Mark D. Lingwood
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mark D. Lingwood has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Steven Jon Bachofer
Saint Mary's College of California Moraga California USA
2 shared publications Alexia Rios
Saint Mary's College of California Moraga California USA
1 shared publicationBenjamin J. Schepergerdes
Department of Chemistry Saint Mary's College of California, 1928 St. Mary's Road Moraga CA 94575 USA
1 shared publicationDeja‐Monae T. Hermosillo
Department of Chemistry Saint Mary's College of California, 1928 St. Mary's Road Moraga CA 94575 USA
1 shared publicationJalissa N. Delgado
Department of Chemistry Saint Mary's College of California, 1928 St. Mary's Road Moraga CA 94575 USA
1 shared publicationJaslyn Salazar
Saint Mary's College of California Moraga California USA
1 shared publication
Latest Publications
- Open Access
- 9 April 2026
- Published by Wiley in Journal of Surfactants and Detergents
- Vol. 29 (4) , 667-676
The Binding of Pentadiyl‐α,ω‐Bis(Dimethyldodecylammonium), a Cationic Gemini 12‐5‐12 Surfactant to Conjugated Carboxylates as Organic Counterions
The critical micelle concentration (CMC) values of the cationic gemini surfactant pentadiyl‐α,ω‐bis(dimethyldodecylammonium) bromide depend on the hydrophobicity of added conjugated organic carboxylate anions. Nine conjugated counterions, present as sodium salts of organic acids, were studied to expand the correlation to the counterion hydrophobicity effect on the CMC. These added salts are sodium benzoate, sodium o‐fluorobenzoate, sodium o‐chlorobenzoate, sodium o‐bromobenzoate, sodium 2,6‐difluorobenzoate, sodium 3,5‐difluorobenzoate, sodium cinnamate, sodium 3,5‐difluorocinnamate, and sodium sorbate. Three methods, conductivity, fluorescence intensity, and NMR chemical shifts, were employed to obtain CMC values. 1D and 2D NMR spectra yield data on the counterion binding to the micellar interface. A straightforward correlation of the Log (CMC) values and the Log P values of the organic acid, which was deprotonated to serve as the counterion, demonstrates the Log P values can be utilized to predict the surfactant aggregation behavior over an extensive range.
- 9 April 2026
- Published by Wiley in Journal of Surfactants and Detergents
- Vol. 29 (4) , 667-676
Open AccessThe Binding of Pentadiyl‐α,ω‐Bis(Dimethyldodecylammonium), a Cationic Gemini 12‐5‐12 Surfactant to Conjugated Carboxylates as Organic Counterions
The critical micelle concentration (CMC) values of the cationic gemini surfactant pentadiyl‐α,ω‐bis(dimethyldodecylammonium) bromide depend on the hydrophobicity of added conjugated organic carboxylate anions. Nine conjugated counterions, present as sodium salts of organic acids, were studied to expand the correlation to the counterion hydrophobicity effect on the CMC. These added salts are sodium benzoate, sodium o‐fluorobenzoate, sodium o‐chlorobenzoate, sodium o‐bromobenzoate, sodium 2,6‐difluorobenzoate, sodium 3,5‐difluorobenzoate, sodium cinnamate, sodium 3,5‐difluorocinnamate, and sodium sorbate. Three methods, conductivity, fluorescence intensity, and NMR chemical shifts, were employed to obtain CMC values. 1D and 2D NMR spectra yield data on the counterion binding to the micellar interface. A straightforward correlation of the Log (CMC) values and the Log P values of the organic acid, which was deprotonated to serve as the counterion, demonstrates the Log P values can be utilized to predict the surfactant aggregation behavior over an extensive range.
- 5 December 2019
- Published by Wiley in Journal of Surfactants and Detergents
- Vol. 23 (2) , 319-325
Probe Molecules for Pulsed‐Field‐Gradient Diffusion Nuclear Magnetic Resonance Experiments on Micelles
Nuclear magnetic resonance (NMR) diffusion measurements of surfactants suffer from fast exchange of the surfactant between the micellar aggregate and bulk solution. Therefore, hydrophobic probe molecules are commonly used to directly measure aggregate diffusion under the assumption that the probe molecules remain solubilized inside the micelles. Aggregate size is then determined or estimated from the aggregate diffusion value. Unfortunately, the probe molecule also experiences rapid exchange between the aggregate and bulk, leading to inaccurate or unreasonable micelle diffusion values, a fact that has often been ignored in the literature. In this article, we present a systematic evaluation of probe molecules in cationic and anionic surfactants, obtained by measuring the diffusion of probe molecules with varying hydrophobicity. We find that an octanol–water partition coefficient of at least ~5 is required for correct measurements of aggregate diffusion in the systems studied. Notably, some commonly used probes have a partition coefficient much lower than five and are therefore not suitable for aggregate diffusion measurements. Consideration of these results will help researchers obtain accurate results for micelle sizing or partitioning studies with pulsed‐field‐gradient NMR.
- 5 December 2019
- Published by Wiley in Journal of Surfactants and Detergents
- Vol. 23 (2) , 319-325
Probe Molecules for Pulsed‐Field‐Gradient Diffusion Nuclear Magnetic Resonance Experiments on Micelles
Nuclear magnetic resonance (NMR) diffusion measurements of surfactants suffer from fast exchange of the surfactant between the micellar aggregate and bulk solution. Therefore, hydrophobic probe molecules are commonly used to directly measure aggregate diffusion under the assumption that the probe molecules remain solubilized inside the micelles. Aggregate size is then determined or estimated from the aggregate diffusion value. Unfortunately, the probe molecule also experiences rapid exchange between the aggregate and bulk, leading to inaccurate or unreasonable micelle diffusion values, a fact that has often been ignored in the literature. In this article, we present a systematic evaluation of probe molecules in cationic and anionic surfactants, obtained by measuring the diffusion of probe molecules with varying hydrophobicity. We find that an octanol–water partition coefficient of at least ~5 is required for correct measurements of aggregate diffusion in the systems studied. Notably, some commonly used probes have a partition coefficient much lower than five and are therefore not suitable for aggregate diffusion measurements. Consideration of these results will help researchers obtain accurate results for micelle sizing or partitioning studies with pulsed‐field‐gradient NMR.
- 1 July 2018
- Published by Walter de Gruyter GmbH in Physical Sciences Reviews
- Vol. 3 (7)
A green determination of an equilibrium constant: teaching new skills
The spectroscopic determination of an equilibrium constant is a classic experiment in the general chemistry laboratory curriculum. Here we describe a new version of this experiment, incorporating green chemistry practices into the general chemistry lab curriculum and directly teaching students about the principles of green chemistry. This lab studies the formation of the iron(III) salicylate complex ion, which is a more benign chemical system than the traditional iron(III) thiocyanate complex. A microtiter plate reader is used to reduce sample volumes, also giving students important experience using research-grade instrumentation. In addition, students gain more experience using adjustable manual micropipettors. Students responded positively to the lab, appreciating the green nature of the lab and the introduction of the plate reader, and student comments suggested that this lab successfully introduces green chemistry concepts to the general chemistry curriculum.
- 1 July 2018
- Published by Walter de Gruyter GmbH in Physical Sciences Reviews
- Vol. 3 (7)
A green determination of an equilibrium constant: teaching new skills
The spectroscopic determination of an equilibrium constant is a classic experiment in the general chemistry laboratory curriculum. Here we describe a new version of this experiment, incorporating green chemistry practices into the general chemistry lab curriculum and directly teaching students about the principles of green chemistry. This lab studies the formation of the iron(III) salicylate complex ion, which is a more benign chemical system than the traditional iron(III) thiocyanate complex. A microtiter plate reader is used to reduce sample volumes, also giving students important experience using research-grade instrumentation. In addition, students gain more experience using adjustable manual micropipettors. Students responded positively to the lab, appreciating the green nature of the lab and the introduction of the plate reader, and student comments suggested that this lab successfully introduces green chemistry concepts to the general chemistry curriculum.