ChungHwei Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
ChungHwei Su has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
ShiuanCheng Wang
Department of Public Safety and Fire Science, Chia Nan University of Pharmacy and Science
7 shared publications- Shiuan-Cheng Wang
Department of Public Safety and Fire Science, Chia Nan University of Pharmacy and Science, Tainan City 717301, Taiwan
6 shared publications - Ryh-Nan Pan
Department of Fire Safety, Taiwan Police College, Taipei City, Taiwan
3 shared publications ChiaYuan Shih
Department of Safety, Health and Environmental Engineering, National Kaohsiung University of Science and Technology, Kaohsiung City, Taiwan
2 shared publicationsLinLung Hsieh
Department of Safety, Health and Environmental Engineering, National Kaohsiung University of Science and Technology
2 shared publicationsRyhNan Pan
Department of Fire Safety, Taiwan Police College
2 shared publications
Latest Publications
- 12 August 2026
- Published by Springer Nature in Fire Technology
- Vol. 62 (6) , 141
Quantifying Smoke Generator Output for Full-Scale Hot Smoke Testing to Enhance the Reliability of Smoke Control Assessment
- 12 August 2026
- Published by Springer Nature in Fire Technology
- Vol. 62 (6) , 141
Quantifying Smoke Generator Output for Full-Scale Hot Smoke Testing to Enhance the Reliability of Smoke Control Assessment
- Open Access
Experimental Study of Air Curtain Smoke Confinement and Vehicle Obstruction Effects in a Modular Scaled Tunnel Model
Air curtain systems have been proposed as a supplementary smoke control strategy for vehicle tunnels, particularly where structural constraints limit the installation or upgrading of conventional ventilation systems. However, most previous studies rely on numerical simulations or fixed experimental facilities, while flexible experimental platforms and the influence of vehicle obstruction on smoke behavior remain less explored. This study experimentally investigates the smoke confinement performance of an air curtain using a 1:18 modular detachable scaled vehicle tunnel model. The modular configuration enables flexible assembly and adjustment of the experimental setup for different test conditions. A series of laboratory experiments was conducted using a liquefied petroleum gas (LPG) burner to simulate a vehicle fire. Temperature measurements and smoke visualization were performed under different air curtain jet velocities and vehicle obstruction conditions to analyze the interaction between the air curtain jet and buoyancy-driven smoke flow. The results show that the air curtain significantly restricts the upstream propagation of hot smoke and modifies the thermal field inside the tunnel. When the jet velocity reached approximately 5 m/s, the temperature in the protected region decreased by about 25–35% compared with the case without an air curtain. In addition, the presence of vehicle models altered the airflow structure and increased heat accumulation in the middle region of the tunnel cross-section. These results demonstrate that the proposed modular tunnel model provides a reliable experimental platform for tunnel fire research and highlights the importance of considering vehicle obstruction effects in tunnel smoke control studies.
Open AccessExperimental Study of Air Curtain Smoke Confinement and Vehicle Obstruction Effects in a Modular Scaled Tunnel Model
Air curtain systems have been proposed as a supplementary smoke control strategy for vehicle tunnels, particularly where structural constraints limit the installation or upgrading of conventional ventilation systems. However, most previous studies rely on numerical simulations or fixed experimental facilities, while flexible experimental platforms and the influence of vehicle obstruction on smoke behavior remain less explored. This study experimentally investigates the smoke confinement performance of an air curtain using a 1:18 modular detachable scaled vehicle tunnel model. The modular configuration enables flexible assembly and adjustment of the experimental setup for different test conditions. A series of laboratory experiments was conducted using a liquefied petroleum gas (LPG) burner to simulate a vehicle fire. Temperature measurements and smoke visualization were performed under different air curtain jet velocities and vehicle obstruction conditions to analyze the interaction between the air curtain jet and buoyancy-driven smoke flow. The results show that the air curtain significantly restricts the upstream propagation of hot smoke and modifies the thermal field inside the tunnel. When the jet velocity reached approximately 5 m/s, the temperature in the protected region decreased by about 25–35% compared with the case without an air curtain. In addition, the presence of vehicle models altered the airflow structure and increased heat accumulation in the middle region of the tunnel cross-section. These results demonstrate that the proposed modular tunnel model provides a reliable experimental platform for tunnel fire research and highlights the importance of considering vehicle obstruction effects in tunnel smoke control studies.
- Open Access
- 29 December 2025
- Published by MDPI AG in Sustainability
- Vol. 18 (1) , 347
Enhancing Fire Safety in Taiwan’s Elderly Welfare Institutions: An Analysis Based on Disaster Management Theory
Elderly welfare institutions in Taiwan have experienced multiple severe fire incidents, with smoke inhalation accounting for the majority of fatalities. Hot smoke can rapidly propagate through interconnected ceiling spaces, complicating evacuation for residents with limited mobility who depend heavily on caregiving staff and external responders. Field inspections conducted in this study indicate that 82% of residents require assisted evacuation, underscoring the critical role of early detection, staff-mediated response, and effective smoke control. Drawing on disaster management theory, this study examines key determinants of fire safety performance in elderly welfare institutions, where caregiving staff are primarily trained in medical care rather than fire safety. A total of 64 licensed institutions in Tainan City were investigated through on-site inspections, structured checklist-based surveys, and statistical analyses of fire protection systems. In addition, a comparative review of building and fire safety regulations in Taiwan, the United States, Japan, and China was conducted to contextualize the findings. Using the defense-in-depth framework, this study proposes a three-layer fire safety strategy comprising (1) prevention of fire occurrence, (2) rapid fire detection and early suppression, and (3) containment of fire and smoke spread. From a sustainability perspective, this study conceptualizes fire safety in elderly welfare institutions as a problem of risk governance, illustrating how defense-in-depth can be operationalized as a governance-oriented framework for managing fire and smoke risks, safeguarding vulnerable older adults, and sustaining the resilience and continuity of long-term care systems in an aging society.
- 29 December 2025
- Published by MDPI AG in Sustainability
- Vol. 18 (1) , 347
Open AccessEnhancing Fire Safety in Taiwan’s Elderly Welfare Institutions: An Analysis Based on Disaster Management Theory
Elderly welfare institutions in Taiwan have experienced multiple severe fire incidents, with smoke inhalation accounting for the majority of fatalities. Hot smoke can rapidly propagate through interconnected ceiling spaces, complicating evacuation for residents with limited mobility who depend heavily on caregiving staff and external responders. Field inspections conducted in this study indicate that 82% of residents require assisted evacuation, underscoring the critical role of early detection, staff-mediated response, and effective smoke control. Drawing on disaster management theory, this study examines key determinants of fire safety performance in elderly welfare institutions, where caregiving staff are primarily trained in medical care rather than fire safety. A total of 64 licensed institutions in Tainan City were investigated through on-site inspections, structured checklist-based surveys, and statistical analyses of fire protection systems. In addition, a comparative review of building and fire safety regulations in Taiwan, the United States, Japan, and China was conducted to contextualize the findings. Using the defense-in-depth framework, this study proposes a three-layer fire safety strategy comprising (1) prevention of fire occurrence, (2) rapid fire detection and early suppression, and (3) containment of fire and smoke spread. From a sustainability perspective, this study conceptualizes fire safety in elderly welfare institutions as a problem of risk governance, illustrating how defense-in-depth can be operationalized as a governance-oriented framework for managing fire and smoke risks, safeguarding vulnerable older adults, and sustaining the resilience and continuity of long-term care systems in an aging society.
- Open Access
- 30 June 2025
- Published by Korea Institute of Fire Science and Engineering in International Journal of Fire Science and Engineering
- Vol. 39 (2) , 164-175
Analysis of Evacuation Scenarios for Elderly Workers in the Workplace: A Case Study of Factory C in Tainan, Taiwan
It is expected that Taiwan will become a super-aged society by 2025. Companies are forced to hire more older workers due to labor shortages. Considering the gradual decline in physical functions among the elderly, it is crucial to adopt appropriate evacuation strategies during emergencies. This study utilizes Pathfinder to simulate the evacuation of the operational area in Factory C, Tainan, Taiwan. A steering mode is employed to model crowd phenomena. Scenarios are set up to investigate the differences in evacuation between elderly workers and regular workers at the same location. The parameters analyzed include the walking speed of the elderly, the impact of obstacles, and the hindrance caused by the opening of fire doors. The results indicate that the evacuation time for elderly workers is 1.32 times longer than that for workers of average age. The simulation results show a variation in the number of people passing through each exit, highlighting the necessity for planning appropriate evacuation routes. The difficulty in opening heavy fire doors significantly affects the evacuation of elderly individuals, suggesting that some factory facilities need to be reassessed to accommodate the increasing number of elderly workers.
- 30 June 2025
- Published by Korea Institute of Fire Science and Engineering in International Journal of Fire Science and Engineering
- Vol. 39 (2) , 164-175
Open AccessAnalysis of Evacuation Scenarios for Elderly Workers in the Workplace: A Case Study of Factory C in Tainan, Taiwan
It is expected that Taiwan will become a super-aged society by 2025. Companies are forced to hire more older workers due to labor shortages. Considering the gradual decline in physical functions among the elderly, it is crucial to adopt appropriate evacuation strategies during emergencies. This study utilizes Pathfinder to simulate the evacuation of the operational area in Factory C, Tainan, Taiwan. A steering mode is employed to model crowd phenomena. Scenarios are set up to investigate the differences in evacuation between elderly workers and regular workers at the same location. The parameters analyzed include the walking speed of the elderly, the impact of obstacles, and the hindrance caused by the opening of fire doors. The results indicate that the evacuation time for elderly workers is 1.32 times longer than that for workers of average age. The simulation results show a variation in the number of people passing through each exit, highlighting the necessity for planning appropriate evacuation routes. The difficulty in opening heavy fire doors significantly affects the evacuation of elderly individuals, suggesting that some factory facilities need to be reassessed to accommodate the increasing number of elderly workers.
- Open Access
Characteristic Analysis of Four Major Nighttime Fire Cases on Fire Safety of Long-Term Care Institutions Using Fire Protection Defense-In-Depth Strategy
Providing high-quality care services and fire safety for long-term care institutions is an important issue in Taiwan, which became an aging society in 2018. The fire incidents in Taiwan over the years show that nighttime fires in care institutions often cause serious casualties. It is necessary not only to understand the causes of serious nighttime fire incidents that have occurred but also to draw lessons from the fires that have been put out without causing injuries. In this study, the top two serious nighttime fire accidents in long-term care institutions in the past two decades in Taiwan were analyzed based on the publicly official and academic literature utilizing fire protection defense-in-depth strategies. For comparison, two other nighttime fire cases with similar scenarios but no casualties were also analyzed in depth about the cause of no casualties. The buildings of the four nighttime fires were equipped with fire protection equipment in their public areas. The theoretical basis of the research is the fire protection defense-in-depth strategy. In both categories of severe casualties and no severe casualties, one was caused by arson and the other one by an electrical fire, with the ignition point of a fire in the storeroom and the other in the ward. However, the end results were quite different. The analyzed results showed that the severe fires lasted for about an hour, while the fires without casualties were put out within 15 min. A well-constructed second layer of defense measures could effectively contain a fire, and an effective third layer of measures could avoid casualties. The death rate of personnel can be reduced from a dozen to zero, and the burning time is also greatly reduced. The results could be used as a reference for emergency measures in long-term care institutions.
Open AccessCharacteristic Analysis of Four Major Nighttime Fire Cases on Fire Safety of Long-Term Care Institutions Using Fire Protection Defense-In-Depth Strategy
Providing high-quality care services and fire safety for long-term care institutions is an important issue in Taiwan, which became an aging society in 2018. The fire incidents in Taiwan over the years show that nighttime fires in care institutions often cause serious casualties. It is necessary not only to understand the causes of serious nighttime fire incidents that have occurred but also to draw lessons from the fires that have been put out without causing injuries. In this study, the top two serious nighttime fire accidents in long-term care institutions in the past two decades in Taiwan were analyzed based on the publicly official and academic literature utilizing fire protection defense-in-depth strategies. For comparison, two other nighttime fire cases with similar scenarios but no casualties were also analyzed in depth about the cause of no casualties. The buildings of the four nighttime fires were equipped with fire protection equipment in their public areas. The theoretical basis of the research is the fire protection defense-in-depth strategy. In both categories of severe casualties and no severe casualties, one was caused by arson and the other one by an electrical fire, with the ignition point of a fire in the storeroom and the other in the ward. However, the end results were quite different. The analyzed results showed that the severe fires lasted for about an hour, while the fires without casualties were put out within 15 min. A well-constructed second layer of defense measures could effectively contain a fire, and an effective third layer of measures could avoid casualties. The death rate of personnel can be reduced from a dozen to zero, and the burning time is also greatly reduced. The results could be used as a reference for emergency measures in long-term care institutions.
- 14 November 2022
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 148 (11) , 4897-4904
Multi-path method based on dynamic and isothermal techniques to evaluate the thermal stability and hazard of 1-butyl-3-methylimidazolium dicyanamide
- 14 November 2022
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 148 (11) , 4897-4904
Multi-path method based on dynamic and isothermal techniques to evaluate the thermal stability and hazard of 1-butyl-3-methylimidazolium dicyanamide
- 3 July 2022
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 22 (3) , 273-288
Visibility analysis by light attenuation ratio recorded with portable camera at the full-scale hot smoke test site
Some countries have enacted the full-scale hot smoke test standards to verify the effectiveness of smoke extraction systems. Unfortunately, the judgment of most performed tests is based on vision and lacks scientific value. It is important to establish a scientific and quantifiable measurement system for visibility judgment in a large space. This paper analyzed the visibility values obtained through the light attenuation in a full-scale hot smoke test site. The quadratic regression relationships between the gray scale values and the attenuation ratios were derived. The visibility of the test site can be also obtained by grayscale analysis of recorded images. A qualified emergency direction light was used as a light source, and a closed-circuit television and a portable camera were adopted for image recording. These images were converted into grayscale pictures to obtain the gray scale values at the center of the bright spot. By comparing with the light attenuation ratio of the quantifiable measurement equipment in front of the light source, the results showed excellent relevance and demonstrated the applicability of the captured images.
- 3 July 2022
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 22 (3) , 273-288
Visibility analysis by light attenuation ratio recorded with portable camera at the full-scale hot smoke test site
Some countries have enacted the full-scale hot smoke test standards to verify the effectiveness of smoke extraction systems. Unfortunately, the judgment of most performed tests is based on vision and lacks scientific value. It is important to establish a scientific and quantifiable measurement system for visibility judgment in a large space. This paper analyzed the visibility values obtained through the light attenuation in a full-scale hot smoke test site. The quadratic regression relationships between the gray scale values and the attenuation ratios were derived. The visibility of the test site can be also obtained by grayscale analysis of recorded images. A qualified emergency direction light was used as a light source, and a closed-circuit television and a portable camera were adopted for image recording. These images were converted into grayscale pictures to obtain the gray scale values at the center of the bright spot. By comparing with the light attenuation ratio of the quantifiable measurement equipment in front of the light source, the results showed excellent relevance and demonstrated the applicability of the captured images.
- Open Access
- 27 May 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-17
Stack effects in tall building fires: a case study of Taiwan old apartment fire
Tainan, a city that prospered early in Taiwan, has a hot and humid atmosphere. Hence, the grilled doors in numerous old buildings for ventilation and lighting to conserve energy. This study analyzed a fire incident that occurred during the late night of March 17, 2019 in a 38-year-old dwelling, where three residents were severely covered with soot. The site investigation showed that eight staircases lead to the same basement, which apparently created a stack effect and a makeup air phenomenon. Numerical simulations have been performed in this study to reconstruct the fire scene, whose results were consistent with the actual fire scene. In particular, the results showed that some staircases in the fire were blackened by smoke, while others acted as makeup air inlets. The temperature at the households’ doors on all floors of Staircase 2, which was closest to the fire, exceeded 60 °C after four minutes. Furthermore, two immediately feasible improvement strategies according to the control volume theory of fluid mechanics were proposed in this study. Firstly, changing the grilled doors in the basement to a closed flat door style could effectively prevent smoke from flowing up in the staircases. Secondly, residents may consider closing the windows of the stairs at night to improve fire safety. The results showed that the chimney effect can be significantly reduced. These improvements could be a reference for other old dwellings to enhance their fire safety.
- 27 May 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-17
Open AccessStack effects in tall building fires: a case study of Taiwan old apartment fire
Tainan, a city that prospered early in Taiwan, has a hot and humid atmosphere. Hence, the grilled doors in numerous old buildings for ventilation and lighting to conserve energy. This study analyzed a fire incident that occurred during the late night of March 17, 2019 in a 38-year-old dwelling, where three residents were severely covered with soot. The site investigation showed that eight staircases lead to the same basement, which apparently created a stack effect and a makeup air phenomenon. Numerical simulations have been performed in this study to reconstruct the fire scene, whose results were consistent with the actual fire scene. In particular, the results showed that some staircases in the fire were blackened by smoke, while others acted as makeup air inlets. The temperature at the households’ doors on all floors of Staircase 2, which was closest to the fire, exceeded 60 °C after four minutes. Furthermore, two immediately feasible improvement strategies according to the control volume theory of fluid mechanics were proposed in this study. Firstly, changing the grilled doors in the basement to a closed flat door style could effectively prevent smoke from flowing up in the staircases. Secondly, residents may consider closing the windows of the stairs at night to improve fire safety. The results showed that the chimney effect can be significantly reduced. These improvements could be a reference for other old dwellings to enhance their fire safety.