    Characterization of cryo-cooled silicon crystal monochromators via measurement of flux versus power

    by Lucia Alianelli, Hossein Khosroabadi, John Sutter, Andrew C. Walters, Pierpaolo Romano, Kalotina Geraki, Francesco Carlá, Jonathan Rawle, Sarah Barnett, Kawal Sawhney

    A study on the thermal load of cryogenically cooled silicon in synchrotron double-crystal monochromators is presented, based on experimental data from four different beamlines at Diamond Light Source. Different amounts of power are deposited on the first monochromator crystal by varying the storage ring current. The resulting crystal deformation causes a decline in the diffraction efficiency when power and power density are above threshold values. The results are compatible with an analytical model of thermo-mechanical deformation. Acceptable monochromator heat load values are determined with this model, to ensure optimal function of the monochromator. This model, previously tested against finite element analyses, is now validated against measured data and it will be used as a tool for initial analysis of monochromator performance on upgraded photon sources.

  • Open Access

    VMXm – A sub-micron focus macromolecular crystallography beamline at Diamond Light Source

    by Anna J. Warren, Jose Trincao, Adam D. Crawshaw, Emma V. Beale, Graham Duller, Andrew Stallwood, Mark Lunnon, Richard Littlewood, Adam Prescott, Andrew Foster, et al.

    VMXm joins the suite of operational macromolecular crystallography beamlines at Diamond Light Source. It has been designed to optimize rotation data collections from protein crystals less than 10 µm and down to below 1 µm in size. The beamline has a fully focused beam of 0.3 × 2.3 µm (vertical × horizontal) with a tuneable energy range (6–28 keV) and high flux (1.6 × 1012 photons s−1 at 12.5 keV). The crystals are housed within a vacuum chamber to minimize background scatter from air. Crystals are plunge-cooled on cryo-electron microscopy grids, allowing much of the liquid surrounding the crystals to be removed. These factors improve the signal-to-noise during data collection and the lifetime of the microcrystals can be prolonged by exploiting photoelectron escape. A novel in vacuo sample environment has been designed which also houses a scanning electron microscope to aid with sample visualization. This combination of features at VMXm allows measurements at the physical limits of X-ray crystallography on biomacromolecules to be explored and exploited.


  • Open Access

    Calculating temperature-dependent X-ray structure factors of α-quartz with an extensible Python 3 package

    by John P. Sutter, James Pittard, Jacob Filik, Alfred Q. R. Baron

    The design of X-ray optics based on diffraction from crystals depends on the accurate calculation of the structure factors of their Bragg reflections over a wide range of temperatures. In general, the temperature dependence of the lattice parameters, the atomic positions and the atomic thermal vibrations is both anisotropic and nonlinear. Implemented here is a software package for precise and flexible calculation of structure factors for dynamical diffraction. α-Quartz is used as an example because it presents the challenges mentioned above and because it is being considered for use in high-resolution X-ray spectroscopy. The package is designed to be extended easily to other crystals by adding new material files, which are kept separate from the package's stable core. Python 3 was chosen as the language to allow the easy integration of this code into existing packages. The importance of a correct anisotropic treatment of the atomic thermal vibrations is demonstrated by comparison with an isotropic Debye model. Discrepancies between the two models can be as much as 5% for strong reflections and considerably larger (even to the level of 100%) for weak reflections. A script for finding Bragg reflections that backscatter X-rays of a given energy within a given temperature range is demonstrated. The package and example scripts are available on request. Also discussed, in detail, are the various conventions related to the proper description of chiral quartz.


  • Open Access

    Beamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source

    by Christina Reinhard, Michael Drakopoulos, Sharif I. Ahmed, Hans Deyhle, Andrew James, Christopher M. Charlesworth, Martin Burt, John Sutter, Steven Alexander, Peter Garland, et al.

    The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.


  • Open Access

    Extending synchrotron SAXS instrument ranges through addition of a portable, inexpensive USAXS module with vertical rotation axes

    by Brian R. Pauw, Andrew J. Smith, Tim Snow, Olga Shebanova, John P. Sutter, Jan Ilavsky, Daniel Hermida-Merino, Glen J. Smales, Nicholas J. Terrill, Andreas F. Thünemann, et al.

    Ultra-SAXS can enhance the capabilities of existing synchrotron SAXS/WAXS beamlines. A compact ultra-SAXS module has been developed, which extends the measurable q-range with 0.0015 ≤ q (nm−1) ≤ 0.2, allowing structural dimensions in the range 30 ≤ D (nm) ≤ 4000 to be probed in addition to the range covered by a high-end SAXS/WAXS instrument. By shifting the module components in and out on their respective motor stages, SAXS/WAXS measurements can be easily and rapidly interleaved with USAXS measurements. The use of vertical crystal rotation axes (horizontal diffraction) greatly simplifies the construction, at minimal cost to efficiency. In this paper, the design considerations, realization and synchrotron findings are presented. Measurements of silica spheres, an alumina membrane, and a porous carbon catalyst are provided as application examples.


  • Open Access

    I22: SAXS/WAXS beamline at Diamond Light Source – an overview of 10 years operation

    by A. J. Smith, S. G. Alcock, L. S. Davidson, J. H. Emmins, J. C. Hiller Bardsley, P. Holloway, M. Malfois, A. R. Marshall, C. L. Pizzey, S. E. Rogers, et al.

    Beamline I22 at Diamond Light Source is dedicated to the study of soft-matter systems from both biological and materials science. The beamline can operate in the range 3.7 keV to 22 keV for transmission SAXS and 14 keV to 20 keV for microfocus SAXS with beam sizes of 240 µm × 60 µm [full width half-maximum (FWHM) horizontal (H) × vertical (V)] at the sample for the main beamline, and approximately 10 µm × 10 µm for the dedicated microfocusing platform. There is a versatile sample platform for accommodating a range of facilities and user-developed sample environments. The high brilliance of the insertion device source on I22 allows structural investigation of materials under extreme environments (for example, fluid flow at high pressures and temperatures). I22 provides reliable access to millisecond data acquisition timescales, essential to understanding kinetic processes such as protein folding or structural evolution in polymers and colloids.


  • Open Access

    Fast convolution-based performance estimation method for diffraction-limited source with imperfect X-ray optics

    by Lingfei Hu, John P. Sutter, Hongchang Wang

    Although optical element error analysis is always an important part of beamline design for highly coherent synchrotron radiation or free-electron laser sources, the usual wave optics simulation can be very time-consuming, which limits its application at the early stage of the beamline design. In this work, a new theoretical approach has been proposed for quick evaluations of the optical performance degradation due to optical element error. In this way, time-consuming detailed simulations can be applied only when truly necessary. This approach treats the imperfections as perturbations that convolve with the ideal performance. For simplicity, but not by necessity, the Gaussian Schell-model has been used to show the application of this theoretical approach. The influences of the finite aperture size and height error of a focusing mirror are analysed using the proposed theory. The physical explanation of the performance degradation acquired from the presented approach helps to give a better definition of the critical range of error spatial frequencies that most affect the performance of a mirror. An example comparing two mirror surface errors with identical power spectral density functions is given. These two types of mirror surface errors result in very different intensity profiles. The approach presented in this work could help beamline designers specify the error tolerances on general optical elements more accurately.


  • Top Cited Papers
    Open Access

    Beamline B21: high-throughput small-angle X-ray scattering at Diamond Light Source

    by Nathan P. Cowieson, Charlotte J. C. Edwards-Gayle, Katsuaki Inoue, Nikul S. Khunti, James Doutch, Eugene Williams, Steven Daniels, Geoff Preece, Nicholas A. Krumpa, John P. Sutter, et al.

    B21 is a small-angle X-ray scattering (SAXS) beamline with a bending magnet source in the 3 GeV storage ring at the Diamond Light Source Ltd synchrotron in the UK. The beamline utilizes a double multi-layer monochromator and a toroidal focusing optic to deliver 2 × 1012 photons per second to a 34 × 40 µm (FWHM) focal spot at the in-vacuum Eiger 4M (Dectris) detector. A high-performance liquid chromatography system and a liquid-handling robot make it possible to load solution samples into a temperature-controlled in-vacuum sample cell with a high level of automation. Alternatively, a range of viscous or solid materials may be loaded manually using a range of custom sample cells. A default scattering vector range from 0.0026 to 0.34 Å−1 and low instrument background make B21 convenient for measuring a wide range of biological macromolecules. The beamline has run a full user programme since 2013.


  • Application of interference fits on cylindrical monochromator crystals to overcome clamping and cooling deformations

    by Joshua Stimson, Michael Ward, John Sutter, Sofia Diaz-Moreno, Simon Alcock, Peter Docker

    In order to provide adequate cryogenic cooling of both existing and next-generation crystal monochromators, a new approach to produce an optimum thermal interface between the first crystal and its copper heat exchanger is proposed. This will ensure that the increased heat load deposited by higher X-ray powers can be properly dissipated. Utilizing a cylindrical silicon crystal, a tubular copper heat exchanger and by exploiting the differing thermal and mechanical properties of the two, a very good thermal interface was achieved at liquid-nitrogen temperatures. The surface flatness of the diffracting plane at one end of the cylindrical crystal was measured at room temperature while unconstrained. The crystal was then placed into the copper heat exchanger, a slide fit at room temperature, and then cooled to liquid-nitrogen temperature. At −200°C the slide fit became an interference fit. This room-temperature `loose' fit was modelled using finite-element analysis to obtain the desired fit at cryogenic temperatures by prescribing the fit at room temperature. Under these conditions, the diffraction surface was measured for distortion due to thermal and mechanical clamping forces. The total deformation was measured to be 30 nm, an order of magnitude improvement over deformation caused by cooling alone with the original side-clamped design this concept method is set to replace. This new methodology also has the advantage that it is repeatable and does not require macro-scale tools to acquire a nanometre-accuracy mounting.