Nahikari González
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nahikari González has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Abel Fontsere
CELLS-ALBA, Carrer de la Llum 2-26, Cerdanyola del Valles, Barcelona 08290, Spain
2 shared publicationsCarles Colldelram
ALBA Synchrotron, Carrer de la llum 2-26, 08290 Cerdanyola del Vallès, Catalonia, Spain
2 shared publicationsClaude Ruget
ALBA Synchrotron Light Source, Cerdanyola del Vallés, Spain
2 shared publications- Eric Pellegrin
ALBA Synchrotron Light Source, E-08290 Cerdanyola del Vallès, Barcelona, Spain
2 shared publications Jordi Prat
CELLS-ALBA, Carrer de la Llum 2-26, Cerdanyola del Valles, Barcelona 08290, Spain
2 shared publicationsJosep Nicolas
ALBA Synchrotron, Carrer de la llum 2-26, 08290 Cerdanyola del Vallès, Catalonia, Spain
2 shared publications
Latest Publications
- 6 May 2022
- Published by Taylor & Francis in Synchrotron Radiation News
- p. 1-6
A Versatile Adaptive Optics System for Alba Beamlines
The development of X-ray photon science has been characterized in the last few years by the development of free electron lasers and the so-called diffraction limited storage rings. These new source...
- 6 May 2022
- Published by Taylor & Francis in Synchrotron Radiation News
- p. 1-6
A Versatile Adaptive Optics System for Alba Beamlines
The development of X-ray photon science has been characterized in the last few years by the development of free electron lasers and the so-called diffraction limited storage rings. These new source...
- 6 December 2019
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 300, 112258
Water/methanol solutions characterized by liquid μ-jet XPS and DFT—The methanol hydration case
- 6 December 2019
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 300, 112258
Water/methanol solutions characterized by liquid μ-jet XPS and DFT—The methanol hydration case
- 16 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2054 (1) , 060013
Adaptive optics bender with sub-nanometer correction and stability
We present an adaptive mirror system capable of controlling the figure of the mirror surface with resolution and stability below one nanometer, and in operation conditions. This allows correcting wavefront deformations caused by static or dynamic sources, like thermal bump on optics, gravity sag, or clamping effects, to the level of the highest quality figure errors. The bender system includes the usual torque actuators at the ends of the mirror as well as a number of force correctors along the mirror length, which introduce the desired deformation of the mirror substrate. The deformation of the substrate is stabilized using different strategies: for the bending actuators, load cells are used to provide feedback of the applied force. For the corrector actuators, which require a considerably lower force, the system is stabilized by combining springs and magnets to apply a force with independence of mechanical drifts of the mirror.
- 16 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2054 (1) , 060013
Adaptive optics bender with sub-nanometer correction and stability
We present an adaptive mirror system capable of controlling the figure of the mirror surface with resolution and stability below one nanometer, and in operation conditions. This allows correcting wavefront deformations caused by static or dynamic sources, like thermal bump on optics, gravity sag, or clamping effects, to the level of the highest quality figure errors. The bender system includes the usual torque actuators at the ends of the mirror as well as a number of force correctors along the mirror length, which introduce the desired deformation of the mirror substrate. The deformation of the substrate is stabilized using different strategies: for the bending actuators, load cells are used to provide feedback of the applied force. For the corrector actuators, which require a considerably lower force, the system is stabilized by combining springs and magnets to apply a force with independence of mechanical drifts of the mirror.
- 16 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2054 (1) , 060032
Optical design of the new microfocus beamline BL06-XAIRA at ALBA
ALBA is a third generation 3-GeV synchrotron radiation facility built near Barcelona servicing worldwide academic and industrial users since 2012. It currently hosts eight operating beamlines, including one dedicated to Macromolecular Crystallography (MX), BL13-XALOC. Current expansion plans of the facility include a specific microfocus MX beamline, BL06-XAIRA, now in design stage, which will complement the existing BL13-XALOC MX beamline. The aim of XAIRA is to provide a stable, high-flux beam of 1×1 μmm2 FWHM (3×1 μmm2 full beam) at 1 Å photon wavelength and reach ∼4 keV in the low limit of the energy range. Here we present the current plans for the photon source and the optical design of the XAIRA beamline, as well as the some preliminary ideas on the end station.
- 16 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2054 (1) , 060032
Optical design of the new microfocus beamline BL06-XAIRA at ALBA
ALBA is a third generation 3-GeV synchrotron radiation facility built near Barcelona servicing worldwide academic and industrial users since 2012. It currently hosts eight operating beamlines, including one dedicated to Macromolecular Crystallography (MX), BL13-XALOC. Current expansion plans of the facility include a specific microfocus MX beamline, BL06-XAIRA, now in design stage, which will complement the existing BL13-XALOC MX beamline. The aim of XAIRA is to provide a stable, high-flux beam of 1×1 μmm2 FWHM (3×1 μmm2 full beam) at 1 Å photon wavelength and reach ∼4 keV in the low limit of the energy range. Here we present the current plans for the photon source and the optical design of the XAIRA beamline, as well as the some preliminary ideas on the end station.
- 1 December 2016
- Published by Elsevier in Ultramicroscopy
- Vol. 171, 63-69
Custom sample environments at the ALBA XPEEM
- 1 December 2016
- Published by Elsevier in Ultramicroscopy
- Vol. 171, 63-69
Custom sample environments at the ALBA XPEEM
- 5 August 2014
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations and Advances
- Vol. 70 (a1) , C1744
New developments and operation of the MX beamline XALOC at ALBA synchrotron
BL13-XALOC is a Macromolecular Crystallography beamline at the 3-GeV ALBA synchrotron near Barcelona, and is operating with users since 2012. Currently being the only MX beamline at the site, XALOC has been designed to deal not only with easily automatable x-ray diffraction experiments of medium-sized crystals, but also with more complex ones that include a variety of crystal sizes and unit-cell length dimensions, crystals with high mosaic spread, and/or poorly diffracting crystals. The aim for a reliable all-in-one beamline contrasts with the trend observed lately, i.e. MX beamlines target specific characteristics of the crystals (microcrystals, large unit cells), techniques (tunability, small or large wavelengths), or to the status of the MX projects (crystal screening). The flexibility of the beamline is achieved by providing a very stable photon beam in an enery range of 5-22 keV and by changing the beam size at the sample position without loosing flux through defocusing to accomodate the dimensions of the beam to those of the sample. The beam dimensions at the sample position range from 57×5.5 µm2 FWHM (H×V) when focused to ~300×300 µm2. The dimensions of the beam are changed without varying the beam path. The beamline optics that allows this flexibility is based on an in-vacuum undulator, a Si(111) channel-cut monochromator, and a pair of KB mirrors. The defocused beam is severely affected by the slope errors of the mirrors, which produce striations on the beam profile at the sample position, mainly in the vertical direction. To minimize these striations, we have developed a new method that corrects mirror profiles by using spring actuators. The process resulted in a 4-fold reduction of the mirror slope errors, and in striations of the beam that amount only for ~10% of the nominal defocused beam profile. We expect that this uniform, tailored beam will improve the estimation of the radiation dose onto the sample, and will help in establishing a better data collection strategy. The end station includes a high accuracy single-axis diffractometer, a removable mini-kappa stage, an automated sample mounting robot, and a Pilatus6M, photon-counting detector. A new TANGO-based beamline control system (Sardana) has also been developed. Statistics of usage of the beamline and some relevant examples will be given.
- 5 August 2014
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations and Advances
- Vol. 70 (a1) , C1744
New developments and operation of the MX beamline XALOC at ALBA synchrotron
BL13-XALOC is a Macromolecular Crystallography beamline at the 3-GeV ALBA synchrotron near Barcelona, and is operating with users since 2012. Currently being the only MX beamline at the site, XALOC has been designed to deal not only with easily automatable x-ray diffraction experiments of medium-sized crystals, but also with more complex ones that include a variety of crystal sizes and unit-cell length dimensions, crystals with high mosaic spread, and/or poorly diffracting crystals. The aim for a reliable all-in-one beamline contrasts with the trend observed lately, i.e. MX beamlines target specific characteristics of the crystals (microcrystals, large unit cells), techniques (tunability, small or large wavelengths), or to the status of the MX projects (crystal screening). The flexibility of the beamline is achieved by providing a very stable photon beam in an enery range of 5-22 keV and by changing the beam size at the sample position without loosing flux through defocusing to accomodate the dimensions of the beam to those of the sample. The beam dimensions at the sample position range from 57×5.5 µm2 FWHM (H×V) when focused to ~300×300 µm2. The dimensions of the beam are changed without varying the beam path. The beamline optics that allows this flexibility is based on an in-vacuum undulator, a Si(111) channel-cut monochromator, and a pair of KB mirrors. The defocused beam is severely affected by the slope errors of the mirrors, which produce striations on the beam profile at the sample position, mainly in the vertical direction. To minimize these striations, we have developed a new method that corrects mirror profiles by using spring actuators. The process resulted in a 4-fold reduction of the mirror slope errors, and in striations of the beam that amount only for ~10% of the nominal defocused beam profile. We expect that this uniform, tailored beam will improve the estimation of the radiation dose onto the sample, and will help in establishing a better data collection strategy. The end station includes a high accuracy single-axis diffractometer, a removable mini-kappa stage, an automated sample mounting robot, and a Pilatus6M, photon-counting detector. A new TANGO-based beamline control system (Sardana) has also been developed. Statistics of usage of the beamline and some relevant examples will be given.