Ho-Young Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ho-Young Kim has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Vijay Harid
Department of Electrical Engineering University of Colorado Denver Denver CO USA
4 shared publications - Mark Golkowski
Department of Electrical Engineering University of Colorado Denver Denver CO USA
3 shared publications - Seong-Won Lee
School of Computer and Information Engineering, Kwangwoon University, Seoul, South Korea
3 shared publications Kee-Min Woo
2 shared publicationsM Gołkowski
2 shared publicationsMan-Hee Cho
2 shared publications
Latest Publications
- Open Access
- 1 April 2023
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 947 (2) , 73
Whistler Wave Observations by Parker Solar Probe During Encounter 1: Counter-propagating Whistlers Collocated with Magnetic Field Inhomogeneities and their Application to Electric Field Measurement Calibration
Observations of the young solar wind by the Parker Solar Probe (PSP) mission reveal the existence of intense plasma wave bursts with frequencies between 0.05 and 0.20f ce (tens of hertz up to ∼300 Hz) in the spacecraft frame. The wave bursts are often collocated with inhomogeneities in the solar wind magnetic field, such as local dips in magnitude or sudden directional changes. The observed waves are identified as electromagnetic whistler waves that propagate either sunward, anti-sunward, or in counter-propagating configurations during different burst events. Being generated in the solar wind flow, the waves experience significant Doppler downshift and upshift of wave frequency in the spacecraft frame for sunward and anti-sunward waves, respectively. Their peak amplitudes can be larger than 2 nT, where such values represent up to 10% of the background magnetic field during the interval of study. The amplitude is maximum for propagation parallel to the background magnetic field. We (i) evaluate the properties of these waves by reconstructing their parameters in the plasma frame, (ii) estimate the effective length of the PSP electric field antennas at whistler frequencies, and (iii) discuss the generation mechanism of these waves.
- 1 April 2023
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 947 (2) , 73
Open AccessWhistler Wave Observations by Parker Solar Probe During Encounter 1: Counter-propagating Whistlers Collocated with Magnetic Field Inhomogeneities and their Application to Electric Field Measurement Calibration
Observations of the young solar wind by the Parker Solar Probe (PSP) mission reveal the existence of intense plasma wave bursts with frequencies between 0.05 and 0.20f ce (tens of hertz up to ∼300 Hz) in the spacecraft frame. The wave bursts are often collocated with inhomogeneities in the solar wind magnetic field, such as local dips in magnitude or sudden directional changes. The observed waves are identified as electromagnetic whistler waves that propagate either sunward, anti-sunward, or in counter-propagating configurations during different burst events. Being generated in the solar wind flow, the waves experience significant Doppler downshift and upshift of wave frequency in the spacecraft frame for sunward and anti-sunward waves, respectively. Their peak amplitudes can be larger than 2 nT, where such values represent up to 10% of the background magnetic field during the interval of study. The amplitude is maximum for propagation parallel to the background magnetic field. We (i) evaluate the properties of these waves by reconstructing their parameters in the plasma frame, (ii) estimate the effective length of the PSP electric field antennas at whistler frequencies, and (iii) discuss the generation mechanism of these waves.
- 21 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (3) , 560-565
Trapped Electron Effects in Transient Helium Sub-Nanosecond Atmospheric Microplasmas
For fast rising voltage in planar electrode geometry, it is shown that electrons can be trapped in a potential well between a reversed plasma-driven electric field and the applied electrode voltage. This trapping mechanism occurs in a subset of the inter-electrode gap and leads to increased average electron density in nanosecond discharges. There is a threshold ratio of the applied voltage to rise time for which the electrons experience a pendulum-like motion without any polarity change in the applied voltage. The fast rise time of the driven voltage leads to an enhanced trapped effect and augments the electron density of >5 eV energetic electrons, which can be exploited to produce excited chemical species and high plasma densities on nanosecond timescales.
- 21 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (3) , 560-565
Trapped Electron Effects in Transient Helium Sub-Nanosecond Atmospheric Microplasmas
For fast rising voltage in planar electrode geometry, it is shown that electrons can be trapped in a potential well between a reversed plasma-driven electric field and the applied electrode voltage. This trapping mechanism occurs in a subset of the inter-electrode gap and leads to increased average electron density in nanosecond discharges. There is a threshold ratio of the applied voltage to rise time for which the electrons experience a pendulum-like motion without any polarity change in the applied voltage. The fast rise time of the driven voltage leads to an enhanced trapped effect and augments the electron density of >5 eV energetic electrons, which can be exploited to produce excited chemical species and high plasma densities on nanosecond timescales.
- 22 April 2021
- Published by IOP Publishing in Plasma Research Express
- Vol. 3 (2) , 025003
Rapid ionization of Xe/Ar mixtures in nanosecond discharges exploiting post-pulse field reversals
Enhanced post-pulse electric field reversals of Ar, Xe, and XeAr mixture gases in capacitively coupled nanosecond discharges are investigated with Particle-In-Cell simulations in the context of maximizing electron density. The electric field reversal occurs at the falling edge of the voltage pulse and induces electron oscillatory movement in the plasma bulk region. The amplitude of field reversals is affected by driven voltage and the ratio of bulk length to gap distance. Exploiting the field reversal with a so called Plasma frequency dependent Square Wave (PSW) in an optimal gas mixture leads to the highest electron density. Specifically, for a 250 V PSW XeAr mixture case, the electron density is 2.2 times higher compared to a 1 kV DC pure Xe case even if the driven voltage is 4 times less than DC voltage. In 250 V PSW cases, XeAr mixture plasma has 1.2 times higher average electron density and 1.2 times electron temperature in the sheath region than a pure Xe plasma. With a narrower bulk region, the XeAr plasma has an enhanced field reversal and this leads to higher and faster growing electron density and electron temperature than a Xe plasma. For applications using Xe plasmas, XeAr mixture plasmas with PSW can be exploited for high electron density and temperature at reduced costs.
- 22 April 2021
- Published by IOP Publishing in Plasma Research Express
- Vol. 3 (2) , 025003
Rapid ionization of Xe/Ar mixtures in nanosecond discharges exploiting post-pulse field reversals
Enhanced post-pulse electric field reversals of Ar, Xe, and XeAr mixture gases in capacitively coupled nanosecond discharges are investigated with Particle-In-Cell simulations in the context of maximizing electron density. The electric field reversal occurs at the falling edge of the voltage pulse and induces electron oscillatory movement in the plasma bulk region. The amplitude of field reversals is affected by driven voltage and the ratio of bulk length to gap distance. Exploiting the field reversal with a so called Plasma frequency dependent Square Wave (PSW) in an optimal gas mixture leads to the highest electron density. Specifically, for a 250 V PSW XeAr mixture case, the electron density is 2.2 times higher compared to a 1 kV DC pure Xe case even if the driven voltage is 4 times less than DC voltage. In 250 V PSW cases, XeAr mixture plasma has 1.2 times higher average electron density and 1.2 times electron temperature in the sheath region than a pure Xe plasma. With a narrower bulk region, the XeAr plasma has an enhanced field reversal and this leads to higher and faster growing electron density and electron temperature than a Xe plasma. For applications using Xe plasmas, XeAr mixture plasmas with PSW can be exploited for high electron density and temperature at reduced costs.
- 19 April 2021
- Published by Springer Nature in The European Physical Journal D
- Vol. 75 (4) , 1-10
Enhanced electron density and plasma dynamics on nanosecond time scales in Helium plasma discharges
- 19 April 2021
- Published by Springer Nature in The European Physical Journal D
- Vol. 75 (4) , 1-10
Enhanced electron density and plasma dynamics on nanosecond time scales in Helium plasma discharges
- Open Access
- 19 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (8) , 3665
Numerical Modeling of Nondestructive Testing of Various Conductive Objects inside Metal Enclosures Using ELF/VLF Magnetic Fields
Nondestructive evaluation of various conductive objects through metal enclosures is investigated by using ELF/VLF magnetic induction fields in detailed simulations. ELF/VLF magnetic fields (6 S/m) and high (108 S/m) conductivity metallic shields. It is shown that the responses are quite sensitive to the object and shield parameters; both qualitative and quantitative properties of the field distortions are described in detail. The simulation results suggest that properties of hidden conductive or permeable objects, over a relatively wide range of parameters (both geometry and material), can be inferred nondestructively using ELF/VLF magnetic induction fields.
- 19 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (8) , 3665
Open AccessNumerical Modeling of Nondestructive Testing of Various Conductive Objects inside Metal Enclosures Using ELF/VLF Magnetic Fields
Nondestructive evaluation of various conductive objects through metal enclosures is investigated by using ELF/VLF magnetic induction fields in detailed simulations. ELF/VLF magnetic fields (6 S/m) and high (108 S/m) conductivity metallic shields. It is shown that the responses are quite sensitive to the object and shield parameters; both qualitative and quantitative properties of the field distortions are described in detail. The simulation results suggest that properties of hidden conductive or permeable objects, over a relatively wide range of parameters (both geometry and material), can be inferred nondestructively using ELF/VLF magnetic induction fields.
- Open Access
- 27 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 79745-79753
Imaging Conductive Objects Through Metal Enclosures Using ELF/VLF Magnetic Fields
Imaging through conductive media is a pervasive problem in medical, industrial, and security applications. Several potential modalities such as X-ray, exotic particle beams, and related high resolution techniques have been employed in the past. However, the difficulty of production and safety of these technologies is a concern in practice. Of particular interest in this work are extremely and very low frequency (ELF/VLF, f<30 kHz) radio signals.We consider the feasibility of using ELF/VLF signals for detecting and imaging objects that are hidden inside thin-shelled conductive enclosures. It is shown that the hidden perfect electrical conductor (PEC) object partially blocks the incident magnetic field and results in a magnetic-field depletion that can be used to detect the object. Next, using FEKO simulations, a parametric study of throughconductor detection using a magnetic dipole is considered for a cubic aluminum shield. It is shown that signals above 1 kHz can be used to evaluate the outer shield properties, while signals at frequencies below 200 Hz can be used to effectively discern shapes of hidden objects by observing the magnetic distortion within 1 cm of the outer shield. To validate the results of theory and simulations, experiments matching the simulation conditions are conducted with a cubic aluminum container and hidden aluminum block. The experiments clearly demonstrate the presence of the magnetic field depletion as predicted by theory and simulations. The results of this work suggest that near-field ELF/VLF magnetic induction is an effective method for imaging through realistic metallic shields.
- 27 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 79745-79753
Open AccessImaging Conductive Objects Through Metal Enclosures Using ELF/VLF Magnetic Fields
Imaging through conductive media is a pervasive problem in medical, industrial, and security applications. Several potential modalities such as X-ray, exotic particle beams, and related high resolution techniques have been employed in the past. However, the difficulty of production and safety of these technologies is a concern in practice. Of particular interest in this work are extremely and very low frequency (ELF/VLF, f<30 kHz) radio signals.We consider the feasibility of using ELF/VLF signals for detecting and imaging objects that are hidden inside thin-shelled conductive enclosures. It is shown that the hidden perfect electrical conductor (PEC) object partially blocks the incident magnetic field and results in a magnetic-field depletion that can be used to detect the object. Next, using FEKO simulations, a parametric study of throughconductor detection using a magnetic dipole is considered for a cubic aluminum shield. It is shown that signals above 1 kHz can be used to evaluate the outer shield properties, while signals at frequencies below 200 Hz can be used to effectively discern shapes of hidden objects by observing the magnetic distortion within 1 cm of the outer shield. To validate the results of theory and simulations, experiments matching the simulation conditions are conducted with a cubic aluminum container and hidden aluminum block. The experiments clearly demonstrate the presence of the magnetic field depletion as predicted by theory and simulations. The results of this work suggest that near-field ELF/VLF magnetic induction is an effective method for imaging through realistic metallic shields.
- 18 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (4) , 1225-1236
Magnetic Field Penetration Into a Metal Enclosure Using an ELF/VLF Loop Antenna
The ability of extremely and very low frequency (ELF/VLF, 0–30 kHz) radio waves to penetrate conductive media is well established. Magnetic field penetration into a thin but highly conductive box using an ELF/VLF loop antenna transmitter is investigated. The work is relevant for electromagnetic shielding of ELF/VLF sensors, defect detection, inductive power transfer, and through container imaging. Analytical solutions are reviewed for related shielding problems, however, determining the penetration through a realistic shield geometry and finite sized near-field source requires a numerical approach. Surface integral equation (SIE) methods are well suited for shield modeling due to the low surface area to volume ratio of the shield. Method of moment techniques have been successfully applied to solving SIEs in the past, however, enforcing algorithm stability at low frequencies is known to require considerable effort. To alleviate the low-frequency concerns, a high-order locally corrected Nyström (LCN) scheme is utilized to solve an SIE based on an augmented Müller formulation of Maxwell’s equations. To validate the LCN simulations, an experiment is conducted using a loop antenna inside a 1.2 m aluminum cube of 2.7 mm thickness with an external ELF/VLF loop transmitter. Experimental results are shown to match within 3 dB of the LCN code predictions.
- 18 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (4) , 1225-1236
Magnetic Field Penetration Into a Metal Enclosure Using an ELF/VLF Loop Antenna
The ability of extremely and very low frequency (ELF/VLF, 0–30 kHz) radio waves to penetrate conductive media is well established. Magnetic field penetration into a thin but highly conductive box using an ELF/VLF loop antenna transmitter is investigated. The work is relevant for electromagnetic shielding of ELF/VLF sensors, defect detection, inductive power transfer, and through container imaging. Analytical solutions are reviewed for related shielding problems, however, determining the penetration through a realistic shield geometry and finite sized near-field source requires a numerical approach. Surface integral equation (SIE) methods are well suited for shield modeling due to the low surface area to volume ratio of the shield. Method of moment techniques have been successfully applied to solving SIEs in the past, however, enforcing algorithm stability at low frequencies is known to require considerable effort. To alleviate the low-frequency concerns, a high-order locally corrected Nyström (LCN) scheme is utilized to solve an SIE based on an augmented Müller formulation of Maxwell’s equations. To validate the LCN simulations, an experiment is conducted using a loop antenna inside a 1.2 m aluminum cube of 2.7 mm thickness with an external ELF/VLF loop transmitter. Experimental results are shown to match within 3 dB of the LCN code predictions.
- 1 October 2018
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 27 (10) , 105015
Optimal waveforms for capacitively coupled ionization in nanosecond plasma discharges
Optimal voltage waveforms for capacitively coupled plasma discharges are numerically investigated using a particle-in-cell kinetic model. The focus is on nanosecond time scales where the transient plasma response and charge separation in the plasma can be exploited with precise voltage timing. Square wave and sinusoidal waveforms with a dynamic frequency equal to half of the instantaneous plasma frequency lead to higher plasma density in less time. Using such optimal waveforms, the maximum plasma densities can be increased from 2 to 9 times higher over a standard RF waveform. Conversely, the same density can be achieved in the same duration using half the voltage amplitude as compared to an RF waveform. Plasma density based waveform optimization is applicable in cases where system size is larger than electron mean free path and dominated by electron-neutral collisions.
- 1 October 2018
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 27 (10) , 105015
Optimal waveforms for capacitively coupled ionization in nanosecond plasma discharges
Optimal voltage waveforms for capacitively coupled plasma discharges are numerically investigated using a particle-in-cell kinetic model. The focus is on nanosecond time scales where the transient plasma response and charge separation in the plasma can be exploited with precise voltage timing. Square wave and sinusoidal waveforms with a dynamic frequency equal to half of the instantaneous plasma frequency lead to higher plasma density in less time. Using such optimal waveforms, the maximum plasma densities can be increased from 2 to 9 times higher over a standard RF waveform. Conversely, the same density can be achieved in the same duration using half the voltage amplitude as compared to an RF waveform. Plasma density based waveform optimization is applicable in cases where system size is larger than electron mean free path and dominated by electron-neutral collisions.
- 1 May 2018
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 27 (5) , 055011
PIC simulations of post-pulse field reversal and secondary ionization in nanosecond argon discharges
Post-pulse electric field reversal and secondary ionization are investigated with a full kinetic treatment in argon discharges between planar electrodes on nanosecond time scales. The secondary ionization, which occurs at the falling edge of the voltage pulse, is induced by charge separation in the bulk plasma region. This process is driven by a reverse in the electric field from the cathode sheath to the formerly driven anode. Under the influence of the reverse electric field, electrons in the bulk plasma and sheath regions are accelerated toward the cathode. The electron movement manifests itself as a strong electron current generating high electron energies with significant electron dissipated power. Accelerated electrons collide with Ar molecules and an increased ionization rate is achieved even though the driving voltage is no longer applied. With this secondary ionization, in a single pulse (SP), the maximum electron density achieved is 1.5 times higher and takes a shorter time to reach using 1 kV 2 ns pulse as compared to a 1 kV direct current voltage at 1 Torr. A bipolar dual pulse excitation can increase maximum density another 50%–70% above a SP excitation and in half the time of RF sinusoidal excitation of the same period. The first field reversal is most prominent but subsequent field reversals also occur and correspond to electron temperature increases. Targeted pulse designs can be used to condition plasma density as required for fast discharge applications.
- 1 May 2018
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 27 (5) , 055011
PIC simulations of post-pulse field reversal and secondary ionization in nanosecond argon discharges
Post-pulse electric field reversal and secondary ionization are investigated with a full kinetic treatment in argon discharges between planar electrodes on nanosecond time scales. The secondary ionization, which occurs at the falling edge of the voltage pulse, is induced by charge separation in the bulk plasma region. This process is driven by a reverse in the electric field from the cathode sheath to the formerly driven anode. Under the influence of the reverse electric field, electrons in the bulk plasma and sheath regions are accelerated toward the cathode. The electron movement manifests itself as a strong electron current generating high electron energies with significant electron dissipated power. Accelerated electrons collide with Ar molecules and an increased ionization rate is achieved even though the driving voltage is no longer applied. With this secondary ionization, in a single pulse (SP), the maximum electron density achieved is 1.5 times higher and takes a shorter time to reach using 1 kV 2 ns pulse as compared to a 1 kV direct current voltage at 1 Torr. A bipolar dual pulse excitation can increase maximum density another 50%–70% above a SP excitation and in half the time of RF sinusoidal excitation of the same period. The first field reversal is most prominent but subsequent field reversals also occur and correspond to electron temperature increases. Targeted pulse designs can be used to condition plasma density as required for fast discharge applications.
- 30 October 2016
- Published by The Institute of Electronics Engineers of Korea in IEIE Transactions on Smart Processing & Computing
- Vol. 5 (5) , 310-318
A Consistent Quality Bit Rate Control for the Line-Based Compression
- 30 October 2016
- Published by The Institute of Electronics Engineers of Korea in IEIE Transactions on Smart Processing & Computing
- Vol. 5 (5) , 310-318
A Consistent Quality Bit Rate Control for the Line-Based Compression