Edgar Alejandro de Leon-Diaz de Leon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Edgar Alejandro de Leon-Diaz de Leon has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Angel Antonio Vértiz-Hernández
Coordinación Académica Región Altiplano, Universidad Autónoma de San Luis Potosí, San Luis Potosí, México
1 shared publication - Antonio Gordillo-Moscoso
Facultad de Medicina, Universidad Autónoma de San Luis Potosí, San Luis Potosi, México
1 shared publication - Juan Manuel López Quijano
Hospital Central Dr. Ignacio Morones Prieto, San Luis Potosí, Mexico
1 shared publication - Rafael Almendra-Pegueros
Institut de Recerca Sant Pau (IR SANT PAU), Barcelona, Spain
1 shared publication - Úrsula Medina
Department of Pharmacology, Facultad de Medicina, Universidad Autónoma de San Luis Potosí, S.L.P, México
1 shared publication
Latest Publications
- 26 October 2020
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 16 (8) , 979-987
New Analytical Method for Simultaneous Analysis of Losartan and E-3174 by HPLC in Human Plasma: Application in Pharmaceutical Science
Background: Losartan, one of the most frequently used drugs in Heart Failure (HF) treatment, could be modified for its bioavailability (BA) by generic formulations and other factors. Hence, the importance of therapeutic drug monitoring. Objective: Development and validation of a simplified analytical method using HPLC for simultaneous quantification of losartan and E-3174 in human plasma samples. The method was tested for determining the pharmacokinetics parameters of HF patients. Methods: Analytical conditions were optimized using a C18 column (4.6 X 50 mm, 3 μm. Thermo Scientific) at 25ºC. Conditions of mobile phase: a phosphate buffer (0.01M), adjusted to pH 2.5 with phosphoric acid (1M) and Acetonitrile (60:40 v/v). The flow rate was maintained at 1.2 mL/min, on a running time of 5 min and a sample injection volume of 50 μL. Absorbance for measurement of losartan and E-3174 was 200 nm. Pharmacokinetics profiles were determined with Phoenix Win- Nonlin 8.1 software in a non-compartmental model. Results: Analytical method developed and validated in this work is precise and accurate for simultaneous determination of losartan and E-3174 in human plasma samples in a range of 0.02 -10 μg/mL. In HF subjects, lower Tmax and higher Cmax for losartan and E-3174 patent than generic formulation were observed, which can be translated into less biological effect and more time to present it by the generic drug. Conclusion: The pharmacokinetic profile is dependent on the type of formulation studied (generic/ patent) hence the importance of conducting evaluations in our patients to ensure that the expected therapeutic effect is achieved with treatment administered.
- 26 October 2020
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 16 (8) , 979-987
New Analytical Method for Simultaneous Analysis of Losartan and E-3174 by HPLC in Human Plasma: Application in Pharmaceutical Science
Background: Losartan, one of the most frequently used drugs in Heart Failure (HF) treatment, could be modified for its bioavailability (BA) by generic formulations and other factors. Hence, the importance of therapeutic drug monitoring. Objective: Development and validation of a simplified analytical method using HPLC for simultaneous quantification of losartan and E-3174 in human plasma samples. The method was tested for determining the pharmacokinetics parameters of HF patients. Methods: Analytical conditions were optimized using a C18 column (4.6 X 50 mm, 3 μm. Thermo Scientific) at 25ºC. Conditions of mobile phase: a phosphate buffer (0.01M), adjusted to pH 2.5 with phosphoric acid (1M) and Acetonitrile (60:40 v/v). The flow rate was maintained at 1.2 mL/min, on a running time of 5 min and a sample injection volume of 50 μL. Absorbance for measurement of losartan and E-3174 was 200 nm. Pharmacokinetics profiles were determined with Phoenix Win- Nonlin 8.1 software in a non-compartmental model. Results: Analytical method developed and validated in this work is precise and accurate for simultaneous determination of losartan and E-3174 in human plasma samples in a range of 0.02 -10 μg/mL. In HF subjects, lower Tmax and higher Cmax for losartan and E-3174 patent than generic formulation were observed, which can be translated into less biological effect and more time to present it by the generic drug. Conclusion: The pharmacokinetic profile is dependent on the type of formulation studied (generic/ patent) hence the importance of conducting evaluations in our patients to ensure that the expected therapeutic effect is achieved with treatment administered.