Si Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Si Huang has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Bo Chen
Key Laboratory of Phytochemical R&D of Hunan Province and Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research of Ministry of Education, Hunan Normal University, Changsha 410081, China
7 shared publications - Gert Ij. Salentijn
Laboratory of Organic Chemistry, Wageningen University & Research, Stippeneng 4, 6708 WE, Wageningen, the Netherlands; Wageningen Food Safety Research, Wageningen University & Research, Akkermaalsbos 2, 6708 WB, Wageningen, the Netherlands
6 shared publications - Han Zuilhof
College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, Zhejiang, China
6 shared publications Ming Ma
Key Laboratory of Phytochemical R&D of Hunan Province and Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research of Ministry of Education, Hunan Normal University, No.36, Lushan Road, Changsha 410081, China
5 shared publicationsTeris A. van Beek
Laboratory of Organic Chemistry, Wageningen University, Stippeneng 4, Wageningen 6708 WE, The Netherlands
4 shared publicationsFrank W. Claassen
Laboratory of Organic Chemistry, Wageningen University, Stippeneng 4, Wageningen 6708 WE, The Netherlands
3 shared publications
Latest Publications
- Open Access
- 11 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (25) , 10170-10181
Ultrafast, Selective, and Highly Sensitive Nonchromatographic Analysis of Fourteen Cannabinoids in Cannabis Extracts, Δ8-Tetrahydrocannabinol Synthetic Mixtures, and Edibles by Cyclic Ion Mobility Spectrometry–Mass Spectrometry
The diversity of cannabinoid isomers and complexity of Cannabis products pose significant challenges for analytical methodologies. In this study, we developed a method to analyze 14 different cannabinoid isomers in diverse samples within milliseconds by leveraging the unique adduct-forming behavior of silver ions in advanced cyclic ion mobility spectrometry-mass spectrometry. The developed method achieved the separation of isomers from four groups of cannabinoids: Δ3-tetrahydrocannabinol (THC) (1), Δ8-THC (2), Δ9-THC (3), cannabidiol (CBD) (4), Δ8-iso-THC (5), and Δ(4)8-iso-THC (6) (all MW = 314); 9α-hydroxyhexahydrocannabinol (7), 9β-hydroxyhexahydrocannabinol (8), and 8-hydroxy-iso-THC (9) (all MW = 332); tetrahydrocannabinolic acid (THCA) (10) and cannabidiolic acid (CBDA) (11) (both MW = 358); Δ8-tetrahydrocannabivarin (THCV) (12), Δ8-iso-THCV (13), and Δ9-THCV (14) (all MW = 286). Moreover, experimental and theoretical traveling wave collision cross section values in nitrogen (TWCCSN2) of cannabinoid-Ag(I) species were obtained for the first time with an average error between experimental and theoretical values of 2.6%. Furthermore, a workflow for the identification of cannabinoid isomers in Cannabis and Cannabis-derived samples was established based on three identification steps (m/z and isotope pattern of Ag(I) adducts, TWCCSN2, and MS/MS fragments). Afterward, calibration curves of three major cannabinoids were established with a linear range of 1-250 ng·ml-1 for Δ8-THC (2) (R2 = 0.9999), 0.1-25 ng·ml-1 for Δ9-THC (3) (R2 = 0.9987), and 0.04-10 ng·ml-1 for CBD (4) (R2 = 0.9986) as well as very low limits of detection (0.008-0.2 ng·ml-1). Finally, relative quantification of Δ8-THC (2), Δ9-THC (3), and CBD (4) in eight complex acid-treated CBD mixtures was achieved without chromatographic separation. The results showed good correspondence (R2 = 0.999) with those obtained by gas chromatography-flame ionization detection/mass spectrometry.
- 11 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (25) , 10170-10181
Open AccessUltrafast, Selective, and Highly Sensitive Nonchromatographic Analysis of Fourteen Cannabinoids in Cannabis Extracts, Δ8-Tetrahydrocannabinol Synthetic Mixtures, and Edibles by Cyclic Ion Mobility Spectrometry–Mass Spectrometry
The diversity of cannabinoid isomers and complexity of Cannabis products pose significant challenges for analytical methodologies. In this study, we developed a method to analyze 14 different cannabinoid isomers in diverse samples within milliseconds by leveraging the unique adduct-forming behavior of silver ions in advanced cyclic ion mobility spectrometry-mass spectrometry. The developed method achieved the separation of isomers from four groups of cannabinoids: Δ3-tetrahydrocannabinol (THC) (1), Δ8-THC (2), Δ9-THC (3), cannabidiol (CBD) (4), Δ8-iso-THC (5), and Δ(4)8-iso-THC (6) (all MW = 314); 9α-hydroxyhexahydrocannabinol (7), 9β-hydroxyhexahydrocannabinol (8), and 8-hydroxy-iso-THC (9) (all MW = 332); tetrahydrocannabinolic acid (THCA) (10) and cannabidiolic acid (CBDA) (11) (both MW = 358); Δ8-tetrahydrocannabivarin (THCV) (12), Δ8-iso-THCV (13), and Δ9-THCV (14) (all MW = 286). Moreover, experimental and theoretical traveling wave collision cross section values in nitrogen (TWCCSN2) of cannabinoid-Ag(I) species were obtained for the first time with an average error between experimental and theoretical values of 2.6%. Furthermore, a workflow for the identification of cannabinoid isomers in Cannabis and Cannabis-derived samples was established based on three identification steps (m/z and isotope pattern of Ag(I) adducts, TWCCSN2, and MS/MS fragments). Afterward, calibration curves of three major cannabinoids were established with a linear range of 1-250 ng·ml-1 for Δ8-THC (2) (R2 = 0.9999), 0.1-25 ng·ml-1 for Δ9-THC (3) (R2 = 0.9987), and 0.04-10 ng·ml-1 for CBD (4) (R2 = 0.9986) as well as very low limits of detection (0.008-0.2 ng·ml-1). Finally, relative quantification of Δ8-THC (2), Δ9-THC (3), and CBD (4) in eight complex acid-treated CBD mixtures was achieved without chromatographic separation. The results showed good correspondence (R2 = 0.999) with those obtained by gas chromatography-flame ionization detection/mass spectrometry.
- Open Access
- 10 April 2024
- Published by Wiley in Angewandte Chemie
- Vol. 136 (20) , e202403474
Rim‐Based Binding of Perfluorinated Acids to Pillararenes Purifies Water
Per‐ and polyfluoroalkyl substances (PFAS) pose a rapidly increasing global problem as their widespread use and high stability lead worldwide to water contamination, with significant detrimental health effects.[1] Supramolecular chemistry has been invoked to develop materials geared towards the specific capture of PFAS from water,[2] to reduce the concentration below advisory safety limits (e.g., 70 ng/L for the sum of perfluorooctane sulfonic acid, PFOS and perfluorooctanoic acid, PFOA). Scale‐up and use in natural waters with high PFAS concentrations has hitherto posed a problem. Here we report a new type of host–guest interaction between deca‐ammonium‐functionalized pillar[5]arenes (DAF−P5s) and perfluoroalkyl acids. DAF−P5 complexes show an unprecedented 1 : 10 stoichiometry, as confirmed by isothermal calorimetry and X‐ray crystallographic studies, and high binding constants (up to 106 M−1) to various polyfluoroalkyl acids. In addition, non‐fluorinated acids do not hamper this process significantly. Immobilization of DAF−P5s allows a simple single‐time filtration of PFAS‐contaminated water to reduce the PFOS/PFOA concentration 106 times to 15–50 ng/L level. The effective and fast (10 regeneration cycles without decrease in performance) set a new benchmark in PFAS‐absorbing materials.
- 10 April 2024
- Published by Wiley in Angewandte Chemie
- Vol. 136 (20) , e202403474
Open AccessRim‐Based Binding of Perfluorinated Acids to Pillararenes Purifies Water
Per‐ and polyfluoroalkyl substances (PFAS) pose a rapidly increasing global problem as their widespread use and high stability lead worldwide to water contamination, with significant detrimental health effects.[1] Supramolecular chemistry has been invoked to develop materials geared towards the specific capture of PFAS from water,[2] to reduce the concentration below advisory safety limits (e.g., 70 ng/L for the sum of perfluorooctane sulfonic acid, PFOS and perfluorooctanoic acid, PFOA). Scale‐up and use in natural waters with high PFAS concentrations has hitherto posed a problem. Here we report a new type of host–guest interaction between deca‐ammonium‐functionalized pillar[5]arenes (DAF−P5s) and perfluoroalkyl acids. DAF−P5 complexes show an unprecedented 1 : 10 stoichiometry, as confirmed by isothermal calorimetry and X‐ray crystallographic studies, and high binding constants (up to 106 M−1) to various polyfluoroalkyl acids. In addition, non‐fluorinated acids do not hamper this process significantly. Immobilization of DAF−P5s allows a simple single‐time filtration of PFAS‐contaminated water to reduce the PFOS/PFOA concentration 106 times to 15–50 ng/L level. The effective and fast (10 regeneration cycles without decrease in performance) set a new benchmark in PFAS‐absorbing materials.
- Open Access
- 10 April 2024
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 63 (20) , e202403474
Rim‐Based Binding of Perfluorinated Acids to Pillararenes Purifies Water
Per‐ and polyfluoroalkyl substances (PFAS) pose a rapidly increasing global problem as their widespread use and high stability lead worldwide to water contamination, with significant detrimental health effects.[1] Supramolecular chemistry has been invoked to develop materials geared towards the specific capture of PFAS from water,[2] to reduce the concentration below advisory safety limits (e.g., 70 ng/L for the sum of perfluorooctane sulfonic acid, PFOS and perfluorooctanoic acid, PFOA). Scale‐up and use in natural waters with high PFAS concentrations has hitherto posed a problem. Here we report a new type of host–guest interaction between deca‐ammonium‐functionalized pillar[5]arenes (DAF−P5s) and perfluoroalkyl acids. DAF−P5 complexes show an unprecedented 1 : 10 stoichiometry, as confirmed by isothermal calorimetry and X‐ray crystallographic studies, and high binding constants (up to 106 M−1) to various polyfluoroalkyl acids. In addition, non‐fluorinated acids do not hamper this process significantly. Immobilization of DAF−P5s allows a simple single‐time filtration of PFAS‐contaminated water to reduce the PFOS/PFOA concentration 106 times to 15–50 ng/L level. The effective and fast (10 regeneration cycles without decrease in performance) set a new benchmark in PFAS‐absorbing materials.
- 10 April 2024
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 63 (20) , e202403474
Open AccessRim‐Based Binding of Perfluorinated Acids to Pillararenes Purifies Water
Per‐ and polyfluoroalkyl substances (PFAS) pose a rapidly increasing global problem as their widespread use and high stability lead worldwide to water contamination, with significant detrimental health effects.[1] Supramolecular chemistry has been invoked to develop materials geared towards the specific capture of PFAS from water,[2] to reduce the concentration below advisory safety limits (e.g., 70 ng/L for the sum of perfluorooctane sulfonic acid, PFOS and perfluorooctanoic acid, PFOA). Scale‐up and use in natural waters with high PFAS concentrations has hitherto posed a problem. Here we report a new type of host–guest interaction between deca‐ammonium‐functionalized pillar[5]arenes (DAF−P5s) and perfluoroalkyl acids. DAF−P5 complexes show an unprecedented 1 : 10 stoichiometry, as confirmed by isothermal calorimetry and X‐ray crystallographic studies, and high binding constants (up to 106 M−1) to various polyfluoroalkyl acids. In addition, non‐fluorinated acids do not hamper this process significantly. Immobilization of DAF−P5s allows a simple single‐time filtration of PFAS‐contaminated water to reduce the PFOS/PFOA concentration 106 times to 15–50 ng/L level. The effective and fast (10 regeneration cycles without decrease in performance) set a new benchmark in PFAS‐absorbing materials.
- Open Access
- 14 December 2023
- Published by Elsevier in Food Chemistry
- Vol. 440, 138187
Comprehensive cannabinoid profiling of acid-treated CBD samples and Δ8-THC-infused edibles
- 14 December 2023
- Published by Elsevier in Food Chemistry
- Vol. 440, 138187
Open AccessComprehensive cannabinoid profiling of acid-treated CBD samples and Δ8-THC-infused edibles
- Open Access
- 30 September 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (40) , 13710-13718
Semiquantitative Screening of THC Analogues by Silica Gel TLC with an Ag(I) Retention Zone and Chromogenic Smartphone Detection
With the ever-evolving cannabis industry, low-cost and high-throughput analytical methods for cannabinoids are urgently needed. Normally, (potentially) psychoactive cannabinoids, typically represented by Δ9-tetrahydrocannabinol (Δ9-THC), and nonpsychoactive cannabinoids with therapeutic benefits, typically represented by cannabidiol (CBD), are the target analytes. Structurally, the former (tetrahydrocannabinolic acid (THCA), cannabinol (CBN), and THC) have one olefinic double bond and the latter (cannabidiolic acid (CBDA), cannabigerol (CBG), and CBD) have two, which results in different affinities toward Ag(I) ions. Thus, a silica gel thin-layer chromatography (TLC) plate with the lower third impregnated with Ag(I) ions enabled within minutes a digital chromatographic separation of strongly retained CBD analogues and poorly retained THC analogues. The resolution (Rs) between the closest two spots from the two groups was 4.7, which is almost 8 times higher than the resolution on unmodified TLC. After applying Fast Blue BB as a chromogenic reagent, smartphone-based color analysis enabled semiquantification of the total percentage of THC analogues (with a limit of detection (LOD) of 11 ng for THC, 54 ng for CBN, and 50 ng for THCA when the loaded volume is 1.0 μL). The method was validated by analyzing mixed cannabis extracts and cannabis extracts. The results correlated with those of high-performance liquid chromatography with ultraviolet detection (HPLC-UV) (R2 = 0.97), but the TLC approach had the advantages of multi-minute analysis time, high throughput, low solvent consumption, portability, and ease of interpretation. In a desiccator, Ag(I)-TLC plates can be stored for at least 3 months. Therefore, this method would allow rapid distinction between high and low THC varieties of cannabis, with the potential for on-site applicability.
- 30 September 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (40) , 13710-13718
Open AccessSemiquantitative Screening of THC Analogues by Silica Gel TLC with an Ag(I) Retention Zone and Chromogenic Smartphone Detection
With the ever-evolving cannabis industry, low-cost and high-throughput analytical methods for cannabinoids are urgently needed. Normally, (potentially) psychoactive cannabinoids, typically represented by Δ9-tetrahydrocannabinol (Δ9-THC), and nonpsychoactive cannabinoids with therapeutic benefits, typically represented by cannabidiol (CBD), are the target analytes. Structurally, the former (tetrahydrocannabinolic acid (THCA), cannabinol (CBN), and THC) have one olefinic double bond and the latter (cannabidiolic acid (CBDA), cannabigerol (CBG), and CBD) have two, which results in different affinities toward Ag(I) ions. Thus, a silica gel thin-layer chromatography (TLC) plate with the lower third impregnated with Ag(I) ions enabled within minutes a digital chromatographic separation of strongly retained CBD analogues and poorly retained THC analogues. The resolution (Rs) between the closest two spots from the two groups was 4.7, which is almost 8 times higher than the resolution on unmodified TLC. After applying Fast Blue BB as a chromogenic reagent, smartphone-based color analysis enabled semiquantification of the total percentage of THC analogues (with a limit of detection (LOD) of 11 ng for THC, 54 ng for CBN, and 50 ng for THCA when the loaded volume is 1.0 μL). The method was validated by analyzing mixed cannabis extracts and cannabis extracts. The results correlated with those of high-performance liquid chromatography with ultraviolet detection (HPLC-UV) (R2 = 0.97), but the TLC approach had the advantages of multi-minute analysis time, high throughput, low solvent consumption, portability, and ease of interpretation. In a desiccator, Ag(I)-TLC plates can be stored for at least 3 months. Therefore, this method would allow rapid distinction between high and low THC varieties of cannabis, with the potential for on-site applicability.
- Open Access
- 12 February 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (8) , 3794-3802
Rapid Distinction and Semiquantitative Analysis of THC and CBD by Silver-Impregnated Paper Spray Mass Spectrometry
The control over the amount of psychoactive THC (Δ-9-tetrahydrocannabinol) in commercial cannabidiol (CBD) products has to be strict. A fast and simple semiquantitative Ag(I)-impregnated paper spray mass spectrometric method for differentiating between THC and CBD, which show no difference in standard single-stage or tandem MS, was established. Because of a different binding affinity to Ag(I) ions, quasi-molecular Ag(I) adducts [THC + Ag]+ and [CBD + Ag]+ at m/z 421 and 423 give different fragmentation patterns. The product ions at m/z 313 for THC and m/z 353 and 355 for CBD can be used to distinguish THC and CBD and to determine their ratio. Quantification of THC/CBD ratios in commercial CBD oils was accomplished with a low matrix effect (−2.2 ± 0.4% for THC and −2.0 ± 0.3% for CBD). After simple methanol extraction (recovery of 87.3 ± 1.2% for THC and 92.3 ± 1.4% for CBD), Ag(I)-impregnated paper spray analysis was employed to determine this ratio. A single run can be completed in a few minutes. This method was benchmarked against the UHPLC-UV method. Ag(I)-impregnated paper spray MS had the same working range (THC/CBD = 0.001–1) as UHPLC-UV analysis (R2 = 0.9896 and R2 = 0.9998, respectively), as well as comparable accuracy (−2.7 to 14%) and precision (RSD 1.7–11%). The method was further validated by the analysis of 10 commercial oils by Ag(I)-impregnated paper spray MS and UHPLC-UV analysis. Based on the determined relative concentration ratios of THC/CBD and the declared CBD concentration, 6 out of 10 CBD oils appear to contain more THC than the Dutch legal limit of 0.05%.
- 12 February 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (8) , 3794-3802
Open AccessRapid Distinction and Semiquantitative Analysis of THC and CBD by Silver-Impregnated Paper Spray Mass Spectrometry
The control over the amount of psychoactive THC (Δ-9-tetrahydrocannabinol) in commercial cannabidiol (CBD) products has to be strict. A fast and simple semiquantitative Ag(I)-impregnated paper spray mass spectrometric method for differentiating between THC and CBD, which show no difference in standard single-stage or tandem MS, was established. Because of a different binding affinity to Ag(I) ions, quasi-molecular Ag(I) adducts [THC + Ag]+ and [CBD + Ag]+ at m/z 421 and 423 give different fragmentation patterns. The product ions at m/z 313 for THC and m/z 353 and 355 for CBD can be used to distinguish THC and CBD and to determine their ratio. Quantification of THC/CBD ratios in commercial CBD oils was accomplished with a low matrix effect (−2.2 ± 0.4% for THC and −2.0 ± 0.3% for CBD). After simple methanol extraction (recovery of 87.3 ± 1.2% for THC and 92.3 ± 1.4% for CBD), Ag(I)-impregnated paper spray analysis was employed to determine this ratio. A single run can be completed in a few minutes. This method was benchmarked against the UHPLC-UV method. Ag(I)-impregnated paper spray MS had the same working range (THC/CBD = 0.001–1) as UHPLC-UV analysis (R2 = 0.9896 and R2 = 0.9998, respectively), as well as comparable accuracy (−2.7 to 14%) and precision (RSD 1.7–11%). The method was further validated by the analysis of 10 commercial oils by Ag(I)-impregnated paper spray MS and UHPLC-UV analysis. Based on the determined relative concentration ratios of THC/CBD and the declared CBD concentration, 6 out of 10 CBD oils appear to contain more THC than the Dutch legal limit of 0.05%.
- 21 January 2020
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 97 (3) , 778-785
Separation and Analysis of Ginsenoside Rg1: An Experiment for the Separation and Analysis of Natural Products
- 21 January 2020
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 97 (3) , 778-785
Separation and Analysis of Ginsenoside Rg1: An Experiment for the Separation and Analysis of Natural Products
- 26 November 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (1) , 908-915
Organic Electrochemical Transistor for in Situ Detection of H2O2 Released from Adherent Cells and Its Application in Evaluating the In Vitro Cytotoxicity of Nanomaterial
Detection of hydrogen peroxide (H2O2) produced by living cells is very significant to fully understand its roles in cellular physiology as well providing reliable diagnosis of pathological conditions. However, in situ detection of H2O2 released from adherent cells in cellular culture medium is still insufficiently achieved. Here we report an electrochemical platform for in situ detection of H2O2 produced by adherent cells in cellular culture medium. It is based on the use of organic electrochemical transistor (OECT) fabricated on a flexible poly-(ethylene terephthalate) substrate and Transwell support. A screen-printed carbon paste electrode was modified with carbon nanotubes and platinum nanoparticles and served as the gate of the device. Under optimal conditions, this device exhibits good modulation and sensitivity. It works in the 0.5 μM to 0.1 mM H2O2 concentration range and has a 0.2 μM detection limit. The cells were seeded and grew on the Transwell membrane. Upon stimulated by N-formylmethionyl-leucyl-phenylalanine peptide, the H2O2 produced by the adherent cells diffused into the bottom chamber of Transwell, and was in situ detected by OECT. Moreover, the evaluating in vitro cytotoxicity of nanomaterial using the OECT-Transwell platform was realized. This simple electrochemical platform would be of great interest for in vitro cytotoxicity, cellular physiology study and diagnosis of pathological conditions.
- 26 November 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (1) , 908-915
Organic Electrochemical Transistor for in Situ Detection of H2O2 Released from Adherent Cells and Its Application in Evaluating the In Vitro Cytotoxicity of Nanomaterial
Detection of hydrogen peroxide (H2O2) produced by living cells is very significant to fully understand its roles in cellular physiology as well providing reliable diagnosis of pathological conditions. However, in situ detection of H2O2 released from adherent cells in cellular culture medium is still insufficiently achieved. Here we report an electrochemical platform for in situ detection of H2O2 produced by adherent cells in cellular culture medium. It is based on the use of organic electrochemical transistor (OECT) fabricated on a flexible poly-(ethylene terephthalate) substrate and Transwell support. A screen-printed carbon paste electrode was modified with carbon nanotubes and platinum nanoparticles and served as the gate of the device. Under optimal conditions, this device exhibits good modulation and sensitivity. It works in the 0.5 μM to 0.1 mM H2O2 concentration range and has a 0.2 μM detection limit. The cells were seeded and grew on the Transwell membrane. Upon stimulated by N-formylmethionyl-leucyl-phenylalanine peptide, the H2O2 produced by the adherent cells diffused into the bottom chamber of Transwell, and was in situ detected by OECT. Moreover, the evaluating in vitro cytotoxicity of nanomaterial using the OECT-Transwell platform was realized. This simple electrochemical platform would be of great interest for in vitro cytotoxicity, cellular physiology study and diagnosis of pathological conditions.