detected hypoglycemia among older drivers, including for prolonged drives, and highlight the importance of active CGM low-glucose alerts to prevent hypoglycemia during driving. Driving-related CGM usability and alert functionality warrant investigation. Clinical trial ACTRN1261900515190
- 30 April 2024
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 26 (5) , 335-340
Driving-Related Glucose Patterns Among Older Adults with Type 1 Diabetes
Older adults with type 1 diabetes may face challenges driving safely. Glucose “above-5-to-drive” is often recommended for insulin-treated diabetes to minimize hypoglycemia while driving. However, the effectiveness of this recommendation among older adults has not been evaluated. Older drivers with type 1 diabetes were assessed while using sensor-augmented insulin pumps during a 2-week clinical trial run-in. Twenty-three drivers (median age 69 years [interquartile range; IQR 65–72]; diabetes duration 37 years [20–45]) undertook 618 trips (duration 10 min [5–21]). Most trips ( n = 535; 87%) were 5.0 mmol/L for 577 trips (93%) and none of these had CGM 90 min and 3 trips >120 min). During 41 trips with pre-trip CGM ≤5.0 mmol/L, 11 trips had CGM <3.9 mmol/L. Seventy-one CGM alerts occurred during 60 trips (10%), of which 54 of 71 alerts (76%) were unrelated to hypoglycemia. Our findings support a glucose “above-5-to-drive” recommendation to avoid CGM-detected hypoglycemia among older drivers, including for prolonged drives, and highlight the importance of active CGM low-glucose alerts to prevent hypoglycemia during driving. Driving-related CGM usability and alert functionality warrant investigation. Clinical trial ACTRN1261900515190
- 13 April 2024
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 19 (6) , 1578-1590
Hybrid Closed Loop in Adults With Type 1 Diabetes and Severely Impaired Hypoglycemia Awareness
Background: Benefits of hybrid closed-loop (HCL) systems in a high-risk group with type 1 diabetes and impaired awareness of hypoglycemia (IAH) have not been well-explored. Methods: Adults with Edmonton HYPO scores ≥1047 were randomized to 26-weeks HCL (MiniMed™ 670G) vs standard therapy (multiple daily injections or insulin pump) without continuous glucose monitoring (CGM) (control). Primary outcome was percentage CGM time-in-range (TIR; 70-180 mg/dL) at 23 to 26 weeks post-randomization. Major secondary endpoints included magnitude of change in counter-regulatory hormones and autonomic symptom responses to hypoglycemia at 26-weeks post-randomization. A post hoc analysis evaluated glycemia risk index (GRI) comparing HCL with control groups at 26 weeks post-randomization. Results: Nine participants (median [interquartile range (IQR)] age 51 [41, 59] years; 44% male; enrolment HYPO score 1183 [1058, 1308]; Clarke score 6 [6, 6]; n = 5 [HCL]; n = 4 [control]) completed the study. Time-in-range was higher using HCL vs control (70% [68, 74%] vs 48% [44, 50%], P = .014). Time P = .14) although hypoglycemia episode duration was shorter (30 vs 50 minutes, P < .001) with HCL. Glycemia risk index was lower with HCL vs control (38.1 [30.0, 39.2] vs 70.8 [58.5, 72.4], P = .014). Following 6 months of HCL use, greater dopamine (24.0 [12.3, 27.6] vs −18.5 [−36.5, −4.8], P = .014), and growth hormone (6.3 [4.6, 16.8] vs 0.5 [−0.8, 3.0], P = .050) responses to hypoglycemia were observed. Conclusions: Six months of HCL use in high-risk adults with severe IAH increased glucose TIR and improved GRI without increased hypoglycemia, and partially restored counter-regulatory responses. Clinical trial registration: ACTRN12617000520336
- 13 April 2024
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 19 (6) , 1578-1590
Hybrid Closed Loop in Adults With Type 1 Diabetes and Severely Impaired Hypoglycemia Awareness
Background: Benefits of hybrid closed-loop (HCL) systems in a high-risk group with type 1 diabetes and impaired awareness of hypoglycemia (IAH) have not been well-explored. Methods: Adults with Edmonton HYPO scores ≥1047 were randomized to 26-weeks HCL (MiniMed™ 670G) vs standard therapy (multiple daily injections or insulin pump) without continuous glucose monitoring (CGM) (control). Primary outcome was percentage CGM time-in-range (TIR; 70-180 mg/dL) at 23 to 26 weeks post-randomization. Major secondary endpoints included magnitude of change in counter-regulatory hormones and autonomic symptom responses to hypoglycemia at 26-weeks post-randomization. A post hoc analysis evaluated glycemia risk index (GRI) comparing HCL with control groups at 26 weeks post-randomization. Results: Nine participants (median [interquartile range (IQR)] age 51 [41, 59] years; 44% male; enrolment HYPO score 1183 [1058, 1308]; Clarke score 6 [6, 6]; n = 5 [HCL]; n = 4 [control]) completed the study. Time-in-range was higher using HCL vs control (70% [68, 74%] vs 48% [44, 50%], P = .014). Time P = .14) although hypoglycemia episode duration was shorter (30 vs 50 minutes, P < .001) with HCL. Glycemia risk index was lower with HCL vs control (38.1 [30.0, 39.2] vs 70.8 [58.5, 72.4], P = .014). Following 6 months of HCL use, greater dopamine (24.0 [12.3, 27.6] vs −18.5 [−36.5, −4.8], P = .014), and growth hormone (6.3 [4.6, 16.8] vs 0.5 [−0.8, 3.0], P = .050) responses to hypoglycemia were observed. Conclusions: Six months of HCL use in high-risk adults with severe IAH increased glucose TIR and improved GRI without increased hypoglycemia, and partially restored counter-regulatory responses. Clinical trial registration: ACTRN12617000520336
- 21 February 2024
- Published by American Diabetes Association in Diabetes Care
- Vol. 47 (4) , 747-755
Improved Satisfaction While Maintaining Safety and High Time in Range (TIR) With a Medtronic Investigational Enhanced Advanced Hybrid Closed-Loop (e-AHCL) System
OBJECTIVE: To determine feasibility and compare acceptance of an investigational Medtronic enhanced advanced hybrid closed-loop (e-AHCL) system in adults with type 1 diabetes with earlier iterations. RESEARCH DESIGN AND METHODS: This nonrandomized three-stage (12 weeks each) exploratory study compared e-AHCL (Bluetooth-enabled MiniMed 780G insulin pump with automatic data upload [780G] incorporating an updated algorithm; calibration-free all-in-one disposable sensor; 7-day infusion set) preceded by a run-in (non-Bluetooth 780G [670G V4.0 insulin pump] requiring manual data upload; Guardian Sensor 3 [GS3] requiring calibration; 3-day infusion set), stage 1 (780G; GS3; 3-day infusion set), and stage 2 (780G; calibration-free Guardian Sensor 4; 3-day infusion set). Treatment satisfaction was assessed by Diabetes Technology Questionnaire (DTQ)-current (primary outcome) and other validated treatment satisfaction tools with glucose outcomes by continuous glucose monitoring metrics. RESULTS: Twenty-one of 22 (11 women) participants (baseline HbA1c 6.7%/50 mmol/mol) completed the study. DTQ-current scores favored e-AHCL (123.1 [17.8]) versus run-in (101.6 [24.2]) and versus stage 1 (110.6 [20.8]) (both P < 0.001) but did not differ from stage 2 (119.4 [16.0]; P = 0.271). Diabetes Medication System Rating Questionnaire short-form scores for “Convenience and Efficacy” favored e-AHCL over run-in and all stages. Percent time in range 70–180 mg/dL was greater with e-AHCL versus run-in and stage 2 (+2.9% and +3.6%, respectively; both P < 0.001). Percent times of <70 mg/dL for e-AHCL were significantly lower than run-in, stage 1, and stage 2 (−0.9%, −0.6%, and −0.5%, respectively; all P < 0.01). CONCLUSIONS: e-AHCL was feasible. User satisfaction increased compared with earlier Medtronic HCL iterations without compromising glucose control.
- 21 February 2024
- Published by American Diabetes Association in Diabetes Care
- Vol. 47 (4) , 747-755
Improved Satisfaction While Maintaining Safety and High Time in Range (TIR) With a Medtronic Investigational Enhanced Advanced Hybrid Closed-Loop (e-AHCL) System
OBJECTIVE: To determine feasibility and compare acceptance of an investigational Medtronic enhanced advanced hybrid closed-loop (e-AHCL) system in adults with type 1 diabetes with earlier iterations. RESEARCH DESIGN AND METHODS: This nonrandomized three-stage (12 weeks each) exploratory study compared e-AHCL (Bluetooth-enabled MiniMed 780G insulin pump with automatic data upload [780G] incorporating an updated algorithm; calibration-free all-in-one disposable sensor; 7-day infusion set) preceded by a run-in (non-Bluetooth 780G [670G V4.0 insulin pump] requiring manual data upload; Guardian Sensor 3 [GS3] requiring calibration; 3-day infusion set), stage 1 (780G; GS3; 3-day infusion set), and stage 2 (780G; calibration-free Guardian Sensor 4; 3-day infusion set). Treatment satisfaction was assessed by Diabetes Technology Questionnaire (DTQ)-current (primary outcome) and other validated treatment satisfaction tools with glucose outcomes by continuous glucose monitoring metrics. RESULTS: Twenty-one of 22 (11 women) participants (baseline HbA1c 6.7%/50 mmol/mol) completed the study. DTQ-current scores favored e-AHCL (123.1 [17.8]) versus run-in (101.6 [24.2]) and versus stage 1 (110.6 [20.8]) (both P < 0.001) but did not differ from stage 2 (119.4 [16.0]; P = 0.271). Diabetes Medication System Rating Questionnaire short-form scores for “Convenience and Efficacy” favored e-AHCL over run-in and all stages. Percent time in range 70–180 mg/dL was greater with e-AHCL versus run-in and stage 2 (+2.9% and +3.6%, respectively; both P < 0.001). Percent times of <70 mg/dL for e-AHCL were significantly lower than run-in, stage 1, and stage 2 (−0.9%, −0.6%, and −0.5%, respectively; all P < 0.01). CONCLUSIONS: e-AHCL was feasible. User satisfaction increased compared with earlier Medtronic HCL iterations without compromising glucose control.
- 19 February 2024
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 18 (4) , 764-770
Hybrid Closed-Loop Versus Manual Insulin Delivery in Adults With Type 1 Diabetes: A Post Hoc Analysis Using the Glycemia Risk Index
Background: Glycemia risk index (GRI) is a novel composite metric assessing overall glycemic risk, accounting for both hypoglycemia and hyperglycemia and weighted toward extremes. Data assessing GRI as an outcome measure in closed-loop studies and its relation with conventional key continuous glucose monitoring (CGM) metrics are limited. Methods: A post hoc analysis was performed to evaluate the sensitivity of GRI in assessing glycemic quality in adults with type 1 diabetes randomized to 26 weeks hybrid closed-loop (HCL) or manual insulin delivery (control). The primary outcome was GRI comparing HCL with control. Comparisons were made with changes in other CGM metrics including time in range (TIR), time above range (TAR), time below range (TBR), and glycemic variability (standard deviation [SD] and coefficient of variation [CV]). Results: GRI with HCL (N = 61) compared with control (N = 59) was significantly lower (mean [SD] 33.5 [11.7] vs 56.1 [14.4], respectively; mean difference −22.8 [−27.2, −18.3], P = .001). The mean increase in TIR was +14.8 (11.0, 18.5)%. GRI negatively correlated with TIR for combined arms ( r = −.954; P = .001), and positively with TAR >250 mg/dL ( r = .901; P = .001), TBR < 54 mg/dL ( r = .416; P = .001), and glycemic variability (SD [ r = .916] and CV [ r = .732]; P = .001 for both). Conclusions: Twenty-six weeks of HCL improved GRI, in addition to other CGM metrics, compared with standard insulin therapy. The improvement in GRI was proportionally greater than the change in TIR, and GRI correlated with all CGM metrics. We suggest that GRI may be an appropriate primary outcome for closed-loop trials.
- 19 February 2024
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 18 (4) , 764-770
Hybrid Closed-Loop Versus Manual Insulin Delivery in Adults With Type 1 Diabetes: A Post Hoc Analysis Using the Glycemia Risk Index
Background: Glycemia risk index (GRI) is a novel composite metric assessing overall glycemic risk, accounting for both hypoglycemia and hyperglycemia and weighted toward extremes. Data assessing GRI as an outcome measure in closed-loop studies and its relation with conventional key continuous glucose monitoring (CGM) metrics are limited. Methods: A post hoc analysis was performed to evaluate the sensitivity of GRI in assessing glycemic quality in adults with type 1 diabetes randomized to 26 weeks hybrid closed-loop (HCL) or manual insulin delivery (control). The primary outcome was GRI comparing HCL with control. Comparisons were made with changes in other CGM metrics including time in range (TIR), time above range (TAR), time below range (TBR), and glycemic variability (standard deviation [SD] and coefficient of variation [CV]). Results: GRI with HCL (N = 61) compared with control (N = 59) was significantly lower (mean [SD] 33.5 [11.7] vs 56.1 [14.4], respectively; mean difference −22.8 [−27.2, −18.3], P = .001). The mean increase in TIR was +14.8 (11.0, 18.5)%. GRI negatively correlated with TIR for combined arms ( r = −.954; P = .001), and positively with TAR >250 mg/dL ( r = .901; P = .001), TBR < 54 mg/dL ( r = .416; P = .001), and glycemic variability (SD [ r = .916] and CV [ r = .732]; P = .001 for both). Conclusions: Twenty-six weeks of HCL improved GRI, in addition to other CGM metrics, compared with standard insulin therapy. The improvement in GRI was proportionally greater than the change in TIR, and GRI correlated with all CGM metrics. We suggest that GRI may be an appropriate primary outcome for closed-loop trials.
- 16 August 2022
- Published by Wiley in Internal Medicine Journal
- Vol. 52 (8) , 1434-1436
Insulin antibodies are prevalent in adults with type 1 diabetes referred for islet cell transplantation and are modified by islet transplantation and immunosuppression: an Australian experience
We have analysed insulin antibodies in 149 adults with type 1 diabetes and 2859 people without diabetes. We have determined that insulin antibody levels are higher in adults with, versus without, diabetes and that the levels are falling, and more patients are becoming antibody‐negative post islet cell transplantation.
- 16 August 2022
- Published by Wiley in Internal Medicine Journal
- Vol. 52 (8) , 1434-1436
Insulin antibodies are prevalent in adults with type 1 diabetes referred for islet cell transplantation and are modified by islet transplantation and immunosuppression: an Australian experience
We have analysed insulin antibodies in 149 adults with type 1 diabetes and 2859 people without diabetes. We have determined that insulin antibody levels are higher in adults with, versus without, diabetes and that the levels are falling, and more patients are becoming antibody‐negative post islet cell transplantation.