Manjunath Kallamadi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Krupa Shah
Institute of Infrastructure Technology, Research and Management IITRAM Maninagar Ahmedabad Gujarat 380026 India
3 shared publications V. Sarkar
Department of Electrical Engineering, IIT Hyderabad, Kandi
3 shared publications- Rajesh Reddy
Electrical and Computer Science Engineering, Institute of Infrastructure, Technology, Research and Management (IITRAM), Ahmedabad, India
2 shared publications Vaskar Sarkar
Department of Electrical Engineering Indian Institute of Technology Hyderabad India
2 shared publicationsAmarjeet S Pandey
Electrical and Computer Science Engineering Institute of Infrastructure Technology Research and Management (IITRAM) Ahmedabad Gujarat India
1 shared publication- Amarjeet S. Pandey
IITRAM
1 shared publication
Latest Publications
- 25 March 2025
- Published by Springer Nature
- p. 97-108
Holistic View of P-Q Characteristics of Solar PV Driven Voltage Source Converter
- 25 March 2025
- Published by Springer Nature
- p. 97-108
Holistic View of P-Q Characteristics of Solar PV Driven Voltage Source Converter
- Open Access
- 10 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 23 (3) , 223-231
Hybrid Attack Optimization Supported Enhanced Deep Learning to Facilitate Power System Event Detection using PMU Data
Accurate event detection is crucial for initiating control and protection measures in power systems to ensure enhanced and reliable operation. Phasor measurement units (PMUs) play a vital role in various functional aspects of power systems, including state estimation and intelligent protection algorithms. However, the authenticity of real-time data from PMUs must be verified before feeding it into applicable real-time algorithms to prevent undesirable or erroneous operations. This paper aims to present an efficient preprocessing methodology for identifying unwanted, incorrect, missing, or noisy PMU data to facilitate robust event detection algorithms. The proposed methodology leverages real-time data-driven deep learning techniques for authenticating incoming data. Given the high sampling rate of PMUs, the presence of extraneous data can lead to false event detection, necessitating reliable data preprocessing. Challenges identified in existing literature, such as the limitations of Steady State (SS)-Local Outlier Factor (LOF) in event detection and classification, issues with detecting line tripping and inter-area oscillations, computational and bandwidth requirements for micro-PMU installations, and false alarms resulting from inaccuracies in frequency ramp rate determination, are addressed. To overcome these challenges, this research proposes a deep learning approach that utilizes modified Deep Convolutional Neural Network (CNN) and Long Short-Term Memory (LSTM) classifiers to classify and extract features from PMU data, enabling highly efficient detection of disturbances in transmission lines. Additionally, a hybrid attack optimization (HAO) technique is employed to enhance convergence rates, accuracy, and efficiency. Performance evaluation of the proposed system is conducted by calculating and assessing disturbances generated by power lines using metrics such as accuracy, precision, recall, System Average Interruption Duration Index (SAIDI), and System Average Interruption Frequency Index (SAIFI).
- 10 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 23 (3) , 223-231
Open AccessHybrid Attack Optimization Supported Enhanced Deep Learning to Facilitate Power System Event Detection using PMU Data
Accurate event detection is crucial for initiating control and protection measures in power systems to ensure enhanced and reliable operation. Phasor measurement units (PMUs) play a vital role in various functional aspects of power systems, including state estimation and intelligent protection algorithms. However, the authenticity of real-time data from PMUs must be verified before feeding it into applicable real-time algorithms to prevent undesirable or erroneous operations. This paper aims to present an efficient preprocessing methodology for identifying unwanted, incorrect, missing, or noisy PMU data to facilitate robust event detection algorithms. The proposed methodology leverages real-time data-driven deep learning techniques for authenticating incoming data. Given the high sampling rate of PMUs, the presence of extraneous data can lead to false event detection, necessitating reliable data preprocessing. Challenges identified in existing literature, such as the limitations of Steady State (SS)-Local Outlier Factor (LOF) in event detection and classification, issues with detecting line tripping and inter-area oscillations, computational and bandwidth requirements for micro-PMU installations, and false alarms resulting from inaccuracies in frequency ramp rate determination, are addressed. To overcome these challenges, this research proposes a deep learning approach that utilizes modified Deep Convolutional Neural Network (CNN) and Long Short-Term Memory (LSTM) classifiers to classify and extract features from PMU data, enabling highly efficient detection of disturbances in transmission lines. Additionally, a hybrid attack optimization (HAO) technique is employed to enhance convergence rates, accuracy, and efficiency. Performance evaluation of the proposed system is conducted by calculating and assessing disturbances generated by power lines using metrics such as accuracy, precision, recall, System Average Interruption Duration Index (SAIDI), and System Average Interruption Frequency Index (SAIFI).
- 20 October 2024
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 53 (6) , 3778-3786
Cascaded AC–DC Voltage Control to Provide Reactive Power Support for the PV‐Driven Grid‐Tied Synchronverter
The objective of this submission is to provide flexible reactive power regulation of a photovoltaic (PV)‐driven grid‐connected inverter. Here, inverter is realized as a synchronverter by employing frequency regulation using well‐established swing equation. However, reactive power regulation is accomplished by employing combined AC–DC voltage control in addition to traditional synchronverter control for ensuring smooth tracking of reactive power. Thus, the PV‐driven voltage source converter (VSC) will be injecting available active power as per the prevailing irradiation, temperature, and operator defined reactive power by employing proposed control. The performance of suggested control is evaluated and compared against existing control by considering realistic operational scenarios through a case study.
- 20 October 2024
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 53 (6) , 3778-3786
Cascaded AC–DC Voltage Control to Provide Reactive Power Support for the PV‐Driven Grid‐Tied Synchronverter
The objective of this submission is to provide flexible reactive power regulation of a photovoltaic (PV)‐driven grid‐connected inverter. Here, inverter is realized as a synchronverter by employing frequency regulation using well‐established swing equation. However, reactive power regulation is accomplished by employing combined AC–DC voltage control in addition to traditional synchronverter control for ensuring smooth tracking of reactive power. Thus, the PV‐driven voltage source converter (VSC) will be injecting available active power as per the prevailing irradiation, temperature, and operator defined reactive power by employing proposed control. The performance of suggested control is evaluated and compared against existing control by considering realistic operational scenarios through a case study.
- 19 August 2023
- Published by Springer Nature in Iranian Journal of Science and Technology, Transactions of Electrical Engineering
- Vol. 48 (1) , 187-199
Performance Evaluation of Laboratory and Industrial Equipment in FRA Measurement
- 19 August 2023
- Published by Springer Nature in Iranian Journal of Science and Technology, Transactions of Electrical Engineering
- Vol. 48 (1) , 187-199
Performance Evaluation of Laboratory and Industrial Equipment in FRA Measurement
- 14 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 21 (3) , 490-497
Towards Unique Circuit Synthesis of Power Transformer Winding Using Gradient and Population Based Methods
The aim of the paper is to synthesize a nearly unique, physically realizable and mutually coupled ladder circuit representation of a two-winding transformer by identifying the most accurate and reliable optimization technique such that prior knowledge in selecting the initial guess and search space is avoided. To this end, magnitude and phase of the driving-point impedance function are captured by performing sweep frequency response analysis (SFRA). Then, two widely used population-based algorithms namely, particle swarm optimization (PSO) and artificial bee colony (ABC) and one gradient-based sequential quadratic programming (SQP) algorithm are implemented. Two case studies are considered namely, i) 15 MVA, 66/11.55 kV transformer and, ii) 111 kVA, 7.33/1.22 kV transformer. The performance of the aforementioned algorithms is compared using three evaluation parameters namely, repeatability, accuracy and reliability
- 14 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 21 (3) , 490-497
Towards Unique Circuit Synthesis of Power Transformer Winding Using Gradient and Population Based Methods
The aim of the paper is to synthesize a nearly unique, physically realizable and mutually coupled ladder circuit representation of a two-winding transformer by identifying the most accurate and reliable optimization technique such that prior knowledge in selecting the initial guess and search space is avoided. To this end, magnitude and phase of the driving-point impedance function are captured by performing sweep frequency response analysis (SFRA). Then, two widely used population-based algorithms namely, particle swarm optimization (PSO) and artificial bee colony (ABC) and one gradient-based sequential quadratic programming (SQP) algorithm are implemented. Two case studies are considered namely, i) 15 MVA, 66/11.55 kV transformer and, ii) 111 kVA, 7.33/1.22 kV transformer. The performance of the aforementioned algorithms is compared using three evaluation parameters namely, repeatability, accuracy and reliability
- 14 December 2021
- Published by Springer Nature
- p. 253-260
A Preliminary Study on PLL-Based Frequency Extraction of an Unbalanced Voltage Signal
- 14 December 2021
- Published by Springer Nature
- p. 253-260
A Preliminary Study on PLL-Based Frequency Extraction of an Unbalanced Voltage Signal
- 4 December 2019
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 30 (3)
Angle measurement–based compensation methodology to mitigate voltage unbalance in a distribution system
- 4 December 2019
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 30 (3)
Angle measurement–based compensation methodology to mitigate voltage unbalance in a distribution system
- 29 September 2018
- Published by Springer Nature
- p. 21-31
Parameter Validation to Ascertain Voltage of Li-ion Battery Through Adaptive Control
- 29 September 2018
- Published by Springer Nature
- p. 21-31
Parameter Validation to Ascertain Voltage of Li-ion Battery Through Adaptive Control
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 93-98
Performance assessment of different droop control techniques in an AC microgrid
The objective of this paper is to evaluate the performances of different droop control technologies that are proposed in literature for the real-time power balancing in a microgrid. Mainly, the decentralized droop control techniques are studied. The different attributes of the droop control are identified. Droop controllers are synthesized by considering all possible cases of an attribute. The generalized control architectures are presented based upon the broad classification of droop controllers. Extensive case studies are performed to verify the pros and cons of the selection of a particular feature in the droop controller. Both the transient and steady-state performances are evaluated.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 93-98
Performance assessment of different droop control techniques in an AC microgrid
The objective of this paper is to evaluate the performances of different droop control technologies that are proposed in literature for the real-time power balancing in a microgrid. Mainly, the decentralized droop control techniques are studied. The different attributes of the droop control are identified. Droop controllers are synthesized by considering all possible cases of an attribute. The generalized control architectures are presented based upon the broad classification of droop controllers. Extensive case studies are performed to verify the pros and cons of the selection of a particular feature in the droop controller. Both the transient and steady-state performances are evaluated.
- Open Access
- 7 June 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (8) , 1933-1942
Enhanced real‐time power balancing of an AC microgrid through transiently coupled droop control
The objective of this study is to improve the real‐time operation of an AC microgrid for a network with high line R / X ratios. In specific, it is intended to achieve a stable microgrid operation along with accurate power sharing and minimal steady‐state frequency deviation following a load disturbance. A novel droop control (DC) methodology is proposed in this regard. For a network with high line R / X ratios, there exists coupling between active power and reactive power. In existing power transformation‐based approaches, the actual power sharing among different sources remains variable though both the system stability and the steady‐state frequency profile can be excellent. In the DC methodology proposed, the concept of power transformation is replaced with direct power versus voltage and reactive power versus frequency droop equations. However, the active power versus voltage and reactive power versus frequency cross‐couplings are taken into account only during the transient period. Therefore, the steady‐state power sharing takes place in the similar manner as in the case of the normal decoupled DC. All the droop parameters are independently tuned optimising the stability performance of the system. The robustness of the proposed methodology is verified through a detailed case study.
- 7 June 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (8) , 1933-1942
Open AccessEnhanced real‐time power balancing of an AC microgrid through transiently coupled droop control
The objective of this study is to improve the real‐time operation of an AC microgrid for a network with high line R / X ratios. In specific, it is intended to achieve a stable microgrid operation along with accurate power sharing and minimal steady‐state frequency deviation following a load disturbance. A novel droop control (DC) methodology is proposed in this regard. For a network with high line R / X ratios, there exists coupling between active power and reactive power. In existing power transformation‐based approaches, the actual power sharing among different sources remains variable though both the system stability and the steady‐state frequency profile can be excellent. In the DC methodology proposed, the concept of power transformation is replaced with direct power versus voltage and reactive power versus frequency droop equations. However, the active power versus voltage and reactive power versus frequency cross‐couplings are taken into account only during the transient period. Therefore, the steady‐state power sharing takes place in the similar manner as in the case of the normal decoupled DC. All the droop parameters are independently tuned optimising the stability performance of the system. The robustness of the proposed methodology is verified through a detailed case study.