CBCheryle N. Beuning

Cheryle N. Beuning

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Cheryle N. Beuning has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Vapor pressure measurements on Δ 9 -tetrahydrocannabinol, cannabidiol, and cannabinol to inform cannabis breathalyzer development

    by Cheryle Beuning, Jennifer Berry, Eugene Paulechka, Marcia Huber, Kavita M. Jeerage, Jason Widegren, Tara Lovestead

    Δ 9 -tetrahydrocannabinol (THC), the main psychoactive compound in cannabis, and other drug molecules that have large molar masses, are often described as “nonvolatile” and are presumed to be carried in exhaled breath aerosols. Large variabilities in THC concentrations in breath have been measured with devices that only collect aerosols; it is possible that neglecting the vapor phase could be responsible. Partitioning of compounds between vapor and aerosol phases is directly dependent on vapor pressure ( p sat ), which itself is strongly dependent on temperature. We describe p sat measurements for THC, cannabidiol (CBD), and cannabinol (CBN) using a gas-saturation apparatus. The measured values of p sat for 364 K to 424 K are 0.0459 Pa to 7.833 Pa for THC, 0.0826 Pa to 13.44 Pa for CBD, and 0.0199 Pa to 5.678 Pa for CBN. The combined standard ( k = 1, 68 % confidence) measurement uncertainty in p sat ranges from 2.9 % to 5.3 % for CBD and CBN, and from 5.2 % to 9.5 % for THC. To obtain the p sat at human body and exhaled breath temperatures, we extrapolated the measurements for each cannabinoid with a thermodynamic correlation. Then a vapor-aerosol partitioning model was used to predict mole fractions of each cannabinoid in each phase of exhaled breath. All three cannabinoids were predicted to reside primarily in the vapor phase of exhaled breath. However, relatively small changes in temperature or aerosol concentration can significantly impact the predicted partitioning. This work illustrates the utility of low-uncertainty p sat measurements for any drug, including those thought to be too low in volatility for vapor-phase sampling, and may extend the market for forensic drug tests and clinical diagnostic tests via breath analysis.


  • Open Access

    Cannabinoids detected in exhaled breath condensate after cannabis use

    by Jennifer L Berry, Ashley Brooks-Russell, Cheryle N Beuning, Sarah A Limbacher, Tara M Lovestead, Kavita M Jeerage

    Cannabinoids can be detected in breath after cannabis use, but different breath matrices need to be explored as studies to date with filter-based devices that collect breath aerosols have not demonstrated that breath-based measurements can reliably identify recent cannabis use. Exhaled breath condensate (EBC) is an unexplored aqueous breath matrix that contains condensed volatile compounds and water vapor in addition to aerosols. EBC was collected from participants both before and at two time points (0.7 ± 0.2 h and 1.7 ± 0.3 h) after observed cannabis use. Eleven different cannabinoids were monitored with liquid chromatography tandem mass spectrometry. Five different cannabinoids, including Δ9-tetrahydrocannabinol (THC), were detected in EBC collected from cannabis users. THC was detected in some EBC samples before cannabis use, despite the requested abstinence period. THC was detected in all EBC samples collected at 0.7 h post use and decreased for all participants at 1.7 h. Non-THC cannabinoids were only detected after cannabis use. THC concentrations in EBC samples collected at 0.7 h showed no trend with sample metrics like mass or number of breaths. EBC sampling devices deserve further investigation with respect to modes of cannabis use (e.g, edibles), post use time points, and optimization of cannabinoid recovery.


  • Vapor Pressure Measurements on Linalool Using a Rapid and Inexpensive Method Suitable for Cannabis-Associated Terpenes

    by Cheryle N. Beuning, Tara M. Lovestead, Marcia L. Huber, Jason A. Widegren

    Vapor pressure (psat) data are needed to assess the potential use of terpenes as breath markers of recent cannabis use. Herein, a recently introduced gas-saturation method for psat measurements, known as dynamic vapor microextraction (DVME), was used to measure psat for the terpene (±)-3,7-dimethylocta-1,6-dien-3-ol, commonly known as linalool. The DVME apparatus utilizes inexpensive and commercially available components, a low internal volume, and helium carrier gas to minimize nonideal mixture behavior. In the temperature range from 314 K to 354 K, DVME-based measurements of the psat of linalool ranged from 81 Pa to 1250 Pa. With a measurement period of 30 min, the combined standard uncertainty of these measurements ranged from 0.0358·psat to 0.0584·psat, depending on temperature. The DVME-based measurements agree with a Wagner correlation of available literature data. We demonstrate that DVME produces accurate results for values of psat that are 200 times higher than in the DVME validation study with n-eicosane (C20H42). The oxidative stability of linalool was improved by the addition of 0.2 mass % of the antioxidant tert-butylhydroquinone.


  • Open Access

    THC in breath aerosols collected with an impaction filter device before and after legal-market product inhalation—a pilot study

    by Kavita M Jeerage, Cheryle N Beuning, Adam J Friss, L Cinnamon Bidwell, Tara M Lovestead

    An accurate cannabis breathalyzer based on quantitation of the psychoactive cannabinoid Δ9-tetrahydrocannabinol (THC) could be an important tool for deterring impaired driving. Such a device does not exist. Simply translating what is known about alcohol breathalyzers is insufficient because ethanol is detected as a vapor. THC has extremely low volatility and is hypothesized to be carried in breath by aerosol particles formed from lung surfactant. Exhaled breath aerosols can be recovered from electrostatic filter devices, but consistent quantitative results across multiple studies have not been demonstrated. We used a simple-to-use impaction filter device to collect breath aerosols from participants before and after they smoked a legal market cannabis flower containing ∼25% Δ9-tetrahydrocannabinolic acid. Breath collection occurred at an intake session (baseline-intake) and four weeks later in a federally-compliant mobile laboratory 15 min before (baseline-experimental) and 1 h after cannabis use (post-use). Cannabis use was in the participant’s residence. Participants were asked to follow a breathing maneuver designed to increase aerosol production. Breath extracts were analyzed by liquid chromatography with tandem mass spectrometry with multiple reaction monitoring of two transitions for analytes and their deuterated internal standards. Over more than 1 yr, 42 breath samples from 18 participants were collected and analyzed in six batches. THC was quantified in 31% of baseline-intake, 36% of baseline-experimental, and 80% of 1 h post-use breath extracts. The quantities observed 1 h post-use are compared to those reported in six other pilot studies that sampled breath at known intervals following cannabis use and are discussed with respect to participant characteristics and breath sampling protocols. Larger studies with verified abstinence and more post-use timepoints are necessary to generate statistically significant data to develop meaningful cannabis breathalyzer technology.


  • Open Access

    Vapor Pressure Measurements on Linalool Using a Rapid and Inexpensive Method Suitable for Cannabis-Associated Terpenes†

    by Jason Aaron Widegren, Cheryle N. Beuning, Tara M. Lovestead, Marcia L. Huber

    Vapor pressure (psat) data are needed to assess the potential use of terpenes as breath markers of recent cannabis use. One reason such data are often lacking is that there are no commercially available devices that can measure the relatively low psat for these compounds near body temperature. Herein, a new type of gas-saturation method for psat measurements, known as dynamic vapor microextraction (DVME), was used to measure psat for the terpene (±)-3,7-dimethylocta-1,6-dien-3-ol, commonly known as linalool. The DVME apparatus was assembled from inexpensive, commercially available components. The small internal volume of the DVME apparatus allows for rapid measurements with a small volume of helium carrier gas. DVME utilizes helium as the carrier gas to minimize nonideal mixture behavior. In the temperature range from 314 K to 354 K, DVME-based measurements of the psat of linalool ranged from 81 Pa to 1250 Pa. With a measurement period of 30 min, the combined standard uncertainty of these measurements ranged from 3.6% – 6.1%, depending on temperature. The DVME-based measurements agreed with a Wagner correlation of available literature data. We demonstrated that DVME produces accurate results to pressures at least 200 times higher than in the previous study with n-eicosane (C20H42) and that sample stability can be controlled with the addition of the antioxidant tert-butylhydroquinone. This greatly expands the number of compounds that can be measured by DVME, including many compounds that could serve as markers of recent cannabis use.

  • Open Access

    Plasma Amino Acid Response to Whey Protein Ingestion Following 28 Days of Probiotic (Bacillus subtilis DE111) Supplementation in Active Men and Women

    by Jeremy R. Townsend, William C. Vantrease, Megan D. Jones, Philip A. Sapp, Kent D. Johnson, Cheryle N. Beuning, Allison A. Haase, Claudia M. Boot

    We sought to determine if 28 days of probiotic supplementation influenced the plasma amino acid (AA) response to acute whey protein feeding. METHODS: Twenty-two recreationally active men (n = 11; 24.3 ± 3.2 yrs; 89.3 ± 7.2 kg) and women (n = 11; 23.0 ± 2.8 yrs; 70.2 ± 15.2 kg) participated in this double-blind, placebo-controlled, randomized study. Before (PRE) and after 28 days of supplementation (POST), participants reported to the lab following a 10-hr fast and provided a resting blood draw (0 min), then subsequently consumed 25 g of whey protein. Blood samples were collected at 15-min intervals for 2 h post-consumption (15–120 min) and later analyzed for plasma leucine, branched-chain AA (BCAA), essential AA (EAA), and total AA (TAA). Participants received a probiotic (PROB) consisting of 1 x10-9 colony forming units (CFU) Bacillus subtilis DE111 (n = 11) or a maltodextrin placebo (PL) (n = 11) for 28 days. Plasma AA response and area under the curve (AUC) values were analyzed via repeated measures analysis of variance. RESULTS: Our analysis indicated no significant (p < 0.05) differential responses for plasma leucine, BCAA, EAA, or TAA between PROB and PL from PRE to POST. AUC analysis revealed no group × time interaction for plasma leucine (p = 0.524), BCAA (p = 0.345), EAA (p = 0.512), and TAA (p = 0.712). CONCLUSION: These data indicate that 28 days of Bacillus subtilis DE111 does not affect plasma AA appearance following acute whey protein ingestion.


  • Open Access

    The Effect of ProHydrolase® on the Amino Acid and Intramuscular Anabolic Signaling Response to Resistance Exercise in Trained Males

    by Jeremy R. Townsend, Jaclyn E. Morimune, Megan D. Jones, Cheryle N. Beuning, Allison A. Haase, Claudia M. Boot, Stephen H. Heffington, Laurel A. Littlefield, Ruth N. Henry, Autumn C. Marshall, et al.

    This double-blind study examined effects of a protease enzyme blend (Prohydrolase®) added to whey protein on post-resistance exercise aminoacidemia and intramuscular anabolic signaling were investigated in ten resistance-trained males. Participants completed 4 sets of 8–10 repetitions in the leg press and leg extension exercises at 75% of 1-repetition maximum. Participants then consumed either 250 mg of Prohydrolase® + 26 g of whey protein (PW), 26 g whey alone (W), or non-nutritive control (CON) in counterbalanced order. Blood samples were obtained prior to exercise (baseline) and then immediately-post (IP), 30-, 60-, 90-, 120-, and 180-min post-exercise. Muscle biopsies were taken at baseline, 1-h (1H), and 3-h (3H) post-exercise. Phosphorylation of AKTSer437 was decreased (3H only: p < 0.001), mTORSer2448 was increased (1H: p = 0.025; 3H: p = 0.009), and p70S6KThr412 remained unchanged similarly for each condition. Plasma leucine, branch-chained amino acids, and essential amino acid concentrations for PW were significantly higher than CON (p < 0.05) at 30 min and similar to W. Compared to IP, PW was the only treatment with elevated plasma leucine levels at 30 min (p = 0.007; ∆ = 57.8 mmol/L, 95% Confidence Interval (CI): 20.0, 95.6) and EAA levels at 180 min (p = 0.003; ∆ = 179.1 mmol/L, 95% CI: 77.5, 280.7). Area under the curve amino acid analysis revealed no differences between PW and W. While no different than W, these data indicate that PW was the only group to produce elevated amino acid concentrations 30-min and 180-min post-ingestion.


  • Coordination Chemistry of a Controlled Burst of Zn2+ in Bulk Aqueous and Nanosized Water Droplets with a Zincon Chelator

    by Cheryle N. Beuning, Noah E. Barkley, Prem N. Basa, Shawn C. Burdette, Nancy E. Levinger, Debbie C. Crans

    The light-induced photolysis of [Zn(NTAdeCage)]− generates a temporally controlled burst of Zn2+, which is rapidly chelated in situ by the free ligand Zincon2–. The [Zn(Zincon)]2– coordination progress is monitored using absorption spectroscopy in bulk aqueous buffer and reverse micelle environments. The [Zn(NTAdeCage)]− photocage and free ligand Zincon2– have different reverse micelle locations that affect the [Zn(Zincon)]2– formation at the nanoscale compared to the bulk aqueous buffer. The formation of [Zn(Zincon)]2– in a bulk aqueous buffer is more efficient despite the released Zn2+ and Zincon2– being physically closer within reverse micelles. The observed reduction of complex formation is attributed to the interfacial partitioning of Zincon2–, distinct from the Zn2+ photocage in the water pool, requiring diffusion for the species to meet to form [Zn(Zincon)]2–. This work introduces a proof-of-concept methodology to experimentally measure fast chelation reactions in confined spaces and thus provides an approach to exploring cellular responses.