Tuomas Pärnänen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Tuomas Pärnänen has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Mikko Kanerva
Tampere University
8 shared publications - Jarno Jokinen
Tampere University
6 shared publications - Essi Sarlin
Tampere University
5 shared publications O. Saarela
Department of Mechanical Engineering,Aalto University, School of Engineering,Espoo,Finland
3 shared publicationsD. Schlenzka
Orton Orthopaedic Hospital and Research Institute Orton, FI-00280, Helsinki, Finland
2 shared publications- Jyrki Vuorinen
Tampere University of Technology
2 shared publications
Latest Publications
- Open Access
- 2 December 2019
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 38 (5) , 984-995
Multi‐Axis Fatigue Experimentation System of Intramedullary Implants for Femur and Tibia
Current designs of leg‐lengthening implants have faced serious failures due to inadequacies in the mechanical design. The failure typically is the result of fatigue induced by a combined loading condition with axial and shear components acting in the tubular body of the implant. One of the reasons leading to the failure is improper verification testing for the design of the fatigue limit. The current test standards for pre‐clinical design phases of nail implants are relatively straightforward and widely accepted yet cannot produce the three‐dimensional stress state representative of the anticipated operation in a patient during the consolidation phase. This work introduces a major improvement toward a method for verifying fatigue life of tubular as well as solid implants under combined torque, axial load, and bending. The report describes a new loading fixture, a calibration method, and compares the qualification results of finite element simulation analyses and experimental measurements during cyclic loading tests. The findings state that the fixture produces controlled multi‐axial loadings to study varied osteotomy locations, quasi‐static strength and fatigue of intramedullary implants at an intermediate, 2 Hz, cycle rate. © 2019 The Authors. Journal of Orthopaedic Research® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 38:984‐995, 2020
- 2 December 2019
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 38 (5) , 984-995
Open AccessMulti‐Axis Fatigue Experimentation System of Intramedullary Implants for Femur and Tibia
Current designs of leg‐lengthening implants have faced serious failures due to inadequacies in the mechanical design. The failure typically is the result of fatigue induced by a combined loading condition with axial and shear components acting in the tubular body of the implant. One of the reasons leading to the failure is improper verification testing for the design of the fatigue limit. The current test standards for pre‐clinical design phases of nail implants are relatively straightforward and widely accepted yet cannot produce the three‐dimensional stress state representative of the anticipated operation in a patient during the consolidation phase. This work introduces a major improvement toward a method for verifying fatigue life of tubular as well as solid implants under combined torque, axial load, and bending. The report describes a new loading fixture, a calibration method, and compares the qualification results of finite element simulation analyses and experimental measurements during cyclic loading tests. The findings state that the fixture produces controlled multi‐axial loadings to study varied osteotomy locations, quasi‐static strength and fatigue of intramedullary implants at an intermediate, 2 Hz, cycle rate. © 2019 The Authors. Journal of Orthopaedic Research® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 38:984‐995, 2020
- Open Access
- 1 November 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 99, 93-103
Miniature CoCr laser welds under cyclic shear: Fatigue evolution and crack growth
- 1 November 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 99, 93-103
Open AccessMiniature CoCr laser welds under cyclic shear: Fatigue evolution and crack growth
- Open Access
- 1 October 2019
- Published by Elsevier in Data in Brief
- Vol. 26, 104374
Automatization and stress analysis data of CoCr laser weld fatigue tests
- 1 October 2019
- Published by Elsevier in Data in Brief
- Vol. 26, 104374
Open AccessAutomatization and stress analysis data of CoCr laser weld fatigue tests
- Open Access
- 1 March 2019
- Published by Elsevier in Composite Structures
- Vol. 212, 524-534
Lower stiffness of GFRP after sulfuric acid-solution aging is due to degradation of fibre-matrix interfaces?
- 1 March 2019
- Published by Elsevier in Composite Structures
- Vol. 212, 524-534
Open AccessLower stiffness of GFRP after sulfuric acid-solution aging is due to degradation of fibre-matrix interfaces?
- 15 July 2018
- Published by Springer Nature
- p. 171-183
Lateral Indentation and Impact Analyses on Curved Composite Shells
- 15 July 2018
- Published by Springer Nature
- p. 171-183
Lateral Indentation and Impact Analyses on Curved Composite Shells
- 1 May 2017
- Published by Elsevier in Composite Structures
- Vol. 168, 840-850
The effect of matrix type on ageing of thick vinyl ester glass-fibre-reinforced laminates
- 1 May 2017
- Published by Elsevier in Composite Structures
- Vol. 168, 840-850
The effect of matrix type on ageing of thick vinyl ester glass-fibre-reinforced laminates
- 11 June 2016
- Published by Springer Nature in Applied Composite Materials
- Vol. 23 (6) , 1151-1166
The Effects of Debonding on the Low-Velocity Impact Response of Steel-CFRP Fibre Metal Laminates
- 11 June 2016
- Published by Springer Nature in Applied Composite Materials
- Vol. 23 (6) , 1151-1166
The Effects of Debonding on the Low-Velocity Impact Response of Steel-CFRP Fibre Metal Laminates
- 1 January 2015
- Published by Elsevier in Composite Structures
- Vol. 119, 777-786
Debonding and impact damage in stainless steel fibre metal laminates prior to metal fracture
- 1 January 2015
- Published by Elsevier in Composite Structures
- Vol. 119, 777-786
Debonding and impact damage in stainless steel fibre metal laminates prior to metal fracture
- 1 September 2012
- Published by Elsevier in Composites Part A: Applied Science and Manufacturing
- Vol. 43 (9) , 1578-1586
Applicability of AZ31B-H24 magnesium in Fibre Metal Laminates – An experimental impact research
- 1 September 2012
- Published by Elsevier in Composites Part A: Applied Science and Manufacturing
- Vol. 43 (9) , 1578-1586
Applicability of AZ31B-H24 magnesium in Fibre Metal Laminates – An experimental impact research
- 27 October 2011
- Published by Springer Nature in Applied Composite Materials
- Vol. 19 (3-4) , 545-559
Experimental and Numerical Investigation of Metal Type and Thickness Effects on the Impact Resistance of Fiber Metal Laminates
- 27 October 2011
- Published by Springer Nature in Applied Composite Materials
- Vol. 19 (3-4) , 545-559
Experimental and Numerical Investigation of Metal Type and Thickness Effects on the Impact Resistance of Fiber Metal Laminates