Sébastien Merlet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sébastien Merlet has a total of 349 co-authors. Here are the top co-authors by number of shared publications:
- Franck Pereira Dos Santos
Observatoire de Paris
48 shared publications - Arnaud Landragin
LTE LNE Observatoire de Paris Université PSL Sorbonne Université Université de Lille CNRS 61 Avenue de l'Observatoire 75014 Paris France
23 shared publications P. Gillot
LNE-SYRTE Observatoire de Paris Université PSL CNRS Sorbonne Université 61 Avenue de l'Observatoire 75014 Paris France
7 shared publicationsBruno Desruelle
6 shared publicationsFranck Pereira Dos Santos
6 shared publicationsFranck Pereira dos Santos
6 shared publications
Latest Publications
- 24 August 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (2)
Impact of light-shift inhomogeneities on the contrast of light-pulse atom interferometers
- 24 August 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (2)
Impact of light-shift inhomogeneities on the contrast of light-pulse atom interferometers
- Open Access
- 2 April 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (7) , 13285-13304
Rejection of wavefront aberrations in an atomic gradiometer
One of the main residual limitations of inertial sensors based on atom interferometry stems from laser beam distortions, which cause parasitic phase shifts and non-homogeneous matter-light couplings. Here we present numerical simulations, accompanied by analytical calculations, which quantify the impact of these effects in a cold atom gradiometer. We demonstrate that the propagation of interferometric laser beam aberrations, combined with initial asymmetry and significant time-of-flight expansion of the two atomic sources, limit the common-mode rejection of phase noise in a differential configuration. The resulting deviations in gravitational acceleration and its gradient are within reach of current experimental devices. Our study allows us to evaluate the surface quality requirements for retroreflective optics in cold-atom gradiometers of various baselines, and can be extended to other sensors based on different interferometer geometries.
- 2 April 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (7) , 13285-13304
Open AccessRejection of wavefront aberrations in an atomic gradiometer
One of the main residual limitations of inertial sensors based on atom interferometry stems from laser beam distortions, which cause parasitic phase shifts and non-homogeneous matter-light couplings. Here we present numerical simulations, accompanied by analytical calculations, which quantify the impact of these effects in a cold atom gradiometer. We demonstrate that the propagation of interferometric laser beam aberrations, combined with initial asymmetry and significant time-of-flight expansion of the two atomic sources, limit the common-mode rejection of phase noise in a differential configuration. The resulting deviations in gravitational acceleration and its gradient are within reach of current experimental devices. Our study allows us to evaluate the surface quality requirements for retroreflective optics in cold-atom gradiometers of various baselines, and can be extended to other sensors based on different interferometer geometries.
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
Quantum sensor testing activities within EQUIP-G project
Aligned with the objective of strengthening EU’s strategic autonomy and competitiveness, the Horizon Europe project EQUIP-G [1] started in June 2025. The main objective is to establish a European perennial Research Infrastructure managing a shared park of quantum sensors and a terrestrial reference gravity network. Ten absolute commercially available quantum sensors will be acquired: seven gravimeters, two dual gravi-gradiometers and one onboarded gravimeter. Some activities of the project aim to provide comprehensive quality control to all these new instruments, and traceability over time and use cases to ensure a consistent park of instruments. This includes consolidation of measurement protocols and quantum sensor validation.Every instrument will be tested as comprehensively as possible at LNE, the French National Metrological Institute, which is already involved in the implementation of the RIA Qu-Test project [2]. At this site, a reference gravimetric station has been operational and monitored with state-of-the-art gravity instrumentation since 2003. It is part of MetriQs-France platform [3] and allows the concurrent installation of six mobile gravimeters at the same time.The first tests are carried out in a laboratory environment and are followed by outdoor tests. This allows to characterize each instrument and detect any faults, before sending it out for deployment under field conditions to run the measurement activities within planned project use cases. One of these use cases involves the installation of a network of quantum gravimeters at the O-ZNS site, 100 km away from LNE. In addition to the importance of this use case for the project, the fact that the two sites are close to each other allow us to extend the tests on each instrument with the execution of field measurement at O-ZNS.In order to guarantee the quality of the measurements carried out in the frame of the different EQUIP-G use cases and to ensure the traceability and quality of the measurements from the gravimeters, two absolute comparisons will be organized in 2026 and 2028. They involve other absolute gravimeters, owned by consortium partners, which have taken part in all metrological International KC and European (EURAMET) comparisons in the last 20 years. In addition, the LNE-OP/LTE and UBER self-made laboratory quantum instruments will participate in the final comparison, which will strengthen the evaluation of the final results, in particular through the comparison of sensors based on different technologies and tested to the state-of-the-art level of performance.These testing and metrology activities of EQUIP-G project will be presented in the poster.EQUIP-G project is funded by the European Commission under the Horizon Europe program, grant number 101215427[1] https://www.equip-g.eu[2] https://qu-test.eu[3] https://www.lne.fr/fr/metriqs-france/plateforme-hub
- 14 March 2026
- Published by Copernicus GmbH
Open AccessQuantum sensor testing activities within EQUIP-G project
Aligned with the objective of strengthening EU’s strategic autonomy and competitiveness, the Horizon Europe project EQUIP-G [1] started in June 2025. The main objective is to establish a European perennial Research Infrastructure managing a shared park of quantum sensors and a terrestrial reference gravity network. Ten absolute commercially available quantum sensors will be acquired: seven gravimeters, two dual gravi-gradiometers and one onboarded gravimeter. Some activities of the project aim to provide comprehensive quality control to all these new instruments, and traceability over time and use cases to ensure a consistent park of instruments. This includes consolidation of measurement protocols and quantum sensor validation.Every instrument will be tested as comprehensively as possible at LNE, the French National Metrological Institute, which is already involved in the implementation of the RIA Qu-Test project [2]. At this site, a reference gravimetric station has been operational and monitored with state-of-the-art gravity instrumentation since 2003. It is part of MetriQs-France platform [3] and allows the concurrent installation of six mobile gravimeters at the same time.The first tests are carried out in a laboratory environment and are followed by outdoor tests. This allows to characterize each instrument and detect any faults, before sending it out for deployment under field conditions to run the measurement activities within planned project use cases. One of these use cases involves the installation of a network of quantum gravimeters at the O-ZNS site, 100 km away from LNE. In addition to the importance of this use case for the project, the fact that the two sites are close to each other allow us to extend the tests on each instrument with the execution of field measurement at O-ZNS.In order to guarantee the quality of the measurements carried out in the frame of the different EQUIP-G use cases and to ensure the traceability and quality of the measurements from the gravimeters, two absolute comparisons will be organized in 2026 and 2028. They involve other absolute gravimeters, owned by consortium partners, which have taken part in all metrological International KC and European (EURAMET) comparisons in the last 20 years. In addition, the LNE-OP/LTE and UBER self-made laboratory quantum instruments will participate in the final comparison, which will strengthen the evaluation of the final results, in particular through the comparison of sensors based on different technologies and tested to the state-of-the-art level of performance.These testing and metrology activities of EQUIP-G project will be presented in the poster.EQUIP-G project is funded by the European Commission under the Horizon Europe program, grant number 101215427[1] https://www.equip-g.eu[2] https://qu-test.eu[3] https://www.lne.fr/fr/metriqs-france/plateforme-hub
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
Improving performances of LNE-OP/LTE Cold Atom Gravimeter
Atom gravimeters based on atom interferometry offer measurement capabilities, by combining high sensitivities and accuracies at the best level of a few tens of nm s−2 with the possibility to perform continuous measurements. Being absolute meters, their scale factor is accurately determined and do not need calibration.We have developed a laboratory state-of-the-art cold atom gravimeter (CAG). The measurement is based on atomic interferometry techniques using stimulated Raman transitions on free-falling 87Rb atoms. The phase shift of the atomic interferometer is proportional to g, the acceleration due to gravity, which we measure with a sensitivity greater than that of conventional absolute gravimeters (5.7ng/rac(Hz)) and with greater accuracy (2ng).The instrument being movable, participated to international comparisons since 2009 and became the French reference standard. Its limitations have been identified and several improvements are ongoing to achieve the 10-10 range in terms of accuracy and stability. It will then come back to the reference gravimetric station at LNE, the French National Metrological Institute. These activities take part the European Qu-Test project [1] and of MetriQs-France platform [2].The poster will present the instrument and improvements and next steps from tests and metrology characterization to its involvement in the European project EQUIP-G [3] as it will participate to the project final comparison in 2028. Qu-Test project is funded by the European Commission under the Horizon Europe program, grant number 101112931EQUIP-G project is funded by the European Commission under the Horizon Europe program, grant number 101215427 [1] https://qu-test.eu[2] https://www.lne.fr/fr/metriqs-france/plateforme-hub[3] https://www.equip-g.eu
- 14 March 2026
- Published by Copernicus GmbH
Open AccessImproving performances of LNE-OP/LTE Cold Atom Gravimeter
Atom gravimeters based on atom interferometry offer measurement capabilities, by combining high sensitivities and accuracies at the best level of a few tens of nm s−2 with the possibility to perform continuous measurements. Being absolute meters, their scale factor is accurately determined and do not need calibration.We have developed a laboratory state-of-the-art cold atom gravimeter (CAG). The measurement is based on atomic interferometry techniques using stimulated Raman transitions on free-falling 87Rb atoms. The phase shift of the atomic interferometer is proportional to g, the acceleration due to gravity, which we measure with a sensitivity greater than that of conventional absolute gravimeters (5.7ng/rac(Hz)) and with greater accuracy (2ng).The instrument being movable, participated to international comparisons since 2009 and became the French reference standard. Its limitations have been identified and several improvements are ongoing to achieve the 10-10 range in terms of accuracy and stability. It will then come back to the reference gravimetric station at LNE, the French National Metrological Institute. These activities take part the European Qu-Test project [1] and of MetriQs-France platform [2].The poster will present the instrument and improvements and next steps from tests and metrology characterization to its involvement in the European project EQUIP-G [3] as it will participate to the project final comparison in 2028. Qu-Test project is funded by the European Commission under the Horizon Europe program, grant number 101112931EQUIP-G project is funded by the European Commission under the Horizon Europe program, grant number 101215427 [1] https://qu-test.eu[2] https://www.lne.fr/fr/metriqs-france/plateforme-hub[3] https://www.equip-g.eu
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
Terrestrial and onboard use cases to demonstrate quantum gravimetry within the EQUIP-G project
EQUIP-G aims at demonstrating the possibilities of quantum gravimeters through the execution of continuous and repeated observation in Europe, under different geological and geodynamical settings.To showcase the possibilities enabled by quantum gravimeters when used to address geophysical challenges and the advantages they may offer with respect to devices based on other technologies (spring and superconducting relative gravimeters, free fall corner cube absolute gravimeters), several use cases (UCs) will be carried out during the course of the project. When defining the set of project UCs, the EQUIP-G consortium took into account different perspectives, including the need to tackle urgent and relevant societal topics (e.g., management of natural risks and resources) and the time scale of the gravity changes produced by the phenomena in the target of the different UCs, which must be compatible with the duration of the project.In the frame of EQUIP-G’s terrestrial use cases (TUCs), quantum gravimetry will be applied to hydrology, volcanology, climatology, geothermic, and geodesy. In particular, among the eight TUCs that will be implemented, two deal with hydrological processes, two focus on time gravity changes developing at active volcanoes, one involves activities framed within the safety analysis of geological repositories for nuclear waste, one focuses on climate monitoring, one is devoted to demonstrating the applicability of quantum gravimetry to geothermal reservoir monitoring, one will be undertaken to assess the feasibility and advantages of using quantum devices for the execution of gravity surveys over extended areas.Furthermore, two onboard use cases (OBUCs) will be carried out. OBUC1 aims to demonstrate mobile gravity mapping onboard a fixed-wing aircraft, using a commercial quantum sensor in combination with high-quality GNSS observations. OBUC2 will be implemented using an innovative airship platform, instead of the fixed-wing aircraft. Since measurements must be averaged in time, a slow-moving platform will result in higher resolution of the spatial mapping.Here we provide a description of the EQUIP-G’s UCs, including how each of them will contribute to the assessment of the project’s goals.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessTerrestrial and onboard use cases to demonstrate quantum gravimetry within the EQUIP-G project
EQUIP-G aims at demonstrating the possibilities of quantum gravimeters through the execution of continuous and repeated observation in Europe, under different geological and geodynamical settings.To showcase the possibilities enabled by quantum gravimeters when used to address geophysical challenges and the advantages they may offer with respect to devices based on other technologies (spring and superconducting relative gravimeters, free fall corner cube absolute gravimeters), several use cases (UCs) will be carried out during the course of the project. When defining the set of project UCs, the EQUIP-G consortium took into account different perspectives, including the need to tackle urgent and relevant societal topics (e.g., management of natural risks and resources) and the time scale of the gravity changes produced by the phenomena in the target of the different UCs, which must be compatible with the duration of the project.In the frame of EQUIP-G’s terrestrial use cases (TUCs), quantum gravimetry will be applied to hydrology, volcanology, climatology, geothermic, and geodesy. In particular, among the eight TUCs that will be implemented, two deal with hydrological processes, two focus on time gravity changes developing at active volcanoes, one involves activities framed within the safety analysis of geological repositories for nuclear waste, one focuses on climate monitoring, one is devoted to demonstrating the applicability of quantum gravimetry to geothermal reservoir monitoring, one will be undertaken to assess the feasibility and advantages of using quantum devices for the execution of gravity surveys over extended areas.Furthermore, two onboard use cases (OBUCs) will be carried out. OBUC1 aims to demonstrate mobile gravity mapping onboard a fixed-wing aircraft, using a commercial quantum sensor in combination with high-quality GNSS observations. OBUC2 will be implemented using an innovative airship platform, instead of the fixed-wing aircraft. Since measurements must be averaged in time, a slow-moving platform will result in higher resolution of the spatial mapping.Here we provide a description of the EQUIP-G’s UCs, including how each of them will contribute to the assessment of the project’s goals.
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
European QUantum Infrastructure Project for Gravimetry
Imaging the Earth's interior has always been one of the key challenges in geosciences, as it is a prerequisite for understanding our planet's internal dynamics and the coupling between its inner and outer envelopes. Gravity measurements at different altitudes (ground, airborne and space-based observations) provide a unique imaging tool, as they supply direct information on mass changes at different spatio-temporal scales. Following decades of research, developments and industrial transfers, quantum technology has reached a high level of maturity and it is now possible to deliver operational quantum gravimeters offering various advantages with respect to devices that have been hitherto used.Aligned with the objective of strengthening EU’s strategic autonomy and competitiveness, the Horizon Europe project EQUIP-G [1] started in June 2025. It represents the first step towards establishing the terrestrial segment of the pan-European quantum gravimetry infrastructure, revolving around a shared Instrumental Park and a network of absolute reference stations. For this purpose, quantum gravimeters, dual quantum gravi-gradiometers and an onboard quantum gravimeter are employed. Instruments are comprehensively tested, before being deployed in the field and will demonstrate, through innovative measurement strategies, the ability of the quantum gravity network to contribute to EU priorities, such as green deal, energy management and risk mitigation. Metrological oversight ensures that all collected quantum gravity data will be SI traceable. Data are managed in line with the FAIR principles and with a long-term perspective to establish a TCS for gravimetry within EPOS. EQUIP-G engages in strong community building, aimed at involving the entire European gravimetry community in the development of the long-term Instrumental Park initiative that will extend beyond the end of the project, democratizing the use of quantum gravity devices produced in Europe. This contribution provides an overview of the structure and main objectives of EQUIP-G and presents some preliminary achievements of the project.EQUIP-G project is funded by the European Commission under the Horizon Europe program, grant number 101215427[1] https://www.equip-g.eu
- 14 March 2026
- Published by Copernicus GmbH
Open AccessEuropean QUantum Infrastructure Project for Gravimetry
Imaging the Earth's interior has always been one of the key challenges in geosciences, as it is a prerequisite for understanding our planet's internal dynamics and the coupling between its inner and outer envelopes. Gravity measurements at different altitudes (ground, airborne and space-based observations) provide a unique imaging tool, as they supply direct information on mass changes at different spatio-temporal scales. Following decades of research, developments and industrial transfers, quantum technology has reached a high level of maturity and it is now possible to deliver operational quantum gravimeters offering various advantages with respect to devices that have been hitherto used.Aligned with the objective of strengthening EU’s strategic autonomy and competitiveness, the Horizon Europe project EQUIP-G [1] started in June 2025. It represents the first step towards establishing the terrestrial segment of the pan-European quantum gravimetry infrastructure, revolving around a shared Instrumental Park and a network of absolute reference stations. For this purpose, quantum gravimeters, dual quantum gravi-gradiometers and an onboard quantum gravimeter are employed. Instruments are comprehensively tested, before being deployed in the field and will demonstrate, through innovative measurement strategies, the ability of the quantum gravity network to contribute to EU priorities, such as green deal, energy management and risk mitigation. Metrological oversight ensures that all collected quantum gravity data will be SI traceable. Data are managed in line with the FAIR principles and with a long-term perspective to establish a TCS for gravimetry within EPOS. EQUIP-G engages in strong community building, aimed at involving the entire European gravimetry community in the development of the long-term Instrumental Park initiative that will extend beyond the end of the project, democratizing the use of quantum gravity devices produced in Europe. This contribution provides an overview of the structure and main objectives of EQUIP-G and presents some preliminary achievements of the project.EQUIP-G project is funded by the European Commission under the Horizon Europe program, grant number 101215427[1] https://www.equip-g.eu
- Open Access
- 13 March 2026
- Published by Copernicus GmbH
Preliminary metrological assessment for a field differential quantum gravimeter
The FIQUgS project aims at developing advanced field quantum gravimeters with enhanced resilience to temperature variations, reduced size, and lower power consumption. Two instruments are being developed within the project: a new version of Exail's Absolute Quantum Gravimeter (AQG) and a Differential Quantum Gravimeter (DQG) [1,2]. Both instruments have benefited from design improvements that eliminate the need for a power-intensive air-conditioning unit.Here, we report on the first tests of the FIQUgS DQG conducted at LNE-OP/LTE laboratories in 2025. These tests follow similar ones carried out in 2022 with the DQG prototype [3] and include:A comparison of the absolute measurements of the DQG against AQG-B01* for gravity measurement and against a CG6* for vertical gravity gradients.A two weeks long measurement and a comparison with a superconducting gravimeter, see figure 1.An evaluation of the effect of temperature on measurement stability under varying temperature conditions.A comparison of the internal time and wavelength references against national standards.Overall, the instrument performed well within an 18-35 °C range. Preliminary results for the comparison with AQG-B01 show an agreement within 100nm/s² and gravity gradients measured using a CG6 show an agreement within 30E (1E=1nm/s²/m).Further work will aim at robustifying the system and extend the thermal operating range. Nonetheless, these results provide a solid foundation for field surveys planned with FIQUgS in mid-2026.Figure 1: 2 weeks long simultaneous gravity and vertical gravity gradient measurement of the FIQUgS DQG at LNE-OP/LTE. The FIQUgS project is funded by the European Comission under the Horizon Europe program, grant number 101080144*AQG-B01 and CG6 are instruments of INSU-CNRS French National Parc of Instruments PIN PGravi. [1] https://www.fiqugs.eu/[2] L. Antoni-Micollier et al., "Absolute Quantum Gravimeters and Gradiometers for Field Measurements," in IEEE Instrumentation & Measurement Magazine, vol. 27, no. 6, pp. 4-10, September 2024, doi: 10.1109/MIM.2024.10654720. [3] Janvier, C., Merlet, S., Rosenbusch, P., Ménoret, V., Landragin, A., Pereira dos Santos, F., and Desruelle, B.: Operational evaluation of an industrial differential quantum gravimeter, EGU General Assembly 2023, Vienna, Austria, 24–28 Apr 2023, EGU23-5171, https://doi.org/10.5194/egusphere-egu23-5171, 2023.
- 13 March 2026
- Published by Copernicus GmbH
Open AccessPreliminary metrological assessment for a field differential quantum gravimeter
The FIQUgS project aims at developing advanced field quantum gravimeters with enhanced resilience to temperature variations, reduced size, and lower power consumption. Two instruments are being developed within the project: a new version of Exail's Absolute Quantum Gravimeter (AQG) and a Differential Quantum Gravimeter (DQG) [1,2]. Both instruments have benefited from design improvements that eliminate the need for a power-intensive air-conditioning unit.Here, we report on the first tests of the FIQUgS DQG conducted at LNE-OP/LTE laboratories in 2025. These tests follow similar ones carried out in 2022 with the DQG prototype [3] and include:A comparison of the absolute measurements of the DQG against AQG-B01* for gravity measurement and against a CG6* for vertical gravity gradients.A two weeks long measurement and a comparison with a superconducting gravimeter, see figure 1.An evaluation of the effect of temperature on measurement stability under varying temperature conditions.A comparison of the internal time and wavelength references against national standards.Overall, the instrument performed well within an 18-35 °C range. Preliminary results for the comparison with AQG-B01 show an agreement within 100nm/s² and gravity gradients measured using a CG6 show an agreement within 30E (1E=1nm/s²/m).Further work will aim at robustifying the system and extend the thermal operating range. Nonetheless, these results provide a solid foundation for field surveys planned with FIQUgS in mid-2026.Figure 1: 2 weeks long simultaneous gravity and vertical gravity gradient measurement of the FIQUgS DQG at LNE-OP/LTE. The FIQUgS project is funded by the European Comission under the Horizon Europe program, grant number 101080144*AQG-B01 and CG6 are instruments of INSU-CNRS French National Parc of Instruments PIN PGravi. [1] https://www.fiqugs.eu/[2] L. Antoni-Micollier et al., "Absolute Quantum Gravimeters and Gradiometers for Field Measurements," in IEEE Instrumentation & Measurement Magazine, vol. 27, no. 6, pp. 4-10, September 2024, doi: 10.1109/MIM.2024.10654720. [3] Janvier, C., Merlet, S., Rosenbusch, P., Ménoret, V., Landragin, A., Pereira dos Santos, F., and Desruelle, B.: Operational evaluation of an industrial differential quantum gravimeter, EGU General Assembly 2023, Vienna, Austria, 24–28 Apr 2023, EGU23-5171, https://doi.org/10.5194/egusphere-egu23-5171, 2023.
- 1 December 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (6) , 065006
Calibration of two mass standards with the LNE Kibble balance in 2024
Kibble balances are complex electromechanical instruments that enable the determination of mass within the SI by linking it to the Planck constant h , the defining constant of the mass unit. The LNE has been developing its own Kibble balance since 2002, with the most recent improvements focusing on the implementation of a contactless linear motor for the dynamic phase and the fine adjustment of the beam’s orientation with respect to the horizontal plane for the static phase. In 2024, two mass calibration campaigns were carried out using the LNE Kibble balance: first with an iridium standard (DB1), and then with a platinum-iridium standard (W1). Both artefacts have a nominal mass of 500 g, and their masses were determined with relative standard uncertainties of 3.1 ⋅ 10 − 8 and 3.5 ⋅ 10 − 8 respectively ( k = 1 ).
- 1 December 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (6) , 065006
Calibration of two mass standards with the LNE Kibble balance in 2024
Kibble balances are complex electromechanical instruments that enable the determination of mass within the SI by linking it to the Planck constant h , the defining constant of the mass unit. The LNE has been developing its own Kibble balance since 2002, with the most recent improvements focusing on the implementation of a contactless linear motor for the dynamic phase and the fine adjustment of the beam’s orientation with respect to the horizontal plane for the static phase. In 2024, two mass calibration campaigns were carried out using the LNE Kibble balance: first with an iridium standard (DB1), and then with a platinum-iridium standard (W1). Both artefacts have a nominal mass of 500 g, and their masses were determined with relative standard uncertainties of 3.1 ⋅ 10 − 8 and 3.5 ⋅ 10 − 8 respectively ( k = 1 ).
- Open Access
- 18 March 2025
- Published by Copernicus GmbH
First results from the comparison of absolute gravimeters WETCAG-2024 at the Geodetic Observatory Wettzell, Germany
The validation of compatibility and long-term stability of absolute gravimeters is a key component for the realization of the International Terrestrial Gravity Reference Frame (ITGRF) of IAG and is relevant for metrology, in particular for the realization of the kilogram. Because a natural reference for the absolute value of gravity acceleration is not accessible, international comparisons of absolute gravimeters are well established. The gravity reference is realized based on a set of accurate absolute measurements and the functional model for their processing. After the CCM.G-K2.2023 key comparison supplemented by additional comparison ICAG-2023 held in September 2023 at Table Mountain Geophysical Observatory (TMGO) Boulder, Colorado, USA, there was a need to distribute the gravity reference further to institutions in Europe. Therefore, the EURAMET key comparison of absolute gravimeters EURAMET.M.G-K2.2023 and additional comparison WETCAG-2024 was organized at the Geodetic Observatory Wettzell, Germany, in May and June 2024, where 15 institutions participated with 17 absolute gravimeters. The link to CCM.G-K2.2023 is provided by three gravimeters that took part in both comparisons. Additionally, deviations from the verticality and Eötvös/Coriolis accelerations during the free fall were determined for most of the gravimeters. We present first results for the equivalence of the participating gravimeters as well as for the verticality and Eötvös effects. Further, we evaluate and discuss the stability of the reference values over decades, based on a reference function deduced from the registration of the superconducting gravimeter GWR SG030, repeated absolute gravity observations since 2010 and several regional comparisons performed at this station, in particular with the comparison EURAMET.M.G-K3 held at Wettzell in 2018. Quantum gravimeters are represented in WETCAG-2024 with two instruments. This allows to compare the new technology with the reference established at the Wettzell station over 15 years, specifically in the context of stability of gravimeters and the upcoming realization of the ITGRF.
- 18 March 2025
- Published by Copernicus GmbH
Open AccessFirst results from the comparison of absolute gravimeters WETCAG-2024 at the Geodetic Observatory Wettzell, Germany
The validation of compatibility and long-term stability of absolute gravimeters is a key component for the realization of the International Terrestrial Gravity Reference Frame (ITGRF) of IAG and is relevant for metrology, in particular for the realization of the kilogram. Because a natural reference for the absolute value of gravity acceleration is not accessible, international comparisons of absolute gravimeters are well established. The gravity reference is realized based on a set of accurate absolute measurements and the functional model for their processing. After the CCM.G-K2.2023 key comparison supplemented by additional comparison ICAG-2023 held in September 2023 at Table Mountain Geophysical Observatory (TMGO) Boulder, Colorado, USA, there was a need to distribute the gravity reference further to institutions in Europe. Therefore, the EURAMET key comparison of absolute gravimeters EURAMET.M.G-K2.2023 and additional comparison WETCAG-2024 was organized at the Geodetic Observatory Wettzell, Germany, in May and June 2024, where 15 institutions participated with 17 absolute gravimeters. The link to CCM.G-K2.2023 is provided by three gravimeters that took part in both comparisons. Additionally, deviations from the verticality and Eötvös/Coriolis accelerations during the free fall were determined for most of the gravimeters. We present first results for the equivalence of the participating gravimeters as well as for the verticality and Eötvös effects. Further, we evaluate and discuss the stability of the reference values over decades, based on a reference function deduced from the registration of the superconducting gravimeter GWR SG030, repeated absolute gravity observations since 2010 and several regional comparisons performed at this station, in particular with the comparison EURAMET.M.G-K3 held at Wettzell in 2018. Quantum gravimeters are represented in WETCAG-2024 with two instruments. This allows to compare the new technology with the reference established at the Wettzell station over 15 years, specifically in the context of stability of gravimeters and the upcoming realization of the ITGRF.
- Open Access
- 15 March 2025
- Published by Copernicus GmbH
Gravimetry platform for evaluation and characterization of quantum technologies
The Horizon Europe project “Qu-Test” [1] aims to establish a European infrastructure open to industry for the characterization and testing of components, subsystems, and instruments developed from quantum technologies. As part of this project, led by a consortium of Research Technology Institutes and National Metrology Institutes within the European Union, we are developing a platform for the functional and metrological characterization of quantum gravimeters.In my poster, I will present our reference site, which comprises our laboratory, characterized instruments, and models derived from 20 years of measurements.Our laboratory, located in the Paris region, features a 6 m × 5.5 m × 2 m concrete platform supported by 12 m long legs that reach the Fontainebleau sands layer. Initially constructed for the LNE Watt Balance [2], our activities have since expanded to include the use, study, characterization, and calibration of various types of instruments. Relative spring-based gravimeters, such as portable Scintrex CG5 and CG6 models, enable us to map and model gravity differences throughout the laboratory's 40 m³ volume. A superconducting relative gravimeter iGrav, allows continuous monitoring of temporal changes of g. The absolute reference value is provided by the atomic gravimeter CAG [3], which calibrates the iGrav’s scale factor [4] and evaluates its drift.The laboratory's size facilitates the simultaneous accommodation of several gravimeters, enabling regular comparison campaigns. The first comparison in 2006 involved only absolute gravimeters of the FG5 type, while recent comparisons have also included atomic gravimeters like AQGs [5]. The site is routinely used to assess the performance and verify the functionality of the French national gravimeter park (PIN PGravi) [6], particularly before participating in international comparisons with FG5 (#206 and #228) [7] and AQG-B01 [8].This open-access reference site allows users to verify their instruments before field missions, calibrate spring-based relative gravimeters such as the gPhoneX, and test new developments, including quantum gravimeter and dual gravi-gradio-meter systems.[1] https://qu-test.eu[2] M. Thomas et al (2017) metrologia 54[3] R. Karcher et al (2018) New J. Phys 20[4] S. Merlet et al (2021) J Geod 95[5] V. Ménoret et al (2018) Sci Rep 8[6] S. Merlet et al (2024) IEEE Instrum Meas Mag 27[7] H. Wziontek et al (2025) G4.2 EGU[8] S. Merlet et al (2025) G4.2 EGU
- 15 March 2025
- Published by Copernicus GmbH
Open AccessGravimetry platform for evaluation and characterization of quantum technologies
The Horizon Europe project “Qu-Test” [1] aims to establish a European infrastructure open to industry for the characterization and testing of components, subsystems, and instruments developed from quantum technologies. As part of this project, led by a consortium of Research Technology Institutes and National Metrology Institutes within the European Union, we are developing a platform for the functional and metrological characterization of quantum gravimeters.In my poster, I will present our reference site, which comprises our laboratory, characterized instruments, and models derived from 20 years of measurements.Our laboratory, located in the Paris region, features a 6 m × 5.5 m × 2 m concrete platform supported by 12 m long legs that reach the Fontainebleau sands layer. Initially constructed for the LNE Watt Balance [2], our activities have since expanded to include the use, study, characterization, and calibration of various types of instruments. Relative spring-based gravimeters, such as portable Scintrex CG5 and CG6 models, enable us to map and model gravity differences throughout the laboratory's 40 m³ volume. A superconducting relative gravimeter iGrav, allows continuous monitoring of temporal changes of g. The absolute reference value is provided by the atomic gravimeter CAG [3], which calibrates the iGrav’s scale factor [4] and evaluates its drift.The laboratory's size facilitates the simultaneous accommodation of several gravimeters, enabling regular comparison campaigns. The first comparison in 2006 involved only absolute gravimeters of the FG5 type, while recent comparisons have also included atomic gravimeters like AQGs [5]. The site is routinely used to assess the performance and verify the functionality of the French national gravimeter park (PIN PGravi) [6], particularly before participating in international comparisons with FG5 (#206 and #228) [7] and AQG-B01 [8].This open-access reference site allows users to verify their instruments before field missions, calibrate spring-based relative gravimeters such as the gPhoneX, and test new developments, including quantum gravimeter and dual gravi-gradio-meter systems.[1] https://qu-test.eu[2] M. Thomas et al (2017) metrologia 54[3] R. Karcher et al (2018) New J. Phys 20[4] S. Merlet et al (2021) J Geod 95[5] V. Ménoret et al (2018) Sci Rep 8[6] S. Merlet et al (2024) IEEE Instrum Meas Mag 27[7] H. Wziontek et al (2025) G4.2 EGU[8] S. Merlet et al (2025) G4.2 EGU