José Antonio Ferrer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
José Antonio Ferrer has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Silvia Soutullo
Unidad de Eficiencia Energética en la Edificación, CIEMAT, 28040 Madrid, Spain
6 shared publications - Emanuela Giancola
CIEMAT
4 shared publications - Maria del Rosario Heras
CIEMAT, Dept Energy, Energy Efficiency Bldg Unit, E-28040 Madrid, Spain
4 shared publications - Maria Nuria Sánchez
Renewable Energy Division, CIEMAT, 28040 Madrid, Spain
3 shared publications - Maria Jose Jimenez
Energy Efficiency in Buildings R&D Unit, CIEMAT, 28040 Madrid, Spain
2 shared publications - Ana Rosa Gamarra
CIEMAT
1 shared publication
Latest Publications
- Open Access
- 1 December 2024
- Published by Universidad Politecnica de Madrid - University Library in Anales de Edificación
- Vol. 10 (3) , 35-42
Energy efficiency in municipal buildings in Argentina for the Euroclima+ program
Within the framework of the Euroclima+ program, energy audits were conducted in municipal buildings in Argentina.The buildings were studied using information provided by the municipalities and information collected by the auditors. A program was then developed to obtain energy demand results based on the methodology of the national IRAM regulations. Based on this, it was found that the buildings do not meet adequate hygrothermal comfort conditions despite consuming a lot of energy. The proposed improvements achieve a reduction in energy demand of at least 40%.
- 1 December 2024
- Published by Universidad Politecnica de Madrid - University Library in Anales de Edificación
- Vol. 10 (3) , 35-42
Open AccessEnergy efficiency in municipal buildings in Argentina for the Euroclima+ program
Within the framework of the Euroclima+ program, energy audits were conducted in municipal buildings in Argentina.The buildings were studied using information provided by the municipalities and information collected by the auditors. A program was then developed to obtain energy demand results based on the methodology of the national IRAM regulations. Based on this, it was found that the buildings do not meet adequate hygrothermal comfort conditions despite consuming a lot of energy. The proposed improvements achieve a reduction in energy demand of at least 40%.
- Open Access
Suitability Evaluation of Different Measured Variables to Assess the Occupancy Patterns of a Building: Analysis of a Classroom of a School in Madrid during the COVID-19 Pandemic
Building occupancy is one of the relevant variables to understand the energy performance of buildings and to reduce the current gap between simulation-based and actual energy performance. In this study, the occupancy of a classroom in an educational center monitored over a full year was experimentally assessed. The classroom had different occupancy levels during the school year, with a theoretical minimum of eleven students, and no occupancy during vacations and weekends. Different variables such as indoor air temperature, relative humidity, CO2 concentration, overall electrical energy consumption of the educational center, electrical energy consumption of the building in which the monitored classroom is located, and heating energy consumption were recorded. We analyzed which of these variables were possible indicators of classroom occupancy, using the school timetable as a theoretical reference value for the validation of the results. Based on previous studies, one-hour moving averages are used to better identify the occupancy patterns by smoothing the fluctuations that are not a consequence of a change in the classroom occupancy. Histograms of each variable are used to identify the variable ranges associated within the occupancy: occupied or empty. The concentration of CO2 and electric measurements, identified in previous works as suitable to assess the occupancy patterns of rooms like offices with lower levels of occupancy, are recognized as potential occupancy indicators. It is therefore concluded that a higher level of space occupancy does not affect the result, and the same variables are identified as potential occupancy indicators.
Open AccessSuitability Evaluation of Different Measured Variables to Assess the Occupancy Patterns of a Building: Analysis of a Classroom of a School in Madrid during the COVID-19 Pandemic
Building occupancy is one of the relevant variables to understand the energy performance of buildings and to reduce the current gap between simulation-based and actual energy performance. In this study, the occupancy of a classroom in an educational center monitored over a full year was experimentally assessed. The classroom had different occupancy levels during the school year, with a theoretical minimum of eleven students, and no occupancy during vacations and weekends. Different variables such as indoor air temperature, relative humidity, CO2 concentration, overall electrical energy consumption of the educational center, electrical energy consumption of the building in which the monitored classroom is located, and heating energy consumption were recorded. We analyzed which of these variables were possible indicators of classroom occupancy, using the school timetable as a theoretical reference value for the validation of the results. Based on previous studies, one-hour moving averages are used to better identify the occupancy patterns by smoothing the fluctuations that are not a consequence of a change in the classroom occupancy. Histograms of each variable are used to identify the variable ranges associated within the occupancy: occupied or empty. The concentration of CO2 and electric measurements, identified in previous works as suitable to assess the occupancy patterns of rooms like offices with lower levels of occupancy, are recognized as potential occupancy indicators. It is therefore concluded that a higher level of space occupancy does not affect the result, and the same variables are identified as potential occupancy indicators.
- Open Access
Methodology for Quantifying the Energy Saving Potentials Combining Building Retrofitting, Solar Thermal Energy and Geothermal Resources
New technological, societal and legislative developments are necessary to support transitions to low-carbon energy systems. The building sector is responsible for almost 36% of the global final energy and 40% of CO2 emissions, so this sector has high potential to contribute to the expansion of positive energy districts. With this aim, a new digital Geographic Information System (GIS) platform has been developed to quantify the energy savings obtained through the implementation of refurbishment measures in residential buildings, including solar thermal collectors and geothermal technologies and assuming the postal district as the representative unit for the territory. Solar resources have been estimated from recently updated solar irradiation maps, whereas geothermal resources have been estimated from geological maps. Urbanistic data have been estimated from official cadastre databases. For representative buildings, the annual energy demand and savings are obtained and compared with reference buildings, both for heating and cooling. The GIS platform provides information on average results for each postal district, as well as estimates for buildings with particular parameters. The methodology has been applied to the Asturian region, an area of about 10,600 km2 on the Cantabrian coast of Spain, with complex orography and scattered population, qualified as a region in energy transition. High rehabilitation potentials have been achieved for buildings constructed before the implementation of the Spanish Technical Building Code of 2006, being higher for isolated houses than for collective buildings. Some examples of results are introduced in specific localities of different climatic zones.
Open AccessMethodology for Quantifying the Energy Saving Potentials Combining Building Retrofitting, Solar Thermal Energy and Geothermal Resources
New technological, societal and legislative developments are necessary to support transitions to low-carbon energy systems. The building sector is responsible for almost 36% of the global final energy and 40% of CO2 emissions, so this sector has high potential to contribute to the expansion of positive energy districts. With this aim, a new digital Geographic Information System (GIS) platform has been developed to quantify the energy savings obtained through the implementation of refurbishment measures in residential buildings, including solar thermal collectors and geothermal technologies and assuming the postal district as the representative unit for the territory. Solar resources have been estimated from recently updated solar irradiation maps, whereas geothermal resources have been estimated from geological maps. Urbanistic data have been estimated from official cadastre databases. For representative buildings, the annual energy demand and savings are obtained and compared with reference buildings, both for heating and cooling. The GIS platform provides information on average results for each postal district, as well as estimates for buildings with particular parameters. The methodology has been applied to the Asturian region, an area of about 10,600 km2 on the Cantabrian coast of Spain, with complex orography and scattered population, qualified as a region in energy transition. High rehabilitation potentials have been achieved for buildings constructed before the implementation of the Spanish Technical Building Code of 2006, being higher for isolated houses than for collective buildings. Some examples of results are introduced in specific localities of different climatic zones.
- Open Access
Testing Platforms as Drivers for Positive-Energy Living Laboratories
The development of city-driven urban laboratories was considered a priority by the European Commission through Action 3.2 of the Strategic Energy Technology Plan. In this context, positive-energy districts laboratories could take the role of urban drivers toward innovation and sustainability in cities. These urban labs can provide real-life facilities with innovative co-creation processes and, at the same time, provide testing, experimenting, and prototyping of innovative technologies. In this scope, the authors of this work want to share the very first results of an empirical study using the testing facilities provided by the members of the Joint Program on Smart Cities of the European Energy Research Alliance as positive-energy districts laboratories. Six climatic regions are studied as boundary conditions, covering temperate and continental climates. Four scales of action are analyzed: Building, campus, urban, and virtual, with building and campus scales being the most frequent. Most of these laboratories focus on energy applications followed by networks, storage systems, and energy loads characterization. Many of these laboratories are regulated by ICT technologies but few of them consider social aspects, lighting, waste, and water systems. A SWOT analysis is performed to highlight the critical points of the testing facilities in order to replicate optimized configurations under other conditions. This statistical study provides guidelines on integration, localization, functionality, and technology modularity aspects. The use of these guidelines will ensure optimal replications, as well as identify possibilities and opportunities to share testing facilities of/between the positive-energy district laboratories.
Open AccessTesting Platforms as Drivers for Positive-Energy Living Laboratories
The development of city-driven urban laboratories was considered a priority by the European Commission through Action 3.2 of the Strategic Energy Technology Plan. In this context, positive-energy districts laboratories could take the role of urban drivers toward innovation and sustainability in cities. These urban labs can provide real-life facilities with innovative co-creation processes and, at the same time, provide testing, experimenting, and prototyping of innovative technologies. In this scope, the authors of this work want to share the very first results of an empirical study using the testing facilities provided by the members of the Joint Program on Smart Cities of the European Energy Research Alliance as positive-energy districts laboratories. Six climatic regions are studied as boundary conditions, covering temperate and continental climates. Four scales of action are analyzed: Building, campus, urban, and virtual, with building and campus scales being the most frequent. Most of these laboratories focus on energy applications followed by networks, storage systems, and energy loads characterization. Many of these laboratories are regulated by ICT technologies but few of them consider social aspects, lighting, waste, and water systems. A SWOT analysis is performed to highlight the critical points of the testing facilities in order to replicate optimized configurations under other conditions. This statistical study provides guidelines on integration, localization, functionality, and technology modularity aspects. The use of these guidelines will ensure optimal replications, as well as identify possibilities and opportunities to share testing facilities of/between the positive-energy district laboratories.
- Open Access
How Climate Trends Impact on the Thermal Performance of a Typical Residential Building in Madrid
Based on the European energy directives, the building sector has to provide comfortable levels for occupants with minimum energy consumption as well as to reduce greenhouse gas emissions. This paper aims to compare the impact of climate change on the energy performance of residential buildings in order to derive potential design strategies. Different climate file inputs of Madrid have been used to quantify comparatively the thermal needs of two reference residential buildings located in this city. One of them represents buildings older than 40 years built according to the applicable Spanish regulations prior to 1979. The other refers to buildings erected in the last decade under more energy-restrictive constructive regulations. Three different climate databases of Madrid have been used to assess the impact of the evolution of the climate in recent years on the thermal demands of these two reference buildings. Two of them are typical meteorological years (TMY) derived from weather data measured before 2000. On the contrary, the third one is an experimental file representing the average values of the meteorological variables registered in Madrid during the last decade. Annual and monthly comparisons are done between the three climate databases assessing the climate changes. Compared to the TMYs databases, the experimental one records an average air temperature of 1.8 °C higher and an average value of relative humidity that is 9% lower.
Open AccessHow Climate Trends Impact on the Thermal Performance of a Typical Residential Building in Madrid
Based on the European energy directives, the building sector has to provide comfortable levels for occupants with minimum energy consumption as well as to reduce greenhouse gas emissions. This paper aims to compare the impact of climate change on the energy performance of residential buildings in order to derive potential design strategies. Different climate file inputs of Madrid have been used to quantify comparatively the thermal needs of two reference residential buildings located in this city. One of them represents buildings older than 40 years built according to the applicable Spanish regulations prior to 1979. The other refers to buildings erected in the last decade under more energy-restrictive constructive regulations. Three different climate databases of Madrid have been used to assess the impact of the evolution of the climate in recent years on the thermal demands of these two reference buildings. Two of them are typical meteorological years (TMY) derived from weather data measured before 2000. On the contrary, the third one is an experimental file representing the average values of the meteorological variables registered in Madrid during the last decade. Annual and monthly comparisons are done between the three climate databases assessing the climate changes. Compared to the TMYs databases, the experimental one records an average air temperature of 1.8 °C higher and an average value of relative humidity that is 9% lower.
- Open Access
- 1 September 2017
- Published by Elsevier in Energy Procedia
- Vol. 122, 817-822
New simulation platform for the rehabilitation of residential buildings in Madrid
- 1 September 2017
- Published by Elsevier in Energy Procedia
- Vol. 122, 817-822
Open AccessNew simulation platform for the rehabilitation of residential buildings in Madrid
- 1 July 2016
- Published by Elsevier in Energy and Buildings
- Vol. 124, 7-18
Energy performance assessment of a polygeneration plant in different weather conditions through simulation tools
- 1 July 2016
- Published by Elsevier in Energy and Buildings
- Vol. 124, 7-18
Energy performance assessment of a polygeneration plant in different weather conditions through simulation tools
- 1 November 2015
- Published by Elsevier in Energy and Buildings
- Vol. 107, 37-48
Modelling and experimental analysis of three radioconvective panels for night cooling
- 1 November 2015
- Published by Elsevier in Energy and Buildings
- Vol. 107, 37-48
Modelling and experimental analysis of three radioconvective panels for night cooling
- 1 January 2015
- Published by Elsevier in Energy and Buildings
- Vol. 87, 272-281
Energetic experimental evaluation of the active systems of the RDB building 70 of the SSP-ARFRISOL
- 1 January 2015
- Published by Elsevier in Energy and Buildings
- Vol. 87, 272-281
Energetic experimental evaluation of the active systems of the RDB building 70 of the SSP-ARFRISOL