MMMichael McMullen

Michael McMullen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael McMullen has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dobutamine and Goal-Directed Fluid Therapy for Improving Tissue Oxygenation in Deep Inferior Epigastric Perforator (DIEP) Flap Breast Reconstruction Surgery: Protocol for a Randomized Controlled Trial

    by Glenio B Mizubuti, Anthony M-H Ho, Rachel Phelan, Deborah DuMerton, Jessica Shelley, Elorm Vowotor, Jessica Xiong, Bethany Smethurst, Michael McMullen, Wilma M Hopman, et al.

    Background: Breast reconstruction is an integral part of breast cancer care. There are 2 main types of breast reconstruction: alloplastic (using implants) and autologous (using the patient’s own tissue). The latter creates a more natural breast mound and avoids the long-term need for surgical revision—more often associated with implant-based surgery. The deep inferior epigastric perforator (DIEP) flap is considered the gold standard approach in autologous breast reconstruction. However, complications do occur with DIEP flap surgery and can stem from poor flap tissue perfusion/oxygenation. Hence, the development of strategies to enhance flap perfusion (eg, goal-directed perioperative fluid therapy) is essential. Current perioperative fluid therapy is traditionally guided by subjective criteria, which leads to wide variations in clinical practice. Objective: The main objective of this trial is to determine whether the use of minimally invasive cardiac output (CO) monitoring for guiding intravenous fluid administration, combined with low-dose dobutamine infusion (via a treatment algorithm), will increase tissue oxygenation in patients undergoing DIEP flap surgery. Methods: With appropriate institutional ethics board and Health Canada approval, patients undergoing DIEP flap surgery are randomly assigned to receive CO monitoring for the guidance of intraoperative fluid therapy in addition to a low-dose dobutamine infusion (which potentially improves flap oxygenation) versus the current standard of care. The primary outcome is tissue oxygenation measured via near-infrared spectroscopy at the perfusion zone furthest from the perforator vessels 45 minutes after vascular reanastomosis of the DIEP flap. Low dose (2.5 μg/kg/hr) dobutamine infusion continues for up to 4 hours postoperatively, provided there are no associated complications (ie, persistent tachycardia). Flap oxygenation, hemodynamic parameters, and any medication-associated side effects/complications are monitored for up to 48 hours postoperatively. Complications, rehospitalizations, and patient satisfaction are also collected until 30 days postoperatively. Results: Funding and regulatory approvals were obtained in 2019, but the study recruitment was interrupted by the COVID-19 pandemic. As of October 4, 2023, 34 participants have been recruited. Because of the significant delays associated with the pandemic, the expected completion date was extended. We expect the study to be completed and ready for potential news release (as appropriate) and publication by July 2024. No patients have suffered any adverse effects/complications from participating in this study, and none have been lost to follow-up. Conclusions: CO-directed fluid therapy in combination with a low-dose dobutamine infusion via a treatment algorithm has the potential to improve DIEP flap tissue oxygenation and reduce complications following DIEP flap breast reconstruction surgery. However, given that the investigators remain blinded to group randomization, no comment can be made regarding the efficacy of this intervention for improving tissue oxygenation at this time. Nevertheless, no patients have been withdrawn for safety concerns thus far, and compliance remains high. Trial Registration: Clinicaltrials.gov NCT04020172; https://clinicaltrials.gov/study/NCT04020172

  • Open Access

    Dobutamine and Goal-Directed Fluid Therapy for Improving Tissue Oxygenation in Deep Inferior Epigastric Perforator (DIEP) Flap Breast Reconstruction Surgery: Protocol for a Randomized Controlled Trial (Preprint)

    by Glenio B Mizubuti, Anthony M-H Ho, Rachel Phelan, Deborah DuMerton, Jessica Shelley, Elorm Vowotor, Jessica Xiong, Bethany Smethurst, Michael McMullen, Wilma M Hopman, et al.

    BACKGROUND Breast reconstruction is an integral part of breast cancer care. There are 2 main types of breast reconstruction: alloplastic (using implants) and autologous (using the patient’s own tissue). The latter creates a more natural breast mound and avoids the long-term need for surgical revision—more often associated with implant-based surgery. The deep inferior epigastric perforator (DIEP) flap is considered the gold standard approach in autologous breast reconstruction. However, complications do occur with DIEP flap surgery and can stem from poor flap tissue perfusion/oxygenation. Hence, the development of strategies to enhance flap perfusion (eg, goal-directed perioperative fluid therapy) is essential. Current perioperative fluid therapy is traditionally guided by subjective criteria, which leads to wide variations in clinical practice. OBJECTIVE The main objective of this trial is to determine whether the use of minimally invasive cardiac output (CO) monitoring for guiding intravenous fluid administration, combined with low-dose dobutamine infusion (via a treatment algorithm), will increase tissue oxygenation in patients undergoing DIEP flap surgery. METHODS With appropriate institutional ethics board and Health Canada approval, patients undergoing DIEP flap surgery are randomly assigned to receive CO monitoring for the guidance of intraoperative fluid therapy in addition to a low-dose dobutamine infusion (which potentially improves flap oxygenation) versus the current standard of care. The primary outcome is tissue oxygenation measured via near-infrared spectroscopy at the perfusion zone furthest from the perforator vessels 45 minutes after vascular reanastomosis of the DIEP flap. Low dose (2.5 μg/kg/hr) dobutamine infusion continues for up to 4 hours postoperatively, provided there are no associated complications (ie, persistent tachycardia). Flap oxygenation, hemodynamic parameters, and any medication-associated side effects/complications are monitored for up to 48 hours postoperatively. Complications, rehospitalizations, and patient satisfaction are also collected until 30 days postoperatively. RESULTS Funding and regulatory approvals were obtained in 2019, but the study recruitment was interrupted by the COVID-19 pandemic. As of October 4, 2023, 34 participants have been recruited. Because of the significant delays associated with the pandemic, the expected completion date was extended. We expect the study to be completed and ready for potential news release (as appropriate) and publication by July 2024. No patients have suffered any adverse effects/complications from participating in this study, and none have been lost to follow-up. CONCLUSIONS CO-directed fluid therapy in combination with a low-dose dobutamine infusion via a treatment algorithm has the potential to improve DIEP flap tissue oxygenation and reduce complications following DIEP flap breast reconstruction surgery. However, given that the investigators remain blinded to group randomization, no comment can be made regarding the efficacy of this intervention for improving tissue oxygenation at this time. Nevertheless, no patients have been withdrawn for safety concerns thus far, and compliance remains high. CLINICALTRIAL Clinicaltrials.gov NCT04020172; https://clinicaltrials.gov/study/NCT04020172

  • A simple technique to assess postoperative epidural functionality

    by Gregory Klar, Anthony M.-H. Ho, Michael McMullen, Devin Stirling, Glenio B. Mizubuti

    To describe an alternative method of measuring the Epidural Waveform Analysis (EWA), a technique through which anesthesiologists can confirm the position of a needle and/or catheter tip in the epidural space. EWA consists of epidural catheter transduction with a pressure system typically used for invasive arterial blood pressure monitoring which generates a characteristic oscillatory waveform (provided the catheter tip is within the epidural space) in synchrony with the pulsatile epidural circulation. The technique requires a double-male connector, a 3-way stopcock and an arterial pressure extension tubing along with the patient’s existing arterial line setup while ensuring a meticulously sterile technique to mitigate the risks of neuraxial infection. The technique described herein has been successfully and routinely applied within our institution to measure EWA with the advantage of being potentially less wasteful. EWA allows anesthesiologists to confirm the correct position of an epidural needle/catheter. We describe a method of successfully measuring EWA while reducing wastefulness.


  • Sensitivity and specificity of waveform analysis for assessing postoperative epidural function

    by Carl Chauvin, Gregory Klar, Wilma M. Hopman, Leopoldo Muniz da Silva, Andrew G. Day, Rachel Phelan, Michael McMullen, Kai Chen, Rodrigo Moreira e Lima, Glenio B. Mizubuti


  • Open Access

    Examining the accuracy of residents’ self-assessments and faculty assessment behaviours in anesthesiology

    by Melinda Fleming, Danika Vautour, Michael McMullen, Nicholas Cofie, Nancy Dalgarno, Rachel Phelan, Glenio Mizubuti

    Background: Residents’ accurate self-assessment and clinical judgment are essential for optimizing their clinical skills development. Evidence from the medical literature suggests that residents generally do poorly at self-assessing their performance, often due to factors relating to learners’ personal backgrounds, cultures, the specific contexts of the learning environment and rater bias or inaccuracies. We evaluated the accuracy of anesthesiology residents’ self-assessed Global Entrustment scores and determined whether differences between faculty and resident scores varied by resident seniority, faculty leniency, and/or year of assessment. Methods: We employed variance components modeling techniques and analyzed 329 pairs of faculty and self-assessed entrustment scores among 43 faculty assessors and 15 residents. Using faculty scores as the gold standard, we compared faculty scores with residents’ scores (xi(faculty)–xi(resident)), and determined residents’ accuracy, including over- and under-confidence. Results: The results indicate that residents were respectively over- and under-confident in 10.9% and 54.4% of the assessments but more consistent in their individual self-assessments (rho = 0.70) than faculty assessors. Faculty scores were significantly higher (α = 0.396; z = 4.39; p < 0.001) than residents’ self-assessed scores. Being a lenient/dovish (β = 0.121, z = 3.16, p < 0.01) and a neutral (β = 0.137, z = 3.57, p < 0.001) faculty assessor predicted a higher likelihood of resident under-confidence. Senior residents were significantly less likely to be under-confident compared to junior residents (β = -0.182, z =-2.45, p < 0.05). The accuracy of self-assessments did not significantly vary during the two years of the study period. Conclusions: The majority of residents’ self-assessments were inaccurate. Our findings may help identify the sources of such inaccuracies.


  • Simulation-based evaluation of anaesthesia residents: optimising resource use in a competency-based assessment framework

    by Melinda Fleming, Michael McMullen, Theresa Beesley, Rylan Egan, Sean Field

    Introduction Simulation training in anaesthesiology bridges the gap between theory and practice by allowing trainees to engage in high-stakes clinical training without jeopardising patient safety. However, implementing simulation-based assessments within an academic programme is highly resource intensive, and the optimal number of scenarios and faculty required for accurate competency-based assessment remains to be determined. Using a generalisability study methodology, we examine the structure of simulation-based assessment in regard to the minimal number of scenarios and faculty assessors required for optimal competency-based assessments. Methods Seventeen anaesthesiology residents each performed four simulations which were assessed by two expert raters. Generalisability analysis (G-analysis) was used to estimate the extent of variance attributable to (1) the scenarios, (2) the assessors and (3) the participants. The D-coefficient and the G-coefficient were used to determine accuracy targets and to predict the impact of adjusting the number of scenarios or faculty assessors. Results We showed that multivariate G-analysis can be used to estimate the number of simulations and raters required to optimise assessment. In this study, the optimal balance was obtained when four scenarios were assessed by two simulation experts. Conclusion Simulation-based assessment is becoming an increasingly important tool for assessing the competency of medical residents in conjunction with other assessment methods. G-analysis can be used to assist in planning for optimal resource use and cost-efficacy.