Qiong Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qiong Jiang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Min Sun
Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
4 shared publications - Juanjuan Feng
Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
3 shared publications - Peng Xu
College of Plant Protection, Gansu Agricultural University/Biocontrol Engineering Laboratory of Crop Diseases and Pests of Gansu Province, Lanzhou 730070, China
2 shared publications Hongdeng Qiu
Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics , Chinese Academy of Sciences , Lanzhou, P. R. China
1 shared publicationPeng Xu
College of Plant Protection Gansu Agricultural University/Biocontrol Engineering Laboratory of Crop Diseases and Pests of Gansu Province Lanzhou Gansu P. R. China
1 shared publicationShusheng Zhang
Key Laboratory of Chemical Biology and Organic Chemistry of Henan, Chemistry Department , Zhengzhou University , Zhengzhou, P. R. China
1 shared publication
Latest Publications
- Open Access
- 22 May 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (10) , 1766
Silica Aerogel Hybridized with Melamine-Terephthalaldehyde Polymer for In-Tube Solid-Phase Microextraction of Polycyclic Aromatic Hydrocarbons from Environment Water
To improve the extraction performance of the silica aerogel, a melamine-terephthalaldehyde polymer was used to hybridize silica aerogel, and the hybridized aerogel was coated on the surface of stainless steel wire to prepare a fiber-filled extraction tube through placing four wires into a polyetheretherketone tube. The tube was combined with high-performance liquid chromatography, then the online extraction and detection were established. Several polycyclic aromatic hydrocarbons (PAHs) were selected as the target analytes. Under the optimum extraction and desorption conditions, the limit of detection was as low as 3.0 ng L−1, and the linear range was 0.01–20.0 μg L−1. The enrichment factors of PAHs were in the range of 1724–2393. Three environmental water samples of mineral water, tap water and river water were analyzed by this method, and the recoveries that spiked at 1.0–10.0 μg L−1 were between 80.5–126%. It showed many advantages compared with other methods, such as better sensitivity, faster detection and online analysis.
- 22 May 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (10) , 1766
Open AccessSilica Aerogel Hybridized with Melamine-Terephthalaldehyde Polymer for In-Tube Solid-Phase Microextraction of Polycyclic Aromatic Hydrocarbons from Environment Water
To improve the extraction performance of the silica aerogel, a melamine-terephthalaldehyde polymer was used to hybridize silica aerogel, and the hybridized aerogel was coated on the surface of stainless steel wire to prepare a fiber-filled extraction tube through placing four wires into a polyetheretherketone tube. The tube was combined with high-performance liquid chromatography, then the online extraction and detection were established. Several polycyclic aromatic hydrocarbons (PAHs) were selected as the target analytes. Under the optimum extraction and desorption conditions, the limit of detection was as low as 3.0 ng L−1, and the linear range was 0.01–20.0 μg L−1. The enrichment factors of PAHs were in the range of 1724–2393. Three environmental water samples of mineral water, tap water and river water were analyzed by this method, and the recoveries that spiked at 1.0–10.0 μg L−1 were between 80.5–126%. It showed many advantages compared with other methods, such as better sensitivity, faster detection and online analysis.
- Open Access
Application of Covalent Organic Porous Polymers-Functionalized Basalt Fibers for in-Tube Solid-Phase Microextraction
To establish an online analytical method towards estrogenic pollutants, a covalent organic porous polymer (COP) was in-situ synthesized on the surface of basalt fibers (BFs) for in-tube solid-phase microextraction (IT-SPME). The extraction tube, obtained via placing the modified BFs into a polyetheretherketone tube, was combined with high-performance liquid chromatography (HPLC) to achieve online IT-SPME-HPLC analysis. The important parameters, including sampling volume, sampling rate, organic solvent content and desorption time, were carefully investigated. Under the optimized conditions, the online analytical method was established for five estrogenic targets, with low limits of detection (0.001–0.005 μg/L), high enrichment factors (1800–2493), wide linear ranges (0.003–20, 0.015–20 μg/L) and satisfactory repeatability. It was successfully applied to detect five estrogens in a wastewater sample and a water sample in a polycarbonate cup. The BFs functionalized with COPs displayed excellent extraction effect for estrogenic pollutants, furthermore it has great potential in sample preparation or other fields.
Open AccessApplication of Covalent Organic Porous Polymers-Functionalized Basalt Fibers for in-Tube Solid-Phase Microextraction
To establish an online analytical method towards estrogenic pollutants, a covalent organic porous polymer (COP) was in-situ synthesized on the surface of basalt fibers (BFs) for in-tube solid-phase microextraction (IT-SPME). The extraction tube, obtained via placing the modified BFs into a polyetheretherketone tube, was combined with high-performance liquid chromatography (HPLC) to achieve online IT-SPME-HPLC analysis. The important parameters, including sampling volume, sampling rate, organic solvent content and desorption time, were carefully investigated. Under the optimized conditions, the online analytical method was established for five estrogenic targets, with low limits of detection (0.001–0.005 μg/L), high enrichment factors (1800–2493), wide linear ranges (0.003–20, 0.015–20 μg/L) and satisfactory repeatability. It was successfully applied to detect five estrogens in a wastewater sample and a water sample in a polycarbonate cup. The BFs functionalized with COPs displayed excellent extraction effect for estrogenic pollutants, furthermore it has great potential in sample preparation or other fields.
- 15 January 2020
- Published by Wiley in Journal of Separation Science
- Vol. 43 (7) , 1323-1330
Resorcinol–formaldehyde aerogel coating for in‐tube solid‐phase microextraction of estrogens
Resorcinol–formaldehyde aerogel coating was in situ prepared on the surface of basalt fibers. The aerogel coating is uniformly modified onto basalt fibers, and it is very porous according to the characterization by using scanning electron microscopy. An extraction tube was prepared for in‐tube solid‐phase microextraction by placing the aerogel‐coated basalt fibers into a polyetheretherketone tube. To evaluate the extraction performance toward five estrogenic compounds, the tube was connected with high performance liquid chromatography, the important extraction and desorption conditions were investigated. An online analytical method for detection of estrogens was developed and presented low limits of detection (0.005–0.030 µg/L), wide linear ranges (0.017–20, 0.033–20, and 0.099–20 µg/L), good linearity (r > 0.9990), and satisfactory repeatability (relative standard deviation < 2.7%). The method was successfully applied to detect trace estrogens in real water samples (bottled pure water and bottled mineral water), satisfactory recoveries were ranged from 80 to 125% with two spiking levels of 2 and 6 µg/L.
- 15 January 2020
- Published by Wiley in Journal of Separation Science
- Vol. 43 (7) , 1323-1330
Resorcinol–formaldehyde aerogel coating for in‐tube solid‐phase microextraction of estrogens
Resorcinol–formaldehyde aerogel coating was in situ prepared on the surface of basalt fibers. The aerogel coating is uniformly modified onto basalt fibers, and it is very porous according to the characterization by using scanning electron microscopy. An extraction tube was prepared for in‐tube solid‐phase microextraction by placing the aerogel‐coated basalt fibers into a polyetheretherketone tube. To evaluate the extraction performance toward five estrogenic compounds, the tube was connected with high performance liquid chromatography, the important extraction and desorption conditions were investigated. An online analytical method for detection of estrogens was developed and presented low limits of detection (0.005–0.030 µg/L), wide linear ranges (0.017–20, 0.033–20, and 0.099–20 µg/L), good linearity (r > 0.9990), and satisfactory repeatability (relative standard deviation < 2.7%). The method was successfully applied to detect trace estrogens in real water samples (bottled pure water and bottled mineral water), satisfactory recoveries were ranged from 80 to 125% with two spiking levels of 2 and 6 µg/L.
- Open Access
Nanostructured Silver Coating as a Stationary Phase for Capillary Gas Chromatography
A capillary column coated with nanostructured silver coating was fabricated for gas chromatography. The nanostructured silver coating, about 80–120 nm in thickness, was prepared as the stationary phase via silver mirror reaction, and was characterized by SEM and EDS. The column was evaluated using different types of model analytes, including n-alkanes, n-alcohols, benzenes, and Grob mixture. A baseline separation of ten n-alkanes on the silver column (15 m × 0.20 mm i.d.) was achieved within 3.5 min through the main hydrophobic mechanism. A mixture of six n-alcohols, or another mixture containing three butanol isomers and two octanol isomers, was separated well on the column. The column separated some benzenes containing benzene, toluene, ethylbenzene, p-xylene, o-xylene, styrene, benzaldehyde, and benzyl alcohol. A Grob mixture containing seven analytes was also separated successfully. Based on a multiple retention mechanism such as hydrophobic, dipole-dipole, and dipole-induced dipole interactions, the silver column achieved a good separation of twelve different types of compounds within 2.5 min. The column presented satisfactory separation repeatability with relative standard deviation of retention time between 0.073% and 0.591%. The results indicate that the silver column is promising for gas chromatographic separation.
Open AccessNanostructured Silver Coating as a Stationary Phase for Capillary Gas Chromatography
A capillary column coated with nanostructured silver coating was fabricated for gas chromatography. The nanostructured silver coating, about 80–120 nm in thickness, was prepared as the stationary phase via silver mirror reaction, and was characterized by SEM and EDS. The column was evaluated using different types of model analytes, including n-alkanes, n-alcohols, benzenes, and Grob mixture. A baseline separation of ten n-alkanes on the silver column (15 m × 0.20 mm i.d.) was achieved within 3.5 min through the main hydrophobic mechanism. A mixture of six n-alcohols, or another mixture containing three butanol isomers and two octanol isomers, was separated well on the column. The column separated some benzenes containing benzene, toluene, ethylbenzene, p-xylene, o-xylene, styrene, benzaldehyde, and benzyl alcohol. A Grob mixture containing seven analytes was also separated successfully. Based on a multiple retention mechanism such as hydrophobic, dipole-dipole, and dipole-induced dipole interactions, the silver column achieved a good separation of twelve different types of compounds within 2.5 min. The column presented satisfactory separation repeatability with relative standard deviation of retention time between 0.073% and 0.591%. The results indicate that the silver column is promising for gas chromatographic separation.
- 23 April 2008
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 31 (10) , 1448-1457
Effect of Ionic Liquids as Additives on the Separation of Bases and Amino Acids in HPLC
In this paper, four bases, including cytosine, thymine, adenine, 6‐chlorouracil and four amino acids, including L‐histidine, L‐tyrosine, L‐phenylalanine, and DL‐tryptophane, were separated with different types of ionic liquids as additives for the mobile phase in high‐performance liquid chromatography. Four different ILs, including 1‐ethyl‐3‐methylimidazolium tetrafluoroborate, 1‐butyl‐3‐methylimidazolium tetrafluoroborate, 1‐hexyl‐3‐methylimidazolium tetrafluoroborate, and 1‐butyl‐3‐methylimidazolium chloride were used. The effects of the length of the alkyl group on the imidazolium ring and its counterion, the concentrations of the ionic liquids on the retention factor of the bases and amino acids are investigated. The results showed that the retention and resolution of the bases and amino acids were improved when ionic liquids were used as additives. The mechanism at the separation with ionic liquids as additive to mobile phase is discussed.
- 23 April 2008
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 31 (10) , 1448-1457
Effect of Ionic Liquids as Additives on the Separation of Bases and Amino Acids in HPLC
In this paper, four bases, including cytosine, thymine, adenine, 6‐chlorouracil and four amino acids, including L‐histidine, L‐tyrosine, L‐phenylalanine, and DL‐tryptophane, were separated with different types of ionic liquids as additives for the mobile phase in high‐performance liquid chromatography. Four different ILs, including 1‐ethyl‐3‐methylimidazolium tetrafluoroborate, 1‐butyl‐3‐methylimidazolium tetrafluoroborate, 1‐hexyl‐3‐methylimidazolium tetrafluoroborate, and 1‐butyl‐3‐methylimidazolium chloride were used. The effects of the length of the alkyl group on the imidazolium ring and its counterion, the concentrations of the ionic liquids on the retention factor of the bases and amino acids are investigated. The results showed that the retention and resolution of the bases and amino acids were improved when ionic liquids were used as additives. The mechanism at the separation with ionic liquids as additive to mobile phase is discussed.