HKHiroaki Kurihara

Hiroaki Kurihara

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hiroaki Kurihara has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    64Cu2+ Complexes of Tripodal Amine Ligands’ In Vivo Tumor and Liver Uptakes and Intracellular Cu Distribution in the Extrahepatic Bile Duct Carcinoma Cell Line TFK-1: A Basic Comparative Study

    by Mitsuhiro Shinada, Masashi Takahashi, Chika Igarashi, Hiroki Matsumoto, Fukiko Hihara, Tomoko Tachibana, Masakazu Oikawa, Hisashi Suzuki, Ming-Rong Zhang, Tatsuya Higashi, et al.

    Copper (Cu) is a critical element for cancer cell proliferation and considerably accumulates in the nucleus. 64Cu2+ is an anticancer radiopharmaceutical that targets the copper requirement of cancer cells. However, intravenously injected 64Cu2+ ions primarily accumulate in the liver. Ligand complexation of 64Cu2+ may be a promising method for increasing tumor delivery by reducing liver uptake. In this study, we used three tripodal amine ligands [tris(2-aminoethyl)amine (Tren), diethylenetriamine (Dien), and tris(2-pyridylmethyl)amine (TPMA)] to enclose 64Cu2+ ions and compared their in vivo tumor and liver uptakes using a tumor-bearing xenograft mouse model of the extrahepatic bile duct carcinoma cell line TFK-1. We examined intracellular Cu distribution using microparticle-induced X-ray emission (micro-PIXE) analysis of these compounds. 64Cu2+-Tren and 64Cu2+-Dien showed higher tumor uptake than 64Cu2+-TPMA and 64Cu2+ ions in TFK-1 tumors. Among the three 64Cu2+ complexes and 64Cu2+ ions, liver uptake was inversely correlated with tumor uptake. Micro-PIXE analysis showed that in vitro cellular uptake was similar to in vivo tumor uptake, and nuclear delivery was the highest for 64Cu2+-Tren. Conclusively, an inverse correlation between tumor and liver uptake was observed using three 64Cu2+ complexes of tripodal amine ligands and 64Cu2+ ions. These results provide useful information for the future development of anticancer 64Cu radiopharmaceuticals.


  • Open Access

    64Cu2+ Complexes of Tripodal Amine Ligands on In Vivo Tumor and Liver Uptake and Intracellular Cu Distribution in the Extrahepatic Bile Duct Carcinoma Cell Line TFK-1: A Basic Comparative Study

    by Mitsuhiro Shinada, Masashi Takahashi, Chika Igarashi, Hiroki Matsumoto, Fukiko Hihara, Tomoko Tachibana, Masakazu Oikawa, Hisashi Suzuki, Ming-Rong Zhang, Tatsuya Higashi, et al.

    Copper (Cu) is a critical element for cancer cell proliferation and considerably accumulates in the nucleus. 64Cu2+ is an anticancer radiopharmaceuticals targeting the copper requirement of cancer cells. However, intravenously injected 64Cu2+ ions primarily accumulate in the liver. Ligand complexation of 64Cu2+ would be a promising method for increasing tumor delivery by reducing liver uptake. Herein, we used three tripodal amine ligands [tris(2-aminoethyl)amine (Tren), diethylenetriamine (Dien), and tris(2-pyridylmethyl)amine (TPMA)] to enclose 64Cu2+ ions and compared their in vivo tumor and liver uptake using a tumor-bearing xenograft mouse model of the extrahepatic bile duct carcinoma cell line TFK-1. We examined intracellular Cu distribution using microparticle-induced X-ray emission (micro-PIXE) analysis for these compounds. 64Cu2+-Tren and 64Cu2+-Dien showed higher tumor uptake than 64Cu2+-TPMA and 64Cu2+ ions in TFK-1 tumors. Among the three 64Cu2+ complexes and 64Cu2+ ions, liver uptake was inversely correlated with tumor uptake. Micro-PIXE analysis showed that in vitro cellular uptake was similar to in vivo tumor uptake and nuclear delivery was the highest for 64Cu2+-Tren. Conclusively, an inverse correlation between tumor and liver uptake was observed using three 64Cu2+ complexes of tripodal amine ligands and 64Cu2+ ions. These results provide useful information for the future development of anticancer 64Cu radiopharmaceuticals.

  • Open Access

    Trace Metal Impurities Effects on the Formation of [64Cu]Cu-diacetyl-bis(N4-methylthiosemicarbazone) ([64Cu]Cu-ATSM)

    by Mitsuhiro Shinada, Hisashi Suzuki, Masayuki Hanyu, Chika Igarashi, Hiroki Matsumoto, Masashi Takahashi, Fukiko Hihara, Tomoko Tachibana, Chizuru Sogawa, Ming-Rong Zhang, et al.

    [64Cu]Cu-diacetyl-bis(N4-methylthiosemicarbazone) ([64Cu]Cu-ATSM) is a radioactive hypoxia-targeting therapeutic agent being investigated in clinical trials for malignant brain tumors. For the quality management of [64Cu]Cu-ATSM, understanding trace metal impurities’ effects on the chelate formation of 64Cu and ATSM is important. In this study, we conducted coordination chemistry studies on metal–ATSM complexes. First, the effects of nonradioactive metal ions (Cu2+, Ni2+, Zn2+, and Fe2+) on the formation of [64Cu]Cu-ATSM were evaluated. When the amount of Cu2+ or Ni2+ added was 1.2 mol or 288 mol, equivalent to ATSM, the labeling yield of [64Cu]Cu-ATSM fell below 90%. Little effect was observed even when excess amounts of Zn2+ or Fe2+ were added to the ATSM. Second, these metals were reacted with ATSM, and chelate formation was measured using ultraviolet–visible (UV-Vis) absorption spectra. UV-Vis spectra showed a rapid formation of Cu2+ and the ATSM complex upon mixing. The rate of chelate formation by Ni2+ and ATSM was lower than that by Cu-ATSM. Zn2+ and Fe2+ showed much slower reactions with the ATSM than Ni2+. Trace amounts of Ni2+, Zn2+, and Fe2+ showed little effect on [64Cu]Cu-ATSM’ quality, while the concentration of impurity Cu2+ must be controlled. These results can provide process management tools for radiopharmaceuticals.


  • Open Access

    Process to Remove the Size Variants Contained in the Antibody–Chelator Complex PCTA-NCAB001 for Radiolabeling with Copper-64

    by Yukie Yoshii, Hiroki Matsumoto, Chika Igarashi, Tomoko Tachibana, Fukiko Hihara, Mitsuhiro Shinada, Atsuo Waki, Sei Yoshida, Kenichiro Naito, Kimiteru Ito, et al.

    Understanding the physicochemical properties of antibody–drug conjugates is critical to assess their quality at manufacturing and monitor them during subsequent storage. For radiometal–antibody complexes, it is important to control the properties of the antibody–chelator conjugate to maintain the quality of the final product. We have been developing 64Cu-labeled anti-epidermal growth factor receptor antibody NCAB001 (64Cu-NCAB001) for the early diagnosis and therapy of pancreatic cancer with positron-emission tomography. Here, we characterized the larger size variants contained in the antibody–chelator conjugate PCTA-NCAB001 by multi-angle light scattering coupled with size-exclusion chromatography. Secondly, we developed a chromatographic method to remove these size variants. Lastly, we demonstrated the stability of PCTA-NCAB001 after the removal of size variants. Dimer and oligomers were identified in PCTA-NCAB001. These larger size variants, together with some smaller size variants, could be removed by hydrophobic interaction chromatography. The PCTA-NCAB001 product, after the removal of these size variants, could be stored at 4 °C for six months. The methods developed here can be applied to assure the quality of PCTA-NCAB001 and other antibody–drug conjugates to facilitate the development of antibody–radiometal conjugates for positron-emission tomography and radioimmunotherapy of malignant cancers.

  • Open Access

    Preclinical Safety Evaluation of Intraperitoneally Administered Cu-Conjugated Anti-EGFR Antibody NCAB001 for the Early Diagnosis of Pancreatic Cancer Using PET

    by Hiroki Matsumoto, Chika Igarashi, Tomoko Tachibana, Fukiko Hihara, Mitsuhiro Shinada, Atsuo Waki, Sei Yoshida, Kenichiro Naito, Hiroaki Kurihara, Makoto Ueno, et al.

    Detecting tumor lesions 64Cu-labeled anti-epidermal growth factor receptor (EGFR) antibody (64Cu-NCAB001 ipPET). Here, we conducted an extended single-dose toxicity study of 64Cu-NCAB001 ipPET in mice based on approach 1 of the current ICH M3 [R2] guideline, as our new drug formulation contains 45 μg of the antibody. We used NCAB001 labeled with stable copper isotope instead of 64Cu. The total content of size variants was approximately 6.0% throughout the study. The relative binding potency of Cu-NCAB001 to recombinant human EGFR was comparable to that of cetuximab. The general and neurological toxicities of Cu-NCAB001 ipPET at 62.5 or 625 μg/kg were assessed in mice. The no-observed-adverse-effect level of Cu-NCAB001 was 625 μg/kg, a dose approximately 1000-fold higher at the μg/kg level than the dose of 64Cu-NCAB001 in our formulation (45 µg). The size variants did not affect the safety of the formulation. Therefore, clinical studies on the efficacy of 64Cu-NCAB001 ipPET for early detection of pancreatic cancer using PET imaging can be safely conducted.


  • Open Access

    In Vitro Tumor Cell-Binding Assay to Select High-Binding Antibody and Predict Therapy Response for Personalized 64Cu-Intraperitoneal Radioimmunotherapy against Peritoneal Dissemination of Pancreatic Cancer: A Feasibility Study

    by Fukiko Hihara, Hiroki Matsumoto, Mitsuyoshi Yoshimoto, Takashi Masuko, Yuichi Endo, Chika Igarashi, Tomoko Tachibana, Mitsuhiro Shinada, Ming-Rong Zhang, Gene Kurosawa, et al.

    Peritoneal dissemination of pancreatic cancer has a poor prognosis. We have reported that intraperitoneal radioimmunotherapy using a 64Cu-labeled antibody (64Cu-ipRIT) is a promising adjuvant therapy option to prevent this complication. To achieve personalized 64Cu-ipRIT, we developed a new in vitro tumor cell-binding assay (64Cu-TuBA) system with a panel containing nine candidate 64Cu-labeled antibodies targeting seven antigens (EGFR, HER2, HER3, TfR, EpCAM, LAT1, and CD98), which are reportedly overexpressed in patients with pancreatic cancer. We investigated the feasibility of 64Cu-TuBA to select the highest-binding antibody for individual cancer cell lines and predict the treatment response in vivo for 64Cu-ipRIT. 64Cu-TuBA was performed using six human pancreatic cancer cell lines. For three cell lines, an in vivo treatment study was performed with 64Cu-ipRIT using high-, middle-, or low-binding antibodies in each peritoneal dissemination mouse model. The high-binding antibodies significantly prolonged survival in each mouse model, while low-and middle-binding antibodies were ineffective. There was a correlation between in vitro cell binding and in vivo therapeutic efficacy. Our findings suggest that 64Cu-TuBA can be used for patient selection to enable personalized 64Cu-ipRIT. Tumor cells isolated from surgically resected tumor tissues would be suitable for analysis with the 64Cu-TuBA system in future clinical studies.


  • Open Access

    Characterization and Stabilization of a New 64Cu-Labeled Anti-EGFR Antibody NCAB001 for the Early Detection of Pancreatic Cancer with Positron Emission Tomography

    by Hiroki Matsumoto, Chika Igarashi, Tomoko Tachibana, Fukiko Hihara, Atsuo Waki, Ming-Rong Zhang, Sei Yoshida, Kenichiro Naito, Hiroaki Kurihara, Makoto Ueno, et al.

    Early diagnosis of pancreatic cancer using current imaging modalities remains challenging. We have developed a new approach to identify tumor lesions ≥ 3 mm in the pancreas by positron emission tomography (PET) with a new intraperitoneally administered 64Cu-labeled anti-epidermal growth factor receptor (EGFR) antibody (encoded as NCAB001), called 64Cu-NCAB001 ipPET. Generally, in clinical research, a radiometal-antibody complex must be prepared immediately before use at the imaging site. To make 64Cu-NCAB001 ipPET available to daily clinical practices in a sustainable way, the NCAB001-chelator conjugate and 64Cu-NCAB001 must be characterized and stabilized. NCAB001 was manufactured under cGMP conditions. NCAB001 was conjugated with a bifunctional chelator (p-SCN-Bn-PCTA), and the antibody-chelator conjugate (PCTA-NCAB001) was characterized by LC/MS and ELISA. Thereafter, to effectively manufacture 64Cu-NCAB001, we developed a new formulation to stabilize PCTA-NCAB001 and 64Cu-NCAB001. An average of three PCTA chelators were conjugated per molecule of NCAB001. The relative binding potency of PCTA-NCAB001 was comparable to cetuximab. The formulation consisting of acetate buffer, glycine, and polysorbate-80 stabilized PCTA-NCAB001 for a year-long storage. Additionally, this formulation enabled the stabilization of 64Cu-NCAB001 for up to 24 h after radiolabeling with a sufficient radioactivity concentration for clinical use. These results may accelerate the future use of 64Cu-NCAB001 ipPET in clinical settings for the early diagnosis and treatment of pancreatic cancer.


  • Open Access

    Evaluation of 64Cu-Labeled New Anti-EGFR Antibody NCAB001 with Intraperitoneal Injection for Early PET Diagnosis of Pancreatic Cancer in Orthotopic Tumor-Xenografted Mice and Nonhuman Primates

    by Hiroki Matsumoto, Tadashi Watabe, Chika Igarashi, Tomoko Tachibana, Fukiko Hihara, Atsuo Waki, Ming-Rong Zhang, Hideaki Tashima, Taiga Yamaya, Kazuhiro Ooe, et al.

    Objectives: To improve the prognosis of pancreatic cancer, new imaging methods to identify tumor lesions at a size of 64Cu-labeled new anti-epidermal growth factor receptor (EGFR) antibody (encoded as NCAB001), called 64Cu-NCAB001 ipPET. Methods: NCAB001 was manufactured under cGMP conditions and labeled with 64Cu. The radiochemical and biological properties of 64Cu-NCAB001 were evaluated. Tumor uptake of an ip-administered 64Cu-NCAB001 in mice with orthotopic pancreatic tumor xPA1-DC xenografts was also evaluated. Pharmacokinetics and radiation dosimetry were examined using PET images acquired after the ip administration of 64Cu-NCAB001 into cynomolgus monkeys with pharmacologic safety monitoring. Results: Radio-chromatography, cell-binding assays, and biodistribution of 64Cu-NCAB001 in mice were identical to those of our previous data with clinically available cetuximab. Small tumor lesions in the pancreas (≥3 mm) of mice could be identified by 64Cu-NCAB001 ipPET. The ip administration of 64Cu-NCAB001 into monkeys was safely conducted using ultrasound imaging. PET images in monkeys showed that ip-administered 64Cu-NCAB001 was distributed throughout the intraperitoneal cavity for up to 6 h and cleared thereafter. Most of the radioactivity was distributed in the liver and the large intestine. The radioactivity around the pancreas became negligible 24 h after administration. The estimated human effective dose was 0.0174 mSv/MBq. Conclusion: Our data support the initiation of clinical trials of 64Cu-NCAB001 ipPET to transfer this promising tool for the early diagnosis of pancreatic cancers.


  • Comparison of 18FBPA uptake with 18FDG uptake in cancer patients

    by Hiroshi Igaki, Satoshi Nakamura, Hiroaki Kurihara, Yoshihisa Abe, Shie Nishioka, Ryo Fujii, Masaru Nakamura, Yuko Nakayama, Takahiro Morita, Hiroyuki Okamoto, et al.