XQXiushu Qu

Xiushu Qu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiushu Qu has a total of 20 co-authors. Here are the top co-authors by number of shared publications:

  • Guojun Sun

    Faculty of Architecture, Civil and Transportation Engineering, Beijing University of Technology, Beijing 100124, China

    2 shared publications
  • Qi Liu

    School of Civil and Transportation Engineering, Beijing University of Civil Engineering and Architecture, Beijing, China

    2 shared publications
  • Yuxiang Deng

    School of Civil and Transportation Engineering, Beijing University of Civil Engineering and Architecture, Beijing, China

    2 shared publications
  • Bin Liu

    Beijing University of Civil Engineering and Architecture, School of Civil and Transportation Engineering, Beijing, China

    1 shared publication
  • Chenghao Qin

    China Huanqiu Contracting & Engineering (Beijing) Company Limited, Beijing, China

    1 shared publication
  • Chenghao Qin

    School of Civil and Transportation Engineering, Beijing University of Civil Engineering and Architecture, Beijing 100044,China

    1 shared publication

Latest Publications

  • Open Access

    Research on the Mechanical Behavior of External Composite Steel Bar Under Cyclic Tension-Compression Loading

    by Xiushu Qu, Jialong Yang, Hongmeng Liu, Kexin Sun

    A self-centering prefabricated concrete frame structure has good seismic performance, and its seismic capacity is mainly provided by the recovery force of the unbonded prestressing tendons and the energy-dissipation deformation capacity of embedded steel reinforcement. Relocating embedded reinforcement to external positions enables replaceability of energy dissipation components. And the configuration of external energy dissipation components is the primary factor influencing their energy dissipation capacity. Based on the existing external “Plug & Play” configuration, the internal steel bar size and material properties such as those of steel bar and filling material were varied in this study, and then, cyclic tension-compression experimental studies and numerical simulations were conducted to investigate the energy dissipation performance index and key influencing factors of this type of external composite steel bar. The research results showed that the composite steel bars designed in the experiments exhibited superior overall energy dissipation performance. Specimens utilizing Q345B steel as the core material outperformed those with Grade 30 steel. Moreover, the slenderness ratio of the composite steel bars and the diameter ratio between the end region and weakened segment of the internal steel bars were identified as critical parameters governing energy dissipation performance, and recommendations for optimal parameter ranges were discussed. This study provides a theoretical foundation for implementing external composite steel bars in self-centering structural systems.

  • Seismic behavior of precast prestressed concrete frame joints with different energy dissipation designs

    by XiuShu Qu, Chenghao Qin, GuoJun Sun, Yuxiang Deng, Xiao Fu

    The unbonded post-tensioned precast concrete joint based on PRESSS (Precast Seismic Structural System) technology has a simple form, convenient construction, and strong deformation-recovery properties. In this paper, both experimental and theoretical analysis methods were used to study the influence of different energy dissipation components on the seismic performance of the unbonded post-tensioned precast concrete joint. First, based on the existing ‘plug-and-play’ energy dissipation device, this paper improved its construction and designed two types of joints with new external energy dissipaters and internal energy-dissipating bars, respectively. Subsequently, low-reversed cyclic loading experiments were conducted. The two joints’ seismic performance indexes, failure mode, hysteresis curve, skeleton curve, ductility coefficient, and residual deformation were compared and analyzed. The experimental results showed that internal energy-dissipating bars exhibited greater energy dissipation. In contrast, the joint with the new external energy dissipater had higher initial stiffness than the joint with internal energy-dissipating bars. In addition, the force transmission mechanism and the calculation formula of the initial rotational stiffness of the joints were deduced through theoretical analysis, and the theoretical derivation was further verified by combining the experimental values. Overall, both joints conformed to the definition of semi-rigid connections in EC3, and the joint design conformed to the “strong column and weak beam, strong joint and weak member” principle. Finally, a new anchoring system for the energy dissipaters is proposed to ensure the effective connection between the energy dissipater and the bearing.

  • Study of mechanical properties of grouting defective sleeve

    by Xiushu Qu, Yannan Xie, Yanbo Sun, Guojun Sun, YuXiang Deng, Chenghao Qin


  • Eccentric compression behaviour of rectangular concrete-filled steel tube columns with self-compacting lower expansion concrete

    by XiuShu Qu, Yuxiang Deng, GuoJun Sun, Qingwen Liu, Qi Liu

    The use of a self-compacting lower expansion concrete in a concrete-filled steel tube (CFST) structure not only promotes the quality of concrete pouring but also improves the bond behaviour between the steel and the concrete. In combination with the actual stress state of the columns in the engineering structure, it is necessary to study the eccentric compression behaviour of the column. In this study, experimental studies involving both uniaxial and biaxial bending tests of rectangular self-compacting lower expansion CFST columns were carried out. The variation laws of the load–displacement curves, the lateral deflection curves and the stress–strain curves during the loading phase were analysed. Furthermore, the failure modes and the mechanical properties of the specimens under eccentric compression loads were investigated. Subsequently, the numerical models of CFST columns with self-compacting lower expansion concrete were considered and established. In order to verify the rationality of the finite element modelling, the numerical calculation results were compared with test results. Then, a parametric analysis of the compression and the bending bearing capacities of each column was carried out by changing the eccentricity of the load, and the N–M curves or N-M x -M y surfaces describing the ultimate bearing capacity of the column were obtained. Finally, by the parametric finite element analysis of the rectangular CFST columns regarding to the bearing capacity under the same eccentricity, a conclusion was obtained: when the expansion agent content γ of a specimen increased from 0% to 10%, the bearing capacity of the columns increases significantly, but when continue increasing the expansive agent content, the expansion agent content has little effect on the compression–bending bearing capacity.


  • Axial compressive behaviour of concrete-filled steel tubular columns with interfacial damage

    by Xiushu Qu, Fei Huang, Guojun Sun, Qi Liu, Hui Wang

    In a previous study, 17 rectangular concrete-filled steel tubular columns were tested using a push-out test method to examine the interfacial bond behaviour. In this study, these specimens were subjected to axial compressive tests to study the effects of interfacial damage on the ultimate axial compressive capacity. The variations in both the load–axial displacement curves and load–strain curves were recorded and then compared to study the influences of both the steel tube fabrication method and the D/B ratio on the axial load–carrying capacity. The axial compressive behaviour of rectangular concrete-filled steel tubular columns with no interfacial damage was then studied using a numerical analysis method. The contact stress distribution along the length and width of the face and at the height of the interface was obtained and discussed. In addition, the ultimate axial compressive capacity of rectangular concrete-filled steel tubular columns with no interfacial damage was calculated using the formulas from three international codes. The influence of interfacial damage on the axial compressive bearing capacity of a rectangular concrete-filled steel tubular column was discussed through a comparison of the results of the numerical simulation, formula calculation and experiments. The influence of the interfacial gaps caused by the push-out tests on the axial bearing capacity of the concrete-filled steel tubular columns can be ignored, because the core concrete was not destroyed and the outside steel tube can provide a sufficient constraint force on the concrete when the two materials yielded. Finally, the influences of the gap type and size on the bearing capacity were discussed.