Linxue Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Linxue Li has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Qi Zhang
College of Architecture and Urban Planning, Tongji University, Shanghai 200092, China
7 shared publications - Guangyi Zhang
College of Architecture and Urban Planning, Tongji University, Shanghai 200092, China
3 shared publications - Jinhao Liu
College of Architecture and Urban Planning, Tongji University, Shanghai 200092, China
3 shared publications Qi Zhang
Tongji University
3 shared publications- William W. Braham
University of Pennsylvania
3 shared publications - Peng Xu
School of Mechanical Engineering, Tongji University
2 shared publications
Latest Publications
- 29 October 2026
- Published by Elsevier in Building and Environment
- Vol. 307
Supporting building thermal resilience in early design stages: A framework integrating machine learning and large language models
- 29 October 2026
- Published by Elsevier in Building and Environment
- Vol. 307
Supporting building thermal resilience in early design stages: A framework integrating machine learning and large language models
- Open Access
Conditional Effectiveness of Night Ventilation During Heatwaves: Nonlinear Interactions Among Event Morphology, Thermal Mass and Operating Strategies
Consecutive warm nights during heatwaves erode the cooling potential of night ventilation (NV), making its effectiveness strongly dependent on both the event and the building conditions. This study quantified the nonlinear effects of heatwave morphology, building thermal mass (TM), and NV strategies on multidimensional thermal responses and identified the operating conditions associated with ventilation performance. Using a 1991–2020 climatological baseline, 36 heatwaves were characterized by eight morphology indicators. A total of 18,000 EnergyPlus simulations examined combinations of three TM levels, two ventilation configurations, window-to-wall ratios (WWRs) ranging from 0.10 to 0.70, openable fraction, and opening schedules. Six indicators captured daytime peaks, persistent overheating, peak temperature lag, nighttime overheating, thermal recovery, and nighttime cooling rate (NCR). Machine learning models were used to identify the governing mechanisms and delineate ventilation strategy regimes. All models achieved R2 values above 0.96 under case-level testing, while event-level performance varied across responses. Increasing TM lowered the median daytime peak temperature by 4.5 °C under cross-ventilation but did not improve every response. Predicted daytime peak risk increased sharply when the mean daily minimum temperature exceeded about 27.0 °C. Ventilation configuration also reversed the effects of opening time, duration, and WWR, precluding a single optimum that is independent of heatwave and building conditions. Effective cooling, operationally defined as positive predicted NCR, was generally associated with earlier opening and longer ventilation. Under single-sided ventilation, achieving stable positive predicted NCR generally required ventilation durations longer than approximately 4 h for buildings with low TM and longer than 6 h for those with medium TM. Under cross-ventilation, the corresponding effective domain in the strategy space contracted markedly, and no stable region with positive predicted NCR emerged for buildings with high TM. These findings support a shift from fixed window opening rules to control strategies tailored to heatwave characteristics and building thermophysical properties. The framework provides a basis for natural ventilation operation informed by forecasts, passive cooling retrofits, and thermally resilient building design.
Open AccessConditional Effectiveness of Night Ventilation During Heatwaves: Nonlinear Interactions Among Event Morphology, Thermal Mass and Operating Strategies
Consecutive warm nights during heatwaves erode the cooling potential of night ventilation (NV), making its effectiveness strongly dependent on both the event and the building conditions. This study quantified the nonlinear effects of heatwave morphology, building thermal mass (TM), and NV strategies on multidimensional thermal responses and identified the operating conditions associated with ventilation performance. Using a 1991–2020 climatological baseline, 36 heatwaves were characterized by eight morphology indicators. A total of 18,000 EnergyPlus simulations examined combinations of three TM levels, two ventilation configurations, window-to-wall ratios (WWRs) ranging from 0.10 to 0.70, openable fraction, and opening schedules. Six indicators captured daytime peaks, persistent overheating, peak temperature lag, nighttime overheating, thermal recovery, and nighttime cooling rate (NCR). Machine learning models were used to identify the governing mechanisms and delineate ventilation strategy regimes. All models achieved R2 values above 0.96 under case-level testing, while event-level performance varied across responses. Increasing TM lowered the median daytime peak temperature by 4.5 °C under cross-ventilation but did not improve every response. Predicted daytime peak risk increased sharply when the mean daily minimum temperature exceeded about 27.0 °C. Ventilation configuration also reversed the effects of opening time, duration, and WWR, precluding a single optimum that is independent of heatwave and building conditions. Effective cooling, operationally defined as positive predicted NCR, was generally associated with earlier opening and longer ventilation. Under single-sided ventilation, achieving stable positive predicted NCR generally required ventilation durations longer than approximately 4 h for buildings with low TM and longer than 6 h for those with medium TM. Under cross-ventilation, the corresponding effective domain in the strategy space contracted markedly, and no stable region with positive predicted NCR emerged for buildings with high TM. These findings support a shift from fixed window opening rules to control strategies tailored to heatwave characteristics and building thermophysical properties. The framework provides a basis for natural ventilation operation informed by forecasts, passive cooling retrofits, and thermally resilient building design.
- Open Access
Improving Ventilation Performance in a Multi-Storey Solar Chimney System Using Neutral Plane Analysis: A CFD Case Study
Multi-storey solar chimneys are often evaluated using shaft-outlet airflow, which may conceal uneven airflow distribution among floors. A shaft may provide adequate extraction while upper floors receive insufficient air or experience reverse airflow. This study examined the relationship between neutral plane (NP) position and floor-specific airflow to guide adjustments to openings in a nine-storey building with two solar chimneys. Three-dimensional unsteady computational fluid dynamics (CFD) simulations quantified airflow rate and direction on each floor, airflow at the shaft outlet, and NP height. During controlled case screening at a prescribed absorber-plate heat flux of 484.24 W/m2, each shaft’s outlet airflow exceeded the combined requirements of its connected floors, although reverse airflow occurred at 2F and 7F–9F. Reducing selected lower-floor opening areas raised the NP from 11.5 to 12.4 m in the west-shaft zone and from 29.2 to 35.9 m in the east-shaft zone, redistributing airflow upward without changing shaft geometry. Across the six evaluated transition-season months, compliance rates were 100% on 1F–7F, 79.2% on 8F, and 0% on 9F. Airflow remained inward on 8F throughout, whereas reverse airflow persisted on 9F. This study demonstrates that joint assessment of NP position alongside shaft-outlet airflow and floor-specific requirements distinguished insufficient extraction from uneven distribution and informed opening adjustments. Within the evaluated building and design space, however, the tested opening-area strategy did not resolve reverse airflow on 9F and would need to be combined with additional measures targeting the upper-floor pressure and airflow path to achieve building-wide compliance.
Open AccessImproving Ventilation Performance in a Multi-Storey Solar Chimney System Using Neutral Plane Analysis: A CFD Case Study
Multi-storey solar chimneys are often evaluated using shaft-outlet airflow, which may conceal uneven airflow distribution among floors. A shaft may provide adequate extraction while upper floors receive insufficient air or experience reverse airflow. This study examined the relationship between neutral plane (NP) position and floor-specific airflow to guide adjustments to openings in a nine-storey building with two solar chimneys. Three-dimensional unsteady computational fluid dynamics (CFD) simulations quantified airflow rate and direction on each floor, airflow at the shaft outlet, and NP height. During controlled case screening at a prescribed absorber-plate heat flux of 484.24 W/m2, each shaft’s outlet airflow exceeded the combined requirements of its connected floors, although reverse airflow occurred at 2F and 7F–9F. Reducing selected lower-floor opening areas raised the NP from 11.5 to 12.4 m in the west-shaft zone and from 29.2 to 35.9 m in the east-shaft zone, redistributing airflow upward without changing shaft geometry. Across the six evaluated transition-season months, compliance rates were 100% on 1F–7F, 79.2% on 8F, and 0% on 9F. Airflow remained inward on 8F throughout, whereas reverse airflow persisted on 9F. This study demonstrates that joint assessment of NP position alongside shaft-outlet airflow and floor-specific requirements distinguished insufficient extraction from uneven distribution and informed opening adjustments. Within the evaluated building and design space, however, the tested opening-area strategy did not resolve reverse airflow on 9F and would need to be combined with additional measures targeting the upper-floor pressure and airflow path to achieve building-wide compliance.
- Open Access
Integrating a Solar Chimney into a Traditional Skywell Dwelling: A New Climate-Adaptive Retrofit Design Approach
Traditional skywell dwellings embody climate-responsive passive design but may remain hot and humid under low-wind summer conditions, requiring passive-ventilation retrofits while preserving their spatial organization. Skywell performance and component-level solar chimneys are comparatively well studied, but their direct integration in traditional multi-room dwellings remains at an early stage. This study develops a climate-adaptive retrofit design approach that integrates a solar chimney with the existing skywell of a traditional rammed-earth dwelling in Songyang, China. Field monitoring showed that mean relative humidity exceeded 90% at all five indoor locations. An EnergyPlus Airflow Network model was calibrated against hourly temperatures from four rooms, yielding RMSE values of 0.33–0.91 °C, with 84.8% of predictions within ±1 °C. The calibrated model was used to compare the baseline and retrofit configurations during a selected 72 h hot period and across the full summer, while the 2000-configuration parametric study retained the 72 h window. During the selected period, the retrofit lowered the simulated operative temperature in all 432 paired hourly comparisons, with a mean reduction of 1.73 °C. Across the full summer, it produced lower operative temperature in 94.7% of 13,248 paired hourly comparisons, with a comparable mean reduction of 1.67 °C, and increased the percentage of hours within the adaptive comfort band from 33.9% to 52.0%. The first-floor hall showed the largest cooling benefit, whereas the second-floor rooms were more responsive to changes in vertical chimney geometry. Overall chimney height and outlet opening height jointly accounted for 85.19–95.09% of random forest feature importance. The collector glazing parameters were more influential in the skywell–chimney zone. These findings support a design hierarchy that prioritizes airflow continuity and vertical exhaust geometry before collector glazing, providing a quantitative basis for solar chimney retrofits that preserve spatial organization of traditional skywell dwellings.
Open AccessIntegrating a Solar Chimney into a Traditional Skywell Dwelling: A New Climate-Adaptive Retrofit Design Approach
Traditional skywell dwellings embody climate-responsive passive design but may remain hot and humid under low-wind summer conditions, requiring passive-ventilation retrofits while preserving their spatial organization. Skywell performance and component-level solar chimneys are comparatively well studied, but their direct integration in traditional multi-room dwellings remains at an early stage. This study develops a climate-adaptive retrofit design approach that integrates a solar chimney with the existing skywell of a traditional rammed-earth dwelling in Songyang, China. Field monitoring showed that mean relative humidity exceeded 90% at all five indoor locations. An EnergyPlus Airflow Network model was calibrated against hourly temperatures from four rooms, yielding RMSE values of 0.33–0.91 °C, with 84.8% of predictions within ±1 °C. The calibrated model was used to compare the baseline and retrofit configurations during a selected 72 h hot period and across the full summer, while the 2000-configuration parametric study retained the 72 h window. During the selected period, the retrofit lowered the simulated operative temperature in all 432 paired hourly comparisons, with a mean reduction of 1.73 °C. Across the full summer, it produced lower operative temperature in 94.7% of 13,248 paired hourly comparisons, with a comparable mean reduction of 1.67 °C, and increased the percentage of hours within the adaptive comfort band from 33.9% to 52.0%. The first-floor hall showed the largest cooling benefit, whereas the second-floor rooms were more responsive to changes in vertical chimney geometry. Overall chimney height and outlet opening height jointly accounted for 85.19–95.09% of random forest feature importance. The collector glazing parameters were more influential in the skywell–chimney zone. These findings support a design hierarchy that prioritizes airflow continuity and vertical exhaust geometry before collector glazing, providing a quantitative basis for solar chimney retrofits that preserve spatial organization of traditional skywell dwellings.
- Open Access
A Multi-Source Data-Driven Fault Detection and Diagnosis Method for Pumps
Fault detection and diagnosis (FDD) in pumps is crucial for building energy management by detecting the abnormal operation status, increasing the service life of equipment, and enhancing the energy performance of buildings. Most FDD methods predominantly rely on single-source data, such as building automation (BA) data or vibration data. However, sensors in BA systems are prone to inaccuracies, which consequently impedes the performance of FDD algorithms. This paper proposes a novel FDD method for pumps based on multi-source data, which integrates traditional BA electrical power data with non-intrusive measurements, including audio data, vibration data, and infrared thermal images. The method includes two stages: (1) multi-source data anomaly detection and (2) pump fault diagnosis. Various fault scenarios were tested on an experimental platform. The results demonstrate that the proposed method can effectively diagnosis pump faults in detail, such as voltage fluctuations, shaft or bearing wear and tear, inadequate ventilation, and foundation vibration. With intrusive and non-intrusive data, the proposed FDD method is more robust and could provide more detailed diagnosis of pump faults.
Open AccessA Multi-Source Data-Driven Fault Detection and Diagnosis Method for Pumps
Fault detection and diagnosis (FDD) in pumps is crucial for building energy management by detecting the abnormal operation status, increasing the service life of equipment, and enhancing the energy performance of buildings. Most FDD methods predominantly rely on single-source data, such as building automation (BA) data or vibration data. However, sensors in BA systems are prone to inaccuracies, which consequently impedes the performance of FDD algorithms. This paper proposes a novel FDD method for pumps based on multi-source data, which integrates traditional BA electrical power data with non-intrusive measurements, including audio data, vibration data, and infrared thermal images. The method includes two stages: (1) multi-source data anomaly detection and (2) pump fault diagnosis. Various fault scenarios were tested on an experimental platform. The results demonstrate that the proposed method can effectively diagnosis pump faults in detail, such as voltage fluctuations, shaft or bearing wear and tear, inadequate ventilation, and foundation vibration. With intrusive and non-intrusive data, the proposed FDD method is more robust and could provide more detailed diagnosis of pump faults.
- Open Access
An Interpretable Modeling Method for Occupancy in Public Buildings Based on Typical Occupancy Data
Occupancy, defined as the count of occupants, plays an important role in building design and operation stages. Obtaining reliable occupancy data for public buildings remains a challenging problem due to the lack of available on-site data. With the development of information technologies, the widespread use of smartphones and social networks provides a source for collecting building occupancy data. In this paper, we collect occupancy data of 56 public buildings from social networks. Based on this database, an interpretable occupancy model is proposed, incorporating the effects of trend, day types, months, meteorological parameters, and special events, such as the COVID-19 period, discount days, etc. The modeling process includes following four steps: (1) extracting typical occupancy data (TOD), (2) extracting key factors through the CatBoost model and SHAP method, (3) model fitting, and (4) model transfer application. The proposed method quantifies the influence of different factors on occupancy and can be applied to simulate occupancy in public buildings without on-site data. Its performance is evaluated through a case study on four public buildings in this paper.
Open AccessAn Interpretable Modeling Method for Occupancy in Public Buildings Based on Typical Occupancy Data
Occupancy, defined as the count of occupants, plays an important role in building design and operation stages. Obtaining reliable occupancy data for public buildings remains a challenging problem due to the lack of available on-site data. With the development of information technologies, the widespread use of smartphones and social networks provides a source for collecting building occupancy data. In this paper, we collect occupancy data of 56 public buildings from social networks. Based on this database, an interpretable occupancy model is proposed, incorporating the effects of trend, day types, months, meteorological parameters, and special events, such as the COVID-19 period, discount days, etc. The modeling process includes following four steps: (1) extracting typical occupancy data (TOD), (2) extracting key factors through the CatBoost model and SHAP method, (3) model fitting, and (4) model transfer application. The proposed method quantifies the influence of different factors on occupancy and can be applied to simulate occupancy in public buildings without on-site data. Its performance is evaluated through a case study on four public buildings in this paper.
- Open Access
Thermal Resilience of Public Building Atriums Under Different States During Heatwaves
Under the influence of climate change, extreme heat events are becoming more frequent and intense. Understanding the response mechanisms of public building spaces, such as atriums, during extreme heat events is of great significance for developing effective design strategies to enhance the thermal resilience of buildings. This study investigated the effect of atrium spaces on the thermal resilience of buildings during heatwaves, focusing on their ability to mitigate high temperatures under two states: closed and open. The research monitored the indoor and outdoor temperature and humidity data of the atrium of a university building in Shanghai during a typical heatwave, and used statistical methods to analyze the relationships between the thermal resilience indicators and various environmental parameters, including the indoor and outdoor temperatures and ventilation states, to evaluate the thermal performance of the atrium. The results indicate that the atrium demonstrated robust thermal resilience under both closed and open conditions. In the closed phase, the indoor temperature was, on average, approximately 7 °C lower than the outdoor temperature, with the maximum difference reaching 11 °C, and the peak temperature delay was up to 4 h. In the open phase, despite exhibiting larger thermal fluctuations and an increase in temperature non-uniformity, the thermal resilience index improved significantly, from 0.231 in the closed phase to 0.047. The analytical framework developed in this study shows great potential for understanding the thermal resilience mechanisms of buildings during extreme heat events. Additionally, the data-driven insights are invaluable for informing the design strategies of public building spaces, especially in regions prone to extreme heat.
Open AccessThermal Resilience of Public Building Atriums Under Different States During Heatwaves
Under the influence of climate change, extreme heat events are becoming more frequent and intense. Understanding the response mechanisms of public building spaces, such as atriums, during extreme heat events is of great significance for developing effective design strategies to enhance the thermal resilience of buildings. This study investigated the effect of atrium spaces on the thermal resilience of buildings during heatwaves, focusing on their ability to mitigate high temperatures under two states: closed and open. The research monitored the indoor and outdoor temperature and humidity data of the atrium of a university building in Shanghai during a typical heatwave, and used statistical methods to analyze the relationships between the thermal resilience indicators and various environmental parameters, including the indoor and outdoor temperatures and ventilation states, to evaluate the thermal performance of the atrium. The results indicate that the atrium demonstrated robust thermal resilience under both closed and open conditions. In the closed phase, the indoor temperature was, on average, approximately 7 °C lower than the outdoor temperature, with the maximum difference reaching 11 °C, and the peak temperature delay was up to 4 h. In the open phase, despite exhibiting larger thermal fluctuations and an increase in temperature non-uniformity, the thermal resilience index improved significantly, from 0.231 in the closed phase to 0.047. The analytical framework developed in this study shows great potential for understanding the thermal resilience mechanisms of buildings during extreme heat events. Additionally, the data-driven insights are invaluable for informing the design strategies of public building spaces, especially in regions prone to extreme heat.
- 23 December 2024
- Published by Springer Nature
- p. 42-47
Research About the Coupling Effect of Solar Chimney-Tunnel Composite Ventilation System in Atrium Space
- 23 December 2024
- Published by Springer Nature
- p. 42-47
Research About the Coupling Effect of Solar Chimney-Tunnel Composite Ventilation System in Atrium Space
- Open Access
Sustainable Design Methods Translated from the Thermodynamic Theory of Vernacular Architecture: Atrium Prototypes
In the context of China’s sustainable development and dual carbon goals, research on thermodynamic architecture theory and vernacular architecture increasingly aligns with international trends, developing distinct characteristics. This research addresses the challenge of rapid changes in the built environment by focusing on climate adaptability and passive technologies. However, the development of thermodynamic theory in vernacular architecture faced technical limitations in the early 21st century and was later overshadowed by the industry’s reliance on active technologies to meet green building standards, resulting in a reduced role for architects in the green building field. This article traces the origins of passive architecture, rooted in vernacular architecture, and applies thermodynamic theory to explore architectural prototypes. It examines the theoretical feasibility of architectural design in achieving low-carbon and sustainable goals, aiming to fill a gap in thermodynamic theory within the broader context of sustainable architectural development. After demonstrating the various passive prototypes inherent in vernacular architecture, this paper proposes a courtyard prototype focused on residential comfort for design translation and analysis. The research methods employed include bioclimatic charting, balance point temperature analysis in time series, and extensive computer simulations. Through the process of prototype extraction, performance analysis, validation, and optimization, the paper systematically discusses sustainable design methods within the framework of thermodynamic architecture theory. It also provides practical demonstrations of these methods across four distinct climate regions in China. By translating vernacular architectural designs, this research systematically organizes the theoretical framework for architects’ early involvement in low-carbon and green building design, offering a theoretical foundation for initiating the design process through prototype translation while guiding the generation of green ecological buildings.
Open AccessSustainable Design Methods Translated from the Thermodynamic Theory of Vernacular Architecture: Atrium Prototypes
In the context of China’s sustainable development and dual carbon goals, research on thermodynamic architecture theory and vernacular architecture increasingly aligns with international trends, developing distinct characteristics. This research addresses the challenge of rapid changes in the built environment by focusing on climate adaptability and passive technologies. However, the development of thermodynamic theory in vernacular architecture faced technical limitations in the early 21st century and was later overshadowed by the industry’s reliance on active technologies to meet green building standards, resulting in a reduced role for architects in the green building field. This article traces the origins of passive architecture, rooted in vernacular architecture, and applies thermodynamic theory to explore architectural prototypes. It examines the theoretical feasibility of architectural design in achieving low-carbon and sustainable goals, aiming to fill a gap in thermodynamic theory within the broader context of sustainable architectural development. After demonstrating the various passive prototypes inherent in vernacular architecture, this paper proposes a courtyard prototype focused on residential comfort for design translation and analysis. The research methods employed include bioclimatic charting, balance point temperature analysis in time series, and extensive computer simulations. Through the process of prototype extraction, performance analysis, validation, and optimization, the paper systematically discusses sustainable design methods within the framework of thermodynamic architecture theory. It also provides practical demonstrations of these methods across four distinct climate regions in China. By translating vernacular architectural designs, this research systematically organizes the theoretical framework for architects’ early involvement in low-carbon and green building design, offering a theoretical foundation for initiating the design process through prototype translation while guiding the generation of green ecological buildings.
- 17 April 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 89
A spatial analysis of ozone and PM2.5 distribution for assessing design factors of healthy buildings
- 17 April 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 89
A spatial analysis of ozone and PM2.5 distribution for assessing design factors of healthy buildings