Kaylee Judith Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kaylee Judith Smith has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Sunitha Nagrath
Department of Chemical Engineering, University of Michigan, Ann Arbor, MI, USA.
2 shared publications Blythe H. Kitner
Northern Illinois University, DeKalb, IL
1 shared publication- Brittany Rupp
Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
1 shared publication Christopher Leu
Perlmutter Cancer Center and Department of Surgery, NYU Langone Health, New York, USA
1 shared publication- Daniel J. Romero
Division of Vestibular Sciences, Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
1 shared publication Diane M. Simeone
Perlmutter Cancer Center and Department of Surgery, NYU Langone Health, New York, USA
1 shared publication
Latest Publications
- Open Access
- 16 July 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (14) , 7852
Integrated Workflow for the Label-Free Isolation and Genomic Analysis of Single Circulating Tumor Cells in Pancreatic Cancer
As pancreatic cancer is the third deadliest cancer in the U.S., the ability to study genetic alterations is necessary to provide further insight into potentially targetable regions for cancer treatment. Circulating tumor cells (CTCs) represent an especially aggressive subset of cancer cells, capable of causing metastasis and progressing the disease. Here, we present the Labyrinth–DEPArray pipeline for the isolation and analysis of single CTCs. Established cell lines, patient-derived CTC cell lines and freshly isolated CTCs were recovered and sequenced to reveal single-cell copy number variations (CNVs). The resulting CNV profiles of established cell lines showed concordance with previously reported data and highlight several gains and losses of cancer-related genes such as FGFR3 and GNAS. The novel sequencing of patient-derived CTC cell lines showed gains in chromosome 8q, 10q and 17q across both CTC cell lines. The pipeline was used to process and isolate single cells from a metastatic pancreatic cancer patient revealing a gain of chromosome 1q and a loss of chromosome 5q. Overall, the Labyrinth-DEPArray pipeline offers a validated workflow combining the benefits of antigen-free CTC isolation with single cell genomic analysis.
- 16 July 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (14) , 7852
Open AccessIntegrated Workflow for the Label-Free Isolation and Genomic Analysis of Single Circulating Tumor Cells in Pancreatic Cancer
As pancreatic cancer is the third deadliest cancer in the U.S., the ability to study genetic alterations is necessary to provide further insight into potentially targetable regions for cancer treatment. Circulating tumor cells (CTCs) represent an especially aggressive subset of cancer cells, capable of causing metastasis and progressing the disease. Here, we present the Labyrinth–DEPArray pipeline for the isolation and analysis of single CTCs. Established cell lines, patient-derived CTC cell lines and freshly isolated CTCs were recovered and sequenced to reveal single-cell copy number variations (CNVs). The resulting CNV profiles of established cell lines showed concordance with previously reported data and highlight several gains and losses of cancer-related genes such as FGFR3 and GNAS. The novel sequencing of patient-derived CTC cell lines showed gains in chromosome 8q, 10q and 17q across both CTC cell lines. The pipeline was used to process and isolate single cells from a metastatic pancreatic cancer patient revealing a gain of chromosome 1q and a loss of chromosome 5q. Overall, the Labyrinth-DEPArray pipeline offers a validated workflow combining the benefits of antigen-free CTC isolation with single cell genomic analysis.
- Open Access
- 9 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-11
New Labyrinth Microfluidic Device Detects Circulating Tumor Cells Expressing Cancer Stem Cell Marker and Circulating Tumor Microemboli in Hepatocellular Carcinoma
Hepatocellular Carcinoma (HCC) is one of the most lethal cancers with a high mortality and recurrence rate. Circulating tumor cell (CTC) detection offers various opportunities to advance early detection and monitoring of HCC tumors which is crucial for improving patient outcome. We developed and optimized a novel Labyrinth microfluidic device to efficiently isolate CTCs from peripheral blood of HCC patients. CTCs were identified in 88.1% of the HCC patients over different tumor stages. The CTC positivity rate was significantly higher in patients with more advanced HCC stages. In addition, 71.4% of the HCC patients demonstrated CTCs positive for cancer stem cell marker, CD44, suggesting that the major population of CTCs could possess stemness properties to facilitate tumor cell survival and dissemination. Furthermore, 55% of the patients had the presence of circulating tumor microemboli (CTM) which also correlated with advanced HCC stage, indicating the association of CTM with tumor progression. Our results show effective CTC capture from HCC patients, presenting a new method for future noninvasive screening and surveillance strategies. Importantly, the detection of CTCs with stemness markers and CTM provides unique insights into the biology of CTCs and their mechanisms influencing metastasis, recurrence and therapeutic resistance.
- 9 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-11
Open AccessNew Labyrinth Microfluidic Device Detects Circulating Tumor Cells Expressing Cancer Stem Cell Marker and Circulating Tumor Microemboli in Hepatocellular Carcinoma
Hepatocellular Carcinoma (HCC) is one of the most lethal cancers with a high mortality and recurrence rate. Circulating tumor cell (CTC) detection offers various opportunities to advance early detection and monitoring of HCC tumors which is crucial for improving patient outcome. We developed and optimized a novel Labyrinth microfluidic device to efficiently isolate CTCs from peripheral blood of HCC patients. CTCs were identified in 88.1% of the HCC patients over different tumor stages. The CTC positivity rate was significantly higher in patients with more advanced HCC stages. In addition, 71.4% of the HCC patients demonstrated CTCs positive for cancer stem cell marker, CD44, suggesting that the major population of CTCs could possess stemness properties to facilitate tumor cell survival and dissemination. Furthermore, 55% of the patients had the presence of circulating tumor microemboli (CTM) which also correlated with advanced HCC stage, indicating the association of CTM with tumor progression. Our results show effective CTC capture from HCC patients, presenting a new method for future noninvasive screening and surveillance strategies. Importantly, the detection of CTCs with stemness markers and CTM provides unique insights into the biology of CTCs and their mechanisms influencing metastasis, recurrence and therapeutic resistance.
- Open Access
- 1 May 2019
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 30 (5) , 357-362
Impact of Stimulus Polarity on oVEMP Response Using the Belly-Tendon Electrode Montage
Background:One stimulus parameter not well established with respect to the ocular vestibular evoked myogenic potential (oVEMP) is stimulus polarity. Many research studies traditionally record oVEMPs using alternating polarity primarily.Purpose:The purpose of this study was to evaluate the effects of stimulus polarity on the oVEMP response under three different conditions (condensation, rarefaction, and alternating) with updated but established recording procedures—the belly-tendon electrode montage.Research Design:oVEMPs were assessed with changes in stimulus polarity in the seated upright position.Study Sample:Thirty otologically normal participants (60 ears) with no history of hearing or balance disorders and normal middle ear function.Data Collection and Analysis:Five hundred‐hertz air-conducted tone bursts at 95-dB nHL were used to evoke the oVEMP response while recordings were made from the contralateral eye to acoustical stimulation using the belly-tendon electrode montage. Measurements were made using three polarities: alternating, condensation, and rarefaction. Natus Bio-logic AEP hardware and software was used for all data collection and analysis.Results:Condensation stimulus phase provided the largest response amplitude compared with alternating and/or rarefaction. Rarefaction provided the earliest latency among stimulus polarities.Conclusions:Condensation is a more effective stimulus polarity regarding response amplitude when recording the oVEMP. This study further supports the use of the belly-tendon electrode montage for recording the oVEMP response.
- 1 May 2019
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 30 (5) , 357-362
Open AccessImpact of Stimulus Polarity on oVEMP Response Using the Belly-Tendon Electrode Montage
Background:One stimulus parameter not well established with respect to the ocular vestibular evoked myogenic potential (oVEMP) is stimulus polarity. Many research studies traditionally record oVEMPs using alternating polarity primarily.Purpose:The purpose of this study was to evaluate the effects of stimulus polarity on the oVEMP response under three different conditions (condensation, rarefaction, and alternating) with updated but established recording procedures—the belly-tendon electrode montage.Research Design:oVEMPs were assessed with changes in stimulus polarity in the seated upright position.Study Sample:Thirty otologically normal participants (60 ears) with no history of hearing or balance disorders and normal middle ear function.Data Collection and Analysis:Five hundred‐hertz air-conducted tone bursts at 95-dB nHL were used to evoke the oVEMP response while recordings were made from the contralateral eye to acoustical stimulation using the belly-tendon electrode montage. Measurements were made using three polarities: alternating, condensation, and rarefaction. Natus Bio-logic AEP hardware and software was used for all data collection and analysis.Results:Condensation stimulus phase provided the largest response amplitude compared with alternating and/or rarefaction. Rarefaction provided the earliest latency among stimulus polarities.Conclusions:Condensation is a more effective stimulus polarity regarding response amplitude when recording the oVEMP. This study further supports the use of the belly-tendon electrode montage for recording the oVEMP response.