JHJaesub Hong

Jaesub Hong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jaesub Hong has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hunting for High-mass X-Ray Binaries in the Galactic Center with NuSTAR

    by Shifra Mandel, Julian Gerber, Kaya Mori, Ceaser Stringfield, Mabel Peñaherrera, Charles J. Hailey, Alan Du, Jonathan Grindlay, JaeSub Hong, Gabriele Ponti, et al.

    The central 2 × 0.8 deg2 region of our Galaxy contains ∼10,000 X-ray point sources that were detected by a series of Chandra observations over the last two decades. However, the limited bandpass of Chandra below 8 keV hampered their spectroscopic classification. In 2016, the initial NuSTAR Galactic center (GC) survey detected 77 X-ray sources above 10 keV. The hard X-ray detections indicate magnetic cataclysmic variables, low-mass X-ray binaries, high-mass X-ray binaries (HMXBs), or even pulsars. The possibility of HMXB detections is particularly interesting given the dearth of identified HMXBs in the GC. We conducted a search for bright (K s ≲ 16 mag) near-infrared (NIR) counterparts to the hard X-ray sources—utilizing their Chandra positions—in order to identify HMXB candidates. We identified seven NuSTAR sources with NIR counterpart candidates whose magnitudes are consistent with HMXBs at the GC. We assessed the likelihood of random association for these seven sources, and determined that two have a nonrandom association with a probability exceeding 99.98%, making them strong HMXB candidates. We analyzed broadband NuSTAR, Chandra, and XMM-Newton spectral data for these two candidates, one of which was previously identified as a red supergiant. We find that the X-ray spectra are consistent with HMXBs. If confirmed through follow-up NIR spectroscopic studies, our findings will open a new window into our understanding of the intrinsic luminosity distribution of HMXBs in our Galaxy in general and the GC HMXB population in particular.


  • Miniature X-ray Optics for Meter-Class Focal Length Telescopes

    by Jaesub Hong, Suzanne Romaine, Vinay L. Kashyap, Kiranmayee Kilaru

  • Open Access

    Constraining the White-dwarf Mass and Magnetic Field Strength of a New Intermediate Polar through X-Ray Observations

    by Benjamin Vermette, Ciro Salcedo, Kaya Mori, Julian Gerber, Kyung Duk Yoon, Gabriel Bridges, Charles J. Hailey, Frank Haberl, Jaesub Hong, Jonathan Grindlay, et al.

    We report timing and broadband spectral analysis of a Galactic X-ray source, CXOGBS J174517.0−321356 (J1745), with a 614 s periodicity. Chandra discovered the source in the direction of the Galactic Bulge. Gong proposed that J1745 was either an intermediate polar (IP) with a mass of ∼1 M ⊙, or an ultracompact X-ray binary (UCXB). To confirm J1745's nature, we jointly fit XMM-Newton and NuSTAR spectra, ruling out a UCXB origin. We have developed a physically realistic model that considers a finite magnetosphere radius, X-ray absorption from the preshock region, and reflection from the white-dwarf (WD) surface to properly determine the IP properties, especially its WD mass. To assess systematic errors on the WD mass measurement, we consider a broad range of specific accretion rates ( m ̇ = 0.6 – 44 g cm−2 s−1) based on the uncertain source distance (d = 3–8 kpc) and fractional accretion area (f = 0.001–0.025). Our model properly implements the fitted accretion column height in the X-ray reflection model and accounts for the underestimated mass accretion rate due to the (unobserved) soft X-ray blackbody and cyclotron cooling emissions. We found that the lowest accretion rate of m ̇ = 0.6 g cm−2 s−1, which corresponds to the nearest source distance and maximum f value, yields a WD mass of (0.92 ± 0.08)M ⊙. On the other hand, as long as the accretion rate is m ̇ ≳ 3 g cm−2 s−1, the WD mass is robustly measured to be (0.81 ± 0.06)M ⊙, nearly independent of m ̇ . The derived WD mass range is consistent with the mean WD mass of nearby IPs. Assuming spin equilibrium between the WD and accretion disk, we constrained the WD magnetic field to B ≳ 7 MG, indicating that it could be a highly magnetized IP. Our analysis presents the most comprehensive methodology for constraining the WD mass and B field of an IP by consolidating the effects of cyclotron cooling, finite magnetospheric radius, and accretion column height.


  • Open Access

    Constraining white dwarf mass and magnetic field strength of a new intermediate polar through X-ray observations

    by Benjamin Vermette, Ciro Salcedo, Kaya Mori, Julian Gerber, Kyung Duk Yoon, Gabriel Bridges, Charles J. Hailey, Frank Haberl, Jaesub Hong, Jonathan Grindlay, et al.

    We report a broad-band analysis of a Galactic X-ray source, CXOGBS J174517.0-321356 (J1745), with a 614-second periodicity. Chandra discovered the source in the direction of the Galactic Bulge. Gong (2022) proposed J1745 was either an intermediate polar (IP) with a mass of ~1 $M_{\odot}$, or an ultra-compact X-ray binary (UCXB). By jointly fitting XMM-Newton and NuSTAR spectra, we rule out a UCXB origin. We have developed a physically realistic model that considers finite magnetosphere radius, X-ray absorption from the pre-shock region, and reflection from the WD surface to determine the IP properties, especially its WD mass. To assess systematic errors on WD mass measurement, we consider a broad range of specific accretion rates ($\dot{m}$ = 0.6 - 44 g\cm$^2$\s) based on the uncertain source distance (d = 3-8 kpc) and fractional accretion area (f = 0.001-0.025). Our model properly implements the fitted accretion column height in the X-ray reflection model and accounts for the underestimated mass accretion rate due to the (unobserved) soft X-ray blackbody and cyclotron cooling emissions. We found that the lowest accretion rate of $\dot{m}$ = 0.6 g\cm$^2$\s, which corresponds to the nearest source distance and maximum f value, yield the WD mass of $(0.92\pm0.08) M_{\odot}$. However, if the accretion rate is $\dot{m}$ > ~3 g\cm$^2$\s, the WD mass is robustly measured to be $(0.81\pm0.06) M_{\odot}$, nearly independent of $\dot{m}$. The derived WD mass range is consistent with the mean WD mass of nearby IPs. Assuming spin equilibrium between the WD and accretion disk, we constrained the WD magnetic field to B > ~7 MG, indicating that it could be a highly magnetized IP. Our analysis presents the most comprehensive methodology for constraining the WD mass and B-field of an IP by consolidating the effects of cyclotron cooling, finite magnetospheric radius, and accretion column height.

  • Imaging effects due to pixel distortions in CdZnTe detectors—results from the HREXI Calibration Facility

    by Arkadip Basak, Branden Allen, Jaesub Hong, Daniel P. Violette, Jonathan Grindlay

    ProtoEXIST2 (P2) was a prototype imaging x-ray detector plane developed for wide-field time-domain astrophysics (TDA) in the 5 to 200 keV energy band. It was composed of an 8 × 8 array of 5 mm thick, 2 cm × 2 cm pixelated (32 × 32) CdZnTe (CZT) detectors with a 0.6-mm pitch that utilize the NuSTAR ASIC (NuASIC) for readout. During the initial detector development process leading up to postflight examination of the entire detector plane, distortions in expected pixel positions and shapes were observed in a significant fraction of the detectors. The High Resolution Energetic x-ray Imager (HREXI) calibration facility (HCF) was designed and commissioned to improve upon these early experiments and to rapidly map out and characterize pixel nonuniformities and defects within CZT detector planes at resolutions down to 50 μm. Using this facility, the subpixel level detector response of P2 was measured at 100 μm5 resolution and analyzed to extract and evaluate the area and profile of individual pixels, their morphology across the entire P2 detector plane for comparison with previous measurements and to provide additional characterization. In this article, we evaluate the imaging performance of a coded-aperture telescope using the observed pixel morphology for P2 detectors. This investigation will serve as an initial guide for detector selection in the development of HREXI detector planes, for the future implementation of the 4pi X-Ray Imaging Observatory (4piXIO)6 mission, which aims to provide simultaneous and continuous imaging of the full sky (4π sr) in the 3 to 200 keV energy band with ≃2 arcmin angular resolution and ≃10 arcsec source localization, as well as other, future coded-aperture instruments.


  • Tuning of nuclear spectroscopic telescope array application specific integrated circuits to improve low energy threshold of future hard x-ray imaging detectors

    by Daniel P. Violette, Branden E. Allen, Jae Sub E. Hong, Hiromasa Miyasaka, Jonathan E. Grindlay

    Detector commanding, processing and readout of spaceborne instrumentation is often accomplished with application specific integrated circuits (ASICs). The ASIC designed for the nuclear spectroscopic telescope array (NuSTAR) mission enables future tiled CdZnTe (CZT) detector array readout for x-ray detectors, such as the high resolution energetic x-ray imager (HREXI). Modified NuSTAR ASIC (NuASIC) gain settings have been implemented for HREXI’s broader targeted imaging energy range (3 to 300 keV) compared with NuSTAR (2 to 79 keV), which may require updated NuASIC internal parameters for optimal energy resolution. To reach HREXI’s targeted low energy threshold, we have also enabled the NuASIC’s “charge pump mode,” which introduces an additional tuning parameter. We describe the mechanics of the NuASIC’s adjustable parameters and use our recently developed ASIC test stand to probe a “bare” NuASIC using its internal test pulser. We record the effects of parameter tuning on the device’s electronics noise and low energy threshold and report the optimal set of parameters for HREXI’s updated gain setting. We detail a semiautomated procedure to derive the optimal parameters for each of HREXI’s large area closely tiled NuASIC/CZT detectors to expedite instrument integration.

  • Testing station for fast screening of through silicon via-enabled application-specific integrated circuits for hard x-ray imaging detectors

    by Daniel P. Violette, Branden Allen, Jaesub Hong, Hiromasa Miyasaka, Jonathan Grindlay

    Application-specific integrated circuits (ASICs) are used in space-borne instruments for signal processing and detector readout. The electrical interface of these ASICs to frontend printed circuit boards is commonly accomplished with wire bonds. Through silicon via (TSV) technology has been proposed as an alternative interconnect technique that will reduce assembly complexity of ASIC packaging by replacing wire bonding with flip-chip bonding. TSV technology is advantageous in large detector arrays where TSVs enable close detector tiling on all sides. Wafer-level probe card testing of TSV ASICs is frustrated by solder balls introduced onto the ASIC surface for flip-chip bonding that hamper alignment. Therefore, we developed the ASIC test stand (ATS) to enable rapid screening and characterization of individual ASIC die. We successfully demonstrated ATS operation on ASICs originally developed for CdZnTe detectors on the Nuclear Spectroscopic and Telescope Array (NuSTAR) mission that were later modified with TSVs in a via-last process. We tested both backside blind-TSVs and frontside through-TSVs, with results from internal test pulser measurements that demonstrate performance equal to or exceeding the probe card wafer-level testing data. The ATS can easily be expanded or duplicated to parallelize ASIC screening for large area imaging detectors of future space programs.


  • Miniature X-Ray Optics for Meter-Class Focal Length Telescopes

    by Jaesub Hong, Suzanne Romaine, Vinay L. Kashyap, Kiranmayee Kilaru

  • Calibration and Performance of the REgolith X-Ray Imaging Spectrometer (REXIS) Aboard NASA’s OSIRIS-REx Mission to Bennu

    by Jaesub Hong, Richard P. Binzel, Branden Allen, David Guevel, Jonathan Grindlay, Daniel Hoak, Rebecca Masterson, Mark Chodas, Madeline Lambert, Carolyn Thayer, et al.


  • Performance of a directly deposited optical blocking filter on x-ray CCDs: case study from the REgolith X-ray Imaging Spectrometer (REXIS) experiment

    by Carolyn Thayer, Rebecca Masterson, Branden Allen, Kevin Ryu, Marshall W. Bautz, Solan Megerssa, Mark Chodas, David Guevel, Daniel Hoak, Jaesub Hong, et al.

    The REgolith X-ray Imaging Spectrometer (REXIS) is a soft x-ray spectrometer and the student collaboration instrument aboard NASA’s OSIRIS-REx asteroid sample return mission. REXIS utilizes MIT Lincoln Laboratory CCID-41 x-ray detectors coated with a directly deposited optical blocking filter (OBF) with a thickness of 320 nm. The aluminum coating, developed at MIT Lincoln Laboratory, is designed to block visible light from the detector, to maintain high sensitivity to soft x-rays in the presence of reflected sunlight from the surface of the target asteroid Bennu. The scientific objective for the REXIS instrument is to measure the stimulated x-ray flux fluoresced from Bennu to discern elemental abundances present on the asteroid’s surface. The coating technique applied for blocking visible light had not previously been used on the CCD-41s in an extended space flight mission. The performance of the OBF on the flight detectors was not characterized before and after environmental stress testing. Therefore, to mature the OBF to technology readiness level (TRL) 6, the flight spare detectors were tested while the instrument was on the way to the asteroid. The flight spare hardware underwent vibration and thermal environmental stress testing to test the durability and effectiveness of the OBF. This testing informed our expectations of the in-flight OBF once it reached the asteroid and helped mature the TRL level of this directly deposited OBF. We discuss the setup and results of those tests and address the performance of the flight OBF at the asteroid. We conclude that depositing an aluminum OBF onto the surface of a charge-coupled device is able to withstand stresses of launch and an extended life-mission in interplanetary space.