Sara Fraga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sara Fraga has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Luiz Felipe Valandro
MSciD-PhD Post-Graduate Program in Oral Science, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
11 shared publications - Liliana Gressler May
Federal University of Santa Maria, Brazil
9 shared publications - Gabriel Kalil Rocha Pereira
Graduate Program in Dental Sciences Federal University of Santa Maria (UFSM) Santa Maria Rio Grande do Sul Brazil
8 shared publications - Cornelis Johannes Kleverlaan
Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, Noord-Holland, the Netherlands
5 shared publications - Cristiane Machado Mengatto
Division of Prosthodontics, Department of Conservative Dentistry, School of Dentistry, Federal University of Rio Grande Do Sul (UFRGS), Porto Alegre, Brazil
3 shared publications - Camila da Silva Rodrigues
MSciD and PhD Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Rio Grande do Sul State, Santa Maria, Brazil
2 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 36, e256632
Mechanical behavior of endocrown vs. post-and-crown: a systematic review and meta-regression analysis
This systematic review and meta-regression analysis compared the load-to-fracture of endodontically treated teeth restored with endocrown and post-and-crown restorations, identifying factors influencing their mechanical behavior. Literature search in PubMed/MEDLINE, Web of Science, Scopus, EMBASE, and LILACS included studies published until September 2025. The search strategy combined Medical Subject Headings and free-text keywords. Two independent researchers performed the study selection. The eligibility criteria considered in vitro studies that evaluated the load-to-fracture of endodontically treated teeth restored with endocrowns and had a control group consisting of teeth restored with post-and-crown. From 862 studies, 25 met the eligibility criteria. The final meta-regression model explained 86% of the within-group variance, showing no significant differences in the load-to-fracture between endocrowns and post-and-crown restorations (p>0.05). The type of teeth, ferrule presence, and restoration material did not significantly influence the outcomes, whereas luting material and load application angle were critical determinants of load-to-fracture performance. Resin composite significantly increased the load-to-fracture compared to conventional resin cement (p<0.05). Oblique forces during mechanical tests reduced the load-to-fracture values (p<0.05). In conclusion, similar load-to-fracture performance is expected between endocrown and post-and-crown restorations. Luting material and mechanical testing parameters influenced outcomes and may have contributed to heterogeneity in prior meta-analyses.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 36, e256632
Open AccessMechanical behavior of endocrown vs. post-and-crown: a systematic review and meta-regression analysis
This systematic review and meta-regression analysis compared the load-to-fracture of endodontically treated teeth restored with endocrown and post-and-crown restorations, identifying factors influencing their mechanical behavior. Literature search in PubMed/MEDLINE, Web of Science, Scopus, EMBASE, and LILACS included studies published until September 2025. The search strategy combined Medical Subject Headings and free-text keywords. Two independent researchers performed the study selection. The eligibility criteria considered in vitro studies that evaluated the load-to-fracture of endodontically treated teeth restored with endocrowns and had a control group consisting of teeth restored with post-and-crown. From 862 studies, 25 met the eligibility criteria. The final meta-regression model explained 86% of the within-group variance, showing no significant differences in the load-to-fracture between endocrowns and post-and-crown restorations (p>0.05). The type of teeth, ferrule presence, and restoration material did not significantly influence the outcomes, whereas luting material and load application angle were critical determinants of load-to-fracture performance. Resin composite significantly increased the load-to-fracture compared to conventional resin cement (p<0.05). Oblique forces during mechanical tests reduced the load-to-fracture values (p<0.05). In conclusion, similar load-to-fracture performance is expected between endocrown and post-and-crown restorations. Luting material and mechanical testing parameters influenced outcomes and may have contributed to heterogeneity in prior meta-analyses.
- 15 June 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (2) , 241.e1-241.e8
Fit and fatigue behavior of CAD-CAM lithium disilicate crowns
- 15 June 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (2) , 241.e1-241.e8
Fit and fatigue behavior of CAD-CAM lithium disilicate crowns
- 19 December 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 132 (5) , 1061-1065
Effects of disinfection with a vinegar-hydrogen peroxide mixture on the surface composition and topography of a cobalt-chromium alloy
- 19 December 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 132 (5) , 1061-1065
Effects of disinfection with a vinegar-hydrogen peroxide mixture on the surface composition and topography of a cobalt-chromium alloy
- 1 December 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 128 (6) , 1190-1200
Effect of milling, fitting adjustments, and hydrofluoric acid etching on the strength and roughness of CAD-CAM glass-ceramics: A systematic review and meta-analysis
- 1 December 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 128 (6) , 1190-1200
Effect of milling, fitting adjustments, and hydrofluoric acid etching on the strength and roughness of CAD-CAM glass-ceramics: A systematic review and meta-analysis
- 21 November 2022
- Published by Elsevier in Dental Materials
- Vol. 38 (12) , 2003-2013
Pigmentation techniques of a 4YSZ: Effect on the fatigue mechanical behavior of a 4YSZ adhesively luted onto dentin analog
- 21 November 2022
- Published by Elsevier in Dental Materials
- Vol. 38 (12) , 2003-2013
Pigmentation techniques of a 4YSZ: Effect on the fatigue mechanical behavior of a 4YSZ adhesively luted onto dentin analog
- 1 June 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 127 (6) , 929-935
Effect of a vinegar-hydrogen peroxide mixture on the surface properties of a cobalt-chromium alloy: A possible disinfectant for removable partial dentures
- 1 June 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 127 (6) , 929-935
Effect of a vinegar-hydrogen peroxide mixture on the surface properties of a cobalt-chromium alloy: A possible disinfectant for removable partial dentures
- 1 July 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (7) , 1096-1106
Extended glaze firings for porcelain-veneered zirconia: Effects on the mechanical and optical behavior
- 1 July 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (7) , 1096-1106
Extended glaze firings for porcelain-veneered zirconia: Effects on the mechanical and optical behavior
- Open Access
- 1 June 2021
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 32 (3) , 56-64
Influence of testing environment on static fatigue behavior of a glass and a polycrystalline ceramic
It aims on evaluate the effect of the test environment on static fatigue behavior of lithium disilicate-based (LD), and yttrium oxide-stabilized zirconia (YSZ) ceramics. Specimens of LD (IPS e.max CAD, Ivoclar Vivadent) and YSZ (IPS e.max ZirCAD MO, 3 mol% Y2O3, Ivoclar Vivadent) were randomly allocated into three groups: tested in air, inert (paraffin oil, Sigma Aldrich) or distilled water. The static fatigue test (n=15) was performed using a piston-on-three ball assembly, adapted from ISO 6872, as follows: starting load 100 N for LD and 300 N for YSZ; loading application time set to 1 hour for each loading step; step size of 50 N for LD and 100 N for YSZ, applied successively until fracture. Data from static fatigue strength (MPa) and time to fracture (hours) were recorded. Fractographic analysis was executed. Survival analysis corroborates absence of influence of environment on static fatigue outcomes (fatigue strength, time to fracture and survival rates) for YSZ. For LD, specimens tested in air presented statistically superior survival rate and static fatigue strength (p= 0.025). In regards of time to fracture, LD tested in air were superior than when tested in distilled water (p=0.019) or inert (p=0.017) environments. No statistical differences for Weibull modulus were observed. Failures started on the tensile stress surface. Thus, the test environment did not affect slow crack growth (SCG) mechanisms during static fatigue test of YSZ ceramics, but it plays a significant role for the static fatigue behavior of lithium disilicate-based glass ceramics, indicating a high susceptibility to SCG.
- 1 June 2021
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 32 (3) , 56-64
Open AccessInfluence of testing environment on static fatigue behavior of a glass and a polycrystalline ceramic
It aims on evaluate the effect of the test environment on static fatigue behavior of lithium disilicate-based (LD), and yttrium oxide-stabilized zirconia (YSZ) ceramics. Specimens of LD (IPS e.max CAD, Ivoclar Vivadent) and YSZ (IPS e.max ZirCAD MO, 3 mol% Y2O3, Ivoclar Vivadent) were randomly allocated into three groups: tested in air, inert (paraffin oil, Sigma Aldrich) or distilled water. The static fatigue test (n=15) was performed using a piston-on-three ball assembly, adapted from ISO 6872, as follows: starting load 100 N for LD and 300 N for YSZ; loading application time set to 1 hour for each loading step; step size of 50 N for LD and 100 N for YSZ, applied successively until fracture. Data from static fatigue strength (MPa) and time to fracture (hours) were recorded. Fractographic analysis was executed. Survival analysis corroborates absence of influence of environment on static fatigue outcomes (fatigue strength, time to fracture and survival rates) for YSZ. For LD, specimens tested in air presented statistically superior survival rate and static fatigue strength (p= 0.025). In regards of time to fracture, LD tested in air were superior than when tested in distilled water (p=0.019) or inert (p=0.017) environments. No statistical differences for Weibull modulus were observed. Failures started on the tensile stress surface. Thus, the test environment did not affect slow crack growth (SCG) mechanisms during static fatigue test of YSZ ceramics, but it plays a significant role for the static fatigue behavior of lithium disilicate-based glass ceramics, indicating a high susceptibility to SCG.