Alexander Rischka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Alexander Rischka has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
- Christoph Schweiger
Max-Planck-Institut für Kernphysik
5 shared publications - Klaus Blaum
Max-Planck-Institut für Kernphysik, Heidelberg, Germany
5 shared publications - Rima X. Schüssler
University of Amsterdam
5 shared publications - Kathrin Kromer
Max-Planck-Institut für Kernphysik, Heidelberg, Germany
4 shared publications - Menno Door
Max-Planck-Institut für Kernphysik
4 shared publications C. M. König
Max Planck Institute for Nuclear Physics, Heidelberg, Germany
3 shared publications
Latest Publications
- Open Access
- 25 March 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (12) , 121801
Improved Limit on the Effective Electron Neutrino Mass with the ECHo-1k Experiment
The effective electron neutrino mass can be determined by analyzing the end-point region of the Ho 163 electron capture spectrum, provided a measurement with high-energy resolution and high statistics using calorimetric techniques. Here, the Electron Capture in Ho 163 Collaboration (ECHo) presents an analysis of the most precise Ho 163 spectrum currently available, obtained with the ECHo-1k experiment and comprising about 200 million events. A very low background rate of b const = 9.1 ( 1.3 ) × 10 − 6 eV/pixel/day was achieved allowing for a reliable analysis of the end-point region. The derived end-point energy Q = 2862 ( 4 ) eV is in excellent agreement with the one independently determined via Penning-trap mass spectrometry of Q = 2863.2 ( 6 ) eV [Ch. Schweiger , ]. The upper limit of the effective electron neutrino mass is improved by almost a factor of 2 compared to the lowest current value [B. K. Alpert , ], reaching m ν e < 15 eV / c 2 (90% credible interval).
- 25 March 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (12) , 121801
Open AccessImproved Limit on the Effective Electron Neutrino Mass with the ECHo-1k Experiment
The effective electron neutrino mass can be determined by analyzing the end-point region of the Ho 163 electron capture spectrum, provided a measurement with high-energy resolution and high statistics using calorimetric techniques. Here, the Electron Capture in Ho 163 Collaboration (ECHo) presents an analysis of the most precise Ho 163 spectrum currently available, obtained with the ECHo-1k experiment and comprising about 200 million events. A very low background rate of b const = 9.1 ( 1.3 ) × 10 − 6 eV/pixel/day was achieved allowing for a reliable analysis of the end-point region. The derived end-point energy Q = 2862 ( 4 ) eV is in excellent agreement with the one independently determined via Penning-trap mass spectrometry of Q = 2863.2 ( 6 ) eV [Ch. Schweiger , ]. The upper limit of the effective electron neutrino mass is improved by almost a factor of 2 compared to the lowest current value [B. K. Alpert , ], reaching m ν e < 15 eV / c 2 (90% credible interval).
- Open Access
- 12 June 2024
- Published by Wiley in Advanced Quantum Technologies
- Vol. 7 (9)
In Situ‐Tunable Spin–Spin Interactions in a Penning Trap with In‐Bore Optomechanics
Experimental implementations of quantum simulation must balance control‐field‐induced decoherence with the controllability of the quantum system. The ratio of coherent interaction strength to decoherence induced by stimulated emission in atomic systems is typically determined by hardware constraints, limiting the flexibility needed to explore different operating regimes. Here, an optomechanical system is presented for in situ tuning of the coherent spin‐motion and spin‐spin interaction strength in 2D ion crystals in a Penning trap. Enabled by precision closed‐loop piezo‐actuated positioners integrated into the confined space of a superconducting magnet's bore, the system allows tuning of the angle‐of‐incidence of Raman laser beams up to , governing the ratio of coherent to incoherent light‐matter interaction for fixed optical power. System characterization involves measurements of the induced mean‐field spin precession under the application of an optical dipole force in ion crystals cooled below the Doppler limit through electromagnetically induced transparency cooling. These experiments show approximately a variation in the coherent to incoherent interaction ratio with changing , consistent with theoretical predictions. The system stability is characterized over 6000 s, resulting in a drift rate of h –1 . These technical developments will be crucial in future quantum simulations and sensing applications.
- 12 June 2024
- Published by Wiley in Advanced Quantum Technologies
- Vol. 7 (9)
Open AccessIn Situ‐Tunable Spin–Spin Interactions in a Penning Trap with In‐Bore Optomechanics
Experimental implementations of quantum simulation must balance control‐field‐induced decoherence with the controllability of the quantum system. The ratio of coherent interaction strength to decoherence induced by stimulated emission in atomic systems is typically determined by hardware constraints, limiting the flexibility needed to explore different operating regimes. Here, an optomechanical system is presented for in situ tuning of the coherent spin‐motion and spin‐spin interaction strength in 2D ion crystals in a Penning trap. Enabled by precision closed‐loop piezo‐actuated positioners integrated into the confined space of a superconducting magnet's bore, the system allows tuning of the angle‐of‐incidence of Raman laser beams up to , governing the ratio of coherent to incoherent light‐matter interaction for fixed optical power. System characterization involves measurements of the induced mean‐field spin precession under the application of an optical dipole force in ion crystals cooled below the Doppler limit through electromagnetically induced transparency cooling. These experiments show approximately a variation in the coherent to incoherent interaction ratio with changing , consistent with theoretical predictions. The system stability is characterized over 6000 s, resulting in a drift rate of h –1 . These technical developments will be crucial in future quantum simulations and sensing applications.
- 31 May 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (5) , 054067
Efficient site-resolved imaging and spin-state detection in dynamic two-dimensional ion crystals
Resolving the locations and discriminating the spin states of individual trapped ions with high fidelity is critical for a large class of applications in quantum computing, simulation, and sensing. We report on a method for high-fidelity state discrimination in large two-dimensional (2D) crystals with over 100 trapped ions in a single trapping region, combining a hardware detector and an artificial neural network. A high-data-rate, spatially resolving, single-photon sensitive timestamping detector performs efficient single-shot detection of 2D crystals in a Penning trap, exhibiting rotation at about . We then train an artificial neural network to process the fluorescence photon data in the rest frame of the rotating crystal in order to identify ion locations with a success rate of , accounting for substantial illumination inhomogeneity across the crystal. Finally, employing a time-binned state detection method, we arrive at an average spin-state detection fidelity of . This technique can be used to analyze spatial and temporal correlations in arrays of hundreds of trapped-ion qubits.- 31 May 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (5) , 054067
Efficient site-resolved imaging and spin-state detection in dynamic two-dimensional ion crystals
Resolving the locations and discriminating the spin states of individual trapped ions with high fidelity is critical for a large class of applications in quantum computing, simulation, and sensing. We report on a method for high-fidelity state discrimination in large two-dimensional (2D) crystals with over 100 trapped ions in a single trapping region, combining a hardware detector and an artificial neural network. A high-data-rate, spatially resolving, single-photon sensitive timestamping detector performs efficient single-shot detection of 2D crystals in a Penning trap, exhibiting rotation at about . We then train an artificial neural network to process the fluorescence photon data in the rest frame of the rotating crystal in order to identify ion locations with a success rate of , accounting for substantial illumination inhomogeneity across the crystal. Finally, employing a time-binned state detection method, we arrive at an average spin-state detection fidelity of . This technique can be used to analyze spatial and temporal correlations in arrays of hundreds of trapped-ion qubits.- Open Access
- 22 November 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-10
Enhancing the sensitivity of atom-interferometric inertial sensors using robust control
Atom-interferometric quantum sensors could revolutionize navigation, civil engineering, and Earth observation. However, operation in real-world environments is challenging due to external interference, platform noise, and constraints on size, weight, and power. Here we experimentally demonstrate that tailored light pulses designed using robust control techniques mitigate significant error sources in an atom-interferometric accelerometer. To mimic the effect of unpredictable lateral platform motion, we apply laser-intensity noise that varies up to 20% from pulse-to-pulse. Our robust control solution maintains performant sensing, while the utility of conventional pulses collapses. By measuring local gravity, we show that our robust pulses preserve interferometer scale factor and improve measurement precision by 10× in the presence of this noise. We further validate these enhancements by measuring applied accelerations over a 200 μg range up to 21× more precisely at the highest applied noise level. Our demonstration provides a pathway to improved atom-interferometric inertial sensing in real-world settings.
- 22 November 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-10
Open AccessEnhancing the sensitivity of atom-interferometric inertial sensors using robust control
Atom-interferometric quantum sensors could revolutionize navigation, civil engineering, and Earth observation. However, operation in real-world environments is challenging due to external interference, platform noise, and constraints on size, weight, and power. Here we experimentally demonstrate that tailored light pulses designed using robust control techniques mitigate significant error sources in an atom-interferometric accelerometer. To mimic the effect of unpredictable lateral platform motion, we apply laser-intensity noise that varies up to 20% from pulse-to-pulse. Our robust control solution maintains performant sensing, while the utility of conventional pulses collapses. By measuring local gravity, we show that our robust pulses preserve interferometer scale factor and improve measurement precision by 10× in the presence of this noise. We further validate these enhancements by measuring applied accelerations over a 200 μg range up to 21× more precisely at the highest applied noise level. Our demonstration provides a pathway to improved atom-interferometric inertial sensing in real-world settings.
- Open Access
- 1 September 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (9) , 094702
Fast silicon carbide MOSFET based high-voltage push–pull switch for charge state separation of highly charged ions with a Bradbury–Nielsen gate
In this paper, we report on the development of a fast high-voltage switch, which is based on two enhancement mode N-channel silicon carbide metal–oxide–semiconductor field-effect transistors in push–pull configuration. The switch is capable of switching high voltages up to 600 V on capacitive loads with rise and fall times on the order of 10 ns and pulse widths ≥20 ns. Using this switch, it was demonstrated that, from the charge state distribution of bunches of highly charged ions ejected from an electron beam ion trap with a specific kinetic energy, single charge states can be separated by fast switching of the high voltage applied to a Bradbury–Nielsen Gate with a resolving power of about 100.
- 1 September 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (9) , 094702
Open AccessFast silicon carbide MOSFET based high-voltage push–pull switch for charge state separation of highly charged ions with a Bradbury–Nielsen gate
In this paper, we report on the development of a fast high-voltage switch, which is based on two enhancement mode N-channel silicon carbide metal–oxide–semiconductor field-effect transistors in push–pull configuration. The switch is capable of switching high voltages up to 600 V on capacitive loads with rise and fall times on the order of 10 ns and pulse widths ≥20 ns. Using this switch, it was demonstrated that, from the charge state distribution of bunches of highly charged ions ejected from an electron beam ion trap with a specific kinetic energy, single charge states can be separated by fast switching of the high voltage applied to a Bradbury–Nielsen Gate with a resolving power of about 100.
- 6 May 2020
- Published by Springer Nature in Nature
- Vol. 581 (7806) , 42-46
Detection of metastable electronic states by Penning trap mass spectrometry
State-of-the-art optical clocks1 achieve precisions of 10−18 or better using ensembles of atoms in optical lattices2,3 or individual ions in radio-frequency traps4,5. Promising candidates for use in atomic clocks are highly charged ions6 (HCIs) and nuclear transitions7, which are largely insensitive to external perturbations and reach wavelengths beyond the optical range8 that are accessible to frequency combs9. However, insufficiently accurate atomic structure calculations hinder the identification of suitable transitions in HCIs. Here we report the observation of a long-lived metastable electronic state in an HCI by measuring the mass difference between the ground and excited states in rhenium, providing a non-destructive, direct determination of an electronic excitation energy. The result is in agreement with advanced calculations. We use the high-precision Penning trap mass spectrometer PENTATRAP to measure the cyclotron frequency ratio of the ground state to the metastable state of the ion with a precision of 10−11—an improvement by a factor of ten compared with previous measurements10,11. With a lifetime of about 130 days, the potential soft-X-ray frequency reference at 4.96 × 1016 hertz (corresponding to a transition energy of 202 electronvolts) has a linewidth of only 5 × 10−8 hertz and one of the highest electronic quality factors (1024) measured experimentally so far. The low uncertainty of our method will enable searches for further soft-X-ray clock transitions8,12 in HCIs, which are required for precision studies of fundamental physics6.
- 6 May 2020
- Published by Springer Nature in Nature
- Vol. 581 (7806) , 42-46
Detection of metastable electronic states by Penning trap mass spectrometry
State-of-the-art optical clocks1 achieve precisions of 10−18 or better using ensembles of atoms in optical lattices2,3 or individual ions in radio-frequency traps4,5. Promising candidates for use in atomic clocks are highly charged ions6 (HCIs) and nuclear transitions7, which are largely insensitive to external perturbations and reach wavelengths beyond the optical range8 that are accessible to frequency combs9. However, insufficiently accurate atomic structure calculations hinder the identification of suitable transitions in HCIs. Here we report the observation of a long-lived metastable electronic state in an HCI by measuring the mass difference between the ground and excited states in rhenium, providing a non-destructive, direct determination of an electronic excitation energy. The result is in agreement with advanced calculations. We use the high-precision Penning trap mass spectrometer PENTATRAP to measure the cyclotron frequency ratio of the ground state to the metastable state of the ion with a precision of 10−11—an improvement by a factor of ten compared with previous measurements10,11. With a lifetime of about 130 days, the potential soft-X-ray frequency reference at 4.96 × 1016 hertz (corresponding to a transition energy of 202 electronvolts) has a linewidth of only 5 × 10−8 hertz and one of the highest electronic quality factors (1024) measured experimentally so far. The low uncertainty of our method will enable searches for further soft-X-ray clock transitions8,12 in HCIs, which are required for precision studies of fundamental physics6.
- Open Access
- 16 March 2020
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 124 (11) , 113001
Mass-Difference Measurements on Heavy Nuclides with an Accuracy in the PENTATRAP SpectrometerFirst ever measurements of the ratios of free cyclotron frequencies of heavy, highly charged ions with with relative uncertainties close to are presented. Such accurate measurements have become realistic due to the construction of the novel cryogenic multi-Penning-trap mass spectrometer PENTATRAP. Based on the measured frequency ratios, the mass differences of five pairs of stable xenon isotopes, ranging from to , have been determined. Moreover, the first direct measurement of an electron binding energy in a heavy highly charged ion, namely of the 37th atomic electron in xenon, with an uncertainty of a few eV is demonstrated. The obtained value agrees with the calculated one using two independent, different implementations of the multiconfiguration Dirac-Hartree-Fock method. PENTATRAP opens the door to future measurements of electron binding energies in highly charged heavy ions for more stringent tests of bound-state quantum electrodynamics in strong electromagnetic fields and for an investigation of the manifestation of light dark matter in isotopic chains of certain chemical elements.- 16 March 2020
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 124 (11) , 113001
Open AccessMass-Difference Measurements on Heavy Nuclides with an Accuracy in the PENTATRAP SpectrometerFirst ever measurements of the ratios of free cyclotron frequencies of heavy, highly charged ions with with relative uncertainties close to are presented. Such accurate measurements have become realistic due to the construction of the novel cryogenic multi-Penning-trap mass spectrometer PENTATRAP. Based on the measured frequency ratios, the mass differences of five pairs of stable xenon isotopes, ranging from to , have been determined. Moreover, the first direct measurement of an electron binding energy in a heavy highly charged ion, namely of the 37th atomic electron in xenon, with an uncertainty of a few eV is demonstrated. The obtained value agrees with the calculated one using two independent, different implementations of the multiconfiguration Dirac-Hartree-Fock method. PENTATRAP opens the door to future measurements of electron binding energies in highly charged heavy ions for more stringent tests of bound-state quantum electrodynamics in strong electromagnetic fields and for an investigation of the manifestation of light dark matter in isotopic chains of certain chemical elements. - 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 123201
Production of highly charged ions of rare species by laser-induced desorption inside an electron beam ion trap
This paper reports on the development and testing of a novel, highly efficient technique for the injection of very rare species into electron beam ion traps (EBITs) for the production of highly charged ions (HCI). It relies on in-trap laser-induced desorption of atoms from a sample brought very close to the electron beam resulting in a very high capture efficiency in the EBIT. We have demonstrated a steady production of HCI of the stable isotope 165Ho from samples of only 1012 atoms (∼300 pg) in charge states up to 45+. HCI of these species can be subsequently extracted for use in other experiments or stored in the trapping volume of the EBIT for spectroscopic measurements. The high efficiency of this technique extends the range of rare isotope HCIs available for high-precision atomic mass and spectroscopic measurements. A first application of this technique is the production of HCI of the synthetic radioisotope 163Ho for a high-precision measurement of the QEC-value of the electron capture in 163Ho within the “Electron Capture in Holmium” experiment [L. Gastaldo et al., J. Low Temp. Phys. 176, 876–884 (2014); L. Gastaldo et al., Eur. Phys. J.: Spec. Top. 226, 1623–1694 (2017)] (ECHo collaboration) ultimately leading to a measurement of the electron neutrino mass with an uncertainty on the sub electronvolt level.
- 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 123201
Production of highly charged ions of rare species by laser-induced desorption inside an electron beam ion trap
This paper reports on the development and testing of a novel, highly efficient technique for the injection of very rare species into electron beam ion traps (EBITs) for the production of highly charged ions (HCI). It relies on in-trap laser-induced desorption of atoms from a sample brought very close to the electron beam resulting in a very high capture efficiency in the EBIT. We have demonstrated a steady production of HCI of the stable isotope 165Ho from samples of only 1012 atoms (∼300 pg) in charge states up to 45+. HCI of these species can be subsequently extracted for use in other experiments or stored in the trapping volume of the EBIT for spectroscopic measurements. The high efficiency of this technique extends the range of rare isotope HCIs available for high-precision atomic mass and spectroscopic measurements. A first application of this technique is the production of HCI of the synthetic radioisotope 163Ho for a high-precision measurement of the QEC-value of the electron capture in 163Ho within the “Electron Capture in Holmium” experiment [L. Gastaldo et al., J. Low Temp. Phys. 176, 876–884 (2014); L. Gastaldo et al., Eur. Phys. J.: Spec. Top. 226, 1623–1694 (2017)] (ECHo collaboration) ultimately leading to a measurement of the electron neutrino mass with an uncertainty on the sub electronvolt level.