Nihal Zohud
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Nihal Zohud has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Abdel Naser Zaid
Department of Pharmacy, Faculty of Medicine and Health Sciences, An-Najah National University, P.O. Box 7, Nablus, Palestine
1 shared publication Aiman Qaddoumi
Department of Regulatory, Pharmacare PLC
1 shared publication- Bushra E'LAyan
Department of Pharmacy
1 shared publication Fatima Hussein
Department of Pharmacy
1 shared publication- Iyad Ali
Faculty of Medicine and Allied Medical Sciences, An-Najah National University, Nablus, Palestine
1 shared publication Mashhour Ghanem
Department of Regulatory, Pharmacare PLC
1 shared publication
Latest Publications
- Open Access
- 1 July 2020
- Published by Hindawi Limited in International Journal of Analytical Chemistry
- Vol. 2020, 1-9
RP-HPLC Method Development and Validation of Synthesized Codrug in Combination with Indomethacin, Paracetamol, and Famotidine
Background. Indomethacin is considered a potent nonsteroidal anti-inflammatory drug that could be combined with Paracetamol to have superior and synergist activity to manage pain and inflammation. To reduce the gastric side effect, they could be combined with Famotidine.Methodology. A codrug of Indomethacin and Paracetamol was synthesized and combined in solution with Famotidine. The quantification of the pharmaceutically active ingredients is pivotal in the development of pharmaceutical formulations. Therefore, a novel reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated according to the International Council for Harmonization (ICH) Q2R1 guidelines. A reverse phase C18 column with a mobile phase acetonitrile: sodium acetate buffer 60 : 40 at a flow rate of 1.4 mL/min and pH 5 was utilized.Results. The developed method showed good separation of the four tested drugs with a linear range of 0.01-0.1 mg/mL (R-2 > 0.99). The LODs for FAM, PAR, IND, and codrug were 3.076 x 10(-9), 3.868 x 10(-10), 1.066 x 10(-9), and 4.402 x 10(-9) mg/mL respectively. While the LOQs were 9.322 x 10(-9), 1.172 x 10(-10), 3.232 x 10(-9), and 1.334 x 10(-8) mg/mL, respectively. Furthermore, the method was precise, accurate, selective, and robust with values of relative standard deviation (RSD) less than 2%. Moreover, the developed method was applied to study thein vitrohydrolysis and conversion of codrug into Indomethacin and Paracetamol.Conclusion. The codrug of Indomethacin and Paracetamol was successfully synthesized for the first time. Moreover, the developed analytical method, to our knowledge, is the first of its kind to simultaneously quantify four solutions containing the following active ingredients of codrug, Indomethacin, Paracetamol, and Famotidine mixture with added pharmaceutical inactive ingredients in one HPLC run.
- 1 July 2020
- Published by Hindawi Limited in International Journal of Analytical Chemistry
- Vol. 2020, 1-9
Open AccessRP-HPLC Method Development and Validation of Synthesized Codrug in Combination with Indomethacin, Paracetamol, and Famotidine
Background. Indomethacin is considered a potent nonsteroidal anti-inflammatory drug that could be combined with Paracetamol to have superior and synergist activity to manage pain and inflammation. To reduce the gastric side effect, they could be combined with Famotidine.Methodology. A codrug of Indomethacin and Paracetamol was synthesized and combined in solution with Famotidine. The quantification of the pharmaceutically active ingredients is pivotal in the development of pharmaceutical formulations. Therefore, a novel reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated according to the International Council for Harmonization (ICH) Q2R1 guidelines. A reverse phase C18 column with a mobile phase acetonitrile: sodium acetate buffer 60 : 40 at a flow rate of 1.4 mL/min and pH 5 was utilized.Results. The developed method showed good separation of the four tested drugs with a linear range of 0.01-0.1 mg/mL (R-2 > 0.99). The LODs for FAM, PAR, IND, and codrug were 3.076 x 10(-9), 3.868 x 10(-10), 1.066 x 10(-9), and 4.402 x 10(-9) mg/mL respectively. While the LOQs were 9.322 x 10(-9), 1.172 x 10(-10), 3.232 x 10(-9), and 1.334 x 10(-8) mg/mL, respectively. Furthermore, the method was precise, accurate, selective, and robust with values of relative standard deviation (RSD) less than 2%. Moreover, the developed method was applied to study thein vitrohydrolysis and conversion of codrug into Indomethacin and Paracetamol.Conclusion. The codrug of Indomethacin and Paracetamol was successfully synthesized for the first time. Moreover, the developed analytical method, to our knowledge, is the first of its kind to simultaneously quantify four solutions containing the following active ingredients of codrug, Indomethacin, Paracetamol, and Famotidine mixture with added pharmaceutical inactive ingredients in one HPLC run.
- Open Access
- 1 November 2017
- Published by Taylor & Francis in Drug Design, Development and Therapy
- Vol. ume 11, 3291-3298
Pharmacodynamic testing and new validated HPLC method to assess the interchangeability between multi-source orlistat capsules
Background: Orlistat is an irreversible inhibitor of the lipase enzyme that prevents trigylcerides from being digested, thereby inhibiting triglyceride hydrolysis and absorption. The resultant reduced calorie uptake enables a positive effect on weight control. Systemic absorption of the drug is, therefore, not necessary for its mode of action. An alternative in vitro study (pharmacodynamic) has been introduced for this drug, as in vivo bioavailability studies are irrelevant with regard to the achievement of the product’s intended purposes. Objectives: To develop a new validated high-performance liquid chromatography (HPLC) method for the analysis of orlistat and to assess the potency and equivalence of three orlistat formulations using the pharmacodynamic method as a surrogate indicator of pharmaceutical interchangeability. Methods: A new HPLC method was developed for the analysis and for the dissolution studies of orlistat in capsules. Pancreatic lipase activity was measured for three different capsule products: Orlislim®, Slimcare®, and Xenical®, G1, G2, and the brand, respectively. Porcine pancreatic lipase and p-nitrophenyl butyrate (PNPB) were placed in a pH 7.4 reaction buffer at 37°C, and substrate hydrolysis was monitored by measuring absorbance changes at 410 nm; this was repeated on six capsules of each product. The inhibition was expressed by the concentration of product, which inhibited 50% of the activity of pancreatic lipase (IC50). Results: The new analytical method was suitable for orlistat analysis. Values of IC50 from regression lines and equations were 6.14, 8.43, and 7.80 µg/mL for Orlislim®, Xenical®, and Slimcare®, respectively. Conclusion: Pharmacodynamic studies of lipase inhibition could be used to support in vitro dissolution, which demonstrates interchangeability between generic and branded orlistat capsules. Moreover, it could be suggested as an alternative tool to bioequivalence studies for orlistat oral products.
- 1 November 2017
- Published by Taylor & Francis in Drug Design, Development and Therapy
- Vol. ume 11, 3291-3298
Open AccessPharmacodynamic testing and new validated HPLC method to assess the interchangeability between multi-source orlistat capsules
Background: Orlistat is an irreversible inhibitor of the lipase enzyme that prevents trigylcerides from being digested, thereby inhibiting triglyceride hydrolysis and absorption. The resultant reduced calorie uptake enables a positive effect on weight control. Systemic absorption of the drug is, therefore, not necessary for its mode of action. An alternative in vitro study (pharmacodynamic) has been introduced for this drug, as in vivo bioavailability studies are irrelevant with regard to the achievement of the product’s intended purposes. Objectives: To develop a new validated high-performance liquid chromatography (HPLC) method for the analysis of orlistat and to assess the potency and equivalence of three orlistat formulations using the pharmacodynamic method as a surrogate indicator of pharmaceutical interchangeability. Methods: A new HPLC method was developed for the analysis and for the dissolution studies of orlistat in capsules. Pancreatic lipase activity was measured for three different capsule products: Orlislim®, Slimcare®, and Xenical®, G1, G2, and the brand, respectively. Porcine pancreatic lipase and p-nitrophenyl butyrate (PNPB) were placed in a pH 7.4 reaction buffer at 37°C, and substrate hydrolysis was monitored by measuring absorbance changes at 410 nm; this was repeated on six capsules of each product. The inhibition was expressed by the concentration of product, which inhibited 50% of the activity of pancreatic lipase (IC50). Results: The new analytical method was suitable for orlistat analysis. Values of IC50 from regression lines and equations were 6.14, 8.43, and 7.80 µg/mL for Orlislim®, Xenical®, and Slimcare®, respectively. Conclusion: Pharmacodynamic studies of lipase inhibition could be used to support in vitro dissolution, which demonstrates interchangeability between generic and branded orlistat capsules. Moreover, it could be suggested as an alternative tool to bioequivalence studies for orlistat oral products.