Tiago Paggi de Almeida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tiago Paggi de Almeida has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Diogo Coutinho Soriano
Federal University of ABC
5 shared publications - Fernando Soares Schlindwein
School of Engineering, University of Leicester, Leicester LE1 7RH, UK
4 shared publications - Ghulam AndrÉ Ng
Department of Cardiovascular Sciences, Clinical Science Wing, Glenfield Hospital, University of Leicester, Leicester LE3 9QP, UK
4 shared publications - Xin Li
Department of Engineering, University of Leicester, Leicester LE1 7RH, UK
4 shared publications - Arthur Santos Bezerra
Department of Physics and Astronomy, Ghent University, Belgium (R.V.d.A., N.C., A.S.B., B.V., S.L., K.D., A.O., T.N., S.H., N.V.).
2 shared publications - Flavia Ravelli
Laboratory of Biophysics and Translational Cardiology, Department of Cellular, Computational and Integrative Biology (CIBIO), Centre for Medical Sciences (CISMed), University of Trento, 38123 Trento, Italy
2 shared publications
Latest Publications
- Open Access
- 8 January 2025
- Published by Elsevier in JACC: Advances
- Vol. 4 (1)
Hourly Engagement Patterns of a Wearable Monitor Unveil Key Attention Windows for Hypertension Management Strategies
- 8 January 2025
- Published by Elsevier in JACC: Advances
- Vol. 4 (1)
Open AccessHourly Engagement Patterns of a Wearable Monitor Unveil Key Attention Windows for Hypertension Management Strategies
- 13 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 40, 1-4
Spatio-Temporal ECG Network for Detecting Cardiac Disorders from Multi-Lead ECGs
Automatic detection and classification of cardiac disorders play a critical role in the analysis of clinical electrocardiogram (ECG). Deep learning methods are effective for automated feature extraction and have shown promising results in ECG classification. In this work, we proposed a deep spatio-temporal ECG network (ST-ECGNet) to extract robust spatio-temporal features for detecting multiple cardiac disorders from the multi-lead ECG data. The proposed ST-ECGNet combines a Convolutional Neural Network (CNN) module for extracting local spatial features, an attention module for capturing global spatial features, and a Bi-directional Gated Recurrent Unit (Bi-GRU) module for extracting temporal features from ECG data. Specifically, the attention mechanism enables our deep learning architecture to focus on the most important and useful parts of the input to make more accurate predictions. In PhysioNet/Computing in Cardiology Challenge 2021, our entry was not officially ranked and scored on the test data of the Challenge, because our code was not successfully processed during the official phase and failed to run with errors.
- 13 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 40, 1-4
Spatio-Temporal ECG Network for Detecting Cardiac Disorders from Multi-Lead ECGs
Automatic detection and classification of cardiac disorders play a critical role in the analysis of clinical electrocardiogram (ECG). Deep learning methods are effective for automated feature extraction and have shown promising results in ECG classification. In this work, we proposed a deep spatio-temporal ECG network (ST-ECGNet) to extract robust spatio-temporal features for detecting multiple cardiac disorders from the multi-lead ECG data. The proposed ST-ECGNet combines a Convolutional Neural Network (CNN) module for extracting local spatial features, an attention module for capturing global spatial features, and a Bi-directional Gated Recurrent Unit (Bi-GRU) module for extracting temporal features from ECG data. Specifically, the attention mechanism enables our deep learning architecture to focus on the most important and useful parts of the input to make more accurate predictions. In PhysioNet/Computing in Cardiology Challenge 2021, our entry was not officially ranked and scored on the test data of the Challenge, because our code was not successfully processed during the official phase and failed to run with errors.
- Open Access
- 30 December 2020
- Published by Computing in Cardiology
Optimizing Atrial Electrogram Classification Based on Local Ablation Outcome in Human Atrial Fibrillation
- 30 December 2020
- Published by Computing in Cardiology
Open AccessOptimizing Atrial Electrogram Classification Based on Local Ablation Outcome in Human Atrial Fibrillation
- Open Access
- 3 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (4) , 1131-1141
Unsupervised Classification of Atrial Electrograms for Electroanatomic Mapping of Human Persistent Atrial Fibrillation
Objective: Ablation treatment for persistent atrial fibrillation (persAF) remains challenging due to the absence of a ‘ground truth’ for atrial substrate characterization and the presence of multiple mechanisms driving the arrhythmia. We implemented an unsupervised classification to identify clusters of atrial electrograms (AEGs) with similar patterns, which were then validated by AEG-derived markers. Methods : 956 bipolar AEGs were collected from 11 persAF patients. CARTO variables (Biosense Webster; ICL, ACI and SCI) were used to create a 3D space, and subsequently used to perform an unsupervised classification with k-means. The characteristics of the identified groups were investigated using nine AEG-derived markers: sample entropy (SampEn), dominant frequency, organization index (OI), determinism, laminarity, recurrence rate (RR), peak-to-peak (PP) amplitude, cycle length (CL), and wave similarity (WS). Results : Five AEG classes with distinct characteristics were identified (F = 582, P<0.0001). The presence of fractionation increased from class 1 to 5, as reflected by the nine markers. Class 1 (25%) included organized AEGs with high WS, determinism, laminarity, and RR, and low SampEn. Class 5 (20%) comprised fractionated AEGs with in low WS, OI, determinism, laminarity, and RR, and in high SampEn. Classes 2 (12%), 3 (13%) and 4 (30%) suggested different degrees of AEG organization. Conclusions : Our results expand and reinterpret the criteria used for automated AEG classification. The nine markers highlighted electrophysiological differences among the five classes found by the k-means, which could provide a more complete characterization of persAF substrate during ablation target identification in future clinical studies.
- 3 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (4) , 1131-1141
Open AccessUnsupervised Classification of Atrial Electrograms for Electroanatomic Mapping of Human Persistent Atrial Fibrillation
Objective: Ablation treatment for persistent atrial fibrillation (persAF) remains challenging due to the absence of a ‘ground truth’ for atrial substrate characterization and the presence of multiple mechanisms driving the arrhythmia. We implemented an unsupervised classification to identify clusters of atrial electrograms (AEGs) with similar patterns, which were then validated by AEG-derived markers. Methods : 956 bipolar AEGs were collected from 11 persAF patients. CARTO variables (Biosense Webster; ICL, ACI and SCI) were used to create a 3D space, and subsequently used to perform an unsupervised classification with k-means. The characteristics of the identified groups were investigated using nine AEG-derived markers: sample entropy (SampEn), dominant frequency, organization index (OI), determinism, laminarity, recurrence rate (RR), peak-to-peak (PP) amplitude, cycle length (CL), and wave similarity (WS). Results : Five AEG classes with distinct characteristics were identified (F = 582, P<0.0001). The presence of fractionation increased from class 1 to 5, as reflected by the nine markers. Class 1 (25%) included organized AEGs with high WS, determinism, laminarity, and RR, and low SampEn. Class 5 (20%) comprised fractionated AEGs with in low WS, OI, determinism, laminarity, and RR, and in high SampEn. Classes 2 (12%), 3 (13%) and 4 (30%) suggested different degrees of AEG organization. Conclusions : Our results expand and reinterpret the criteria used for automated AEG classification. The nine markers highlighted electrophysiological differences among the five classes found by the k-means, which could provide a more complete characterization of persAF substrate during ablation target identification in future clinical studies.
- Open Access
- 28 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (3) , 914-925
Non-Invasive Characterization of Atrial Flutter Mechanisms Using Recurrence Quantification Analysis on the ECG: A Computational Study
Objective: Atrial flutter (AFl) is a common arrhythmia that can be categorized according to different self-sustained electrophysiological mechanisms. The non-invasive discrimination of such mechanisms would greatly benefit ablative methods for AFl therapy as the driving mechanisms would be described prior to the invasive procedure, helping to guide ablation. In the present work, we sought to implement recurrence quantification analysis (RQA) on 12-lead ECG signals from a computational framework to discriminate different electrophysiological mechanisms sustaining AFl. Methods: 20 different AFl mechanisms were generated in 8 atrial models and were propagated into 8 torso models via forward solution, resulting in 1,256 sets of 12-lead ECG signals. Principal component analysis was applied on the 12-lead ECGs, and six RQA-based features were extracted from the most significant principal component scores in two different approaches: individual component RQA and spatial reduced RQA. Results: In both approaches, RQA-based features were significantly sensitive to the dynamic structures underlying different AFl mechanisms. Hit rate as high as 67.7% was achieved when discriminating the 20 AFl mechanisms. RQA-based features estimated for a clinical sample suggested high agreement with the results found in the computational framework. Conclusion: RQA has been shown an effective method to distinguish different AFl electrophysiological mechanisms in a non-invasive computational framework. A clinical 12-lead ECG used as proof of concept showed the value of both the simulations and the methods. Significance: The non-invasive discrimination of AFl mechanisms helps to delineate the ablation strategy, reducing time and resources required to conduct invasive cardiac mapping and ablation procedures.
- 28 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (3) , 914-925
Open AccessNon-Invasive Characterization of Atrial Flutter Mechanisms Using Recurrence Quantification Analysis on the ECG: A Computational Study
Objective: Atrial flutter (AFl) is a common arrhythmia that can be categorized according to different self-sustained electrophysiological mechanisms. The non-invasive discrimination of such mechanisms would greatly benefit ablative methods for AFl therapy as the driving mechanisms would be described prior to the invasive procedure, helping to guide ablation. In the present work, we sought to implement recurrence quantification analysis (RQA) on 12-lead ECG signals from a computational framework to discriminate different electrophysiological mechanisms sustaining AFl. Methods: 20 different AFl mechanisms were generated in 8 atrial models and were propagated into 8 torso models via forward solution, resulting in 1,256 sets of 12-lead ECG signals. Principal component analysis was applied on the 12-lead ECGs, and six RQA-based features were extracted from the most significant principal component scores in two different approaches: individual component RQA and spatial reduced RQA. Results: In both approaches, RQA-based features were significantly sensitive to the dynamic structures underlying different AFl mechanisms. Hit rate as high as 67.7% was achieved when discriminating the 20 AFl mechanisms. RQA-based features estimated for a clinical sample suggested high agreement with the results found in the computational framework. Conclusion: RQA has been shown an effective method to distinguish different AFl electrophysiological mechanisms in a non-invasive computational framework. A clinical 12-lead ECG used as proof of concept showed the value of both the simulations and the methods. Significance: The non-invasive discrimination of AFl mechanisms helps to delineate the ablation strategy, reducing time and resources required to conduct invasive cardiac mapping and ablation procedures.
- 4 December 2019
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 31 (1) , 373-374
Pitfalls in the definition of complex fractionated atrial electrograms for atrial fibrillation studies
- 4 December 2019
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 31 (1) , 373-374
Pitfalls in the definition of complex fractionated atrial electrograms for atrial fibrillation studies