JXJiawei Xu

Jiawei Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jiawei Xu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Tatsuya Fujino

    Bio-Nano Electronics Research Centre, Toyo University, Kawagoe, Japan

    3 shared publications
  • Tatsuya Fujino

    Department of Applied Chemistry, Graduate School of Science and Engineering, Toyo University, 2100 Kujirai, Kawagoe 350-8585, Japan

    3 shared publications
  • Chihiro Kitaoka

    Criminal Investigation Laboratory, Metropolitan Police Department, 2-1-1 Kasumigaseki, Chiyoda-ku, Tokyo 100-8929, Japan

    1 shared publication
  • Kazuhiko Akiyama

    ‡Department of Chemistry, Graduate School of Science and Engineering, Tokyo Metropolitan University, 1-1 Minami-Osawa, Hachioji-shi, Tokyo 192-0397, Japan

    1 shared publication
  • Kento Kawakita

    Department of Chemistry, Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka 560-8531, Japan

    1 shared publication
  • Mengrui Yang

    Chinese Acad Agr Sci, Inst Qual Stand & Testing Technol Agroprod, Beijing 100081, Peoples R China

    1 shared publication

Latest Publications

  • Open Access

    Molecular Structure-Sensitive Detection in MALDI-MS Utilizing Ag, CdTe, and Water-Splitting Photocatalyst

    by Jiawei Xu, Tatsuya Fujino

    We have developed mold matrices that can be employed to distinguish between enantiomers (D- and L-glucose) and structural isomers (n- and iso-stearic acid) in matrix-assisted laser desorption/ionization mass spectrometry. Utilizing a temperature-responsive polymer, a molecular structure recognition film was created around metal or semiconductor particles, such as silver (Ag) or cadmium telluride (CdTe), forming the core. Molecules that fit the template structure were selectively ionized. To elucidate the properties of the mold matrix, the relationship between molecular recognition rate and peak intensity of analyte ion was investigated by varying polymer film thickness around the core. The relationship between molecular recognition rate and hydrophobicity of the template molecule was also examined. It was found that increasing the amount of polymer forming the molecular recognition film improved the molecular recognition rate. However, the peak intensity of the analyte ion decreased. It was also found that using highly hydrophobic molecules as template molecules resulted in high molecular recognition rates. In addition, a water-splitting photocatalyst was synthesized and utilized to fabricate the mold matrix. It was applicable to both positive and negative ion generation while recognizing the molecular structure of the analyte.

  • Quantitative analysis of bisphenol A eluted into canned tomato and mackerel by matrix-assisted laser desorption ionization mass spectrometry using anthracene as matrix

    by Jiawei Xu, Tatsuya Fujino

    Quantitative analysis of bisphenol A (BPA) was performed by matrix-assisted laser desorption ionization mass spectrometry. It was found that BPA was ionized as deprotonated species when anthracene was used as the matrix. A peak of deprotonated BPA and a peak assignable to epoxy resin were observed on analysis of liquids in canned tomato and mackerel samples. In addition, many identical peaks were observed from the liquids in both cans, indicating that epoxy resin was degraded and BPA was eluted into the canned tomato and mackerel during the storage period. It was suggested that the mackerel heat-treatment process and the acidity of tomato were responsible for the elution of BPA. Using bisphenol B (BPB) as the internal standard, the concentrations of BPA were determined to be 0.55 ± 0.05 and 1.72 ± 0.13 ng/µL (µg/mL) for the canned tomato and mackerel samples, respectively. These canned products were imported goods, and their BPA levels exceeded the safe concentration recommended by The Can Manufacturers Institute of Japan. The results indicate that consumers should exercise caution when consuming canned products particularly those manufactured overseas, which have different safety standards. Graphical abstract

  • Open Access

    Detection of Acetaminophen and Its Glucuronide in Fingerprint by SALDI Mass Spectrometry Using Zeolite and Study of Time-Dependent Changes in Detected Ion Amount

    by Toshiki Horikoshi, Chihiro Kitaoka, Yosuke Fujii, Takashi Asano, Jiawei Xu, Tatsuya Fujino

    The ingredients of an antipyretic (acetaminophen, AAP) and their metabolites excreted into fingerprint were detected by surface-assisted laser desorption ionization (SALDI) mass spectrometry using zeolite. In the fingerprint taken 4 h after AAP ingestion, not only AAP but also the glucuronic acid conjugate of AAP (GAAP), caffeine (Caf), ethenzamide (Eth), salicylamide (Sala; a metabolite of Eth), and urea were detected. Fingerprints were collected over time to determine how the amounts of AAP and its metabolite changed with time, and the time dependence of the peak intensities of protonated AAP and GAAP was measured. It was found that the increase of [GAAP+H]+ peak started later than that of [AAP+H]+ peak, reflecting the metabolism of AAP. Both AAP and GAAP reached maximum concentrations approximately 3 h after ingestion, and were excreted from the body with a half-life of approximately 3.3 h. In addition, fingerprint preservation was confirmed by optical microscopy, and fingerprint shape was retained even after laser irradiation of the fingerprint. Our method may be used in fingerprint analysis.


  • Open Access

    Metal Nanoparticles Loaded on Zeolite for Laser Desorption/Ionization Mass Spectrometry of Low-molecular-weight Compounds

    by Jiawei Xu, Tatsuya Fujino

    The application of metal nano-particles in laser desorption ionization mass spectrometry has been widely studied. Compared with tradition matrix-assisted laser desorption ionization (MALDI) methods, metal nano-particles have advantages, such as the suppression of fragment peaks, clear background of the mass spectrum, enhanced sensitivity and higher selectivity. Furthermore, some molecules that are difficult to be ionized with traditional MALDI can possibly be ionized by metal nano-particles. However, using metal nano-particles alone always achieves the aggregation of nano-particles, resulting in a low ionization efficiency. To overcome this drawback, our group developed a method involving combined metal nano-particles with one kind of aluminosilicate, zeolite, which can prevent aggregation and make the ionization process more smooth. In this paper, we will introduce applications using this combination to detect low-molecular-weight compounds with MALDI mass spectrometry.

  • Analyte-Size-Dependent Ionization and Quantification of Monosaccharides in Human Plasma Using Cation-Exchanged Smectite Layers

    by Yuqi Ding, Kento Kawakita, Jiawei Xu, Kazuhiko Akiyama, Tatsuya Fujino

    Smectite, a synthetic inorganic polymer with a saponite structure, was subjected to matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). Typical organic matrix molecules 2,4,6-trihydroxyacetophenone (THAP) and 2,5-dihydroxybenzoic acid (DHBA) were intercalated into the layer spacing of cation-exchanged smectite, and the complex was used as a new matrix for laser desorption/ionization mass spectrometry. Because of layer spacing limitations, only a small analyte that could enter the layer and bind to THAP or DHBA could be ionized. This was confirmed by examining different analyte/matrix preparation methods and by measuring saccharides with different molecular sizes. Because of the homogeneous distribution of THAP molecules in the smectite layer spacing, high reproducibility of the analyte peak intensity was achieved. By using isotope-labeled (13)C6-d-glucose as the internal standard, quantitative analysis of monosaccharides in pretreated human plasma sample was performed, and the value of 8.6 ± 0.3 μg/mg was estimated.