Bryan R. Schlink
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bryan R. Schlink has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Perry Ferris
University of Florida
4 shared publications - Andrew D. Nordin
Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
3 shared publications - Collin Dunlap
Battelle Memorial Institute
3 shared publications - David A. Friedenberg
Battelle Memorial Institute
3 shared publications - Eric C. Meyers
Department of Bioengineering, Erik Jonsson School of Engineering and Computer Science (S.A.H., E.C.M.), University of Texas at Dallas, Richardson
3 shared publications - Lauren Wengerd
The Ohio State University, Columbus, USA
3 shared publications
Latest Publications
- Open Access
Leveraging neural drive to assess hand motor function in individuals with chronic stroke
Background Stroke is a leading cause of disability, with up to 80% of survivors experiencing motor impairments. These impairments are attributed to various factors, including reduced neural drive and altered motor unit firing patterns. Rehabilitation aims to restore motor function by enhancing motor unit recruitment and synchronization. High-density electromyography (HD-EMG) is a valuable tool for evaluating these changes in motor unit activity. Methods We tested a HD-EMG wearable forearm sleeve to investigate the relationship between motor function and motor unit properties including firing rate, motor unit module activation, and coherence. Seven individuals with chronic stroke and seven able-bodied individuals attempted 12 controlled hand and wrist movements while EMG was recorded. Motor units were decomposed across all movements using convolutive blind source separation. Results Fewer motor units were detectable in individuals with stroke compared to able-bodied participants. There was a significant reduction in motor unit firing rate during specific movements such as wrist flexion and hand open. Motor unit coupling and activation were altered following stroke, with reduced module activation in 8 of the 12 movements attempted. Furthermore, a reduction in coherence for gross movements and an increase in coherence for more dexterous thumb movements suggest altered neural drive to motor units after stroke that is differentially tuned to the complexity of movement. A combined neural control signature, consisting of multiple motor unit features, demonstrated strong correlation ( R 2 =0.81 ) with clinical motor function scores. Conclusions This study demonstrates that HD-EMG can capture detailed motor unit activity and neural control characteristics across multiple forearm muscles in individuals with chronic stroke. By integrating multiple HD-EMG features, this approach provides new insights into neuromuscular alterations linked to hand motor function after stroke. These findings support the use of HD-EMG for monitoring recovery, predicting outcomes, and guiding more targeted rehabilitation, thus advancing both stroke research and patient care.
Open AccessLeveraging neural drive to assess hand motor function in individuals with chronic stroke
Background Stroke is a leading cause of disability, with up to 80% of survivors experiencing motor impairments. These impairments are attributed to various factors, including reduced neural drive and altered motor unit firing patterns. Rehabilitation aims to restore motor function by enhancing motor unit recruitment and synchronization. High-density electromyography (HD-EMG) is a valuable tool for evaluating these changes in motor unit activity. Methods We tested a HD-EMG wearable forearm sleeve to investigate the relationship between motor function and motor unit properties including firing rate, motor unit module activation, and coherence. Seven individuals with chronic stroke and seven able-bodied individuals attempted 12 controlled hand and wrist movements while EMG was recorded. Motor units were decomposed across all movements using convolutive blind source separation. Results Fewer motor units were detectable in individuals with stroke compared to able-bodied participants. There was a significant reduction in motor unit firing rate during specific movements such as wrist flexion and hand open. Motor unit coupling and activation were altered following stroke, with reduced module activation in 8 of the 12 movements attempted. Furthermore, a reduction in coherence for gross movements and an increase in coherence for more dexterous thumb movements suggest altered neural drive to motor units after stroke that is differentially tuned to the complexity of movement. A combined neural control signature, consisting of multiple motor unit features, demonstrated strong correlation ( R 2 =0.81 ) with clinical motor function scores. Conclusions This study demonstrates that HD-EMG can capture detailed motor unit activity and neural control characteristics across multiple forearm muscles in individuals with chronic stroke. By integrating multiple HD-EMG features, this approach provides new insights into neuromuscular alterations linked to hand motor function after stroke. These findings support the use of HD-EMG for monitoring recovery, predicting outcomes, and guiding more targeted rehabilitation, thus advancing both stroke research and patient care.
- Open Access
- 1 August 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (4) , 046040
Identifying alterations in hand movement coordination from chronic stroke survivors using a wearable high-density EMG sleeve
Objective. Non-invasive, high-density electromyography (HD-EMG) has emerged as a useful tool to collect a range of neurophysiological motor information. Recent studies have demonstrated changes in EMG features that occur after stroke, which correlate with functional ability, highlighting their potential use as biomarkers. However, previous studies have largely explored these EMG features in isolation with individual electrodes to assess gross movements, limiting their potential clinical utility. This study aims to predict hand function of stroke survivors by combining interpretable features extracted from a wearable HD-EMG forearm sleeve. Approach. Here, able-bodied (N = 7) and chronic stroke subjects (N = 7) performed 12 functional hand and wrist movements while HD-EMG was recorded using a wearable sleeve. A variety of HD-EMG features, or views, were decomposed to assess alterations in motor coordination. Main Results. Stroke subjects, on average, had higher co-contraction and reduced muscle coupling when attempting to open their hand and actuate their thumb. Additionally, muscle synergies decomposed in the stroke population were relatively preserved, with a large spatial overlap in composition of matched synergies. Alterations in synergy composition demonstrated reduced coupling between digit extensors and muscles that actuate the thumb, as well as an increase in flexor activity in the stroke group. Average synergy activations during movements revealed differences in coordination, highlighting overactivation of antagonist muscles and compensatory strategies. When combining co-contraction and muscle synergy features, the first principal component was strongly correlated with upper-extremity Fugl Meyer hand sub-score of stroke participants (R 2 = 0.86). Principal component embeddings of individual features revealed interpretable measures of motor coordination and muscle coupling alterations. Significance. These results demonstrate the feasibility of predicting motor function through features decomposed from a wearable HD-EMG sleeve, which could be leveraged to improve stroke research and clinical care.
- 1 August 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (4) , 046040
Open AccessIdentifying alterations in hand movement coordination from chronic stroke survivors using a wearable high-density EMG sleeve
Objective. Non-invasive, high-density electromyography (HD-EMG) has emerged as a useful tool to collect a range of neurophysiological motor information. Recent studies have demonstrated changes in EMG features that occur after stroke, which correlate with functional ability, highlighting their potential use as biomarkers. However, previous studies have largely explored these EMG features in isolation with individual electrodes to assess gross movements, limiting their potential clinical utility. This study aims to predict hand function of stroke survivors by combining interpretable features extracted from a wearable HD-EMG forearm sleeve. Approach. Here, able-bodied (N = 7) and chronic stroke subjects (N = 7) performed 12 functional hand and wrist movements while HD-EMG was recorded using a wearable sleeve. A variety of HD-EMG features, or views, were decomposed to assess alterations in motor coordination. Main Results. Stroke subjects, on average, had higher co-contraction and reduced muscle coupling when attempting to open their hand and actuate their thumb. Additionally, muscle synergies decomposed in the stroke population were relatively preserved, with a large spatial overlap in composition of matched synergies. Alterations in synergy composition demonstrated reduced coupling between digit extensors and muscles that actuate the thumb, as well as an increase in flexor activity in the stroke group. Average synergy activations during movements revealed differences in coordination, highlighting overactivation of antagonist muscles and compensatory strategies. When combining co-contraction and muscle synergy features, the first principal component was strongly correlated with upper-extremity Fugl Meyer hand sub-score of stroke participants (R 2 = 0.86). Principal component embeddings of individual features revealed interpretable measures of motor coordination and muscle coupling alterations. Significance. These results demonstrate the feasibility of predicting motor function through features decomposed from a wearable HD-EMG sleeve, which could be leveraged to improve stroke research and clinical care.
- Open Access
Identifying alterations in hand movement coordination from chronic stroke survivors using a wearable high-density EMG sleeve
Non-invasive, high-density electromyography (HD-EMG) has emerged as a useful tool to collect a range of neurophysiological motor information. Recent studies have demonstrated changes in EMG features that occur after stroke, which correlate with functional ability, highlighting their potential use as biomarkers. However, previous studies have largely explored these EMG features in isolation with individual electrodes to assess gross movements, limiting their potential clinical utility. Here, able-bodied (N=7) and chronic stroke subjects (N=7) performed 12 functional hand and wrist movements while HD-EMG was recorded using a wearable sleeve. We demonstrate that a variety of HD-EMG features, or views, can be decomposed from the wearable sleeve. Stroke subjects, on average, had higher co-contraction and reduced muscle coupling when attempting to open their hand and actuate their thumb. In an expanded dataset consisting of 37 movements, we characterized muscle synergies in the forearm of able-bodied individuals. We found that the high-density array provides additional resolution over manually placed electrodes, which may help dissociate finer nuances in motor control. Additionally, muscle synergies decomposed in the stroke population were relatively preserved, with a large spatial overlap in composition of matched synergies. Alterations in synergy composition demonstrated reduced coupling between digit extensors and muscles that actuate the thumb, as well as an increase in flexor activity in the stroke group. Average synergy activations during movements revealed differences in coordination, highlighting overactivation of antagonist muscles and compensatory strategies. When combining co-contraction and muscle synergy features, the first principal component was correlated with upper-extremity Fugl Meyer hand sub-score of stroke participants (R 2 =0.86). Principal component embeddings of individual features revealed interpretable measures of motor coordination and muscle coupling alterations. These results demonstrate the feasibility of predicting motor function through features decomposed from a wearable HD-EMG sleeve, which could be leveraged to improve stroke research and clinical care.
Open AccessIdentifying alterations in hand movement coordination from chronic stroke survivors using a wearable high-density EMG sleeve
Non-invasive, high-density electromyography (HD-EMG) has emerged as a useful tool to collect a range of neurophysiological motor information. Recent studies have demonstrated changes in EMG features that occur after stroke, which correlate with functional ability, highlighting their potential use as biomarkers. However, previous studies have largely explored these EMG features in isolation with individual electrodes to assess gross movements, limiting their potential clinical utility. Here, able-bodied (N=7) and chronic stroke subjects (N=7) performed 12 functional hand and wrist movements while HD-EMG was recorded using a wearable sleeve. We demonstrate that a variety of HD-EMG features, or views, can be decomposed from the wearable sleeve. Stroke subjects, on average, had higher co-contraction and reduced muscle coupling when attempting to open their hand and actuate their thumb. In an expanded dataset consisting of 37 movements, we characterized muscle synergies in the forearm of able-bodied individuals. We found that the high-density array provides additional resolution over manually placed electrodes, which may help dissociate finer nuances in motor control. Additionally, muscle synergies decomposed in the stroke population were relatively preserved, with a large spatial overlap in composition of matched synergies. Alterations in synergy composition demonstrated reduced coupling between digit extensors and muscles that actuate the thumb, as well as an increase in flexor activity in the stroke group. Average synergy activations during movements revealed differences in coordination, highlighting overactivation of antagonist muscles and compensatory strategies. When combining co-contraction and muscle synergy features, the first principal component was correlated with upper-extremity Fugl Meyer hand sub-score of stroke participants (R 2 =0.86). Principal component embeddings of individual features revealed interpretable measures of motor coordination and muscle coupling alterations. These results demonstrate the feasibility of predicting motor function through features decomposed from a wearable HD-EMG sleeve, which could be leveraged to improve stroke research and clinical care.
- 5 January 2022
- Published by Wolters Kluwer Health in Journal of Strength & Conditioning Research
- Vol. 36 (3) , 867-870
Quantification of Global Myoelectric Spatial Activations to Delineate Normal Hamstring Function at Progressive Running Speeds: A Technical Report
Schlink, BR, Nordin, AD, Diekfuss, JA, and Myer, GD. Quantification of global myoelectric spatial activations to delineate normal hamstring function at progressive running speeds: A technical report. J Strength Cond Res 36(3): 867–870, 2022—Hamstring function is critical to maintain sport performance, and strain injuries to the biceps femoris muscle commonly force an athlete to withdraw from their sport while the muscle heals. Current mechanistic understanding of underlying injury and return-to-play (RTP) guidelines has limited prognostic value because of limitations in technology and nonfunctional assessment strategies to guide clinical care. Integrated structural and functional determinants and dynamic assessment methods are needed to guide advanced rehabilitation strategies for safe and rapid return to sport. A potential solution for assessment of hamstring function is high-density electromyography (EMG), which can noninvasively measure spatial muscle activity in dynamic environments. In this study, we demonstrated the utility of high-density EMG by measuring spatial myoelectric activity from the biceps femoris from a group of recreational athletes running at a range of speeds. The level of significance set for this study was p < 0.05. During the late swing phase of running, we observed increased EMG amplitudes in the central and distal portions of the muscle. There were no changes in this pattern of EMG activation across speed, suggesting that running speed does not affect the general neuromuscular recruitment in the biceps femoris. Applying these methods to athletes with hamstring strains may lead to a more complete understanding of muscle function during rehabilitation and adjunctively support current methods to enhance RTP decision-making.
- 5 January 2022
- Published by Wolters Kluwer Health in Journal of Strength & Conditioning Research
- Vol. 36 (3) , 867-870
Quantification of Global Myoelectric Spatial Activations to Delineate Normal Hamstring Function at Progressive Running Speeds: A Technical Report
Schlink, BR, Nordin, AD, Diekfuss, JA, and Myer, GD. Quantification of global myoelectric spatial activations to delineate normal hamstring function at progressive running speeds: A technical report. J Strength Cond Res 36(3): 867–870, 2022—Hamstring function is critical to maintain sport performance, and strain injuries to the biceps femoris muscle commonly force an athlete to withdraw from their sport while the muscle heals. Current mechanistic understanding of underlying injury and return-to-play (RTP) guidelines has limited prognostic value because of limitations in technology and nonfunctional assessment strategies to guide clinical care. Integrated structural and functional determinants and dynamic assessment methods are needed to guide advanced rehabilitation strategies for safe and rapid return to sport. A potential solution for assessment of hamstring function is high-density electromyography (EMG), which can noninvasively measure spatial muscle activity in dynamic environments. In this study, we demonstrated the utility of high-density EMG by measuring spatial myoelectric activity from the biceps femoris from a group of recreational athletes running at a range of speeds. The level of significance set for this study was p < 0.05. During the late swing phase of running, we observed increased EMG amplitudes in the central and distal portions of the muscle. There were no changes in this pattern of EMG activation across speed, suggesting that running speed does not affect the general neuromuscular recruitment in the biceps femoris. Applying these methods to athletes with hamstring strains may lead to a more complete understanding of muscle function during rehabilitation and adjunctively support current methods to enhance RTP decision-making.
- Open Access
- 1 May 2021
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 125 (5) , 2013-2023
Fatigue induces altered spatial myoelectric activation patterns in the medial gastrocnemius during locomotion
This research investigates the effects of muscle fatigue on spatial myoelectric patterns in the lower limb during locomotion. Both spatial and frequency aspects of neuromuscular recruitment in the medial gastrocnemius change in response to fatigue, resulting in altered myoelectric patterns during walking and running. These data may help us better understand the adaptations that occur in lower limb muscles to avoid overuse injuries caused by fatigue.
- 1 May 2021
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 125 (5) , 2013-2023
Open AccessFatigue induces altered spatial myoelectric activation patterns in the medial gastrocnemius during locomotion
This research investigates the effects of muscle fatigue on spatial myoelectric patterns in the lower limb during locomotion. Both spatial and frequency aspects of neuromuscular recruitment in the medial gastrocnemius change in response to fatigue, resulting in altered myoelectric patterns during walking and running. These data may help us better understand the adaptations that occur in lower limb muscles to avoid overuse injuries caused by fatigue.
- Open Access
- 5 December 2020
- Published by Wiley in Physiological Reports
- Vol. 8 (23) , e14652
Human myoelectric spatial patterns differ among lower limb muscles and locomotion speeds
Dynamic high‐density electromyography (EMG) recordings revealed heterogeneous spatial myoelectric patterns in lower limb muscles during locomotion. Spatial EMG activity became more localized as locom...
- 5 December 2020
- Published by Wiley in Physiological Reports
- Vol. 8 (23) , e14652
Open AccessHuman myoelectric spatial patterns differ among lower limb muscles and locomotion speeds
Dynamic high‐density electromyography (EMG) recordings revealed heterogeneous spatial myoelectric patterns in lower limb muscles during locomotion. Spatial EMG activity became more localized as locom...
- Open Access
- 3 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 1, 156-165
Comparison of Signal Processing Methods for Reducing Motion Artifacts in High-Density Electromyography During Human Locomotion
Objective: High-density electromyography (EMG) is useful for studying changes in myoelectrical activity within a muscle during human movement but is prone to motion artifacts during locomotion. We compared canonical correlation analysis and principal component analysis methods for signal decomposition and component filtering with a traditional EMG high-pass filtering approach to quantify their relative performance at removing motion artifacts from high-density EMG of the gastrocnemius and tibialis anterior muscles during human walking and running. Results: Canonical correlation analysis filtering provided a greater reduction in signal content at frequency bands associated with motion artifacts than either traditional high-pass filtering or principal component analysis filtering. Canonical correlation analysis filtering also minimized signal reduction at frequency bands expected to consist of true myoelectric signal. Conclusions: Canonical correlation analysis filtering appears to outperform a standard high-pass filter and principal component analysis filter in cleaning high-density EMG collected during fast walking or running.
- 3 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 1, 156-165
Open AccessComparison of Signal Processing Methods for Reducing Motion Artifacts in High-Density Electromyography During Human Locomotion
Objective: High-density electromyography (EMG) is useful for studying changes in myoelectrical activity within a muscle during human movement but is prone to motion artifacts during locomotion. We compared canonical correlation analysis and principal component analysis methods for signal decomposition and component filtering with a traditional EMG high-pass filtering approach to quantify their relative performance at removing motion artifacts from high-density EMG of the gastrocnemius and tibialis anterior muscles during human walking and running. Results: Canonical correlation analysis filtering provided a greater reduction in signal content at frequency bands associated with motion artifacts than either traditional high-pass filtering or principal component analysis filtering. Canonical correlation analysis filtering also minimized signal reduction at frequency bands expected to consist of true myoelectric signal. Conclusions: Canonical correlation analysis filtering appears to outperform a standard high-pass filter and principal component analysis filter in cleaning high-density EMG collected during fast walking or running.
- Open Access
- 9 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 27 (12) , 2378-2385
A Lower Limb Phantom for Simulation and Assessment of Electromyography Technology
Electromyography signal processing approaches have traditionally been validated through computer simulations. Electromyography electrodes and systems are often not validated or have been validated on human subjects where there is no clear ground truth signal for comparison. We sought to develop a physical limb phantom for validation of electromyography hardware and signal processing approaches. We embedded pairs of wires within a conductive gelatin surrounding an artificial bone such that the antennae could broadcast identified ground truth signals. The ground truth signals can be simple sinusoids or more complex representations of muscle activity. With the phantom and surface electromyography electrodes, we were able to show varying levels of crosstalk between nearby recording electrodes as we altered the amplitude of the antennae signals. We were also able to induce motion artifacts in our recordings by lightly dropping the phantom on a surface while antennae broadcast signals. High-density electromyography recordings of the trials showed that traditional filtering techniques fail to fully eliminate relatively small motion artifacts. The results suggest that the electrical limb phantom could be a valuable tool for testing potential effects of muscle crosstalk and motion artifacts on different electromyography systems and signal processing approaches.
- 9 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 27 (12) , 2378-2385
Open AccessA Lower Limb Phantom for Simulation and Assessment of Electromyography Technology
Electromyography signal processing approaches have traditionally been validated through computer simulations. Electromyography electrodes and systems are often not validated or have been validated on human subjects where there is no clear ground truth signal for comparison. We sought to develop a physical limb phantom for validation of electromyography hardware and signal processing approaches. We embedded pairs of wires within a conductive gelatin surrounding an artificial bone such that the antennae could broadcast identified ground truth signals. The ground truth signals can be simple sinusoids or more complex representations of muscle activity. With the phantom and surface electromyography electrodes, we were able to show varying levels of crosstalk between nearby recording electrodes as we altered the amplitude of the antennae signals. We were also able to induce motion artifacts in our recordings by lightly dropping the phantom on a surface while antennae broadcast signals. High-density electromyography recordings of the trials showed that traditional filtering techniques fail to fully eliminate relatively small motion artifacts. The results suggest that the electrical limb phantom could be a valuable tool for testing potential effects of muscle crosstalk and motion artifacts on different electromyography systems and signal processing approaches.
- Open Access
- 7 May 2018
- Published by SAGE Publications in HIP International
- Vol. 29 (2) , 209-214
Gait asymmetries in unilateral symptomatic hip osteoarthritis and their association with radiographic severity and pain
Little is known about the loading patterns in unilateral hip osteoarthritis (OA) and their relationship to radiographic severity and pain. We aimed to examine the loading patterns at the hips of those with unilateral symptomatic hip OA and identify associations between radiographic severity and pain with loading alterations. 61 subjects with symptomatic unilateral hip OA underwent gait analyses and evaluation for radiographic severity (Kellgren-Lawrence [KL]-grade) and pain (visual analogue scale) at bilateral hips. Hip OA subjects had greater range of motion and higher hip flexion, adduction, internal and external rotation moments at the contralateral, asymptomatic hip compared to the ipsilateral hip (p < 0.05). Correlations were noted between increasing KL-grade and increasing asymmetry of contralateral to ipsilateral hip loading (p < 0.05). There were no relationships with pain and loading asymmetry. Unilateral symptomatic hip OA subjects demonstrate asymmetry in loading between the hips, with relatively greater loads at the contralateral hip. These loading asymmetries were directly related to the radiographic severity of symptomatic hip OA and not with pain. Additional research is needed to determine the role of gait asymmetries in disease progression.
- 7 May 2018
- Published by SAGE Publications in HIP International
- Vol. 29 (2) , 209-214
Open AccessGait asymmetries in unilateral symptomatic hip osteoarthritis and their association with radiographic severity and pain
Little is known about the loading patterns in unilateral hip osteoarthritis (OA) and their relationship to radiographic severity and pain. We aimed to examine the loading patterns at the hips of those with unilateral symptomatic hip OA and identify associations between radiographic severity and pain with loading alterations. 61 subjects with symptomatic unilateral hip OA underwent gait analyses and evaluation for radiographic severity (Kellgren-Lawrence [KL]-grade) and pain (visual analogue scale) at bilateral hips. Hip OA subjects had greater range of motion and higher hip flexion, adduction, internal and external rotation moments at the contralateral, asymptomatic hip compared to the ipsilateral hip (p < 0.05). Correlations were noted between increasing KL-grade and increasing asymmetry of contralateral to ipsilateral hip loading (p < 0.05). There were no relationships with pain and loading asymmetry. Unilateral symptomatic hip OA subjects demonstrate asymmetry in loading between the hips, with relatively greater loads at the contralateral hip. These loading asymmetries were directly related to the radiographic severity of symptomatic hip OA and not with pain. Additional research is needed to determine the role of gait asymmetries in disease progression.
- Open Access
- 16 June 2017
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 11, 310
Independent Component Analysis and Source Localization on Mobile EEG Data Can Identify Increased Levels of Acute Stress
Mobile electroencephalography (EEG) is a very useful tool to investigate the physiological basis of cognition under real-world conditions. However, as we move experimentation into less-constrained environments, the influence of state changes increases. The influence of stress on cortical activity and cognition is an important example. Monitoring of modulation of cortical activity by EEG measurements is a promising tool for assessing acute stress. In this study, we test this hypothesis and combine EEG with independent component analysis and source localization to identify cortical differences between a control condition and a stressful condition. Subjects performed a stationary shooting task using an airsoft rifle with and without the threat of an experimenter firing a different airsoft rifle in their direction. We observed significantly higher skin conductance responses and salivary cortisol levels (p < 0.05 for both) during the stressful conditions, indicating that we had successfully induced an adequate level of acute stress. We located independent components in five regions throughout the cortex, most notably in the dorsolateral prefrontal cortex, a region previously shown to be affected by increased levels of stress. This area showed a significant decrease in spectral power in the theta and alpha bands less than a second after the subjects pulled the trigger. Overall, our results suggest that EEG with independent component analysis and source localization has the potential of monitoring acute stress in real-world environments.
- 16 June 2017
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 11, 310
Open AccessIndependent Component Analysis and Source Localization on Mobile EEG Data Can Identify Increased Levels of Acute Stress
Mobile electroencephalography (EEG) is a very useful tool to investigate the physiological basis of cognition under real-world conditions. However, as we move experimentation into less-constrained environments, the influence of state changes increases. The influence of stress on cortical activity and cognition is an important example. Monitoring of modulation of cortical activity by EEG measurements is a promising tool for assessing acute stress. In this study, we test this hypothesis and combine EEG with independent component analysis and source localization to identify cortical differences between a control condition and a stressful condition. Subjects performed a stationary shooting task using an airsoft rifle with and without the threat of an experimenter firing a different airsoft rifle in their direction. We observed significantly higher skin conductance responses and salivary cortisol levels (p < 0.05 for both) during the stressful conditions, indicating that we had successfully induced an adequate level of acute stress. We located independent components in five regions throughout the cortex, most notably in the dorsolateral prefrontal cortex, a region previously shown to be affected by increased levels of stress. This area showed a significant decrease in spectral power in the theta and alpha bands less than a second after the subjects pulled the trigger. Overall, our results suggest that EEG with independent component analysis and source localization has the potential of monitoring acute stress in real-world environments.