G. I. Greisukh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
G. I. Greisukh has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Dmitry A. Bykov
Samara National Research University
1 shared publication E. G. Ezhov
Penza State University of Architecture and Civil Engineering
1 shared publication- Evgeni A. Bezus
Image Processing Systems Institute, NRC “Kurchatov Institute”, Samara, Russia
1 shared publication - Grigoriy I. Greisukh
Samara State Aerospace University
1 shared publication S. A. Stepanov
Penza State University of Architecture and Civil Engineering
1 shared publication
Latest Publications
- 1 April 2009
- Published by Pleiades Publishing Ltd in Optics and Spectroscopy
- Vol. 106 (4) , 621-626
Suppression of the spectral selectivity of two-layer phase-relief diffraction structures
The method and results of studying the effect of relief depth on the attainable degree of reducing the spectral selectivity of two-layer diffraction structures based on plastics and glass. The...
- 1 April 2009
- Published by Pleiades Publishing Ltd in Optics and Spectroscopy
- Vol. 106 (4) , 621-626
Suppression of the spectral selectivity of two-layer phase-relief diffraction structures
The method and results of studying the effect of relief depth on the attainable degree of reducing the spectral selectivity of two-layer diffraction structures based on plastics and glass. The...
- 1 February 2007
- Published by Allerton Press in Optoelectronics, Instrumentation and Data Processing
- Vol. 43 (1) , 70-75
Apochromatic correction of the rigid GRIN endoscope
A technique for apochromatic correction of rigid endoscope’s visual channel with an objective and a gradient-index relay is described. The technique consists in incorporating a corrector with a diffractive lens and one or two homogeneous refractive lenses. It is shown that the three-lens corrector can substantially reduce monochromatic aberrations of the system.
- 1 February 2007
- Published by Allerton Press in Optoelectronics, Instrumentation and Data Processing
- Vol. 43 (1) , 70-75
Apochromatic correction of the rigid GRIN endoscope
A technique for apochromatic correction of rigid endoscope’s visual channel with an objective and a gradient-index relay is described. The technique consists in incorporating a corrector with a diffractive lens and one or two homogeneous refractive lenses. It is shown that the three-lens corrector can substantially reduce monochromatic aberrations of the system.