VIVasfiye Isik

Vasfiye Isik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vasfiye Isik has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Does operator experience affect root canal shaping quality with single-file NiTi Systems?

    by Vasfiye Isik, Mehmet Baybora Kayahan, Ibrahim H AbuTahun, Sang Won Kwak, Hyeon-Cheol Kim

  • Open Access

    Effect of Surface Treatments and Bonding Agents on Microshear Bond Strength of Zirconia-Reinforced Lithium Silicate and Conventional Glass-Ceramics: Silane Versus Universal Adhesive

    by Soner Sismanoglu, Gorkem Sengez, Aliye Tugce Gurcan, Vasfiye Isik, Zeynep Hale Keles

    This in vitro study evaluated the effects of four surface treatments (no treatment, hydrofluoric acid [HF] etching, aluminum oxide [AlO] air abrasion, and tribochemical silica coating [TSC]) and two bonding agents (dedicated silane vs. silane-containing universal adhesive) on the microshear bond strength of four CAD/CAM glass-ceramic materials, including two zirconia-reinforced lithium silicate ceramics and two conventional glass-ceramics. Four CAD/CAM materials (Celtra Duo, IPS e.max CAD, IPS Empress CAD, and Vita Suprinity) were subjected to four surface treatments (no treatment, HF, AlO air abrasion, and TSC) and further divided according to bonding agent application: dedicated silane (Clearfil Ceramic Primer Plus) or silane-containing universal adhesive (Single Bond Universal). Microshear bond strength testing was performed after 24 h of water storage (n = 10). Failure modes were classified under stereomicroscopy, and surface topography was evaluated by SEM. Data were analyzed using three-way ANOVA and Tukey’s HSD test (α = 0.05). All three main factors and their interactions significantly affected bond strength values (p < 0.05; R2 = 0.863). HF etching with silane produced the highest values for most materials. However, IPS Empress CAD treated with TSC and silane yielded the highest overall bond strength (25.2 MPa). Dedicated silane consistently outperformed the universal adhesive across all combinations. ZLS ceramics showed intermediate values with distinct etching patterns compared with conventional glass-ceramics. Optimal bonding protocols for CAD/CAM glass-ceramics are material-dependent. Dedicated silane application is recommended over silane-containing universal adhesives for maximum bond strength.

  • Open Access

    Reliability of Length Marks on Gutta-Percha Cones and Paper Points: In Vitro Study

    by Vasfiye Işık, Mehmet Baybora Kayahan

    Background: To evaluate the standardization of length markings on gutta-percha cones and paper points of different brands.Methods: Twenty gutta-percha cones and 20 paper points with size of 35.02# from 3 commercial brands [Diadent (Vancouver, BC, Canada); Meta Biomed (Chungcheongbuk-do, Korea); Rachel Endo (İstanbul, Türkiye)] were selected randomly for the present study. A specially designed metal block with a ruler and groove that enables standardizing the process of taking digital images of the samples was used for length calculation. The measurements were made starting at D0 to the indicated lines corresponding to 18, 20, and 22 mm on each sample. Three iterations of the measuring process were conducted, and the average values obtained for eachsample were considered as the final data. Data were statistically analyzed, and the significance level was set at P < .05.Results: There was a statistically significant difference between absolute variation values between actual lengths and pre-indicated lengths according to brands (P < .001). Statistically, a significant difference was also detected between length measurements in intra-manufacturer products (P < .001).Conclusion: Although the marked lines on gutta-percha cones are more trustworthy than paper points, length marks should not be used as absolute indicators, and variations should be expected.Cite this article as: Isik V, Kayahan MB. Reliability of length marks on gutta-percha cones and paper points: in vitro study. Essent Dent. 2026, 5, 0051, doi:10.5152/EssentDent.2026.25051.

  • Open Access

    Can Large Language Models Support Endodontic Decision-Making? Accuracy and Consistency of ChatGPT and Gemini in Deep Caries and Pulp Exposure

    by Vasfiye Işık, Soner Şişmanoğlu, Mehmet Baybora Kayahan

    Background: This study evaluated the accuracy and consistency of responses generated by 2 large language models (LLMs), ChatGPT and Gemini, regarding the management of deep carious lesions and pulp exposure in endodontics.Methods: Fifty dichotomous (Yes/No) questions were developed based on the position statement of the European Society of Endodontology and distributed across 5 categories: Diagnosis and Classification, Caries Management, Pulp Exposure Management, Materials and Techniques, and Follow-up and Prognosis. Questions were presented to ChatGPT-4o and Gemini (Flash 2.5) on 3 occasions, 1 week apart. A total of 300 responses were collected and compared with reference answers. Accuracy was measured as the proportion of correct responses, while consistency was assessed using Fleiss’ Kappa across time points. Statistical analyses included Cochran’s Q and McNemar’s test, with significance set at P < .05.Results: ChatGPT achieved an overall accuracy of 76.7%, while Gemini achieved 86.0%, a statistically significant difference favoring Gemini (P=.034). By categories, Gemini showed superior accuracy in Caries Management and Pulp Exposure Management (96.7%), while ChatGPT performed best in Diagnosis and Classification (93.3%). Substantial consistency was observed for both models (Fleiss’ Kappa=0.627 for ChatGPT; 0.723 for Gemini). Gemini’s accuracy varied significantly across weeks (P=.015), whereas ChatGPT’s remained stable (P=.670).Conclusion: Both LLM-based chatbots demonstrated moderate accuracy and high consistency in endodontics. While results highlight their potential as educational and decision-support tools, current performance remains insufficient for reliable clinical application. Domain-specific training and further refinement are necessary before widespread implementation in endodontic practice.Cite this article as: Işık V, Sismanoglu S, Kayahan MB. Can large language models support endodontic decision-making? Accuracy and consistency of ChatGPT and Gemini in deep caries and pulp exposure. Essent Dent. 2026, 5, 0113, doi:10.5152/EssentDent.2026.25113.

  • Evaluation of Large Language Model-Based Chatbots' Accuracy in Responding to CBCT-Related Questions in Endodontics: A Guideline-Based Assessment

    by Vasfiye Işık, Soner Şişmanoğlu

    Aim To evaluate the accuracy and guideline compliance of ChatGPT and Claude regarding the use of cone beam computed tomography (CBCT) in endodontics, based on the European Society of Endodontology (ESE) position statement: use of CBCT in endodontics.Material and method A structured question set comprising 32 true/false statements and 8 open-ended questions was developed based on the ESE position statement. Questions were reviewed by an endodontic specialist and covered four main categories: CBCT indications and justification, radiation dose and imaging parameters, technical application and image interpretation, and training requirements and clinical responsibility. ChatGPT version 5.2 and Claude 4.5 Sonnet were evaluated in separate chat sessions without chat history. All responses were evaluated by a single investigator based on the ESE criteria. Data collection was completed on January 14, 2026. Results Both ChatGPT 5.2 and Claude 4.5 Sonnet achieved an overall accuracy of 97.5% (39/40 correct responses). For true/false statements, both chatbots correctly answered 31 out of 32 questions (96.88%), with identical errors on question 23. For open-ended questions, both achieved 100% accuracy (8/8 correct). McNemar's test could not be computed due to the absence of discordant pairs, indicating perfect agreement. Chi-square analysis showed no statistically significant difference between the two chatbots (χ² = 0.000, p = 1.000).Conclusion Both ChatGPT 5.2 and Claude 4.5 Sonnet demonstrated excellent accuracy and guideline compliance regarding CBCT use in endodontics based on the ESE position statement, suggesting their potential utility for guideline-based information retrieval in dental education and clinical practice.

  • Open Access

    Accuracy and Temporal Consistency of ChatGPT and Gemini in Responding to Textbook and Patient‐Oriented Dental Bleaching Questions: A Multi‐Session Comparative Study

    by Soner Sismanoglu, Serre Sena Kotan, Vasfiye Isik

    Objective: This study compared the accuracy and temporal consistency of ChatGPT and Gemini in responding to dental bleaching questions across three weekly sessions. Materials and Methods: A total of 280 true/false questions were developed comprising 200 textbook‐based and 80 patient‐oriented frequently asked questions. Both chatbots were queried weekly under controlled conditions. Accuracy was compared using generalized estimating equations, consistency was assessed using Fleiss' kappa, and weekly stability was evaluated using Cochran's Q test. Open‐ended responses were scored for quality and misinformation by two evaluators. Results: For textbook questions, ChatGPT achieved significantly higher accuracy than Gemini (77.7% versus 70.5%, p = 0.0009). For frequently asked questions, both chatbots performed comparably (92.9% versus 90.8%, p = 0.252). Temporal consistency was only fair for textbook questions but almost perfect for frequently asked questions in both chatbots. Both chatbots showed significant upward trends in textbook accuracy across sessions. Gemini received higher global quality scores for open‐ended responses, while misinformation rates were similarly low. Conclusions: Within the limitations of this study, ChatGPT achieved significantly higher accuracy than Gemini for textbook‐based dental bleaching questions, while both chatbots performed comparably for patient‐oriented questions. Temporal consistency differed markedly, with almost perfect consistency for patient‐oriented questions and only fair consistency for textbook‐based questions. Clinical Significance: Chatbot responses to common patient questions about dental bleaching are generally accurate and consistent, but their reliability drops substantially for specialized academic content, suggesting these tools should complement rather than replace professional clinical judgment.


  • Top Cited Papers

    Evaluation of Large Language Model‐Based Chatbots for Dental Trauma Management: A Comparative Study Based on Accuracy, Consistency and Information Quality

    by Vasfiye Isik, Rana Ikbal Sengul, Soner Sismanoglu

    This study evaluated and compared the accuracy, consistency, readability, and information quality of three LLM‐based chatbots, namely ChatGPT‐5, Claude AI (Sonnet 4.0), and Perplexity (Mistral Large 2), in addressing traumatic dental injury questions. Forty true/false statements were submitted to each chatbot three times at weekly intervals to assess accuracy and consistency. Additionally, chatbot responses for 25 open‐ended case‐based questions were evaluated for readability, understandability and actionability, information reliability and quality. For true/false questions, Perplexity showed the highest accuracy, followed by Claude and ChatGPT. For open‐ended responses, ChatGPT excelled in readability (FRE: 62.4 ± 7.6), Perplexity in understandability (91.0 ± 4.3) and actionability (93.0 ± 6.4) and Claude in information reliability (mDISCERN total: 61.2; no variability observed). All chatbots achieved acceptable global quality scores (> 4.4). These findings emphasise the complementary role of chatbots in dental trauma management. Tool selection should be based on intended use, while continued human oversight remains essential in clinical decision‐making.


  • Managing Failed Fragment Reattachment: Influence of Surface Preparation and Chamfer Technique on Fracture Resistance

    by Vasfiye Isik, Soner Sismanoglu

    Background/Aim: Fragment reattachment is a conservative option for anterior crown fractures, yet failure after the initial procedure creates a clinical dilemma. Evidence on effective retreatment strategies is lacking. This study investigated how surface preparation and chamfer design influence fracture resistance and failure patterns in failed fragment reattachments. Materials and Methods: Sixty bovine mandibular incisors were sectioned 3 mm below the incisal edge and reattached using a standardized protocol with adhesive and flowable composite. After thermocycling (5000 cycles, 5°C–55°C), baseline fracture resistance was measured. Specimens were stratified by baseline values and randomly assigned to four groups ( n = 15): Group A—bur cleaning + simple reattachment, Group B—sandblasting + simple reattachment, Group C—bur cleaning + external chamfer, and Group D—sandblasting + external chamfer. Re‐reattachment used the same adhesive protocol; in Groups C and D, a 1 mm external chamfer was prepared and restored with nanohybrid composite. post‐treatment fracture resistance was tested with a universal testing machine, and percentage improvement was calculated. The specimens were examined with a stereomicroscope, and failures were categorized as adhesive, cohesive, or mixed. data were analyzed with two‐way repeated measures ANOVA , Bonferroni post hoc, and Chi‐square tests ( p < 0.05). Results: All groups showed significant increases in fracture resistance after re‐reattachment ( p < 0.05). ANOVA revealed significant effects of time, group, and time × group interaction (All p < 0.001). Group D achieved the highest post‐treatment resistance, significantly greater than all others ( p < 0.01). Group C ranked second, while Groups A and B did not differ ( p = 0.111). Failure mode distribution differed significantly ( p < 0.001); chamfer groups (C and D) showed more cohesive/mixed failures. Conclusion: External chamfer, especially combined with sandblasting, enhanced fracture resistance and shifted failure patterns, indicating a clinically promising strategy for failed fragment reattachments.


  • Reattachment or Restoration? Fracture Resistance of Uncomplicated Crown Fractures Using Various Intermediate Materials

    by Soner Sismanoglu, Vasfiye Isik

    This study aimed to evaluate the fracture resistance of different bonding materials used in fragment reattachment for uncomplicated crown fractures, compared to direct composite resin restoration. Sixty human maxillary incisors were divided into five groups ( n = 12): G1, control; G2, direct composite resin; G3, flowable composite; G4, preheated composite; G5, self‐adhesive resin cement. After simulated fractures and thermocycling, fracture resistance was tested using a universal machine. Data were analysed with one‐way ANOVA and Tukey's test (α = 0.05). G1 showed the highest resistance (75.7 ± 10.5 MPa); G2 the lowest (44.7 ± 7.9 MPa). G4 and G5 showed significantly higher resistance than G2 ( p < 0.001). No significant difference was found amongst G3–G5 ( p > 0.05). Preheated composite and self‐adhesive resin cement demonstrated improved fracture resistance compared to direct composite resin. Appropriate material selection may enhance the long‐term performance of fragment reattachment in uncomplicated crown fractures.