Michał Jedynak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michał Jedynak has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Konrad Kobiela
Laboratory of Coordinate Metrology, Cracow University of Technology, al. Jana Pawla II 37, 31-864 Krakow, Poland
3 shared publications - Adam Gąska
Faculty of Mechanical Engineering, Cracow University of Technology, 31-864 Cracow, Poland
2 shared publications - Maciej Gruza
Cracow University of Technology
2 shared publications - Piotr Gąska
AGH University of Krakow
2 shared publications - Wiktor Harmatys
Cracow University of Technology
2 shared publications - Jerzy Sładek
Mechanical Faculty, Cracow University of Technology, Jana Pawła II 37 Avenue, 31-864 Krakow, Poland
1 shared publication
Latest Publications
- Open Access
Applicability Assessment of Different Materials for Standards Ensuring Comparability of Optical and Tactile Coordinate Measurements
Multisensor CMMs are systems with an established position on the market, but their popularity still grows, as they provide access to the advantages offered by tactile and contactless measurement methods. Yet there are still questions of the comparability of results obtained using the optical and tactile operation modes of multisensor system. This phenomenon can be assessed by measuring appropriate gauges, most often reference rings or spheres. Due to the completely different nature of probing processes for tactile and contactless measurements, the material from which reference object is made may significantly affect measurement results. In order to assess the influence of this factor on measurement accuracy, three reference spheres made from different materials were measured on optical multisensor CMMs. Measurements involved tactile measurements as well as optical measurements made using different probing systems: a video probe and white light sensor. Results obtained from performed experiments show large differences depending on the material used for spherical standard production. On the basis of obtained results, it can be stated that the best material for a reference object that can be used for comparability tests of tactile and optical measurements is a composite of alumina with at least one oxidic additive.
Open AccessApplicability Assessment of Different Materials for Standards Ensuring Comparability of Optical and Tactile Coordinate Measurements
Multisensor CMMs are systems with an established position on the market, but their popularity still grows, as they provide access to the advantages offered by tactile and contactless measurement methods. Yet there are still questions of the comparability of results obtained using the optical and tactile operation modes of multisensor system. This phenomenon can be assessed by measuring appropriate gauges, most often reference rings or spheres. Due to the completely different nature of probing processes for tactile and contactless measurements, the material from which reference object is made may significantly affect measurement results. In order to assess the influence of this factor on measurement accuracy, three reference spheres made from different materials were measured on optical multisensor CMMs. Measurements involved tactile measurements as well as optical measurements made using different probing systems: a video probe and white light sensor. Results obtained from performed experiments show large differences depending on the material used for spherical standard production. On the basis of obtained results, it can be stated that the best material for a reference object that can be used for comparability tests of tactile and optical measurements is a composite of alumina with at least one oxidic additive.
- Open Access
- 25 September 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (19) , 8929
Assessment of Laser Galvanometer Scanning System Accuracy Using Ball-Bar Standard
The laser projector based on the laser galvanometer scanning system enables the projection of CAD-based laser images onto geometrical objects. Furthermore, the system can perform a scan of components in order to control proper positioning (e.g., welded structures). We decided to conduct research aimed at determining the suitability of such systems for length measurements and assess their accuracy. These systems are commonly calibrated with the use of flat calibration boards, although their capability of projecting and scanning 3D objects. For this reason, a new method based on ISO 10360 has been proposed. Analysis of the system’s ability to perform length measurements, selection of a reference standard, and the tested device accuracy were the main objectives of the study. A ball-bar with a nominal length of 3000 mm was chosen as a reference standard. Positions of the reference element in the workspace were determined, and three series of five measured deviations were performed in each setting. The obtained values of measurement errors prove that it is possible to use ball-bar standards to assess the accuracy of the described systems, which is defined by the equation MPE(E0) = ±0.5 mm. The proposed method could be adapted to perform more complex analyzes in this area.
- 25 September 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (19) , 8929
Open AccessAssessment of Laser Galvanometer Scanning System Accuracy Using Ball-Bar Standard
The laser projector based on the laser galvanometer scanning system enables the projection of CAD-based laser images onto geometrical objects. Furthermore, the system can perform a scan of components in order to control proper positioning (e.g., welded structures). We decided to conduct research aimed at determining the suitability of such systems for length measurements and assess their accuracy. These systems are commonly calibrated with the use of flat calibration boards, although their capability of projecting and scanning 3D objects. For this reason, a new method based on ISO 10360 has been proposed. Analysis of the system’s ability to perform length measurements, selection of a reference standard, and the tested device accuracy were the main objectives of the study. A ball-bar with a nominal length of 3000 mm was chosen as a reference standard. Positions of the reference element in the workspace were determined, and three series of five measured deviations were performed in each setting. The obtained values of measurement errors prove that it is possible to use ball-bar standards to assess the accuracy of the described systems, which is defined by the equation MPE(E0) = ±0.5 mm. The proposed method could be adapted to perform more complex analyzes in this area.
- Open Access
- 1 December 2019
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 13 (4) , 94-99
Assessment of Influence of Sample Averaging on Accuracy of Point Coordinates Measurement Performed Using Laser Tracking Systems
Laser Tracking systems are commonly used in all brunches of industry which requires accurate large-scale measurements for instance aviation, space and shipbuilding industries. Laser Trackers belong to the group of non-Cartesian Coordinate Measuring Systems. The determination of measured point...
- 1 December 2019
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 13 (4) , 94-99
Open AccessAssessment of Influence of Sample Averaging on Accuracy of Point Coordinates Measurement Performed Using Laser Tracking Systems
Laser Tracking systems are commonly used in all brunches of industry which requires accurate large-scale measurements for instance aviation, space and shipbuilding industries. Laser Trackers belong to the group of non-Cartesian Coordinate Measuring Systems. The determination of measured point...